Search results for "resolution"
showing 10 items of 1928 documents
Lineshapes and optical selectivity in high-resolution double-resonance ionization mass spectrometry
1999
Abstract Lineshapes expected in high-resolution double-resonance ionization spectroscopy are calculated using the density matrix formalism, integrated over experimentally realistic conditions including atomic velocity and angular distributions as well as laser intensity profiles. The results of these calculations are compared with experimental measurements on the system 4s2 1S0 → 4s4p 1P1 → 4s4d 1D1 → ion for calcium. The measurements of lineshape, with a dynamic range of >106, reveal and confirm subtle effects predicted by theory. These include the shape, position and intensity of the laser-induced structure in the spectra and the simultaneous presence of coherent and incoherent excitation…
A PLE-based resolution of cocaine, pseudococaine, and 6- and 7-methoxylated cocaine analogues
1996
Abstract The enzymatic hydrolysis of racemic cocaine and cocaine analogues using pig liver esterase (PLE) is shown to afford a practical means for achieving their chemical resolution. This reaction was found to proceed not only with good enantioselectivity, but with an interesting chemoselectivity as well.
Spectrophotometric analysis of mixtures of two components with extensively or completely overlapping spectra by the H-point standard additions method
1990
This paper discusses the requirements and scope of application of the H-Point Standard Additions Method (HPSAM) for resolving binary mixtures. Various mixtures of dyes with extensively or completely overlapping spectra were assayed with accurate, precise results. The method thus developed was also applied to the spectrophotometric resolution of binary mixtures of phenol and o-cresol, the absorption bands of which lie in similar positions and feature similar absorptivities.
Optimization of a LC method for the enantioseparation of a non-competitive glutamate receptor antagonist, by experimental design methodology
2006
Abstract The aim of this work was to obtain the direct optical resolution of a new glutamate receptor antagonist (( p -chloro)1-aryl-6,7,-dimethoxy-1,2,3,4-tetrahydroisoquinoline, PS3), by liquid chromatography on Chiralcel ® OD column. A response surface methodology (RSM) was employed to optimize the enantiomeric separation of the racemate with the lowest number of experiments; in particular, a face-centred design (FCD) was applied to evaluate the influence of critical parameters on the experimental response. Furthermore, in order to find the best compromise between several responses, a multicriteria decision-making approach, the Derringer's desirability function, was successful to simulta…
Potential of human serum albumin as chiral selector of basic drugs in affinity electrokinetic chromatography-partial filling technique
2006
The enantiomeric resolution of compounds using HSA by means of affinity EKC (AEKC)-partial filling technique is the result of a delicate balance between different experimental variables such as protein concentration, running pH (background electrophoretic buffer (BGE), protein, and compound solutions), and plug length. In this paper, the possibility of using HSA as chiral selector for enantioseparation of 28 basic drugs using this methodology is studied. The effect of the physicochemical parameters, the structural properties of compounds, and compound-HSA protein binding percentages over their chiral resolution with HSA is outlined. Based on the results obtained, a decision tree is proposed…
Estuarine sediment quality assessment by Fourier-transform infrared spectroscopy
2010
Partial least squares Fourier-transform infrared (PLS-FTIR) models were developed for the quality assessment of estuarine sediments through the evaluation of several physico-chemical parameters. Models were based on the chemometric treatment of attenuated total reflection (ATR) spectra directly obtained from samples previously lyophilized and sieved through a lower than 63 μm grid. Spectra were scanned from 3997 to 523 cm-1, averaging 36 scans per spectrum with a nominal resolution of 8 cm-1. Models were built using reference data obtained for sediment samples collected from Ria de Arousa estuary. Hierarchical cluster classification of sediment ATR spectra was employed for the establishment…
Characterization of the alcoholic fraction of vegetable oils by derivatization with diphenic anhydride followed by high-performance liquid chromatogr…
2008
Abstract Aliphatic and triterpene alcohols present in vegetable oils have been identified and determined by HPLC using UV–vis and MS detection after previous derivatization with diphenic anhydride. The alcoholic fraction was obtained by saponification, extraction and TLC (according to the European Union official procedure). Derivatization was performed in tetrahydrofuran in the presence of suspended grinded urea, which increases the reaction rate and yield. Derivatized extracts were chromatographed on a C8 column using gradient elution with acetonitrile/water mixtures containing 0.1% acetic acid, with UV–vis followed by negative-ion mode MS detection. Using linear discriminant analysis of t…
Trace analysis by ion mobility spectrometry: From conventional to smart sample preconcentration methods. A review.
2018
Ion mobility spectrometry (IMS) is a rapid and high sensitive technique widely used in security and forensic areas. However, a lack of selectivity is usually observed in the analysis of complex samples due to the scarce resolution of the technique. The literature concerning the use of conventional and novel smart materials in the pretreatment and preconcentration of samples previous to IMS determinations has been critically reviewed. The most relevant strategies to enhance selectivity and sensitivity of IMS determinations have been widely discussed, based in the use of smart materials, as immunosorbents, aptamers, molecularly imprinted polymers (MIPs), ionic liquids (ILs) and nanomaterial. …
Comparative modelling study on enantioresolution of structurally unrelated compounds with amylose-based chiral stationary phases in reversed phase li…
2020
[EN] Polysaccharide-based chiral stationary phases (CSPs) are the most used chiral selectors in HPLC. These CSPs can be used in normal, polar organic and aqueous-organic mobile phases. However, normal and polar organic mobile phases are not adequate for chiral separation of polar compounds, for the analysis of aqueous samples and for MS detection. In these situations, reversed phase conditions, without the usual non-volatile additives incompatible with MS detection, are preferable. Moreover, in most of the reported chiral chromatographic methods, retention is too large for routine work. In this paper, the chiral separation of 53 structurally unrelated compounds is studied using three commer…
High-performance liquid chromatographic separation of modified and native melittin following transglutaminase-mediated derivatization with a dansyl f…
1991
Abstract The 26-amino acid linear, amphiphilic peptide melittin was enzymatically modified with the fluorescent probe monodansylcadaverine using guinea pig liver transglutaminase and a fluorescent derivative of stoichiometry 1:1 was obtained. Reversed-phase and size-exclusion high-performance liquid chromatographic modes were tested in order to resolve the labelled peptide and native species. The influence of several operational variables was analysed and the elution conditions were optimized so that a satisfactory resolution could be achieved in both instances in a rapid, easy manner. Both chromatographic modes offer the possibility of accurate monitoring of the time course of the enzyme-m…