Search results for "high-performance liquid chromatography"
showing 10 items of 629 documents
Determination of catecholamines in urine by micellar liquid chromatography with coulometric detection
1994
The determination of catecholamines by HPLC with a sodium dodecyl-sulphate (SDS), micellar mobile phase on a C18 column and with coulometric detection was studied. The eluate was conditioned at +0.25 and +0.00 V, and the current at −0.16V was recorded. A previously developed model which describes the chromatographic behaviour of solutes in HPLC with hybrid, micellar mobile phases was used to optimize the SDS and ethanol concentrations. A mobile phase of 0.15M SDS in a phosphate buffer of pH 3.4 and without ethanol is recommended. The limits of detection were 0.4–0.7 ng ml−1. The procedure was applied to the determination of unconjugated L-dopa, norepinephrine and dopamine in urine. Direct i…
Sequential injection spectrophotometric determination of oxybenzone in lipsticks
2001
A sequential injection (SI) procedure for the spectrophotometric determination of oxybenzone in lipsticks is reported. The colorimetric reaction between nickel and oxybenzone was used. SI parameters such as sample solution volume, reagent solution volume, propulsion flow rate and reaction coil length were studied. The limit of detection was 3 microg ml(-1). The sensitivity was 0.0108+/-0.0002 ml microg(-1). The relative standard deviations of the results were between 6 and 12%. The real concentrations of samples and the values obtained by HPLC were comparable. Microwave sample pre-treatment allowed the extraction of oxybenzone with ethanol, thus avoiding the use of toxic organic solvents. E…
Simultaneous detection of three antiviral and four antibiotic compounds in source-separated urine with liquid chromatography
2013
An analytical method for the simultaneous screening of three antiviral agents (nevirapine, zidovudine, lamivudine), four antibiotics (sulfamethoxazole, trimethoprim, ciprofloxacin, rifampicin) and one reference compound (carbamazepine) in human urine was developed. Separation was achieved with a Kinetex XB-C18 (75 × 4.6 mm, 2.6 μm) column after the extraction of pharmaceuticals from urine with SPE. Gradient elution with a mobile phase consisting of acetonitrile and 10 mM KH2 PO4 (pH 2.5), and diode array detection with monitoring at 210 and 264 nm was applied. The developed method was validated in terms of selectivity, linearity, stability and sensitivity. Repeatability (n = 3) and between-…
High performance liquid chromatography—atomic fluorescence spectrometric determination of arsenic species in beer samples
2003
Abstract A method has been developed for the direct determination of As(III), dimethylarsinic acid (DMA), monomethylarsonic acid (MMA) and As(V) in beers by hydride generation—atomic fluorescence spectrometry after separation of arsenic species by high performance liquid chromatography. Compounds were separated by anion-exchange chromatography with isocratic elution using KH 2 PO 4 /K 2 HPO 4 as mobile phase with elution times of 1.67, 2.08, 6.52 and 10.72 min for As(III), DMA, MMA and As(V), respectively. Parameters affecting the hydride generation of all arsenic species were studied and the best conditions were established as a reaction coil of 150 cm, for a sample injected volume of 100 …
Simultaneous determination of olanzapine, clozapine and demethylated metabolites in serum by on-line column-switching high-performance liquid chromat…
2001
An automated method for simultaneous routine quantification of the antipsychotic drugs clozapine, olanzapine and their demethylated metabolites is described. The method included adsorption on a cyanopropyl (CPS) coated clean-up column (10 microm; 10 x 2.0 mm I.D.), washing off interfering serum constituents to waste, and separation on C18 ODS Hypersil reversed phase material (5 microm; 250 x 4.6 mm I.D.) using acetonitrile-water-tetramethylethylenediamine (37:62.6:0.4, v/v/v) adjusted to pH 6.5 with concentrated acetic acid. UV-detection was performed at 254 nm. The limit of quantification was 10-20 ng/ml. Relative day to day standard variations ranged between 4.5 and 13.5%. The method is s…
Determination of synthetic antioxidants in dairy products and dietetic supplements by micellar liquid chromatography with direct sample injection
2000
A simple and rapid HPLC method for the determination of synthetic antioxidants (propyl gallate, tert-butylhydroquinone, 2,4,5-trihydroxybutyrophenone, nordihydroguaiaretic acid, octyl gallate, 3-tert-butyl-4-hydroxyanisole and dodecyl gallate) in powdered and liquid milk, cream of milk and dietetic supplements is described. The samples are diluted or solved in a micellar solution, filtered and directly injected. The retention behavior of the antioxidants on a C18 column, with micellar mobile phases containing SDS (0.05–0.15 M), n-propanol (1–9%, v/v) and 10 mM phosphate at pH 3, has been studied by using mathematical models. Retention is predicted with errors below 3%. To optimize the mobil…
Sensitive determination of probenecid in urine samples by reversed-phase liquid chromatography and UV-visible detection using solid-phase extraction …
1993
This study describes a rapid method for the determination of probenecid in human urine by liquid chromatography with UV detection at 254 nm, after clean-up through a C8 solid-phase extraction column. Liquid chromatography was carried out on a C18-bonded phase using an acetonitrile-acetate buffer (pH=4) gradient elution. Ethacrynic acid was used as internal standard. The system has been applied to the determination of probenecid in the 0.10–100.0 μg/ml concentration range; the limit of detection was 5 ng/mL.
Supercritical fluid extraction and high performance liquid chromatography determination of homosalate in lipsticks
2001
Supercritical fluid extraction of homosalate is reported for the first time. Extraction parameters such as pressure, time of extraction, use of modifier, temperature and sample mass were studied. The proposed method was assayed for the extraction of homosalate in sunscreen lipsticks. Efficient recoveries were obtained after 5 min of dynamic extraction with supercritical CO2 and 15% ethanol as modifier at 300 bar and 60°C, flow rate 4 mL min−1. Extracts were dissolved in ethanol, and homosalate determined by HPLC using water—acetic acid—ethanol mobile phase and flow rate of 1 mL min−1. UV detection was at 309 nm using homosalate in ethanol solutions as standards, limit of detection 4 μg mL−1…
Analysis of organic pollutants in water at trace levels using fully automated solid-phase extraction coupled to high-performance liquid chromatography
1997
A method has been developed for the determination of trace levels of 32 pesticides, 19 explosives and 16 polycyclic aromatic hydrocarbons (PAH) in water in three individual steps. Solid-phase enrichment (SPE) is coupled to high-performance liquid chromatography (HPLC) with a fully automated system. The organic pollutants are enriched on reusable cartridges packed with adsorbent materials: pesticides and explosives on a mixed bed of divinylbenzene-ethylvinylbenzene copolymers (LiChrolut EN®) and perfluorinated polyethylene (PolyF®), and polycyclic aromatic hydrocarbons on C18-modified silica (Zorbax® ODS1). Thermally assisted desorption (TAD) has been shown to increase the recovery of analyt…
High-performance liquid chromatographic determination of sumatriptan after in vitro transdermal diffusion studies.
2004
A simple, accurate, precise and rapid HPLC method with UV detection has been validated in order to determine the in vitro transdermal absorption of sumatriptan succinate. The HPLC method is a modification of that described by Nozal et al. [M.J. Nozal, J.L. Bernal, L. Toribio, M.T. Martin, F.J. Diez, J. Pharm. Biomed. Anal. 30 (2002) 285-291]. Separation was carried out on a 250 mm Kromasil C18 column at room temperature. The detector response, at 282.7 nm, was found to be linear in a concentration range between 0.145 and 145 microM. The limit of detection (LOD) was 0.019 microM and the limit of quantification (LOQ) was 0.145 microM.