Search results for "Standards"
showing 10 items of 394 documents
Processing of Generator-Produced 68Ga for Medical Application
2007
The (68)Ge/(68)Ga generator provides an excellent source of positron-emitting (68)Ga. However, newly available "ionic" (68)Ge/(68)Ga radionuclide generators are not necessarily optimized for the synthesis of (68)Ga-labeled radiopharmaceuticals. The eluates have rather large volumes, a high concentration of H(+) (pH of 1), a breakthrough of (68)Ge, increasing with time or frequency of use, and impurities such as stable Zn(II) generated by the decay of (68)Ga, Ti(IV) as a constituent of the column material, and Fe(III) as a general impurity.We have developed an efficient route for the processing of generator-derived (68)Ga eluates, including the labeling and purification of biomolecules. Prec…
Univariate method for background correction in liquid chromatography–Fourier transform infrared spectrometry
2007
An univariate method is proposed for background correction in on-line gradient liquid chromatography-Fourier transform infrared (LC-FTIR) spectrometry using acetonitrile:water as mobile phase components. The method is based on the calculation of the ratio of absorbances (AR) at two characteristic wavenumbers for each spectrum. This parameter is subsequently used to locate the most appropriated eluent spectrum within a reference spectra matrix (RSM) to be subtracted from each spectrum included in the sample chromatogram. To correct minor changes in eluent spectra intensity during the elution of analytes, a correction factor (Kf), defined as the ratio of the absorbance of the sample and the s…
Extraction of clenbuterol from calf urine using a molecularly imprinted polymer followed by quantitation by high-performance liquid chromatography wi…
2002
A method for the extraction of clenbuterol from calf urine samples using a molecularly imprinted polymer (MIP) has been developed. The aim was that the final extracts from the MIP should allow quantitation of clenbuterol down to 0.5 ng/mL urine using HPLC with UV detection. The MIP was produced using brombuterol as a template and the selectivity of the MIP, for clenbuterol, was tested against a non-imprinted polymer (produced without template) and was found to be high. After loading of 5 mL diluted centrifuged urine, selective binding was established in acetonitrile-acetic acid (98:2). For further elution of interferences, 0.5 M ammonium acetate buffer pH 5 and 70% acetonitrile in water was…
Determination of busulfan in human plasma using high-performance liquid chromatography with pre-column derivatization and fluorescence detection.
1999
A rapid, sensitive and reproducible high-performance liquid chromatographic assay for busulfan in human plasma was developed. After extraction of plasma samples with acetonitrile and methylene chloride, busulfan and the internal standard [1,5-bis(methanesulfonyloxy)pentane] were derivatized with 8-mercaptoquinoline to yield fluorescent compounds which were detected with a fluorescence detector equipped with filters of 360 nm (excitation) and 425 nm (emission). Calibration graphs showed a linear correlation (r>0.9990) over the concentration range of 20-2000 ng/ml. The recovery of busulfan from plasma standards was 70+/-5%. The detection and quantification limits for busulfan in plasma sample…
Emerging approaches to estimate retention factors in high performance liquid chromatography.
2004
The retention factor is one of the most universally used parameters in chromatography. The errors associated with the conventional ways to determine the retention factor of compounds in liquid chromatography are studied and compared with those corresponding to new approaches. The later avoid the use of extra-column time and hold-up time values, which have proven to be tedious and ambiguous. Simulations and real data, used to examine the accuracy of four different approaches (two classic and two new), suggest that the new approaches could be considered more satisfactory than the classic ones.
Development of standard operation procedures for the manufacture of n-octadecyl bonded silicas as packing material in certified reference columns for…
2004
The development of standard operation procedures for the manufacture of a n-octadecyl bonded spherical silica packing from partially condensed tetraethoxysilane as silica source is described. The synthesis comprises five intermediate products and six synthesis steps which were examined according to their reproducibility and robustness. The results led to the optimisation of the manufacturing process for a n-octadecyl bonded silica. Correlations were drawn between the dynamic viscosity of the poly(ethoxy)siloxane (PES), the synthesis parameters, the resulting pore structural properties and particle size distribution of the silicas. Validated procedures were developed to manufacture spherical…
Identification of diterpenes in canvas painting varnishes by gas chromatography-mass spectrometry with combined derivatisation.
2004
A derivatisation method that combines the formation of ethyl esters from the carboxylic groups and trimethylsilyl ethers from hydroxyl groups of the components of diterpenic resins is presented in this paper. This methodology involves two experimental steps: (1) formation of ethyl esters using ethyl chloroformate; and (2) the esterified compounds are lead to react with trimethylsilylimidazole to form the corresponding trimethylsilyl ethers. The main advantage of the proposed method is the possibility of performing simultaneously the analysis of amino acids from proteins, fatty acids from drying oils, and diterpenic compounds from natural resins usually found in works of art. This methodolog…
Influence of oscillating main flow on separation efficiency in asymmetrical flow field-flow fractionation.
2021
The steadily rising interest in the investigation of interactions between nanomaterials and biological media has also led to an increasing interest in asymmetrical flow field-flow fractionation (AF-FFF). The biggest strength of AF-FFF is the possibility to alter the flow profiles to suit a specific separation problem. In this paper, the influence of an oscillating main flow on the separation efficiency of AF-FFF is investigated. Such oscillations can e.g. be caused by the main pump To investigate the influence of such flow conditions on the separation efficiency in AF-FFF systematically, different oscillation profiles were applied and their influence on the elution profile and the retention…
Rapid and simultaneous high-performance liquid chromatography assay of polyamines and monoacetylpolyamines in biological specimens
2000
A rapid, resolutive and reproducible reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed for polyamines and acetylpolyamines by adopting pre-column derivatization with benzoyl chloride. In a single run lasting less than 15 min ten polyamines were separated as well as traces of benzoic acid, methylbenzoate and benzoic anhydride. These contaminants, produced during the derivatization reaction, were almost all eliminated by washing steps envisaged in the same procedure. This simple and sensitive method can be applied to routine determination of polyamines in biological samples. A fine application of this procedure to the determination of endogenous content of p…
HL7v3 CDA Rel.2 Patient Summary and Chronic Care Model: Localization experience and GP/HS Integration Project
2010
The localization experience for the Patient Summary, based on the Health Level Seven Version 3 (HL7v3) Clinical Document Architecture, Release 2 (CDA Rel.2), is presented. An overview of the Chronic Care Model (CCM) is introduced with particular attention to the clinical information systems, in order to organize patient and population clinical data by sharing information among healthcare providers in management of chronic diseases. We propose, as case study, a project for the integration of various services for General Practitioners (GP) and Hospital Specialists (HS), accessing the Electronic Health Record (EHR), implementing the Patient Summary and managing the exchange of Chronic Care med…