Search results for "Spectrometry"

showing 10 items of 3206 documents

Structure analysis of acetylated and non-acetylated O-linked MUC1-glycopeptides by post-source decay matrix-assisted laser desorption/ionization mass…

1997

We have investigated the potential of structural elucidation of O-linked glycopeptides by post-source decay matrix-assisted laser desorption ionization mass spectrometry (PSD-MALDI-MS). In order to establish detailed fragmentation patterns and to dissect fragment ions with and without carbohydrate content, the same O-linked MUC1-derived glycopeptides with acetylated and non-acetylated sugars were analysed and compared. Furthermore, we were interested to examine possible differences in the fragmentation between glycopeptides with acetylated and non-acetylated sugars. The obtained PSD-MALDI-MS spectra showed a rather complete set of fragmentation data which allows us to localize the glycan on…

chemistry.chemical_classificationGlycanbiologyStereochemistryOrganic ChemistryMucin-1CarbohydratesPeptideGlycosidic bondAcetylationMass spectrometryGlycopeptideGas Chromatography-Mass SpectrometryAnalytical ChemistryMatrix-assisted laser desorption/ionizationchemistryFragmentation (mass spectrometry)AcetylationSpectrometry Mass Matrix-Assisted Laser Desorption-Ionizationbiology.proteinOrganic chemistrySpectroscopyRapid communications in mass spectrometry : RCM
researchProduct

Chlorine loss from polyvinylchloride under neutron irradiation

1997

PVC samples were irradiated for 1 hour with a thermal neutron flux of Φ th =4.71·1011n·cm−2·s−1 and the chlorine lost during irradiation was measured by γ-ray spectrometry. About 15% of loss of chlorine has been observed for untreated samples while samples heated to temperatures of 60 and 80°C for one minute before irradiation have been found to loose about 8% and 3%, respectively. The results indicate an influence of the polymer structure on the release of chlorine.

chemistry.chemical_classificationHealth Toxicology and MutagenesisRadiochemistryPublic Health Environmental and Occupational Healthchemistry.chemical_elementPolymerMass spectrometryPollutionAnalytical ChemistryThermal neutron fluxNuclear Energy and Engineeringchemistrypolycyclic compoundsChlorineRadiology Nuclear Medicine and imagingIrradiationNeutron irradiationSpectroscopyJournal of Radioanalytical and Nuclear Chemistry
researchProduct

Size Exclusion Chromatography of Proteins on Improved Bonded Silica Columns

1985

Publisher Summary This chapter discusses the size exclusion chromatography (SEC) of proteins on improved bonded silica columns. Over the past few years, the use of high performance liquid chromatography (HPLC) has been extended to protein chemistry as a powerful separation and isolation technique. A spectrum of variants providing high resolution potential—ion exchange, reversed phase, hydrophobic interaction, affinity, and size exclusion—is available. Of these, SEC is the simplest with respect to method development and equipment design: proteins are separated according to their size in a short and predictable time span under isocratic conditions. The SEC columns are packed with micro-partic…

chemistry.chemical_classificationHydrophobic effectChromatographychemistryResolution (mass spectrometry)Phase (matter)Size-exclusion chromatographyHigh resolutionPolymerProtein chemistryHigh-performance liquid chromatography
researchProduct

Evaporation of tungsten oxides: A mass-spectrometric study of the vapour contents

1995

Abstract The evaporation of bulk oxides of WO2 and WO3 and oxidised tungsten surfaces (metallic tungsten heated in an oxygen atmosphere) have been studied by the means of mass-spectrometry. The principal constituents of the vapour are found to be molecules of WO2, WO3, W2O6 and W3O9. These results differ from earlier reports, where the presence of molecules smaller than W3O9 in the mass-spectrum was interpreted as an artifact due to electron impact dissociation of larger polymers.

chemistry.chemical_classificationInorganic chemistryAnalytical chemistrychemistry.chemical_elementPolymerTungstenequipment and suppliesCondensed Matter PhysicsMass spectrometryDissociation (chemistry)Surfaces Coatings and FilmsMetalchemistryvisual_artMass spectrumvisual_art.visual_art_mediumMoleculeInstrumentationElectron ionizationVacuum
researchProduct

Occurrence of glycine in the core oligosaccharides of Hafnia alvei lipopolysaccharides--identification of disubstituted glycoform.

2015

Endotoxins (lipopolysaccharides, LPS) are the main surface antigens and virulence factors of Gram-negative bacteria involved for example in the development of nosocomial infections and sepsis. They consist of three main regions: O-specific polysaccharide, core oligosaccharide, and lipid A. Bacteria modify LPS structure to escape the immune defence, but also to adapt to environmental conditions. LPS's structures are highly diversified in the O-specific polysaccharide region to evade bactericidal factors of immune system, but retain some common epitopes that are potential candidates for therapeutic strategies against bacterial infections. Common occurrence of glycine within the structure of L…

chemistry.chemical_classificationLipopolysaccharidesSpectrometry Mass Electrospray IonizationbiologyLipopolysaccharideOrganic ChemistryGlycineVirulenceHafnia alveiGeneral MedicinePolysaccharidebiology.organism_classificationBiochemistryEpitopeAnalytical ChemistryMicrobiologyResidue (chemistry)chemistry.chemical_compoundchemistryAntigenBiochemistryCarbohydrate SequenceGlycineBacteriaCarbohydrate research
researchProduct

Determination of major carotenoids in vegetables by capillary electrochromatography.

2006

A simple and rapid method for the isocratic separation and determination of carotenoids (carotenes and xanthophylls) in vegetables by CEC is described. The capillary column (100 microm ID, 25 cm effective length) was packed with 3 microm Hypersil ODS particles. The optimized mobile phase contained 60% ACN, 35% THF and 5% of a 5 mM Tris aqueous buffer of pH 8. beta-Carotene, lycopene and lutein were separated with efficiencies of 66 000-128 000 plates/m within a short time (less than 12 min for the last peak eluted, 13/13'-cis-beta-carotene). An excellent resolution of the three carotenoids, as well as partial resolution of their geometrical isomers, was achieved. Application to the determin…

chemistry.chemical_classificationLuteinCapillary electrochromatographyChromatographyResolution (mass spectrometry)Molecular StructureElutionReproducibility of ResultsFiltration and SeparationStereoisomerismCarotenoidsLycopeneAnalytical Chemistrychemistry.chemical_compoundElectrochromatographychemistryXanthophyllVegetablesCarotenoidChromatography Micellar Electrokinetic CapillaryJournal of separation science
researchProduct

Quantitative analysis of broad molecular weight distributions obtained by matrix-assisted laser desorption ionisation-time-of-flight mass spectrometry

1996

In order to quantify the error of matrix-assisted laser desorption ionisation (MALDI) time-of-flight (TOF) mass spectrometry in the determination of broad molecular weight distributions, different mixtures by weight of two poly(methyl methacrylate) standards were prepared. These mixtures, with well-defined bimodal molecular weight distributions were analysed by MALDI-TOF mass spectrometry using different matrices (2,4,6-trihydroxyacetophenone and 2,5-dihydroxybenzoic acid) and different cations (Li+, Na+, K+, Rb+ and Cs+) for doping the analyte. From the MALDI-TOF mass spectrometric data, the weight fractions of the two polymers of all mixtures were determined and compared to the values mea…

chemistry.chemical_classificationMALDI imagingChemistryDesorptionAnalytical chemistryPolymerTime-of-flight mass spectrometryMass spectrometryQuantitative analysis (chemistry)Capillary electrophoresis–mass spectrometrySpectroscopySurface-enhanced laser desorption/ionizationEuropean Journal of Mass Spectrometry
researchProduct

Identification of the reaction products of (2'-5')oligoadenylate synthetase in the marine sponge.

1998

Previously we reported on the presence of a high (2'-5')oligoadenylate synthetase activity in the marine sponge Geodia cydonium [Kuusksalu, A., Pihlak, A., Muller, W. E. G. & Kelve, M. (1995) Eur. J. Biochem. 232, 351-357]. The presence of (2'-5')oligoadenylates [(2'-5')A] in crude sponge extract was shown by radioimmunoassay and by their HPLC comigration with authentic (2'-5')A oligomers. In addition, the sponge (2'-5')oligoadenylates displayed biological activity, as determined by inhibition studies of protein biosynthesis in rabbit reticulocyte lysate. In the present study individual (2'-5')oligoadenylates synthesized by sponge enzyme were separated by HPLC. The exact composition of ever…

chemistry.chemical_classificationMagnetic Resonance Spectroscopy2'-5'-OligoadenylateOligonucleotideBiological activityNuclear magnetic resonance spectroscopyBiologyBiochemistryPoriferaEnzymemedicine.anatomical_structureBiochemistrychemistryReticulocyteSpectrometry Mass Matrix-Assisted Laser Desorption-IonizationPhosphodiester bondProtein biosynthesismedicine2'5'-Oligoadenylate SynthetaseAnimalsChromatography High Pressure LiquidEuropean journal of biochemistry
researchProduct

Mass spectrometrical detection of polymer particles in capsule tissue surrounding joint endoprotheses of polyethyleneterephthalate

1982

Pyrolysis mass spectrometry of synthetic high polymers is described. The method is used to detect polymer wear particles in capsule tissue surrounding endoprotheses with polyethyleneterephthalate parts. An approximation of semi-quantitative determination of the polymer wear will be discussed.

chemistry.chemical_classificationMaterials scienceClinical BiochemistryAnalytical chemistryCapsule02 engineering and technologyGeneral MedicinePolymer010402 general chemistry021001 nanoscience & nanotechnologyMass spectrometry01 natural sciences0104 chemical sciencesAnalytical ChemistryPolymer particlechemistryGeneral Materials ScienceComposite material0210 nano-technologyhuman activitiesJoint (geology)Pyrolysis mass spectrometryFresenius' Zeitschrift für analytische Chemie
researchProduct

Solution Properties of Polysarcosine: From Absolute and Relative Molar Mass Determinations to Complement Activation

2018

Polysarcosine (pSar) was one of the first polymers synthesized in a controlled living manner, but it was only recently when it was reconsidered as a promising alternative for poly(ethylene glycol) (PEG) in biomedical applications. Despite receiving more and more attention, very little is known about the solution properties of pSar, such as coil dimensions and thermodynamic interactions. In this article, we report on these properties of pSar with degrees of polymerization 50 < X-n < 400 that were prepared by controlled living ring-opening polymerization. The polymers are characterized by gel permeation chromatography (GPC), MALDI-TOF mass spectrometry, dynamic and static light scattering (SL…

chemistry.chemical_classificationMaterials sciencePolymers and PlasticsOrganic ChemistryAnalytical chemistrytechnology industry and agricultureViscometer02 engineering and technologyPolymer010402 general chemistry021001 nanoscience & nanotechnologyMass spectrometry01 natural sciences0104 chemical sciencesInorganic ChemistryGel permeation chromatographychemistry.chemical_compoundchemistryPolymerizationPEG ratioMaterials ChemistryStatic light scattering0210 nano-technologyEthylene glycol
researchProduct