Search results for "pinhole"
showing 10 items of 23 documents
Application of Pinhole Plasma Jet Activated Water against Escherichia coli, Colletotrichum gloeosporioides, and Decontamination of Pesticide Residues…
2022
Plasma activated water (PAW) generated from pinhole plasma jet using gas mixtures of argon (Ar) and 2% oxygen (O2) was evaluated for pesticide degradation and microorganism decontamination (i.e., Escherichia coli and Colletotrichum gloeosporioides) in chili (Capsicum annuum L.). A flow rate of 10 L/min produced the highest concentration of hydrogen peroxide (H2O2) at 369 mg/L. Results showed that PAW treatment for 30 min and 60 min effectively degrades carbendazim and chlorpyrifos by about 57% and 54% in solution, respectively. In chili, carbendazim and chlorpyrifos were also decreased, to a major extent, by 80% and 65% after PAW treatment for 30 min and 60 min, respectively. E. coli popula…
Full-parallax 3D display from stereo-hybrid 3D camera system
2018
Abstract In this paper, we propose an innovative approach for the production of the microimages ready to display onto an integral-imaging monitor. Our main contribution is using a stereo-hybrid 3D camera system, which is used for picking up a 3D data pair and composing a denser point cloud. However, there is an intrinsic difficulty in the fact that hybrid sensors have dissimilarities and therefore should be equalized. Handled data facilitate to generating an integral image after projecting computationally the information through a virtual pinhole array. We illustrate this procedure with some imaging experiments that provide microimages with enhanced quality. After projection of such microim…
Optical sectioning by two-pinhole confocal fluorescence microscopy.
2003
A two-pinhole axially superresolving confocal fluorescence imaging system is presented. Based on the concept of subtractive incoherent imaging, the system described here is equipped with a zero-focus complex-transmittance pupil filter in one of the collector paths. The optical sectioning capacity of the system is 25% superior to that of a free-pupil one-pinhole instrument.
Pinhole Zone Plate Lens for Ultrasound Focusing
2017
[EN] The focusing capabilities of a pinhole zone plate lens are presented and compared with those of a conventional Fresnel zone plate lens. The focusing properties are examined both experimentally and numerically. The results confirm that a pinhole zone plate lens can be an alternative to a Fresnel lens. A smooth filtering effect is created in pinhole zone plate lenses, giving rise to a reduction of the side lobes around the principal focus associated with the conventional Fresnel zone plate lens. The manufacturing technique of the pinhole zone plate lens allows the designing and constructing of lenses for different focal lengths quickly and economically and without the need to drill new p…
Modélisation d'images agronomiques - application a la reconnaissance d'adventices par imagerie pour une pulvérisation localisée
2009
Plant (crop and weed) identification is a very active field of research in agriculture since the reinforcement of European laws about pesticide applications for a site-specific management of spraying practices. A new crop/weed simulation model was developed to allow the evaluation of crop/weed spatial identification methods from imaging. Considering multiples agronomic parameters – crop location, weed infestation rate, weed spatial distribution – the first step of this model allows the simulation of an infested crop field. Then, in a second step, a world to camera transformation is applied to allow every kind of picture (with or without perspective effect). The validation of this model was …
Full parallax three-dimensional display from Kinect v1 and v2
2016
We exploit the two different versions of Kinect, v1 and v2, for the calculation of microimages projected onto integral-imaging displays. Our approach is based on composing a three-dimensional (3-D) point cloud from a captured depth map and RGB information. These fused 3-D maps permit to generate an integral image after projecting the information through a virtual pinhole array. In our analysis, we take into account that each of the Kinect devices has its own inherent capacities and individualities. We illustrate our analysis with some imaging experiments, provide the distinctive differences between the two Kinect devices, and finally conclude that Kinect v2 allows the display of 3-D images …
Subtractive imaging in confocal scanning microscopy using a CCD camera as a detector
2012
[EN] We report a scheme for the detector system of confocal microscopes in which the pinhole and a large-area detector are substituted by a CCD camera. The numerical integration of the intensities acquired by the active pixels emulates the signal passing through the pinhole. We demonstrate the imaging capability and the optical sectioning of the system. Subtractive-imaging confocal microscopy can be implemented in a simple manner, providing superresolution and improving optical sectioning. (C) 2012 Optical Society of America
Femtosecond digital lensless holographic microscopy to image biological samples
2013
The use of femtosecond laser radiation in digital lensless holographic microscopy (DLHM) to image biological samples is presented. A mode-locked Ti:Sa laser that emits ultrashort pulses of 12 fs intensity FWHM, with 800 nm mean wavelength, at 75 MHz repetition rate is used as a light source. For comparison purposes, the light from a light-emitting diode is also used. A section of the head of a drosophila melanogaster fly is studied with both light sources. The experimental results show very different effects of the pinhole size on the spatial resolution with DLHM. Unaware phenomena on the field of the DLHM are analyzed.
X-ray imaging of the heating zone of non-normal incidence pumped XRL plasma
2006
Soft x-ray emission, above 600 eV, from a grazing incidence pumped Ni-like Mo x-ray laser (GRIP-XRL) [1] plasma was investigated. Using a pinhole camera looking along the target surface, perpendicular to the direction of the XRL emission, spatially-resolved information was obtained with a resolution which was limited only by the pinhole size of 10 μm. The relative distance from the target surface to the plasma zone heated by th e picosecond pulse was investigated for different GRIP angles, energy ratios and delays between the plasma producing and the plasma heating pulses.
Comparison of two portable solid state detectors with an improved collimation and alignment device for mammographic x-ray spectroscopy
2006
We describe a portable system for mammographic x-ray spectroscopy, based on a 2 X 2 X 1 mm3 cadmium telluride (CdTe) solid state detector, that is greatly improved over a similar system based on a 3 X 3 X 2 mm3 cadmium zinc telluride (CZT) solid state detector evaluated in an earlier work. The CdTe system utilized new pinhole collimators and an alignment device that facilitated measurement of mammographic x-ray spectra. Mammographic x-ray spectra acquired by each system were comparable. Half value layer measurements obtained using an ion chamber agreed closely with those derived from the x-ray spectra measured by either detector. The faster electronics and other features of the CdTe detecto…