Search results for "Voltage"
showing 10 items of 934 documents
Electrical Safety Analysis in the Presence of Resonant Grounding Neutral
2019
The resonant grounding is one of the possible methods of the system neutral grounding for the medium voltage distribution. IEEE standards do define this grounding configuration, but important advantages and drawbacks of the resonant grounding might not be fully known, due to its rather uncommon application in North America. On the other hand, resonant grounding in Europe is imposed by the increased requirements for power quality, especially for medium-voltage (MV) industrial users, imposed to electric utilities by regulatory authorities, with the purpose to protect the interests of users and consumers. Level of the continuity of the service, magnitude and phase of ground-fault currents, mag…
Performance Improvement of Grid-Integrated Doubly Fed Induction Generator under Asymmetrical and Symmetrical Faults
2023
The doubly fed induction generator (DFIG)-based wind energy conversion system (WECS) suffers from voltage and frequency fluctuations due to the stochastic nature of wind speed as well as nonlinear loads. Moreover, the high penetration of wind energy into the power grid is a challenge for its smooth operation. Hence, symmetrical faults are most intense, inflicting the stator winding to low voltage, disturbing the low-voltage ride-through (LVRT) functionality of a DFIG. The vector control strategy with proportional–integral (PI) controllers was used to control rotor-side converter (RSC) and grid-side converter (GSC) parameters. During a symmetrical fault, however, a series grid-side converter…
A Model for the Study of Sheath Currents in Medium Voltage Cables for Industrial Application
2020
In this paper, the implementation of a simulation model for studying the effect of cross-bonding of metallic sheaths and/or non-magnetic armor of single-core medium voltage cables in the same circuit is discussed. With the use of single-core cables, the resistive losses due to the induced circulating currents in cable sheaths or armors causes an increase of cable temperature that reduces its ampacity. In addition, the risk of electric shock due to induced voltages may be present if a person is exposed to the armor/sheath at the unbounded end. For this reason, special bonding techniques are used to significantly reduce these currents. The authors have implemented a model that could be used t…
Charge Transport Mechanisms in Heavy-Ion Driven Leakage Current in Silicon Carbide Schottky Power Diodes
2016
Under heavy-ion exposure at sufficiently high reverse bias voltages silicon carbide (SiC) Schottky diodes are observed to exhibit gradual increases in leakage current with increasing ion fluence. Heavy-ion exposure alters the overall reverse current-voltage characteristics of these diodes, leaving the forward characteristics practically unchanged. This paper discusses the charge transport mechanisms in the heavy-ion damaged SiC Schottky diodes. A macro model, describing the reverse current-voltage characteristics in the degraded SiC Schottky diodes is proposed. peerReviewed
PQ and Harmonic Assessment Issues on Low-Cost Smart Metering Platforms: A Case Study
2020
This paper presents a feasibility study on how to implement power quality (PQ) metrics in a low-cost smart metering platform. The study is aimed at verifying the possibility of implementing PQ monitoring in distribution networks without replacing existing smart metering devices or adding new modules for PQ measurements, thus zeroing the installation costs. To this aim, an electronic board, currently used for remote energy metering, was chosen as a case study, specifically the STCOMET platform. Starting from the specifications of this device, the possibility of implementing power quality metrics is investigated in order to verify if compliance with standard requirements for PQ instruments ca…
The Industrial Applicability of PEA Space Charge Measurements, for Performance Optimization of HVDC Power Cables
2019
Cable manufacturing industries are constantly trying to improve the electrical performance of power cables. During the years, it was found that one of the most relevant degradation factors influencing the cable lifetime is the presence of space charge in the insulation layer. To detect the accumulated charge, the pulsed electro-acoustic (PEA) method is the most used technique. Despite the wide use of the PEA cell, several issues are still present. In particular, the PEA output signal is strongly disturbed by the acoustic waves reflections within the PEA cell. This causes the distortion of the output signal and therefore the misinterpretation of the charge profiles. This, in turn, may result…
Comparison of local electrochemical impedance measurements derived frombi-electrode and microcapillary techniques
2009
Abstract In the present paper, local electrochemical impedance spectra were obtained on a 316L stainless steel from two configurations: a dual microelectrode (bi-electrode) and microcapillaries. With the bi-electrode, the local impedance measurements were made from the ratio of the applied voltage to the local current density calculated from the application of the ohm's law. With the use of microelectrochemical cells, the specimen surface area in contact with the electrolyte is limited by the use of glass microcapillaries and the local impedance was defined from the ratio of the local potential to the local current restricted to the analysed surface area. Differences and similarities observ…
Biased graph walks for RDF graph embeddings
2017
Knowledge Graphs have been recognized as a valuable source for background information in many data mining, information retrieval, natural language processing, and knowledge extraction tasks. However, obtaining a suitable feature vector representation from RDF graphs is a challenging task. In this paper, we extend the RDF2Vec approach, which leverages language modeling techniques for unsupervised feature extraction from sequences of entities. We generate sequences by exploiting local information from graph substructures, harvested by graph walks, and learn latent numerical representations of entities in RDF graphs. We extend the way we compute feature vector representations by comparing twel…
Bias and temperature dependence analysis of the tunneling current of normal metal-insulator-normal metal tunnel junctions
2003
Pyrrethroid resistance in Varroa destructor: Investigating the role of mutations in the voltage-gated sodium channel
2022
Entre les majors amenaces de l'apicultura contemporània es troba el parasitisme de Varroa destructor, Anderson & Trueman (Acari: Varroidae). Aquest àcar ectoparàsit altament especialitzat s'alimenta directament de les pupes i els adults de l'abella mel·lífera europea, Apis mellifera L. (Hymenoptera: Apidae), la qual cosa debilita greument a les abelles i les indueix una immunosupressió que desemboca en brots d'infeccions preexistents o vectorizades pels àcars que comprometen la viabilitat de les colònies. El control dels àcars V. destructor es un problema agreujat pel limitat número de tractaments de control disponibles i l'evolució de la resistència a aquests en les poblacions d'àcars. Enc…