Search results for "electrospray"
showing 10 items of 318 documents
Analysis of carbamate and phenylurea pesticide residues in fruit juices by solid-phase microextraction and liquid chromatography–mass spectrometry
2007
A new analysis method to detect carbamates and phenylurea pesticide residues in fruit juices was developed using solid-phase microextraction (SPME) coupled with liquid chromatography-single quadrupole mass spectrometry (LC/MS) and liquid chromatography-quadrupole ion trap mass spectrometry (LC/QIT-MS). The pesticide residues present in watery matrices as fruit juices were extracted using three types of fibers: 50-microm Carbowax/templated resin (CW/TPR), 60-mum poly(dimethylsiloxane)/divinylbenzene (PDMS/DVB) and 85-microm polyacrylate. The different extraction conditions were evaluated choosing as the best parameters 90 min (time), 20 degrees C (temperature) and 1 ml (volume). After extrac…
Comparison of various liquid chromatographic methods for the analysis of avermectin residues in citrus fruits.
2001
Abstract Various liquid chromatographic (LC) techniques for analyzing avermectin (Abamectin) were compared after extraction of residues from citrus fruit samples by matrix solid-phase dispersion (MSPD). LC with UV and fluorescence detection were used as also was LC coupled to the mass spectrometer by an electrospray interface. The results obtained by the three methods were compared in terms of sensitivity and selectivity. The combination of MSPD extraction and LC with fluorescence detection have made it possible to quantify 0.5 μg kg −1 of Abamectin in 0.5 g of orange sample, with an overall average recovery of 94%. The procedure provides a simple and sensitive method for monitoring Abamect…
Study of the Fragmentation of D-Glucose and Alkylmonoglycosides in the Presence of Sodium Ions in an Ion-Trap Mass Spectrometer
2009
Abstract Using electrospray ion-trap mass spectrometry, the fragmentation of D-glucose and alkylmonoglycopyranosides (alkyl-GPs) was studied. In the presence of Na+, B1 and 0,2A fragmentations were observed. The alkyl-GPs also showed a 2,5Afragmentation. A cluster containing no carbon atoms and adducts of this cluster with neutral molecules were observed. Standards of alkylmonoglycofuranosides (alkyl-GFs) were not available; however, their fragmentation was studied by high-performace liquid chromatography–mass spectrometry (HPLC-MS) and HPLC-MS2 using an industrial mixture of alkylpolyglycosides. The cluster and its adducts were more easily formed by the alkyl-GPs than by the alkyl-GFs, but…
Fragmentations and reactions of some isotopically labelled dimethyl methyl phosphono and trimethyl phosphoro thiolates and thionates studied by elect…
2005
In this paper, studies on electrospray ionisation ion trap mass spectrometry of organophosphates are extended to a series of dimethyl methylphosphono and trimethyl phosphoro thionates and thiolates and some deuterated isotopomers. Of particular, interest is the comparison of the collision-induced fragmentation of ions from these compounds with those of the non-sulphur containing analogues reported previously. The thiono and thiolo isomeric structures of the sulphur containing ions analogous to I and II (see below) have very similar energies and undergo a ready interconversion. In the case of the phosphono compounds, the electronic structure calculations show that the methyl migration implic…
Sensitization of nanocrystalline TiO2 with 3,4,9,10-perylene tetracarboxylic acid
2014
Optical properties of 3,4,9,10-perylene tetracarboxylic acid (PTCA) in the presence of nanocrystalline TiO2 (nominal diameter 15 nm) have been investigated in ethanol solution and in the solid state by UV-Vis absorption spectroscopy and steady-state and time-resolved fluorescence. Experimental results show that, in ethanol, the presence of TiO2 nanoparticles causes significant changes in the typical absorption and fluorescence bands of PTCA and in the fluorescence relaxation time. Similar effects are also detected in solid samples, obtained by electrospray deposition technique. The nonlinear optical properties of the PTCA-TiO2 in ethanol solutions were investigated using the single-beam Z-s…
Simultaneous determination of different classes of antibiotics in fish and livestock by CE-MS
2007
A specific CE-MS method was developed for the simultaneous determination of 12 antibacterial residues (four sulfonamides: sulfamethazine, sulfathiazole, sulfadiazine, and sulfachlorpyridazine; four beta-lactams: amoxicillin, ampicillin, oxacillin, and penicillin V, and four quinolones: danofloxacin, enrofloxacin, ofloxacin, and flumequine) in fish and livestock. Separation conditions, sheath liquid composition and electrospray parameters were optimized to obtain adequate CE separation and a high sensitivity. CE employed a 75 cm long fused-silica capillary (50 cm thermostated plus 25 cm at room temperature) 75 microm id and a 60 mM ammonium acetate separation buffer at pH 8 with 10% of metha…
Nanoelectrospray with ion-trap mass spectrometry for the determination of beta-casomorphins in derived milk products.
2009
Beta-casomorphins (b-CMs) are bioactive peptides derived from casein with opioid agonist effects similar to morphine. The use of electrospray (ESI) with quadrupole ion-trap mass spectrometry (QIT-MS) for these compounds in two matrices, cheese and milk, was examined. It was compared to a liquid chromatography (LC) coupled to mass spectrometry (LC-MS), and a "soft" ionisation technique, NanoMate, with selected ion monitoring (SIM), which are unreliable for the determination of trace casomorphins in derived milk products. b-CM mass fragmentation pathways were done for the four most common b-CMs: beta-casomorphin (1-5) bovine (b-CM-5), beta-casomorphin (1-7) bovine (b-CM-7), [D-Ala2, D-Pro4,Ty…
Analysis of meat samples for anabolic steroids residues by liquid chromatography/tandem mass spectrometry.
2007
A rapid, specific and highly sensitive multi-residue method for the determination of anabolic steroid residues in bovine, pork and poultry muscle tissues was developed. The sample preparation involves enzymatic digestion followed by extraction with methanol. The crude extract was cleaned up by solid-phase extraction (SPE) combining C18 and NH2 columns. The detection was carried out by a highly sensitive liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method using both positive and negative ionization modes. Natural and synthetic steroids covering different polarities could be extracted, concentrated and purified using one single method. Mobile phase com…
Analysis of enniatins and beauvericin by LC-MS/MS in wheat-based products
2017
Due to the matrix complexity for wheat-based products, a comparative study of different rapid extraction procedures was performed for the extraction of enniatins (ENA, ENA1, ENB, ENB1) and beauvericin in flour, pasta, breakfast cereals, and biscuits. Three different approaches were studied during the extraction and purification steps (shaker, Ultra-Turrax, and QuEChERS) for each matrix. Liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) with electrospray source working in a positive mode was used. For the analysis of the five mycotoxins, the three methods were tested in terms of recovery, matrix effect, and sensibility, concluding that Ultra-Turrax extraction was the most …
Measurement of pollution levels of N-nitroso compounds of health concern in water using ultra-performance liquid chromatography–tandem mass spectrome…
2017
International audience; This paper reports the development of a highly sensitive analytical method combining solid-phase extraction (SPE) with ultra-high performance liquid chromatography coupled with tandem mass spectrometry (UHPLC–MS/MS), for the monitoring of ultra-trace levels of N-nitrosamines in water samples. Under optimized analytical conditions, chromatographic separation was performed in 3 min, in isocratic mode, using an Acquity UHPLC C18 column and a mobile phase consisting of acetonitrile, water, and formic acid (60:40:0.1, v/v/v) at a flow rate of 0.4 mL min−1. Electrospray ionization tandem interface was employed prior to mass spectrometric detection. Good linearity (R2 ≥ 0.9…