Search results for "Spectroscopy"
showing 10 items of 10293 documents
Specific Protein Docking to Chelator Lipid Monolayers Monitored by FT-IR Spectroscopy at the Air–Water Interface
1996
Multi-speckle autocorrelation spectroscopy — a new strategy to monitor ultraslow dynamics in dense and nonergodic media
2007
We present a modification of the conventional dynamic light scattering set-up which allows to monitor the intensity fluctuations of many independent spatial Fourier components of the density fluctuations, i.e. “speckles”, simultaneously by using a charge-coupled device (CCD) camera as area detector. By averaging over the intensity autocorrelation function the final 10–20% decay of the intermediate scattering function in very dense colloidal dispersions is obtained with much higher accuracy. At the same time this multi-speckle autocorrelation spectroscopy provides an alternative route for constructing ensemble-averaged intermediate scattering functions in nonergodic media by replacing the av…
Description of x-ray beams using the fluorescence yields of a set of thick targets
1995
Quantitative methods in x-ray fluorescence analysis require a knowledge of the spectral distribution of the fluorescence-exciting beam. The use of XRF yield measurements of a set of thick pure element targets is proposed for the description of a fluorescence-exciting x-ray beam, without the need to obtain its spectral distribution. This new approach is derived theoretically and verified by comparing thin-target yields calculated from XRF yield measurements of thick pure element specimens with those obtained from a calculated spectral distribution. The difference between the two methods of obtaining the thin-target yields is within 9% relative error.
Model, software and database for line-mixing effects in the nu3 and nu4 bands of CH4 and tests using laboratory and planetary measurements - II : H2 …
2006
International audience; The absorption shapes of the nu(2), nu(3) and nu(4) infrared bands of CH4 perturbed by H-2 in large ranges of pressure and temperature have been measured in the laboratory. In order to model these spectra, the theoretical approach accounting for line-mixing effects proposed for CH4-N-2 and CH4-air and successfully tested in the companion paper (1), is used. As before, state-to-state rotational rates are used together with some empirical parameters that are deduced from a fit of a single room temperature spectrum of the nu(3) band at about 50 atm. The comparisons between measured and calculated spectra in the nu(3) and nu(4) regions under a vast variety of conditions …
Rapid and Nondestructive Determination of Egg Freshness Category and Marked Date of Lay using Spectral Fingerprint
2020
The potential of nondestructive prediction of egg freshness based on near-infrared (NIR) spectra fingerprints would be beneficial to quality control officers and consumers alike. In this study, handheld NIR spectrometer in the range of 740 nm to 1070 nm and chemometrics were used to simultaneously determine egg freshness based on marked date of lay for eggs stored under cold and ambient conditions. The spectra acquired from the eggs were preprocessed using multiplicative scatter correction and principal component analysis (MSC-PCA). Linear discriminant analysis (LDA) was used to build identification model to predict the category of freshness, while partial least square regression (PLS-R) wa…
Accurate spectroscopic constants of nitrogen determined from stimulated Raman spectra of the fundamental and first hot bands
1990
Nitrogen spectra of the Q-branch of the fundamental and the first hot bands were recorde with a high-resolution stimulated Raman spectrometer at atmospheric pressure and ca. 1300 K. The absolute frequencies of the Raman lines were measured with high accuracy, leading to a refinement of spectroscopic constants. A temperature estimation was also performed from the Raman intensities.
Non-destructive and clean prediction of aviation fuel characteristics through Fourier transform-Raman spectroscopy and multivariate calibration
2003
Abstract The combination of Fourier transform (FT)-Raman spectroscopy and partial least squares (PLS) regression is proposed to be used in off-line kerosene quality control. Here, six important physico-chemical properties have been studied: Abel flash point, initial boiling point (IBP), 10% of distilled sample, final boiling point (FBP), total percentage of aromatic compounds (% aromatics) and viscosity. The Raman spectra were obtained directly from standard 2 ml glass vials ( 12 mm ×32 mm), using a Bruker RFS 100 FT-Raman spectrometer, equipped with a 1064 nm Nd:YAG laser and a Ge detector, in back-scattering mode and accumulating 25 scans (150 s acquisition time) with a laser power of 30…
Monitoring supercritical fluid extraction by thermal lens spectrometry with pulsed laser excitation
1999
Abstract A dual-beam thermal lens spectrometer (TLS) with a pulse pump–probe coaxial configuration was coupled to commercially available supercritical fluid extraction equipment using a high-pressure flow cell interface. Because of its feasible critical parameters, moderate cost and good thermooptical properties, carbon dioxide was used as supercritical solvent. Using trans -β-carotene as analyte, several factors related with the extraction process under continuos flow conditions were studied in order to establish their influence in the thermal lens signal magnitude. Under the optimum experimental conditions, the relative TLS signal area showed a linear relationship with the concentration o…
High-resolution stimulated Raman spectroscopy and analysis of the ν 1 , 2ν 1 -ν 1 , ν 2 , 2ν 2 , and 3ν 2 -ν 2 bands of CF4
2013
The spectra of the ν1, 2ν1–ν1, ν2, 2ν2, and 3ν2–ν2 bands of CF4 were obtained with a quasi-continuous wave stimulated Raman spectrometer. These five bands were studied at a temperature of 135 and 300 K (for the hot bands). The spectrum of ν1 was obtained at a sample pressure of 2 mbar. For the spectra of the other regions, which are much weaker, higher pressures were used. The analysis has been performed thanks to the xtds and spview softwares developed in Dijon for such highly symmetric molecules. Combining the present results with a previous infrared study, we could determine a very accurate value for the C–F equilibrium bond length, i.e. re = 1.31588(6) A. Copyright © 2013 John Wiley & S…
High-resolution spectroscopy of the ν3 band of WF6 and ReF6 in a supersonic jet
2002
We have recorded the Fourier-transform infrared (FTIR) spectrum of the ν3 fundamental band of WF6 in a continuous supersonic jet expansion with an instrumental bandwidth of 0.0024 cm−1 (FWHM, full width at half maximum, unapodized), using a Bomem DA.002 spectrometer. Some parts of this band have also been recorded with 0.0007 cm−1 bandwidth using a diode laser spectrometer combined with a pulsed slit jet expansion. A multiple-pass arrangement has been used for the slit jet to observe low-intensity lines. In each case, we have used a WF6:He mixture with a seeding ratio 1:3 leading to a rotational temperature of ca. 50 K. This work extends the previous investigation of Takami and Kuze [J. Che…