Search results for "Spectrometry"

showing 10 items of 3206 documents

Stir bar sorptive-dispersive microextraction mediated by magnetic nanoparticles-metal organic framework composite: Determination of N-nitrosamines in…

2019

Abstract A new analytical method based on the recently proposed stir bar sorptive-dispersive microextraction (SBSDME) technique has been developed to determine eight hazardous N-nitrosamines in cosmetic products. As previous step, a simple clean-up is carried out with hexane to remove those highly lipophilic compounds that disturb the SBSDME step. Subsequently, SBSDME is performed by using magnetic nanoparticles–metal organic framework composite, CoFe2O4/MIL-101(Fe), as sorbent to entrap the target analytes, which are later chemically desorbed and measured by liquid chromatography–tandem mass spectrometry (LC–MS/MS). The experimental variables related to the SBSDME procedure were studied to…

AnalyteNitrosaminesSorbentLiquid Phase MicroextractionCosmetics010402 general chemistryMass spectrometry01 natural sciencesBiochemistryChemistry Techniques AnalyticalAnalytical Chemistrychemistry.chemical_compoundLimit of DetectionTandem Mass SpectrometryLiquid chromatography–mass spectrometryMagnetite NanoparticlesMetal-Organic FrameworksDetection limitChromatography010401 analytical chemistryOrganic ChemistryGeneral MedicineRepeatability0104 chemical sciencesHexanechemistryMagnetic nanoparticlesHydrophobic and Hydrophilic InteractionsChromatography LiquidJournal of Chromatography A
researchProduct

Target analysis and retrospective screening of mycotoxins and pharmacologically active substances in milk using an ultra-high-performance liquid chro…

2020

Milk is a nutritious food suitable for infants and adults, and it plays an important role in the human diet. However, it may also be a vehicle for food contaminants. In this report, we developed a method using ultra-high-performance liquid chromatography coupled with high-resolution mass spectrometry (UHPLC-Q-Exactive Orbitrap HRMS; Thermo Fisher Scientific, Waltham, MA) for simultaneous identification of target pharmacologically active substances and mycotoxins in milk. We also used the Q-Orbitrap operating in full scan mode to identify other possible drugs and microbial metabolites that occurred in samples. Fifty-six commercially available milk samples from the Italian market were analyze…

AnalyteQuEChERSTarget analysisFood ContaminationOrbitrapMass spectrometryQuechersretrospective analysiMass Spectrometrylaw.inventionmycotoxin03 medical and health scienceschemistry.chemical_compoundlawGeneticsAnimalsMycotoxinChromatography High Pressure Liquid030304 developmental biologyRetrospective Studies0303 health sciencesChromatographyultra-high-performance liquid chromatography/high-resolution mass spectrometry (UHPLC-Q-Orbitrap HRMS)pharmacologically active substanceChemistry0402 animal and dairy science04 agricultural and veterinary sciencesContaminationMycotoxins040201 dairy & animal scienceMilkItalyAnimal Science and ZoologyFood ScienceFood contaminantJournal of dairy science
researchProduct

Analytical strategies to determine quinolone residues in food and the environment

2007

23 páginas, 5 figuras, 5 tablas.

AnalyteQuinoloneSolvent extractionEnvironmental analysismedicine.drug_classPLELCFluorescence spectrometryLiquid chromatographyEnvironmentAnalytical ChemistryCapillary electrophoresisCapillary electrophoresismedicineSample preparationSolid phase extractionSpectroscopySESolid-phase extractionChromatographyMass spectrometryChemistryExtraction (chemistry)MSQuinoloneCEFoodPressurized liquid extractionBiochemical engineeringSPE
researchProduct

Science based calibration for the extraction of 'analyte-specific' HPLC-DAD chromatograms in environmental analysis

2010

Multivariate science based calibration (SBC) has been applied to the resolution of overlapped peaks in liquid chromatography with diode array detection (LC-DAD). Complex river water samples spiked with 11 pharmaceutical substances resulted in poorly resolved chromatograms containing additional peaks from interfering matrix compounds and a change in the background absorbance due to the mobile phase gradient. Applying the present multivariate approach it was possible to resolve all 11 analytes from overlapping peaks, obtaining linear calibration lines (R2 > 0.96). Recovery percentages on spiked samples ranged between 74.6 and 113.5%, which are quite satisfactory taking into account the low co…

AnalyteResolution (mass spectrometry)Adrenergic beta-AntagonistsStatistics as TopicAnalytical chemistryEnvironmentHigh-performance liquid chromatographyAnalytical ChemistryMatrix (chemical analysis)AbsorbanceRiversSCIENCE BASED CALIBRATIONSample preparationLeast-Squares AnalysisElectrodesChromatography High Pressure LiquidAnalgesicsENVIRONMENTAL ANALYSISChromatographyChemistryOtras Ciencias QuímicasExtraction (chemistry)Ciencias QuímicasDrug ResiduesStandard curveHIGH PERFORMANCE LIQUID CHROMATOGRAPHY-DIODE ARRAY DETECTION (HPLC-DAD)CalibrationMultivariate AnalysisEnvironmental PollutantsCIENCIAS NATURALES Y EXACTAS
researchProduct

Comparison between micellar liquid chromatography and capillary zone electrophoresis for the determination of hydrophobic basic drugs in pharmaceutic…

2007

[EN] The determination of highly hydrophobic basic compounds by means of conventional reversed-phase liquid chromatographic methods has several drawbacks. Owing to the characteristics of micellar liquid chromatography (MLC) and capillary electrophoresis (CE), these techniques could be advantageous alternatives to reversed-phase chromatographic methods for the determination of these kinds of compounds. The objective of this study was to develop and compare MLC and CE methods for the determination of antipsychotic basic drugs (amitryptiline, haloperidol, perphenazine and thioridazine) in pharmaceutical preparations. The chromatographic determination of the analytes was performed on a Kromasil…

AnalyteResolution (mass spectrometry)Capillary actionClinical BiochemistrySensitivity and SpecificityBiochemistryAnalytical ChemistryCapillary electrophoresischemistry.chemical_compoundCapillary electrophoresisBromideDrug DiscoveryQUIMICA ANALITICAAntipsychotic drugsMolecular BiologyPharmacologyDetection limitChromatographyElectrophoresis CapillaryReproducibility of ResultsGeneral MedicineHydrogen-Ion ConcentrationReference StandardsElectrophoresisPharmaceutical PreparationschemistryHydrophobic basic drugsMicellar liquid chromatographyCalibrationPharmaceutical analysisHydrophobic and Hydrophilic InteractionsCetyltrimethylammonium bromideMicellar liquid chromatographyAntipsychotic AgentsChromatography Liquid
researchProduct

Multivariate optimization approach for chiral resolution of drugs using human serum albumin in affinity electrokinetic chromatography-partial filling…

2005

The enantiomeric resolution of chiral compounds using HSA by means of affinity EKC (AEKC)-partial filling technique is the result of a delicate balance between different experimental variables such as protein concentration, running pH (background electrophoretic buffer, protein and compound solutions) and protein solution plug length. In this paper multivariate optimization approaches for chiral separation of four basic drugs (alprenolol, oxprenolol, promethazine and propranolol) using HSA as chiral selector in AEKC-partial filling technique are studied. The experimental conditions to achieve maximum resolution are optimized using the Box-Behnken experimental design. Partial least squares a…

AnalyteResolution (mass spectrometry)Clinical BiochemistryAnalytical chemistryBiochemistryPromethazineChromatography AffinityAnalytical ChemistryElectrokinetic phenomenaPartial least squares regressionmedicineHumansAminesAlprenololSerum AlbuminChromatographyChemistryElectrophoresis CapillaryOxprenololStereoisomerismHuman serum albuminPropranololChiral resolutionElectrophoresisPharmaceutical PreparationsMultivariate AnalysisEnantiomerHydrophobic and Hydrophilic Interactionsmedicine.drugElectrophoresis
researchProduct

Strategies for the enantiomeric determination of amphetamine and related compounds by liquid chromatography.

2002

This paper summarizes recent research on the stereospecific analysis of amphetamine, its analogs and metabolites, by liquid chromatography. The different methods proposed have been evaluated and compared in terms of resolution power, time of analysis, sensitivity, or potential for automation. Chiral derivatization, followed by separation of the diastereomers formed in achiral chromatographic systems, is still the method preferred for the analysis of amphetamines at trace levels, as derivatization also improves analyte detectability. This is the method of choice for the enantiomeric analysis of amphetamines at the low concentrations typically encountered in biological samples. In recent year…

AnalyteResolution (mass spectrometry)medicine.drug_classBiophysicsBiochemistrySensitivity and Specificitychemistry.chemical_compoundIsomerismmedicineHumansEphedrineDerivatizationAmphetamineChromatography High Pressure LiquidChromatographyStaining and LabelingIllicit DrugsAmphetaminesDiastereomerReproducibility of ResultsDesigner drugSubstance Abuse DetectionchemistryModels ChemicalEnantiomermedicine.drugChromatography LiquidJournal of biochemical and biophysical methods
researchProduct

Assessment of oxidative damage to proteins and DNA in urine of newborn infants by a validated UPLC-MS/MS approach

2014

The assessment of oxidative stress is highly relevant in clinical Perinatology as it is associated to adverse outcomes in newborn infants. This study summarizes results from the validation of an Ultra Performance Liquid Chromatography-tandem Mass Spectrometry (UPLC-MS/MS) method for the simultaneous quantification of the urinary concentrations of a set of endogenous biomarkers, capable to provide a valid snapshot of the oxidative stress status applicable in human clinical trials, especially in the field of Perinatology. The set of analytes included are phenylalanine (Phe), para-tyrosine (p-Tyr), ortho-tyrosine (o-Tyr), meta-tyrosine (m-Tyr), 3-NO2-tyrosine (3NO(2)-Tyr), 3-Cl-tyrosine (3Cl-T…

AnalyteScienceUrinary systemUrineResearch and Analysis Methodsmedicine.disease_causeTandem mass spectrometryBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryOxidative DamageTandem Mass SpectrometryDiagnostic MedicineLiquid chromatography–mass spectrometryNucleic AcidsDNA-binding proteinsMedicine and Health SciencesmedicineHumansClinical ChemistryMultidisciplinaryChromatographyBiology and life sciencesbusiness.industryQChromatographic TechniquesRInfant NewbornProteinsDNAClinical Laboratory SciencesClinical trialOxidative StressChemistryBioassays and Physiological AnalysisPhysical SciencesMedicineMedicinal ChemistryBiochemical AnalysisbusinessBiomarkersOxidative stressResearch Article
researchProduct

More about sampling and estimation of mercaptans in air samples

2013

[EN] Several strategies have been developed for sampling and determination of volatile thiols. The selectivity and sensitivity of the proposed methodologies are achieved by using a specific derivatizing reagent. The different procedures assayed are based on air sampling followed by derivatization of the analytes with OPA and isoleucine in alkaline solution. The derivatization products are separated and determined by liquid chromatography and fluorescence detection. To start, the derivatization conditions and stability of the derivates have been studied in order to establish the storage conditions. In general, the strategies studied consisted on trapping and detivatization the thiol compound…

AnalyteSorbentAir samplesAlkaliesHigh-performance liquid chromatographyAnalytical ChemistryCartridgeO-Phthalaldehydechemistry.chemical_compoundMercaptansQUIMICA ANALITICAHumansSulfhydryl CompoundsIsoleucineDerivatizationAir sampling systemFluorescent DyesAir PollutantsChromatographyAirSampling (statistics)DerivatizationSolutionsSpectrometry FluorescencechemistryReagentCalibrationHPLCo-PhthalaldehydeChromatography Liquid
researchProduct

Comparison of silica-based materials for organophosphorus pesticides sampling and occupational risk assessment.

2020

Abstract A novel air sampler has been designed containing a sorbent based on UVM-7 mesoporous silica doped with Ti. The sorbent has been applied for the determination of organophosphorus pesticides in occupational air, followed by gas chromatography with mass spectrometry detection. Thus, several silica materials with different structures (mesoporous UVM-7 and microporous xerogels) were synthesized, and modified with the addition of Ti and Fe. The structure of these materials was proved by transmission electronic microscopy, energy-dispersive X-ray, X-ray diffraction, nitrogen adsorption-desorption and UV–Vis and Raman spectroscopy. The potential of these materials for the retention of pest…

AnalyteSorbentChromatographyChemistry010401 analytical chemistrySorption02 engineering and technologyMicroporous materialMesoporous silica021001 nanoscience & nanotechnologyMass spectrometry01 natural sciencesBiochemistry0104 chemical sciencesAnalytical ChemistryEnvironmental ChemistryGas chromatography0210 nano-technologyMesoporous materialSpectroscopyAnalytica chimica acta
researchProduct