Search results for "absorptio"

showing 10 items of 2815 documents

New antineutrino energy spectra predictions from the summation of beta decay branches of the fission products

2012

In this paper, we study the impact of the inclusion of the recently measured beta decay properties of the $^{102;104;105;106;107}$Tc, $^{105}$Mo, and $^{101}$Nb nuclei in an updated calculation of the antineutrino energy spectra of the four fissible isotopes $^{235, 238}$U, and $^{239,241}$Pu. These actinides are the main contributors to the fission processes in Pressurized Water Reactors. The beta feeding probabilities of the above-mentioned Tc, Mo and Nb isotopes have been found to play a major role in the $\gamma$ component of the decay heat of $^{239}$Pu, solving a large part of the $\gamma$ discrepancy in the 4 to 3000\,s range. They have been measured using the Total Absorption Techni…

FissionFOS: Physical sciencesGeneral Physics and Astronomy[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciences7. Clean energyHigh Energy Physics - ExperimentNuclear physicsHigh Energy Physics - Experiment (hep-ex)High Energy Physics - Phenomenology (hep-ph)Double beta decay0103 physical sciences[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]Absorption (logic)Nuclear Experiment (nucl-ex)Decay heat010306 general physicsNuclear ExperimentPhysicsFission productsIsotope010308 nuclear & particles physicsPandemonium effectBeta decay3. Good healthHigh Energy Physics - Phenomenology[PHYS.HPHE]Physics [physics]/High Energy Physics - Phenomenology [hep-ph]Física nuclear
researchProduct

Short and Medium Range Order in Se1-xTexGlasses

1997

Complementary XAFS measurements (LURE and NSLS) of Se 1 - x Te x glasses have been carried out on both the Se and Te K-edges at low and room temperatures. Using a multi-shell best fit analysis procedure, we have reconstructed the Se and Te local environment: (i) first shell intrachain nearest neighbors (Se-Se 1 , Se-Te 1 , Te-Se 1 ,and Te-Te 1 ); (ii) second shell intrachain (Se-Se 2 and Se-Te 2 ) and interchain next nearest neighbors (Se⇔Se 3 single scattering in the chains Se-Se 1 -Se 3 and Se-Te 1 -Se 3 ). For the first and second coordination shells we suggest that the intrachain chemical order increases with Te content. On the other hand, we propose a model of random distribution of Se…

Fit/gap analysisExtended X-ray absorption fine structureScatteringChemistryShell (structure)General Physics and AstronomyMineralogy01 natural sciencesMolecular physics3. Good health010305 fluids & plasmasX-ray absorption fine structure[PHYS.HIST]Physics [physics]/Physics archivesMedium range0103 physical sciencesOrder (group theory)Solid solutionLe Journal de Physique IV
researchProduct

New Acoustic Test Chambers at the University of Palermo

2008

Acoustic test chambers at the University of Palermo have been completed after a design optimization of existent building structures. A unique building houses five reverberation chambers, differently coupled each other in order to achieve a large flexibility on testing procedures, and offices for the staff. Main measurements offered to national and international standards include determination of sound power, sound insulation and sound absorption. Reverberation chambers present peculiar geometries in order to achieve the desidered sound fields. Chambers structure and layout within the whole building, housing all the acoustic facilities, has been designed in order to achieve strong sound insu…

Flexibility (engineering)geographyAbsorption (acoustics)Reverberationgeography.geographical_feature_categorySettore ING-IND/11 - Fisica Tecnica AmbientaleAcoustics and UltrasonicsComputer scienceAcousticsSound powerTest (assessment)SoundproofingArts and Humanities (miscellaneous)Reverberation room design: theory applications to measurements of sound absorption transmission loss sound powerSound (geography)
researchProduct

Dynamical Stark Effect in the nu(2)/nu(4) Vibrational Polyad of SiH(4): Theory and Observation.

2000

We report a theoretical and experimental investigation of the dynamical Stark effect in a tetrahedral molecule, silane (SiH(4)). We use a tetrahedral formalism and Floquet theory to calculate the absorption spectra for the molecule dressed by an intense nonresonant pulsed laser. Experimentally, the dynamical Stark effect is observed for transitions of the nu(2)/nu(4) vibrational polyad of SiH(4) by means of nanosecond diode laser absorption spectroscopy and a Nd:YAG laser excitation. Copyright 2000 Academic Press.

Floquet theoryAbsorption spectroscopyTRANSITIONS01 natural sciences010305 fluids & plasmaslaw.inventionsymbols.namesakeMOLECULESOpticslawDIPOLE-MOMENT0103 physical sciences3-LEVEL SYSTEMMoleculeSPECTRAPhysical and Theoretical Chemistry010306 general physicsSpectroscopyPhysicsbusiness.industryTetrahedral molecular geometryNanosecondRESONANCELaserAtomic and Molecular Physics and Optics3. Good healthStark effectDYADsymbolsAtomic physicsbusinessExcitationJournal of molecular spectroscopy
researchProduct

Extension of the dynamic range of flame atomic absorption spectrometry using flow injection analysis with variable-volume dilution chambers

1996

Abstract A simple and inexpensive procedure is proposed for the extension of the dynamic range of flame atomic absorption spectrometry measurements using on-line dilution. The proposed methodology is based on the use of a manifold with two coupled dilution chambers and a zone injection system. The samples are prediluted in a closed system which includes a variable-volume mixing chamber (10–120 ml) and two injection valves. The samples are injected through one of these valves, and the other is employed to take 100 μl of prediluted samples which are then passed through a new dilution chamber (volume 1–10 ml) and aspirated by the nebulizer of the instrument. A third injection valve mounted in …

Flow injection analysisChemistryInstrumentationAnalytical chemistryStandard solutionAtomic and Molecular Physics and OpticsAnalytical ChemistryDilutionlaw.inventionStandard curveNebulizerVolume (thermodynamics)lawAtomic absorption spectroscopyInstrumentationSpectroscopySpectrochimica Acta Part B: Atomic Spectroscopy
researchProduct

Determination of essential metals in complete diet feed by flow injection and flame atomic absorption spectrometry

2002

A prior study of different sample pre-treatments for the determination of metallic elements in complete diet feeds was performed in order to choose the most suitable for these samples. The studied pre-treatment were: acid extraction (lixiviation), wet digestion (on microwave oven) and dry ashing mineralization (calcination). Lixiviation (acid extraction) with hydrochloric acid was selected due to its accuracy, fast and simple pre-treatment procedure. Due of the different levels of concentration of the metallic elements in the samples, the same manifold was used but with small variations. Copper (with on-line pre-concentration by chelating Chelex-100 resin), calcium (with on-line dilution) a…

Flow injection analysisChromatographyMicrowave ovenExtraction (chemistry)Analytical chemistryHydrochloric acidAnalytical Chemistrylaw.inventionDilutionchemistry.chemical_compoundchemistryAshinglawSample preparationAtomic absorption spectroscopySpectroscopyMicrochemical Journal
researchProduct

Determination of cyanide by a flow injection analysis-atomic absorption spectrometric method

1999

A new flow injection analysis (FIA) procedure is proposed for the indirect atomic absorption spectrometric determination of cyanide. The FIA manifold is based on the insertion of the sample into a distilled water carrier, then the sample flows through a solid-phase reactor filled with silver iodide entrapped in polymeric resin beads. The calibration graph is linear over the range 0.2-6.0 mg l-1 of cyanide (correlation coefficient 0.9974), the detection limit is 0.1 mg l-1, the sample throughput is 193 h-1 and the RSD is 0.8%. The method is simple, quick and more selective than other published FIA procedures. The reproducibility obtained by using different solid-phase reactors and solutions …

Flow injection analysisDetection limitCyanidesChromatographymedicine.diagnostic_testChemistryCalibration curveSpectrophotometry AtomicCyanideSilver iodideAnalytical chemistryBiochemistryAnalytical Chemistrylaw.inventionchemistry.chemical_compoundDistilled waterlawSpectrophotometryFlow Injection AnalysisElectrochemistrymedicineEnvironmental ChemistryAtomic absorption spectroscopySpectroscopyThe Analyst
researchProduct

Flow injection spectrophotometric determination of lead using 1,5-diphenylthiocarbazone in aqueous micellar

2009

A simple flow injection colorimetric procedure for determining lead was established. It is based on the reaction of lead in sulfuric acid with 1,5-diphenylthiocarbazone and sodium dodecyl sulfate, resulting in an intense red-blue complex with a suitable absorption at 500 nm. A standard or sample solution was injected into the sulfuric acid stream (flow rate of 2.0 ml min(-1)), which was then merged with sodium dodecyl sulfate stream (flow rate of 2.0 ml min(-1)) and 1,5-diphenylthiocarbazone stream (flow rate of 1.5 ml min(-1)). Optimum conditions for determining lead were investigated by univariate method. Under the optimum conditions, a linear calibration graph was obtained over the range…

Flow injection analysisDetection limitTime FactorsAqueous solutionChromatographyCalibration curveAnalytical chemistryColorReproducibility of ResultsSodium Dodecyl SulfateWaterSulfuric acidSulfuric AcidsAbsorptionAnalytical ChemistryVolumetric flow rateStandard curvechemistry.chemical_compoundLeadchemistryDithizoneSpectrophotometryFlow Injection AnalysisSodium dodecyl sulfateMicellesTalanta
researchProduct

Rapid on-line sample dissolution assisted by focused microwave radiation for silicate analysis employing flame atomic absorption spectrometry: iron d…

2004

An on-line automated flow injection system with microwave-assisted sample digestion was used to perform silicate rock dissolution in acid medium for iron determination. For this purpose, a continuous flow system was built up by using an automatic flow injection analysis (FIA) system coupled to a flame atomic absorption spectrometer (FAAS), including a focused microwave oven unit. Inside the microwave cavity was inserted a polytetrafluoroethylene (PTFE) reactor coil (300cm length and 0.8mm i.d.) where the dissolution takes place. Chemical and flow variables as well as iron determination parameters were studied. In the flow system, a slurry of the rock sample (50mg in 200ml of acid mixture HF…

Flow injection analysisDetection limitlawChemistryMicrowave ovenAnalytical chemistrySlurryAtomic absorption spectroscopyDissolutionMicrowaveAnalytical ChemistryMicrowave cavitylaw.inventionTalanta
researchProduct

Direct determination of calcium, magnesium, sodium and potassium in water by flow injection flame atomic spectroscopy, using a dilution chamber

1989

A simple procedure to carry out the direct analysis of calcium, magnesium, sodium and potassium in water by flow injection analysis (FIA) using flame atomic absorption spectroscopy (AAS) or flame photometry (FP) has been developed, using a well stirred dilution chamber to extend the calibration range, and both a double injector and the merging zone technique to add a lanthanum solution to samples and standards. The results obtained in the analysis of real samples agree with those found by a batch flame atomic procedure. The use of the dilution chamber makes it possible to carry out the calibration using the dilution profile of a single concentrate standard for each element, and an empirical…

Flow injection analysisMagnesiumSodiumPotassiumClinical BiochemistryAnalytical chemistrychemistry.chemical_elementGeneral MedicineAtomic spectroscopyAnalytical Chemistrylaw.inventionDilutionchemistrylawLanthanumGeneral Materials ScienceAtomic absorption spectroscopyFresenius' Zeitschrift für analytische Chemie
researchProduct