On-line sample treatment and FT-IR determination of doxylamine succinate in pharmaceuticals
2005
Abstract A low solvent consumption method for Fourier transform infrared spectroscopy (FT-IR) determination of doxylamine succinate in pharmaceuticals has been developed. The analyte was continuous and selectively extracted with a 13% (v/v) ethanol:chloroform solvent mixture, recirculating the solvent through the sample and monitoring the process by FT-IR. Doxylamine succinate was determined by on-line standard addition measuring the peak area in the regions 1730–1710 and 1485–1462 cm −1 corrected with a two-point baseline established between 2000 and 1800 cm −1 . This new method implies low volumes of chloroformic solvent mixture, only 2.6 mL per sample, in front of classical batch FT-IR m…
Dispersive solid-phase extraction based on oleic acid-coated magnetic nanoparticles followed by gas chromatography-mass spectrometry for UV-filter de…
2011
Abstract A sensitive analytical method to concentrate and determine extensively used UV filters in cosmetic products at (ultra)trace levels in water samples is presented. The method is based on a sample treatment using dispersive solid-phase extraction (dSPE) with laboratory-made chemisorbed oleic acid-coated cobalt ferrite (CoFe 2 O 4 @oleic acid) magnetic nanoparticles (MNPs) as optimized sorbent for the target analytes. The variables involved in dSPE were studied and optimized in terms of sensitivity, and the optimum conditions were: mass of sorbent, 100 mg; donor phase volume, 75 mL; pH, 3; and sodium chloride concentration, 30% (w/v). After dSPE, the MNPs were eluted twice with 1.5 mL …
Application of matrix solid-phase dispersion to the determination of a new generation of fungicides in fruits and vegetables.
2002
A method based on matrix solid-phase dispersion (MSPD) and gas chromatography to determine eight fungicides in fruits and vegetables is described. Fungicide residues were identified and quantified using nitrogen-phosphorus detection and electron-capture detection connected in parallel and confirmed by mass spectrometric detection. The method required 0.5 g of sample, C18 bonded silica as dispersant sorbent, silica as clean-up sorbent and ethyl acetate as eluting solvent. Recoveries from spiked orange, apple, tomato, artichoke, carrot and courgette samples ranged from 62 to 102% and relative standard deviations were less than 15% in the concentration range 0.05-10 mg kg(-1). Detection and qu…
Selection of sampling adsorbents and optimisation and validation of a GC-MS/MS method for airborne pesticides
2017
ABSTRACTA methodology for the sampling and determination of airborne pesticides has been developed. The trapping efficiency of three adsorbents, namely XAD-2,XAD-4 and a sandwich sorbent (PUF-XAD2-PUF), was tested for 34 pesticides and the latter was selected because it presented the highest retention capacity without breakthrough. Pesticides were determined by gas chromatography coupled to an ion trap mass spectrometer in tandem. The method showed recoveries ranging from 70% to 120% with limits of quantification in the range of 16.1–322.6 pg m−3 when 155 m3 were sampled. This analytical strategy was applied to 10 indoor air samples collected in dwellings from the Valencian Region. Six pest…
Sample preparation strategies for the determination of psychoactive substances in biological fluids
2020
This review focuses on the existing analytical procedures for the determination of new psychoactive substances (NPS) in biological fluids by chromatographic methods. Direct analysis of samples is scarcely employed and most proposed methodologies include a sample pre-treatment in order to remove matrix interferents and, in some cases, pre-concentrate extracts. Current extraction methods for NPS determination in plasma/serum, urine, and oral fluids have been widely discussed, such as liquid-liquid, solid-phase, and micro extraction approaches, highlighting the advantages and drawbacks of the proposed extraction methodologies. Regarding microextraction approaches, techniques like microextracti…
Dispersive micro-solid phase extraction
2019
Abstract Dispersive micro-solid phase extraction (D-μSPE) has gained special attention in the sample preparation process due to its simplicity, speed and efficiency. Different dispersion approaches have been used within this technique to allow a close contact between the sorbent and the donor sample solution during the entrapping step, but also between the sorbent and the solvent in the elution step. This dispersion favors the kinetics of both sorption and elution and therefore increases the efficiency of the overall extraction procedure. This technique boasts of high versatility owing to the great variety of solids available, covering a high range of chemical functionalities. This article …
Statistical analysis of latency outcomes in behavioral experiments
2011
In experimental designs of animal models, memory is often assessed by the time for a performance measure to occur (latency). Depending on the cognitive test, this may be the time it takes an animal to escape to a hidden platform (water maze), an escape tunnel (Barnes maze) or to enter a dark component (passive avoidance test). Latency outcomes are usually statistically analyzed using ANOVAs. Besides strong distributional assumptions, ANOVA cannot properly deal with animals not showing the performance measure within the trial time, potentially causing biased and misleading results. We propose an alternative approach for statistical analyses of latency outcomes. These analyses have less distr…
Liquid sample introduction in inductively coupled plasma atomic emission and mass spectrometry — Critical review
2014
Abstract Inductively coupled plasma optical emission spectroscopy (ICP-OES) and mass spectrometry (ICP-MS) can be considered as the most important tools in inorganic analytical chemistry. Huge progress has been made since the first analytical applications of the ICP. More stable RF generators, improved spectrometers and detection systems were designed along with the achievements gained from advanced microelectronics, leading to overall greatly improved analytical performance of such instruments. In contrast, for the vast majority of cases liquid sample introduction is still based on the pneumatic principle as described in the late 19th century. High flow pneumatic nebulizers typically deman…
Laser-Induced Breakdown Spectroscopy for Rapid Elemental Analysis of Drillcore
2013
Abstract The elemental and mineralogical contents of rock drillcore can be analyzed using a variety of methods. For efficient exploration the characterization of the drillcore should be performed rapidly, so that the further drillings can be better planned and unnecessary costs can be reduced. In this paper, laser-induced breakdown spectroscopy (LIBS) is studied as a potential rapid on-line method for automated elemental analysis of drillcore. The method is based on a pulsed laser beam that transforms a small volume of the sample into plasma. Individual elements in the plasma have characteristic emission patterns detectable by a spectrometer. Based on the measured spectra the amount of diff…
Determination of dithiocarbamates and metabolites in plants by liquid chromatography–mass spectrometry
2004
Abstract A quantitative matrix solid-phase dispersion and liquid chromatography–atmospheric pressure chemical ionization mass spectrometry (LC–APCI–MS) method is outlined for the simultaneous analysis of dithiocarbamates (DTCs) and their degradation products in plants. Compounds analyzed are dazomet, disulfiram, thiram and the metabolites ethylenthiourea and propylenthiourea. The performance of two different sample preparation protocols, the proposed one and other based on solid-phase extraction, as well as, of both atmospheric pressure ionization sources, APCI and electrospray, were compared. The effect of several parameters on the extraction, separation and detection was studied. Dithioca…