A context-aware approach for long-term behavioural change detection and abnormality prediction in ambient assisted living

2015

This research aims to describe pattern recognition models for detecting behavioural and health-related changes in a patient who is monitored continuously in an assisted living environment. The early anticipation of anomalies can improve the rate of disease prevention. Here we present different learning techniques for predicting abnormalities and behavioural trends in various user contexts. In this paper we described a Hidden Markov Model based approach for detecting abnormalities in daily activities, a process of identifying irregularity in routine behaviours from statistical histories and an exponential smoothing technique to predict future changes in various vital signs. The outcomes of t…

Activities of daily livingComputer scienceContext (language use)computer.software_genreMachine learningHidden Markov ModelArtificial IntelligencePattern recognitionHealth careCloud computingTrend detectionHidden Markov modelFuzzy ruleContext-awarebusiness.industryHealthcare[INFO.INFO-IA]Computer Science [cs]/Computer Aided EngineeringStatistical process control3. Good healthAmbient assisted livingRemote monitoringEldercareAnticipation (artificial intelligence)Signal ProcessingPattern recognition (psychology)Change detectionComputer Vision and Pattern RecognitionArtificial intelligenceData miningbusinesscomputerSoftwareChange detectionPattern Recognition
researchProduct

Adaptive scheduling of acceleration and gyroscope for motion artifact cancelation in photoplethysmography

2022

Background and objective: Recently, various algorithms have been introduced using wrist-worn photo-plethysmography (PPG) to provide high accuracy of instantaneous heart rate (HR) estimation, including during high-intensity exercise. Most studies focus on using acceleration and/or gyroscope signals for the motion artifact (MA) reference, which attenuates or cancels out noise from the MA-corrupted PPG signals. We aim to open and pave the path to find an appropriate MA reference selection for MA cancelation in PPG.Methods: We investigated how the acceleration and gyroscope reference signals correlate with the MAs of the distorted PPG signals and derived both mathematically and experimentally a…

Adaptive motion artifact reference selectionInstantaneous heart rate (HR)Gyroscope signalAccelerationSignal Processing Computer-AssistedHealth InformaticsSettore ING-INF/01 - ElettronicaComputer Science ApplicationsAcceleration signalMotionHeart RateSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaReflectance-type photoplethysmography (PPG)PhotoplethysmographyArtifactsAlgorithmsSoftwareComputer Methods and Programs in Biomedicine
researchProduct

Virtual reality system for planning minimally invasive neurosurgery

2008

Object The authors report on their experience with a 3D virtual reality system for planning minimally invasive neurosurgical procedures. Methods Between October 2002 and April 2006, the authors used the Dextroscope (Volume Interactions, Ltd.) to plan neurosurgical procedures in 106 patients, including 100 with intracranial and 6 with spinal lesions. The planning was performed 1 to 3 days preoperatively, and in 12 cases, 3D prints of the planning procedure were taken into the operating room. A questionnaire was completed by the neurosurgeon after the planning procedure. Results After a short period of acclimatization, the system proved easy to operate and is currently used routinely for pre…

AdenomaAdultMaleHemangioma Cavernous Central Nervous Systemmedicine.medical_specialtySurgical strategyClinical Neurology610 Medicine & healthPlan (drawing)Virtual realitySurgical planningNeurosurgical ProceduresPatient Care PlanningUser-Computer Interface10180 Clinic for NeurosurgeryImaging Three-DimensionalImage Processing Computer-AssistedmedicineHumansMinimally Invasive Surgical ProceduresComputer SimulationMedical physicsAgedBrain Neoplasmsbusiness.industryAngiographyIntracranial AneurysmTechnical noteGeneral MedicineMiddle AgedMagnetic Resonance Imaging2746 SurgerySurgeryDextroscopeDiffusion Magnetic Resonance Imaging2728 Neurology (clinical)Surgery Computer-AssistedIntracranial lesionsFemaleSurgeryNeurosurgeryMeningiomaTomography X-Ray ComputedbusinessMagnetic Resonance AngiographyJournal of Neurosurgery
researchProduct

Autostereoscopic Three-Dimensional Neuronavigation to the Sella: Technical Note.

2017

Background A drawback of conventional neuronavigation is the necessity of focusing on two-dimensional images in 3 planes at the same time to determine one's position in the operating field. A solution would be to merge the images into a single three-dimensional (3D) image that mirrors the actual anatomy. The introduction of holographic glassless 3D monitors paved the way to 3D navigation. We present our experience with 3D neuronavigation as exemplified by navigation to and within the sella. Methods Operative planning was conducted with a navigation system using cranial computed tomography and magnetic resonance imaging. The image data sets were processed by the prototype Clariti 3D system t…

AdenomaAdultMaleNeuronavigationComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONsyncHolographyPilot Projects02 engineering and technology3D renderinglaw.invention03 medical and health sciences0302 clinical medicineImaging Three-DimensionallawAutostereoscopy0202 electrical engineering electronic engineering information engineeringMedicineHumansComputer visionPituitary NeoplasmsSella TurcicaLongitudinal StudiesNeuronavigationAgedAged 80 and overbusiness.industryNavigation system020207 software engineeringTechnical noteMiddle AgedNeuroendoscopySurgery Computer-AssistedSurgeryFemaleNeurology (clinical)Artificial intelligencebusiness030217 neurology & neurosurgeryWorld neurosurgery
researchProduct

Perfusion MRI in normal and abnormal pituitary gland. A preliminary study.

1997

Perfusion MRI (magnetic resonance imaging) of the pituitary gland was performed in 20 healthy volunteers and 63 patients with various lesions involving the pituitary gland. All patients underwent sequential contrast-enhanced MRI using spoiled gradient recalled sequences with high temporal resolution (7 seconds). Four pituitary areas (pituitary stalk, posterior lobe, postero-superior, and antero-inferior adenohypophysis) were tested with a selected region of interest. Maximal contrast percentual variation was calculated. The timing of enhancement in normal patients matched perfectly with normal pituitary vascularization. Abnormal timing in pathological condition was investigated.

AdenomaGadolinium DTPAMalePituitary glandPathologymedicine.medical_specialtyPituitary diseasePituitary DiseasesContrast MediaDiagnosis DifferentialAdrenocorticotropic HormoneRegion of interestReference ValuesmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingPituitary NeoplasmsProlactinomaPathologicalPituitary stalkmedicine.diagnostic_testbusiness.industryMagnetic resonance imagingmedicine.diseaseMagnetic Resonance ImagingLobemedicine.anatomical_structureRegional Blood FlowPituitary GlandFemalebusinessNuclear medicinePerfusionClinical imaging
researchProduct

3D microvascular architecture of pre-cancerous lesions and invasive carcinomas of the colon.

2001

Despite the significance of tumour neoangiogenesis and the extensive knowledge on the molecular basis of blood vessel formation currently no quantitative data exist on the 3D microvascular architecture in human primary tumours and their precursor lesions. This prompted us to examine the 3D vascular network of normal colon mucosa, adenomas and invasive carcinomas by means of quantitative microvascular corrosion casting. Fresh hemicolectomy specimens from 20 patients undergoing cancer or polyposis coli surgery were used for corrosion casting, factor VIII and VEGF immunostaining. In addition, immunostaining was done on colorectal tissue from 33 patients with metastatic and non-metastatic carci…

AdenomaMaleVascular Endothelial Growth Factor ACancer ResearchPathologymedicine.medical_specialtytumour vascular architectureAdenomaAngiogenesisAdenomatous polyposis coliEndothelial Growth FactorsMetastasisNeovascularizationangiogenesisImage Processing Computer-AssistedMedicineHumansNeoplasm InvasivenessGrading (tumors)AgedLymphokinesbiologybusiness.industryVascular Endothelial Growth FactorsMicrocirculationCancerRegular ArticleMiddle Agedmedicine.diseasecolorectal adenocarcinomapre-cancerous lesionsOncologyAdenomatous Polyposis ColiColonic Neoplasmsbiology.proteinFemalemedicine.symptombusinessColorectal NeoplasmsPrecancerous ConditionsImmunostainingBritish journal of cancer
researchProduct

High-definition imaging in endoscopic transsphenoidal pituitary surgery.

2011

Background The transsphenoidal approach to sellar lesions has evolved enormously since its first description in the early 20th century. Endoscopic surgical strategies have become an integral part of the surgical armamentarium. More recently, high-definition (HD) digital cameras with better image resolution were introduced, although their value for the surgical procedure remains equivocal. The purpose of this study was to compare the image quality of a standard-definition (SD) camera with a new HD camera. Methods A transsphenoidal pituitary adenomectomy was recorded simultaneously in HD and SD resolution. Eight experienced neurosurgeons were asked to identify predefined as well as not predef…

Adenomamedicine.medical_specialtyQuality Assurance Health CareImage qualitymedicine.medical_treatmentVideo-Assisted SurgeryVideo qualityStatistical significanceSphenoid BonemedicineImmunology and AllergyHumansPituitary NeoplasmsHypophysectomymedicine.diagnostic_testbusiness.industryOrientation (computer vision)EndoscopySignal Processing Computer-AssistedGeneral MedicineMicrosurgeryImage EnhancementEndoscopyOtorhinolaryngologyEquipment and SuppliesVisual PerceptionRadiologyPituitary surgerybusinessQuality assuranceAmerican journal of rhinologyallergy
researchProduct

Cervical pregnancy in assisted reproduction: an analysis of risk factors in 91,067 ongoing pregnancies

2019

Abstract Research question What is the frequency of cervical pregnancy in women undergoing assisted reproductive technologies (ART) and what are the risk factors? Design Case-control study of women undergoing assisted reproductive technology (ART) at 25 private assisted reproduction clinics run by the same group in Spain. Two control groups (tubal ectopic pregnancies and intrauterine pregnancies) were established. The main outcome measure was frequency of cervical pregnancy. Demographic, clinical factors and IVF parameters were assessed for their influence on cervical pregnancy risk. Results Thirty-two clinical pregnancies were achieved out of 91,067 ongoing pregnancies, yielding a rate of …

Adult0301 basic medicineInfertilitymedicine.medical_specialtyReproductive Techniques AssistedEmbaràs Complicacionsmedicine.medical_treatmentCervical pregnancyReproductive technology03 medical and health sciences0302 clinical medicinePregnancyRisk FactorsmedicineHumansRetrospective StudiesPregnancy030219 obstetrics & reproductive medicineAssisted reproductive technologyEctopic pregnancyObstetricsbusiness.industryIncidenceObstetrics and GynecologyPublication biasMiddle Agedmedicine.diseaseCurettagePregnancy Ectopic030104 developmental biologyReproductive MedicineSpainCase-Control StudiesFemalebusinessDevelopmental Biology
researchProduct

The 2015 International Society for Heart and Lung Transplantation Guidelines for the management of fungal infections in mechanical circulatory suppor…

2016

Shahid Husain, MD, MS, Amparo Sole, MD, PhD, Barbara D. Alexander, MD, MHS, Saima Aslam, MD, MS, Robin Avery, MD, Christian Benden, MD, Eliane M. Billaud, PharmD, PhD, Daniel Chambers, MBBS, MD, Lara Danziger-Isakov, MD, Savitri Fedson, MD, Kate Gould, MD, Aric Gregson, MD, Paolo Grossi, MD, PhD, Denis Hadjiliadis, MD, Peter Hopkins, MD, Me-Linh Luong, MD, Debbie J.E. Marriott, MD, Victor Monforte, MD, Patricia Munoz, MD, PhD, Alessandro C. Pasqualotto, MD, PhD, Antonio Roman, MD, Fernanda P. Silveira, MD, Jeffrey Teuteberg, MD, MS, Stephen Weigt, MD, Aimee K. Zaas, MD, MHS, Andreas Zuckerman, MD, and Orla Morrissey, MD, PhD

Adult0301 basic medicinePulmonary and Respiratory Medicinemedicine.medical_specialty2747 TransplantationHeart-Lung Transplantation030106 microbiology610 Medicine & health030230 surgery2705 Cardiology and Cardiovascular Medicine03 medical and health sciencesPostoperative Complications0302 clinical medicinePrevalencemedicineHumansAssisted CirculationChildTransplantationbusiness.industryIncidence2746 SurgerySurgeryMycoses2740 Pulmonary and Respiratory MedicineAdult; Child; Humans; Incidence; Mycoses; Postoperative Complications; Prevalence; Assisted Circulation; Heart-Lung Transplantation; Surgery; Pulmonary and Respiratory Medicine; Cardiology and Cardiovascular Medicine; TransplantationSurgery10178 Clinic for PneumologyCardiology and Cardiovascular MedicinebusinessHumanitiesThe Journal of Heart and Lung Transplantation
researchProduct

P and R Wave Detection in Complete Congenital Atrioventricular Block

2009

Complete atrioventricular block (type III AVB) is characterized by an absence of P wave transmission to ventricles. This implies that QRS complexes are generated in an autonomous way and are not coordinated with P waves. This work introduces a new algorithm for the detection of P waves for this type of pathology using non-invasive electrocardiographic surface leads. The proposed algorithm is divided into three stages. In the first stage, the R waves located by a QRS detector are used to generate the RR series and time references for the other stages of the algorithm. In the second stage, the ventricular activity (QT segment) is removed by using an adaptive filter that obtains an averaged pa…

AdultAdolescentBiomedical EngineeringYoung AdultQRS complexHeart Conduction SystemmedicineHumansSensitivity (control systems)Atrioventricular BlockChildMathematicsSeries (mathematics)P waveDetectorSignal Processing Computer-Assistedmedicine.diseaseAdaptive filterTransmission (telecommunications)Child PreschoolElectrocardiography AmbulatoryEnginyeria biomèdicaAtrioventricular blockAlgorithmAlgorithmsAnnals of Biomedical Engineering
researchProduct