Search results for "mobili"
showing 10 items of 1705 documents
Multi-model ensemble simulations of olive pollen distribution in Europe in 2014: current status and outlook
2017
"Çalışmada 29 yazar bulunmaktadır. Bu yazarlardan sadece Bursa Uludağ Üniversitesi mensuplarının girişleri yapılmıştır” The paper presents the first modelling experiment of the European-scale olive pollen dispersion, analyses the quality of the predictions, and outlines the research needs. A 6-model strong ensemble of Copernicus Atmospheric Monitoring Service (CAMS) was run throughout the olive season of 2014, computing the olive pollen distribution. The simulations have been compared with observations in eight countries, which are members of the European Aeroallergen Network (EAN). Analysis was performed for individual models, the ensemble mean and median, and for a dynamically optimised c…
Finite-size scaling of charge carrier mobility in disordered organic semiconductors
2016
Simulations of charge transport in amorphous semiconductors are often performed in microscopically sized systems. As a result, charge carrier mobilities become system-size dependent. We propose a simple method for extrapolating a macroscopic, nondispersive mobility from the system-size dependence of a microscopic one. The method is validated against a temperature-based extrapolation [A. Lukyanov and D. Andrienko, Phys. Rev. B 82, 193202 (2010)]. In addition, we provide an analytic estimate of system sizes required to perform nondispersive charge transport simulations in systems with finite charge carrier density, derived from a truncated Gaussian distribution. This estimate is not limited t…
Tuning the selectivity of molecularly imprinted polymer extraction of arylcyclohexylamines: From class-selective to specific
2020
Abstract A molecularly imprinted polymer (MIP) has been prepared in presence of 3-hydroxy phencyclidine (3-OH PCP) as template by bulk polymerization using N,N-dimethylformamide, as porogenic solvent, for the selective solid-phase extraction (SPE) of arylcyclohexylamines from oral fluids. Experimental variables of the extraction procedure have been studied in order to increase both, extraction recovery of 3-OH PCP, used as model analyte, and imprinting factor. By modifying the composition of the washing solvent, the selectivity of the MIP extraction procedure can be tuned, moving from an arylcyclohexylamine selective method to a 3-OH PCP specific method. The applicability of the synthesized…
Amphetamine-type stimulants analysis in oral fluid based on molecularly imprinting extraction
2018
Abstract A methamphetamine-based molecularly imprinted polymer (MIP) has been prepared by bulk polymerization to recognize new psychoactive substances (NPS) of the amphetamine, cathinones and 2C families in oral fluid samples, being the first precedent of a synthetized MIP for the extraction and preconcentration 32 NPS including amphetamine type substances and synthetic cathinones from oral fluids. Pre-polymerization complex and resulting materials were appropriately characterized by infrared spectroscopy, scanning electron microscopy, and nitrogen adsorption-desorption isotherms. Appropriateness of the material for the specific recognition of the target analytes was also evaluated through …
Affinity Sensors for the Diagnosis of COVID-19
2021
The coronavirus disease 2019 (COVID-19) outbreak caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was proclaimed a global pandemic in March 2020. Reducing the dissemination rate, in particular by tracking the infected people and their contacts, is the main instrument against infection spreading. Therefore, the creation and implementation of fast, reliable and responsive methods suitable for the diagnosis of COVID-19 are required. These needs can be fulfilled using affinity sensors, which differ in applied detection methods and markers that are generating analytical signals. Recently, nucleic acid hybridization, antigen-antibody interaction, and change of reactive oxyge…
Towards an automatic lab-on-valve-ion mobility spectrometric system for detection of cocaine abuse.
2017
A lab-on-valve miniaturized system integrating on-line disposable micro-solid phase extraction has been interfaced with ion mobility spectrometry for the accurate and sensitive determination of cocaine and ecgonine methyl ester in oral fluids. The method is based on the automatic loading of 500μL of oral fluid along with the retention of target analytes and matrix clean-up by mixed-mode cationic/reversed-phase solid phase beads, followed by elution with 100μL of 2-propanol containing (3% v/v) ammonia, which are online injected into the IMS. The sorptive particles are automatically discarded after every individual assay inasmuch as the sorptive capacity of the sorbent material is proven to b…
Off-line coupling of multidimensional immunoaffinity chromatography and ion mobility spectrometry: A promising partnership.
2015
The extreme specificity of immunoaffinity chromatography (IAC) columns coupled to the high sensitivity of ion mobility spectrometry (IMS) measurements makes this combination really useful for rapid, selective, and sensitive determination of a high variety of analytes in different samples. The capabilities of the IAC-IMS coupling have been highlighted under three different scenarios: (i) multiclass residue analysis using a single IAC column, (ii) multiclass residue analysis using stacked IAC columns, and (iii) isomer analysis. In the first case, the determination of three strobilurin fungicides - azoxystrobin, picoxystrobin, and pyraclostrobin - in water and strawberry juice was considered, …
Tips on ligand immobilization and kinetic study using surface plasmon resonance.
2016
Surface plasmon resonance (SPR) technique offers a robust label-free approach applicable in various investigations including binding affinity, specificity and kinetics of biological macromolecules (e.g., peptides, proteins and nucleotidase) and small molecules. SPR provides extremely important data on the kinetics and affinity of substances examined, through which bio-specific interaction(s) can be established by the analysis of adsorption of analyte onto the immobilized ligand(s) on a sensor-based analytical system. Due to SPR wide applications in biomedical laboratories, the aim of this editorial is to highlight the importance of SPR in affinity kinetics and ligand immobilization.
Simultaneous endo and exo Complex Formation of Pyridine[4]arene Dimers with Neutral and Anionic Guests
2017
The formation of complexes between hexafluorophosphate (PF6- ) and tetraisobutyloctahydroxypyridine[4]arene has been thoroughly studied in the gas phase (ESI-QTOF-MS, IM-MS, DFT calculations), in the solid state (X-ray crystallography), and in chloroform solution (1 H, 19 F, and DOSY NMR spectroscopy). In all states of matter, simultaneous endo complexation of solvent molecules and exo complexation of a PF6- anion within a pyridine[4]arene dimer was observed. While similar ternary complexes are often observed in the solid state, this is a unique example of such behavior in the gas phase.
Ion mobility mass spectrometry – an efficient tool for the analysis of conformational switch of macrocyclic receptors upon anion binding
2021
Interactions between anions and synthetic macrocyclic receptors belong to the extensively explored area of research due to the particularly important functions of anions in biological and environmental sciences. Structures of anion-macrocycle complexes are closely related to their function, highlighting the importance of structural analysis of the complexes. Here, we discuss the application of ion mobility mass spectrometry (IM-MS) and theoretical calculations to the structural analysis of tetralactam macrocycles (M) with varying flexibility and structural properties, and their complexes with anions [M + X]−. Collision cross section (CCS) values obtained from both direct drift tube (DT) and…