Search results for "mines"

showing 10 items of 2609 documents

Molecular connectivity as a relevant new tool for predicting analytical behavior: A survey of chemiluminescence and chromatography

2005

Abstract We present a critical presentation and discussion on molecular connectivity applied to analytical fields, giving special attention to predicting the chemiluminescent behavior of pharmaceuticals and pesticides. Molecular connectivity has been largely applied to predict the therapeutic effects of pharmaceuticals and rarely to predictions in analytical chemistry – basically to chromatographic processes and recently to liquid-phase chemiluminescence.

ChromatographyChemistrylawLiquid phaseMolecular topologySpectroscopyTopology (chemistry)Analytical ChemistryChemiluminescencelaw.inventionTrAC Trends in Analytical Chemistry
researchProduct

Chromatographic analysis of phenethylamine-antihistamine combinations using C8, C18 or cyano columns and micellar sodium dodecyl sulfate-pentanol mix…

2001

The chromatographic behaviour of binary and ternary mixtures of several phenethylamines (phenylephrine, phenylpropanolamine, ephedrine, pseudoephedrine and methoxyphenamine) and antihistamines (pheniramine, carbinoxamine, doxylamine, chlorpheniramine, dexchlorpheniramine, dexbrompheniramine, diphenhydramine, tripolidine, azatadine and phenyltoloxamine), found in cough-cold pharmaceutical preparations, was studied using C8, C18 and cyano columns, micellar mobile phases of sodium dodecyl sulfate (SDS) and pentanol and UV detection. Using a C8 column and mobile phases of 0.05 mol l-1 SDS-6% v/v pentanol or 0.15 mol l-1 SDS-2% v/v pentanol at pH 7, more than 30 different phenethylamine-antihist…

ChromatographyChromatographyMethoxyphenaminePhenethylaminesPseudoephedrineAscorbic acidBiochemistrySensitivity and SpecificityAnalytical Chemistrychemistry.chemical_compoundNasal DecongestantschemistryPhenyltoloxaminePhenethylaminesElectrochemistrymedicineHistamine H1 AntagonistsEnvironmental ChemistryCarbinoxaminePheniramineSodium dodecyl sulfateSpectroscopymedicine.drugThe Analyst
researchProduct

Flow Methods in Pharmaceutical Analysis

2008

ChromatographyMembrane diffusionFlow (mathematics)medicine.diagnostic_testChemistrySpectrophotometryDrug releasemedicineLuminescenceElectrochemistry
researchProduct

Inhibition of the system luminol-H2O2-Fe(CN)63− chemiluminescence by the Mn(II) indirect determination of isoniazid in a pharmaceutical formulation

1998

A flow injection procedure for the indirect chemiluminescent determination of isoniazid is proposed. The method is performed in a flow-injection manifold provided with a solid-phase reactor. The reactor was made from manganese dioxide physically entrapped by polymerization; the redox reaction isoniazid-manganese dioxide released Mn(II) which was monitored through its inhibitory effect on the reaction between luminol and hydrogen peroxide in presence of potassium hexacyanoferrate (III). The procedure resulted in a linear calibration graph over the range 5-15 mg/L of isoniazid with a sample throughput of 43 samples/h. The influence of foreign compounds was studied and the method was applied t…

ChromatographyPotassiumBiophysicschemistry.chemical_elementManganesePharmaceutical formulationRedoxlaw.inventionLuminolchemistry.chemical_compoundchemistryPolymerizationChemistry (miscellaneous)lawHydrogen peroxideChemiluminescenceNuclear chemistryJournal of Bioluminescence and Chemiluminescence
researchProduct

Target analysis of primary aromatic amines combined with a comprehensive screening of migrating substances in kitchen utensils by liquid chromatograp…

2015

An analytical strategy including both the quantitative target analysis of 8 regulated primary aromatic amines (PAAs), as well as a comprehensive post-run target screening of 77 migrating substances, was developed for nylon utensils, using liquid chromatography-orbitrap-high resolution mass spectrometry (LC-HRMS) operating in full scan mode. The accurate mass data were acquired with a resolving power of 50,000 FWHM (scan speed, 2 Hz), and by alternating two acquisition events, ESI+ with and without fragmentation. The target method was validated after statistical optimization of the main ionization and fragmentation parameters. The quantitative method presented appropriate performance to be u…

ChromatographyPrimary (chemistry)Food contactChemistryRelative standard deviationAnalytical chemistryTarget analysisFood ContaminationOrbitrapCooking and Eating UtensilsAnalytical Chemistrylaw.inventionMassNylonsKitchen utensilslawTandem Mass SpectrometryAnalytical strategyHumansAminesOrganic ChemicalsChromatography LiquidTalanta
researchProduct

Effects of ultrahigh dilutions of 3,5-dichlorophenol on the luminescence of the bacterium Vibrio fischeri.

2003

Abstract There is a great need for research in the field of homeopathy for laboratory test systems to investigate the actions of ultrahighly diluted biological effectors. With this in mind, we used the luminescent bacterium Vibrio fischeri, which is used throughout the world in testing water quality. Luminescence inhibition is utilized as a test parameter for the toxicity of a sample. We used ultrahigh dilutions (UHD) of 3,5-dichlorophenol as effector and adapted the standard test procedure for water toxicity in a way that let us evaluate very minute effects. Three groups of samples were prepared and then blinded: 45 dilutions of 3,5-dichlorophenol in steps of 10, starting with 4.2×10−2 M, …

ChromatographySerial dilutionBiophysicsHomeopathyMicrobial Sensitivity TestsBiologybiology.organism_classificationBiochemistryDiluentVibrioMicrobiologyDilutionchemistry.chemical_compoundchemistryData Interpretation StatisticalToxicityLuminescent MeasurementsPotencyLuminescenceDichlorophenolMolecular BiologyChlorophenolsVibrioBiochimica et biophysica acta
researchProduct

Measurement of the Md3+/Md2+ Reduction Potential Studied with Flow Electrolytic Chromatography

2013

The reduction behavior of mendelevium (Md) was studied using a flow electrolytic chromatography apparatus. By application of the appropriate potentials on the chromatography column, the more stable Md(3+) is reduced to Md(2+). The reduction potential of the Md(3+) + e(-) → Md(2+) couple was determined to be -0.16 ± 0.05 V versus a normal hydrogen electrode.

ChromatographyStandard hydrogen electrodeFlow (psychology)Analytical chemistrychemistry.chemical_elementElectrolyteIonMendeleviumInorganic ChemistryReduction (complexity)chemistryPhysical and Theoretical ChemistryLuminescenceChromatography columnInorganic Chemistry
researchProduct

FIA-Chemiluminescence Determination of Acridine Yellow

2003

Abstract The direct determination of yellow acridine is performed by a FIA assembly on the basis of the oxidation of the acridine. The acridine solution is injected into a pure water stream. This solution merges with the oxidant solution (KMnO4 in sulfuric acid medium) and the resulting chemiluminescence allows the method to be applied over the range 0.01–100 mg L−1 of acridine with a correlation coefficient of 0.9997. The relative standard deviation (%) is 1.6 and the sample throughput 60 h−1. The influence of foreign substances is also tested. The new method is applied to the determination of yellow acridine in waste waters.

ChromatographyStereochemistryBiochemistry (medical)Clinical BiochemistryRelative standard deviationSulfuric acidWater streamBiochemistryAnalytical Chemistrylaw.inventionchemistry.chemical_compoundPotassium permanganatechemistryAcridine yellowlawAcridineElectrochemistryQuantitative analysis (chemistry)SpectroscopyChemiluminescenceAnalytical Letters
researchProduct

Rapid and simultaneous high-performance liquid chromatography assay of polyamines and monoacetylpolyamines in biological specimens

2000

A rapid, resolutive and reproducible reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed for polyamines and acetylpolyamines by adopting pre-column derivatization with benzoyl chloride. In a single run lasting less than 15 min ten polyamines were separated as well as traces of benzoic acid, methylbenzoate and benzoic anhydride. These contaminants, produced during the derivatization reaction, were almost all eliminated by washing steps envisaged in the same procedure. This simple and sensitive method can be applied to routine determination of polyamines in biological samples. A fine application of this procedure to the determination of endogenous content of p…

Chromatographymedicine.diagnostic_testorganic chemicalsBiogenic PolyaminesReproducibility of ResultsGeneral ChemistryReversed-phase chromatographyReference StandardsSensitivity and SpecificityHigh-performance liquid chromatographyBenzoic anhydridechemistry.chemical_compoundBenzoyl chloridechemistrySpectrophotometrymedicineSpectrophotometry UltravioletDerivatizationQuantitative analysis (chemistry)Chromatography High Pressure LiquidBenzoic acidJournal of Chromatography B: Biomedical Sciences and Applications
researchProduct

Cover Feature: A Strongly Luminescent Chromium(III) Complex Acid (Chem. Eur. J. 48/2018)

2018

ChromiumChemistryFeature (computer vision)Organic ChemistryInorganic chemistrychemistry.chemical_elementCover (algebra)General ChemistryLuminescenceCatalysisChemistry - A European Journal
researchProduct