Search results for "Voltage"
showing 10 items of 934 documents
Dynamic performance enhancement of AC/DC PFC boost converters by means of MRAS observers
2015
Controlling a Power Factor Corrected (PFC) boost converter is not a trivial task, because the higher the dynamic performance, the higher is the input current distortion. On the other hand, recent applications of these converters require fast transients in response to disturbances, such as sudden variations of load power, reference voltage and input voltage. Better performance can be obtained adding a feedforward action to the traditional control scheme, using observers to estimate the input voltage and the output current. However, the actual improvement depends on the dynamic performance of the chosen observers. This paper aims at evaluating the applicability and the performance of differen…
Comparison of power quality impact of different photovoltaic inverters- the viewpoint of the grid
2005
This paper presents the results of an experimental analysis performed with the aim of evaluating the effect of many photovoltaic plants on power quality of the grid. Several parameters as voltage and current distortion, flicker, voltage variations at fundamental frequency and power factor have been observed. The measured values have been compared with the limits reported in the standards and, when possibiIe, their dependence on the characteristics of the grid in terms of its impedance has been pointed out.
A parametric study on unbalanced three phase islanded microgrids with inverter interfaced units
2013
In this paper, the solution of the power flow for unbalanced three phase microgrids systems is proposed. The study aims at the integration of inverter interfaced units using the control law used for primary voltage and frequency regulation, so as to take into account possible small variations of these parameters to account for sudden load changes. The proposed study deals with unbalanced systems which is the typical case of small distribution systems and shows how the power losses term varies as the regulators parameters vary as well, thus showing that these are sensitive parameters that could have an important role in optimal management of such systems.
Disturbing Load Detection in Three-Wire and Four-Wire Systems Based on Novel Nonactive Powers From IEEE 1459-2000
2010
This paper presents an enhanced approach for the detection of disturbing loads in distorted and/or unbalanced three-phase power systems, both three-wire and four-wire. It is based on the IEEE Std. 1459-2000 effective apparent power resolution, and it requires only the separation of the fundamental components of voltage and current from the remaining harmonic content. In this paper, the formulation of the novel approach is given, and its effectiveness is discussed by means of several simulation tests, which were carried out on a simple test system.
A virtual instrument for the measurement of IEEE Std 1459-2000 power quantities
2006
In this paper, the authors present a PC-based instrument for the measurement of electrical-power quantities defined in IEEE Std. 1459. The instrument is based on a time-domain technique for the detection of the fundamental and harmonic components of voltages and currents. The time-domain strategy was originally developed by the authors for three-phase, three-wire systems. In that paper, the strategy had been extended to both three-phase, four-wire and single-phase systems. Simulation tests were carried out to assess the uncertainty contribution of the proposed strategy in the absence of the measurement transducers. Moreover, the accuracy of the PC-based instrument with its transducers was e…
An harmonic test condition for the metrological characterization and the operating principle identification of reactive static meters
2008
This paper faces the problem of the metrological characterization of the static meters for reactive energy in the presence of harmonic distortion. Starting from the only available accuracy test condition in the presence of harmonics introduced in the Standards for active static meters, an experimental approach is proposed for the verification of such meters in the presence of harmonic distortion, as well as for the individuation of their operating principle. A theoretical validation of the obtained results is presented by means of a comparison with a standard and a commercial static meter with a known operating principle.
Static meters for the reactive energy in the presence of harmonics: an experimental metrological characterization
2009
Electricity metering plays a crucial role for all the commercial transactions on the energy market. Thus, an accurate evaluation of the performance of the electricity metering equipment is required not only in the reference operating conditions but also in the presence of disturbances affecting the power systems. As regards this matter, this paper analyzes the main aspects related to the metrological characterization of the static meters for the reactive energy in the presence of harmonic distortion. Attention is focused not only to the meters covered by the current standards but also to the meters of better accuracy and to the reference standard meters. The analysis is supported by several…
Influence of MV distribution networks structure on voltage dips propagation
2003
In this paper, transient behaviour due to voltage dips which occur in electric power MV distribution networks as a consequence of a fault by using an improved ATP circuit-breaker model are reported. The circuit-breaker is simulated by using a tool written in MODELS language and by arranging a time-variable differential arc-conductance based on the combination of Mayr's and Cassie's equations. An accurate analysis of the transient subsequent to circuit-breaker operation, in different fault conditions, are reported in order to show how the amplitude of the dip depends on the fault type, location and network structure.
Control of an open-end winding induction machine via a two-output indirect matrix converter
2014
In this paper an Indirect Matrix Converter (IMC) with two output stages feeding an open-end winding induction machine is presented. The IMC has the advantage of having nobulky energy storage elements and with the two output stages up to 1.5 times the input phase voltage can be obtained across the windings of the machine, without overmodulation. A vector control scheme for the machine currents is used along with a modulation strategy for the converter two-output stages to reduce the common mode voltage and compensate the phase zero sequence currents. Simulation results showing the performance of the controlscheme and the reduction of zero sequence and common mode voltages are presented and d…
A PC-based wattmeter for accurate measurements in sinusoidal and distorted conditions: Setup and experimental characterization
2012
This paper presents the development of a high-accuracy sampling wattmeter, which can be employed with both sinusoidal and distorted input signals. The proposed personal computer (PC)-based system is a simple, portable, and low-cost solution because it is based on two commercial data acquisition boards connected to a common PC. Owing to this solution, the voltage is sensed directly, avoiding expensive voltage dividers, while the current is sensed by means of a noninductive current shunt. Commercial software is also used for data processing and implementation of the virtual instrument. The setup of the PC-based wattmeter is described, with a detailed description of the correction strategy of …