Search results for "libration"
showing 10 items of 901 documents
Isotope dilution mass spectrometry as a calibration method for the analysis of trace elements in powder samples by LA-ICP-MS
2003
The applicability of the isotope dilution (ID) technique for trace element determinations in powdered solid samples by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is demonstrated. LA-ICP-IDMS combines the advantage of the isotope dilution technique as a definitive method with the powerful capability of LA-ICP-MS for a fast and direct multi-element analysis of solid samples. LA-ICP-IDMS therefore allows matrix-matched quantification of element concentrations without any external standard, which is not possible by other calibration strategies used in LA-ICP-MS, up to now. The sample preparation effort is kept minimal and consists of an addition of the corresponding…
Spectrophotometric determination of promazine with an oxidative column in FIA manifolds
1992
Abstract A simple flow-injection spectrophotometric method for the determination of promazine is described. The two proposed procedures are based on the oxidation of analyte with a manganese dioxide column. Concentrations of promazine in the ranges 2–20 and 1–6 are determined with a relative standard deviation of 1.0%. The injection rates are 62 and 80 samples h −1 , respectively. The influence of foreign species and the determination of promazine in a pharmaceutical formulation are also reported.
Evaluation and elimination of the “blank bias error” using the H-point standard addition method
1992
Abstract The basis of the H-point standard addition method in the cases where the analyte determination requires the use of an absorbent reagent is considered. The method evaluates and eliminates the blank bias error present in such procedures by using the absorbance increment at two selected wavelengths as the analytical signal of the calibration graphs. Three different determinations were tested: the determination of proteins with the biuret method, thorium with thoron and of magnesium with Titan Yellow. These procedures are better described by the proposed method than by the traditional approach using absorbance values against reagent blank.
Determination of Bisulfites in Wines with an Electronic Tongue Based on Pulse Voltammetry
2009
Electronic tongues were developed some ten years ago. These systems consist of an array of nonspecific sensors and a signal processing unit. The sensor signals are processed by pattern recognition methods which makes possible the extraction of specific properties from the sample. Depending on the calibration, attributes such as quality or taste can be determined. These systems also detect changes in the sample that they are not calibrated for which makes possible the detection of anomalous occurrences. Such sensor systems are suitable for process control and surveillance. Important factors are the sensitivity and stability, specifically the sensor's ability to respond to small changes and t…
Evaluation and elimination of the blank bias error using the H-point standard additions method (HPSAM) in the simultaneous spectrophotometric determi…
1997
Abstract The aim of this report is to demonstrate the usefulness of the HPSAM in all instances where the determination of two analytes requires the use of an absorbent reagent, particularly when it does not present a constant analytical signal because of its consumption. This problem can be treated as a ternary mixture by the HPSAM method and then, the fundamentals of the method for resolving these kind of mixtures can be applied. The method can calculate the concentration of one species from spectral data at two wavelengths where the two other species present the same absorbance relationship. These wavelength pairs are easily found, and can be selected to give the most precise results. The…
Identification and determination of synthetic cannabinoids in herbal products by dry film attenuated total reflectance-infrared spectroscopy.
2017
A new procedure has been developed for the identification and quantitative determination of synthetic cannabinoids in illicit herbal preparations. The methodology is based on the use of attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR) measurement of sample extracts with 2-propanol drying 5µL of the extracts onto the ATR crystal. The qualitative identification was carried out on the 2-propanol extract after identification of the herbal matrix, followed by its subtraction and using a cut-off criterion of 75%. Quantitative determination was made by univariate calibration using the absorbance of the band located at 1520cm-1 of the spectrum. Four different cannabin…
Validation of a confirmatory method for the determination of macrolides in liver and kidney animal tissues in accordance with the European Union regu…
2006
Abstract This study proposes a simple multiresidue liquid chromatography–diode array detector (LC–DAD) method capable of determining seven macrolide antibiotics in samples of liver and kidney animals at concentrations lower than those allowed by current legislation. Samples were prepared by homogenizing the tissue with EDTA–McIlvaine's buffer and extracted with an Oasis HLB cartridge. The consumption of organic solvent during extraction was minimum. The analytes were detected by LC–DAD and also by liquid chromatography–mass spectrometry with electrospray ionization (LC–(ESI)MS). The method was specific, stable and robust enough for the required purposes. The DAD method was validated in acco…
Evaluation of analytical performance of gas chromatography coupled with atmospheric pressure chemical ionization Fourier transform ion cyclotron reso…
2019
Abstract A new analytical method was established and validated for the analysis of eighteen halogenated flame retardants (HFRs)in food products. Gas chromatography (GC) coupled to Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) employing atmospheric pressure chemical ionization (APCI) was used for the identification and quantitation of contaminants. Intra-laboratory validation of the method was performed with respect to recovery, repeatability, linear calibration ranges, instrumental and method limits of quantitation (i-LOQ and m-LOQ), and trueness was verified where possible by analysis of reference materials (RMs). The validation results indicated recoveries of ana…
Quantitative colorimetric analysis of some inorganic salts using digital photography
2011
An analytical imaging approach to the quantitation of dissolved chemical species absorbed in the visible spectral region is reported. The approach uses digital images of a series of standard solutions of the target substance and their processing with appropriate software to assign a numeric value to each standard in terms of color intensity. Such a value is directly proportional to the analyte concentration and allows the construction of a calibration graph. The results thus obtained are compared with those provided by the classical spectrophotometricmethod used to run calibration curves for colored substances. The chemical imaging technique is relative simple and affordable; in fact, it ca…
Development of the H-point standard additions method for analyte determinations in unknown matrix
1993
Abstract The development of the H-point standard additions method is proposed in order to obtain the unbiased analyte concentration when the matrix of the sample is completely unknown. A spectral region where the interferent behaviour can be considered linear at three wavelengths must be chosen. The method uses the analytical signal data at these three wavelengths, usually situated in the maxima region of the analyte. Two procedures are proposed in order to know and to locate this behaviour for the unknown interferent. Several binary and ternary mixtures of phenol, 4-chlorophenol and 4-chloro-3-methylphenol as representative examples have been assayed, with accurate (less than 3% relative e…