Search results for "Solid phase extraction"

showing 10 items of 297 documents

Evaluation of C18 adsorbent cartridges for sampling and derivatization of primary amines in air

2004

Abstract The sampling efficiency of C18 solid-phase extraction cartridges was investigated for methylamine, ethylamine, propylamine, butylamine and pentylamine, in air. Determination of these analytes was based on derivatization with o-phthaldialdehyde–N-acetylcysteine (OPA–NAC) on the solid support and fluorescence detection at λexcitation=330 nm and λemission=440 nm of the eluted derivatives. The calibration model derived from aqueous standards was statistically comparable with the calibration model for air standards. Aqueous amines can be used as standards. The method was useful for calculating short-term exposure limits (STEL). A sampling time of 15 min at 30 ml min−1 was employed. Good…

Detection limitChromatographyButylamineFluorescence spectrometryAnalytical chemistryPropylamineBiochemistryAnalytical ChemistryStandard curvechemistry.chemical_compoundchemistryEnvironmental ChemistrySolid phase extractionPentylamineDerivatizationSpectroscopyAnalytica Chimica Acta
researchProduct

Simultaneous quantification of 18 different phytocannabinoids in serum using a highly sensitive liquid chromatography-tandem mass spectrometry (LC-MS…

2021

Abstract The potential therapeutic effects of various phytocannabinoids and the availability of multiple cannabis-based medicines make it desirable to have an analytical method that simultaneously quantifies a wide range of cannabinoids in blood, beyond delta-9-tetrahydrocannabinol and its metabolites. A liquid chromatography tandem mass spectrometry (LC-MS/MS) method for quantification of 18 phytocannabinoids and cannabinoid metabolites in serum was developed and validated. The method enables simultaneous detection of delta-9-tetrahydrocannabinol, cannabidiol, cannabinol, cannabigerol, cannabichromene, cannabicyclol, tetrahydrocannabivarin and cannabidivarin and their acidic precursors tet…

Detection limitChromatographyCannabigerol010401 analytical chemistryClinical BiochemistryCell BiologyGeneral MedicineTetrahydrocannabivarin030226 pharmacology & pharmacy01 natural sciencesBiochemistryCannabicyclol0104 chemical sciencesAnalytical Chemistry03 medical and health scienceschemistry.chemical_compoundCannabichromene0302 clinical medicinechemistryLiquid chromatography–mass spectrometrymedicineCannabinolSolid phase extractionmedicine.drugJournal of chromatography. B, Analytical technologies in the biomedical and life sciences
researchProduct

Analysis of post-harvest fungicides by micellar electrokinetic chromatography.

2001

A method based on solid-phase extraction (SPE) and micellar electrokinetic chromatography (MEKC) was developed for the simultaneous determination of carbendazim, imazalil, methylthiophanate, O-phenylphenol, prochloraz, procimidone, thiabendazole and triadimefon residues in grape, lettuce, orange and tomato. Selectivity and resolution were studied changing the pH and the concentration of the buffer, the type and concentration of surfactant and the methanol content in the mobile phase. A buffer consisting of 4 mM borate with 75 mM sodium cholate (pH 9.2) gave the best results. The recoveries of the fungicides in spiked fruit and vegetable samples ranged from 30 to 105%, and the limits of dete…

Detection limitChromatographyCarbendazimOrganic ChemistryReproducibility of ResultsSodium Dodecyl SulfateGeneral MedicineBuffersSodium CholateBiochemistryMicellar electrokinetic chromatographyAnalytical ChemistryFungicides IndustrialFungicidechemistry.chemical_compoundSurface-Active AgentsTriadimefonchemistryFruitSample preparationSolid phase extractionSodium CholateChromatography Micellar Electrokinetic CapillaryJournal of chromatography. A
researchProduct

On-line preconcentration strategies for analyzing pesticides in fruits and vegetables by micellar electrokinetic chromatography.

2007

Five pesticides (fludioxonil, procymidone, pyriproxyfen, dinoseb and carbendazim) were separated in reversed migration micellar electrokinetic chromatography (RM-MEKC) using 20 mmol l(-1) phosphate buffer at pH 2.3, containing 25 mmol l(-1) sodium dodecylsulfate and 10% methanol. Three on-line concentration strategies, sweeping (SW), normal stacking with reversed migration and a water plug (SRW) and stacking with reverse migration and removal of sample matrix using polarity switching (SRMM), were compared. About 10-, 30- and 50-fold increases in detection sensitivity, compared with standard hydrodynamic injection (5 s at 0.5 psi), were observed with SW, SRW and SRMM, respectively. Limits of…

Detection limitChromatographyChemistryCarbendazimOrganic ChemistryAnalytic Sample Preparation MethodsElectrophoresis CapillaryGeneral MedicineBiochemistryOnline SystemsMicellar electrokinetic chromatographyAnalytical ChemistryFungicides Industrialchemistry.chemical_compoundElectrophoresisFruitDinosebVegetablesSample preparationSolid phase extractionProcymidonePesticidesFood AnalysisChromatography Micellar Electrokinetic CapillaryJournal of chromatography. A
researchProduct

Improved Solid Phase Extraction Procedure for Assay of Cephalosporins in Human Urine Samples

1998

Abstract Solid phase extraction technique has been evaluated for the treatment of urine samples in the analysis of cephalosporins before injection into an HP-Hypersil ODS-C18 column. Cephalexin, cefotaxime, cefazolin, cefuroxime, and cefoxitin were tested with seven different reversed-phase extraction column cartridges and the obtained urine extracts were not clean. However, 3M Empore extraction disk cartridges packed with octadecyl (C18) bonded silica provided clean extracts with a single extraction. The recoveries of the five cephalosporins ranged from 56 to 60 % in the 1.25–500 g/mL concentration range. The assay was accurate, precise, and adequate for testing the drug content in urine s…

Detection limitChromatographyChemistryClinical BiochemistryExtraction (chemistry)Pharmaceutical ScienceUrineBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryCefalexinmedicineSolid phase extractionCefuroximeAntibacterial agentmedicine.drugJournal of Liquid Chromatography & Related Technologies
researchProduct

Effect of the shampoo Ultra Clean on drug concentrations in human hair

2000

The influence of the special shampoo Ultra Clean (Zydot Unlimited, Tulsa, Oklahoma) on the results of hair analyses was investigated. Hair samples from persons (n = 14) with a known history of drug abuse were collected at autopsy. The hair samples were divided into separate strands which were analyzed both after washing with Ultra Clean and without treatment. Hair analyses were performed by methanol extraction under sonication, purification by solid phase extraction and GC/MS in SIM mode according to routine procedures for tetrahydrocannabinol (THC), cocaine, amphetamine, methylenedioxyamphetamine (MDA), methylenedioxymethamphetamine (MDMA), methylenedioxyethylamphetamine (MDE), heroin, 6-m…

Detection limitChromatographyChemistryCodeineHair PreparationsMDMAForensic MedicineDihydrocodeineShampooPathology and Forensic MedicineSubstance Abuse DetectionmedicineMorphineHumansSolid phase extractionTetrahydrocannabinolHairmedicine.drugInternational Journal of Legal Medicine
researchProduct

A solid-phase extraction and size-exclusion liquid chromatographic method for polyethylene glycol 25 p-aminobenzoic acid determination in urine: Vali…

2007

No previous publications about percutaneous absorption of polyethylene glycol 25 p-aminobenzoic acid (PEG-25 PABA) have been found in the literature and the expected levels to be found in human urine after sunscreens use are unknown. The method proposed here is suitable to determine PEG-25 PABA in the urine of sunscreens users in order to carry out studies on body accumulation/excretion. It is based on solid-phase extraction (SPE) with size-exclusion liquid chromatography determination. Solid-phase extraction allows the analyte to be retained and subsequently eluted for a clean-up, using a silica-based cartridge. The size-exclusion liquid chromatography of the eluted allows the rest of matr…

Detection limitChromatographyChemistryElutionExtraction (chemistry)Fluorescence spectrometryReproducibility of ResultsUrineBiochemistryPolyethylene GlycolsAnalytical ChemistryMatrix (chemical analysis)ExcretionSpectrometry FluorescenceChromatography GelHumansEnvironmental ChemistrySolid phase extraction4-Aminobenzoic AcidSunscreening AgentsSpectroscopyAnalytica Chimica Acta
researchProduct

Determination of clenbuterol in urine by azo-dye precolumn derivatization and micellar liquid chromatography

1997

Clenbuterol has been determined in urine by solidphase extraction on a C18 cartridge, diazotization of the eluate with nitrite, coupling of the diazonium ion with 1-(naphthyl)ethylenediamine, and separation of the azo dye formed by HPLC with a C18 column and a micellar mobile phase containing 0.1 M sodium dodecyl sulphate, 12%n-butanol and 0.05 M citrate buffer, pH 3. Recoveries higher than 90% were obtained by mixing the samples with a 20% 0.2 M NaOH before extraction. Limits of detection of 51 and 6.7 ng L−1 were obtained with spectrophotometric and thermal lens spectrometric detection, respectively; respective repeatabilities were 3.1% (5 μg mL−1) and 5.6% (0.16 μg mL−1).

Detection limitChromatographyChemistryElutionOrganic ChemistryClinical BiochemistryExtraction (chemistry)Reversed-phase chromatographyBiochemistryHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundMicellar liquid chromatographySolid phase extractionDerivatizationChromatographia
researchProduct

Simultaneous detection of three antiviral and four antibiotic compounds in source-separated urine with liquid chromatography

2013

An analytical method for the simultaneous screening of three antiviral agents (nevirapine, zidovudine, lamivudine), four antibiotics (sulfamethoxazole, trimethoprim, ciprofloxacin, rifampicin) and one reference compound (carbamazepine) in human urine was developed. Separation was achieved with a Kinetex XB-C18 (75 × 4.6 mm, 2.6 μm) column after the extraction of pharmaceuticals from urine with SPE. Gradient elution with a mobile phase consisting of acetonitrile and 10 mM KH2 PO4 (pH 2.5), and diode array detection with monitoring at 210 and 264 nm was applied. The developed method was validated in terms of selectivity, linearity, stability and sensitivity. Repeatability (n = 3) and between-…

Detection limitChromatographyChemistryExtraction (chemistry)Filtration and SeparationRepeatabilityUrineHigh-performance liquid chromatographyTrimethoprimAnalytical ChemistryWastewatermedicineSolid phase extractionmedicine.drugJournal of Separation Science
researchProduct

Sensitive determination of probenecid in urine samples by reversed-phase liquid chromatography and UV-visible detection using solid-phase extraction …

1993

This study describes a rapid method for the determination of probenecid in human urine by liquid chromatography with UV detection at 254 nm, after clean-up through a C8 solid-phase extraction column. Liquid chromatography was carried out on a C18-bonded phase using an acetonitrile-acetate buffer (pH=4) gradient elution. Ethacrynic acid was used as internal standard. The system has been applied to the determination of probenecid in the 0.10–100.0 μg/ml concentration range; the limit of detection was 5 ng/mL.

Detection limitChromatographyChemistryOrganic ChemistryClinical BiochemistryExtraction (chemistry)Reversed-phase chromatographyUrineBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryProbenecidPhase (matter)medicineSolid phase extractionmedicine.drugChromatographia
researchProduct