Search results for "Solutions"
showing 10 items of 757 documents
Multiplicity results for a class of asymmetric weakly coupled systems of second order ordinary differential equations
2005
We prove the existence and multiplicity of solutions to a two-point boundary value problem associated to a weakly coupled system of asymmetric second-order equations. Applying a classical change of variables, we transform the initial problem into an equivalent problem whose solutions can be characterized by their nodal properties. The proof is developed in the framework of the shooting methods and it is based on some estimates on the rotation numbers associated to each component of the solutions to the equivalent system.
On strong solutions of the differential equations modeling the steady flow of certain incompressible generalized Newtonian fluids
2007
In this paper we discuss a system of partial differential equations describing the steady flow of an incompressible fluid and prove the existence of a strong solution under suitable assumptions on the data. In the 2D-case this solution turns out to be of class C^{1,\alpha}.
A Refractive Index Sensor Based on the Resonant Coupling to Cladding Modes in a Fiber Loop
2013
We report an easy-to-build, compact, and low-cost optical fiber refractive index sensor. It consists of a single fiber loop whose transmission spectra exhibit a series of notches produced by the resonant coupling between the fundamental mode and the cladding modes in a uniformly bent fiber. The wavelength of the notches, distributed in a wavelength span from 1,400 to 1,700 nm, can be tuned by adjusting the diameter of the fiber loop and are sensitive to refractive index changes of the external medium. Sensitivities of 170 and 800 nm per refractive index unit for water solutions and for the refractive index interval 1.40-1.442, respectively, are demonstrated. We estimate a long range resolut…
Hypertonic Stress and Amino Acid Deprivation Both Increase Expression of mRNA for Amino Acid Transport System A
2004
The activity of amino acid transport system A ([Oxender and Christensen, 1963][1]) is regulated in a variety of different ways, the best studied being the increases of its activity caused by starving cells of amino acids or by exposing them to hypertonicity (for review see [McGivan and Pastor-
Thermodynamic versus Conformational Metastability in Fibril-Forming Lysozyme Solutions
2012
The role of intermolecular interaction in fibril-forming protein solutions and its relation with molecular conformation is a crucial aspect for the control and inhibition of amyloid structures. Here, we study the fibril formation and the protein-protein interactions of lysozyme at acidic pH and low ionic strength. The amyloid formation occurs after a long lag time and is preceded by the formation of oligomers, which seems to be off-pathway with respect to fibrillation. By measuring the osmotic isothermal compressibility and the collective diffusion coefficient of lysozyme in solution, we observe that the monomeric solution is kept in a thermodynamically metastable state by strong electrosta…
Selective determination of trimethylamine in air by liquid chromatography using solid phase extraction cartridges for sampling.
2004
Abstract The selective determination of trimethylamine (TMA) in air by liquid chromatography is reported. Sampling is effected by flushing air through C18-packed solid-phase extraction (SPE) cartridges at a flow rate of 15 mL/min for 15 min. Next, TMA is desorbed from the cartridges and injected into the chromatographic system. The analyte is then selectively retained on a precolumn ( 20 mm ×2.1 mm i.d., packed with 30 μm, Hypersil C18 phase), and derivatized on-line by injecting 9-fluorenylmethyl chloroformate (FMOC). Finally, the TMA-FMOC derivative is transferred to the analytical column ( 125 mm ×4 mm i.d., LiChrospher 100 RP18, 5 μm), and monitored at 262 nm. The method was applied to …
Green aspects, developments and perspectives of liquid phase microextraction techniques.
2014
Determination of analytes at trace levels in complex samples (e.g. biological or contaminated water or soils) are often required for the environmental assessment and monitoring as well as for scientific research in the field of environmental pollution. A limited number of analytical techniques are sensitive enough for the direct determination of trace components in samples and, because of that, a preliminary step of the analyte isolation/enrichment prior to analysis is required in many cases. In this work the newest trends and innovations in liquid phase microextraction, like: single-drop microextraction (SDME), hollow fiber liquid-phase microextraction (HF-LPME), and dispersive liquid-liqu…
Application of solid-phase microextraction combined with derivatization to the enantiomeric determination of amphetamines.
2005
Abstract The utility of combining chiral derivatization and solid-phase microextraction (SPME) for the enantiomeric analysis of primary amphetamines by liquid chromatography has been investigated. Different derivatization/extraction strategies have been evaluated and compared using the chiral reagent o -phthaldialdehyde (OPA)– N -acetyl- l -cysteine (NAC) and fibres with a Carbowax-templated resin coating. Amphetamine, norephedrine and 3,4-methylenedioxyamphetamine (MDA) were used as model compounds. On the basis of the results obtained, a new method is presented based on the derivatization of the analytes in solution followed by SPME of the OPA–NAC derivatives formed. The proposed conditio…
Real-time polarimetric biosensing using macroporous alumina membranes
2013
We report the first demonstration of real-time biosensing in free standing macroporous alumina membranes. The membranes with their 200 nm diameter pores are ideal candidates for biosensing applications where fast response times for small sample volumes are needed as they allow analytes to flow through the pores close to the bioreceptors immobilized on the pores walls. A bulk refractive index sensitivity of 5.2x10 -6 refractive index units was obtained from signal responses to different concentrations of NaCl solutions flowing through the pores. Finally, after functionalizing the alumina pore surfaces with an epoxysilane and then spotting it with β-Lactoglobulin protein, the interactions bet…
More about sampling and estimation of mercaptans in air samples
2013
[EN] Several strategies have been developed for sampling and determination of volatile thiols. The selectivity and sensitivity of the proposed methodologies are achieved by using a specific derivatizing reagent. The different procedures assayed are based on air sampling followed by derivatization of the analytes with OPA and isoleucine in alkaline solution. The derivatization products are separated and determined by liquid chromatography and fluorescence detection. To start, the derivatization conditions and stability of the derivates have been studied in order to establish the storage conditions. In general, the strategies studied consisted on trapping and detivatization the thiol compound…