Acute performance evaluation of a new ventricular automatic capture algorithm
2006
Aims This study evaluated the acute clinical performance of a new ventricular automatic capture algorithm developed to work with all lead types and pacing vectors. Methods and results During regular pacemaker implant or replacement, AutoThreshold and manual threshold tests were performed in ventricular unipolar (UP) and bipolar (BP, if applicable) pacing using a customized external prototype INSIGNIA™ pacemaker. The success rate and accuracy of two different modes (commanded and ambulatory) of the automatic capture algorithm were used to evaluate the performance. Loss-of-capture events (two consecutive non-captured beats without backup pacing) were used to assess safety. Data of 53 patients…
Low-energy epicardial pacing in children: the benefit of autocapture.
1999
Abstract Background . Permanent cardiac pacing in children results commonly in augmented energy consumption because of the high pacing rates and the ample stimulation safety margin applied in children. Cardiovascular anatomy and limited venous access sometimes preclude the otherwise preferred endocardial approach. In this multicenter patient series, we studied the feasibility, safety, and energy saving obtained by a combination of steroid-eluting epicardial leads with autocapture devices capable of ongoing adjustment of the stimulation output to the prevailing threshold. Methods . Autocapture devices (Pacesetter Microny SR+ and Regency SR+; Pacesetter, Solna, Sweden) and steroid-eluting epi…
Role of cardiac dyssynchrony and resynchronization therapy in functional mitral regurgitation
2016
Functional mitral regurgitation (FMR) is a common complication of left ventricle (LV) dysfunction and remodelling. Recently, it has been recognized as an independent prognostic factor in both ischaemic and non-ischaemic LV dysfunctions. In this review article, we discuss the mechanisms through which cardiac dyssynchrony is involved in FMR pathophysiologic cascade and how cardiac resynchronization therapy (CRT) can have therapeutic effects on FMR by reverting specific dyssynchrony pathways. We analyse recent clinical trials focusing on CRT impact on FMR in 'real-world' patients, the limits and future perspectives that could eventually generate new predictors of CRT response in terms of FMR r…
Paroxysmal atrial fibrillation and high degree AV block: use of single-lead VDDR pacing with mode switching.
1998
Dual chamber rate responsive pacing incorporating a mode switching option is increasingly used in patients with chronic paroxysmal atrial fibrillation and high degree AV block. Single-lead VDDR pacemakers have rarely used for this indication. The purpose of this study was to determine their reliability of atrial sensing during atrial fibrillation, the percentage of atrial synchronous ventricular pacing, and the behavior of the sinus rate outside the phases of atrial fibrillation. We studied ten patients with a single-lead VDDR pacemaker implanted for this indication. Follow-up visits were performed at predischarge and after 1, 3, 6, 12, 18, and 24 months. During the mean follow-up period of…
A simple method for preoperative assessment of the best fitting electrode length in single lead VDD pacing.
1996
For single lead VDD pacing, electrodes with various distances between the lead tip and the floating atrial dipole (AV distance) are available. Using different AV distances allows positioning of the atrial dipole in the mid- to high right atrium, regardless of the size of the right heart. In this position, reliable atrial sensing and rejection of ventricular far-field potentials can be expected. A simple test for the preoperative assessment of the best fitting AV distance in the individual patient was tested. We studied 24 consecutive patients prior to implantation of a VDD pacemaker. With the patient in supine position, a test electrode with an AV distance of 13 cm was taped onto the thorax…
Cardiovascular outcomes after cardiac resynchronization therapy in cardiac amyloidosis
2021
Abstract Aims Cardiac resynchronization therapy (CRT) is highly effective in dilated cardiomyopathy (DCM) patients with impaired left ventricular ejection fraction (LVEF) and left bundle block branch. In cardiac amyloidosis (CA) patients, left ventricular dysfunction and conduction defects are common, but the potential of CRT to improve cardiac remodelling and survival in this particular setting remains undefined. We investigated cardiovascular outcomes in CA patients after CRT implantation in terms of CRT echocardiographic response and major cardiovascular events (MACEs). Methods and results Our retrospective study included 47 CA patients implanted with CRT devices from January 2012 to Feb…
Is atrial sensing of ventricular far-field signals important in single-lead VDD pacing?
1998
UNLABELLED In single-lead VDD pacing the atrial sensitivity frequently is programmed to sensitive values. Atrial sensing of ventricular far-field signals should be reduced by differential atrial sensing. The aim of the study was to evaluate the effectiveness of this approach. METHODS The study included 10 patients with a single-lead VDD pacemaker (Thera 8948, Lead 5032). The atrial sensitivity was set to its most sensitive value of 0.18 mV and the telemetered intraatrial EGM was continuously recorded. After atrial tracked ventricular pacing, VVI pacing was performed with pacing rates from 100 to 160 beats/min in steps of 10 beats/min and up to 165 beats/min. The peak-to-peak amplitudes of P…
Exposed Subcutaneous Implantable Devices
2015
Background: Implantable venous and electrical devices are prone to exposure and infection. Indications for management are controversial, but—especially if infected—exposed devices are often removed and an additional operation is needed to replace the device, causing a delay in chemotherapy and prolonging healing time. We present our protocol for device salvage, on which limited literature is available. Methods: Between 2007 and 2013, 17 patients were treated (12 venous access ports, 3 cardiac pacemakers, and 2 subcutaneous neural stimulators). Most patients were operated within 7 days from exposure. All patients received only a single perioperative dose of prophylactic antibiotic. In cases …
Metal displacement deposition: a new route for template fabrication of metal and metal oxide nanostructures
2011
The COGNITION Study Rationale and Design: Influence of Closed Loop Stimulation on Cognitive Performance in Pacemaker Patients
2008
Background: Several studies showed the beneficial effect of pacemaker implantation on cognitive performance in patients with bradycardia. But it has never been investigated if patients with chronotropic incompetence may improve their cognitive performance if treated by a rate-adaptive system reacting to mental stress in comparison to the most frequently used accelerometer-driven pacing. Methods: The randomized, single-blind, multicenter COGNITION study evaluates if closed loop stimulation (CLS) offers incremental benefit in the speed of cognitive performance and the overall well-being of elderly patients with bradycardia compared with accelerometer-based pacing. Four hundred chronotropicall…