Search results for "sers"
showing 10 items of 478 documents
Observing heme doming in myoglobin with femtosecond X-ray absorption spectroscopy.
2015
International audience; We report time-resolved X-ray absorption measurements after photolysis of carbonmonoxy myoglobin performed at the LCLS X-ray free electron laser with nearly 100 fs (FWHM) time resolution. Data at the Fe K-edge reveal that the photoinduced structural changes at the heme occur in two steps, with a faster (∼70 fs) relaxation preceding a slower (∼400 fs) one. We tentatively attribute the first relaxation to a structural rearrangement induced by photolysis involving essentially only the heme chromophore and the second relaxation to a residual Fe motion out of the heme plane that is coupled to the displacement of myoglobin F-helix
Current status of AlInN layers lattice-matched to GaN for photonics and electronics
2007
We report on the current properties of Al1-x InxN (x approximate to 0.18) layers lattice- matched ( LM) to GaN and their specific use to realize nearly strain- free structures for photonic and electronic applications. Following a literature survey of the general properties of AlInN layers, structural and optical properties of thin state- of- the- art AlInN layers LM to GaN are described showing that despite improved structural properties these layers are still characterized by a typical background donor concentration of ( 1 - 5) x 10(18) cm(-3) and a large Stokes shift (similar to 800 meV) between luminescence and absorption edge. The use of these AlInN layers LM to GaN is then exemplified …
Blue lasing at room temperature in high quality factor GaN/AlInN microdisks with InGaN quantum wells
2007
The authors report on the achievement of optically pumped III-V nitride blue microdisk lasers operating at room temperature. Controlled wet chemical etching of an AlInN interlayer lattice matched to GaN allows forming inverted cone pedestals. Whispering gallery modes are observed in the photoluminescence spectra of InGaN/GaN quantum wells embedded in the GaN microdisks. Typical quality factors of several thousands are found (Q>4000). Laser action at similar to 420 nm is achieved under pulsed excitation at room temperature for a peak power density of 400 kW/cm(2). The lasing emission linewidth is down to 0.033 nm.
A laser-based system for a fast and accurate measurement of gain and linearity of photomultipliers
2018
This paper describes a method for the measurement of gain and linearity of photomultipliers (PMTs). Gain and linearity are two fundamental parameters to use properly a PMT in several physics experiments. In the developed system light is laser generated and adressed to the PMT through a set of optical fibers. The data acquisition system consists in a commercial 16 channel digitizer coupled to a custom front-end board. With the chosen digitizer the system is scalable to test up to 16 PMTs, with the aid of a light distribution system and a multi-channel version of the front-end board. Data analysis is performed by a custom acquisition software. A 1.5» Hamamatsu PMT is used to validate the syst…
Nanoparticle One-Dimensional Photonic-Crystal Dye Laser
2009
The stimulated emission from an organic dye adsorbed within the void network of a NP 1D (photonic crystals) PC, was studied. The nanoparticle one-dimensional photonic crystals (NP 1DPCs) were assembled by polyelectrolyte-assisted layer-by-layer deposition with subsequent calcination of the films to remove the polymer components. Each layer was prepared by spin-coating a block-copolymer-templated titania- or silica-based sol solution followed by a calcination step. To maximize the photonic-crystal effect, PCs consisting of eleven bilayers, compared to the four-bilayer NP 1D PCs, were fabricated with good structural and optical quality over 2 cm ×2 cm areas. The effective refractive index of …
Subpicosecond transient signal spectroscopy of Prodan in dimethylformamide solution.
2008
We report a pump-probe experiment revealing the temporal evolution of subpicosecond evolution of Prodan's excited-state absorption in dimethylformamide. Also, we present calculation of the first spectral moment of this spectral band and estimation of different relaxation components on the subpicosecond time scale.
Visualizing a protein quake with time-resolved X-ray scattering at a free-electron laser
2014
We describe a method to measure ultrafast protein structural changes using time-resolved wide-angle X-ray scattering at an X-ray free-electron laser. We demonstrated this approach using multiphoton excitation of the Blastochloris viridis photosynthetic reaction center, observing an ultrafast global conformational change that arises within picoseconds and precedes the propagation of heat through the protein. This provides direct structural evidence for a 'protein quake': the hypothesis that proteins rapidly dissipate energy through quake-like structural motions. peerReviewed
Nanosecond-level time synchronization of autonomous radio detector stations for extensive air showers
2016
To exploit the full potential of radio measurements of cosmic-ray air showers at MHz frequencies, a detector timing synchronization within 1 ns is needed. Large distributed radio detector arrays such as the Auger Engineering Radio Array (AERA) rely on timing via the Global Positioning System (GPS) for the synchronization of individual detector station clocks. Unfortunately, GPS timing is expected to have an accuracy no better than about 5 ns. In practice, in particular in AERA, the GPS clocks exhibit drifts on the order of tens of ns. We developed a technique to correct for the GPS drifts, and an independent method is used to cross-check that indeed we reach a nanosecond-scale timing accura…
Absolute momentum calibration of the HARP TPC
2008
In the HARP experiment the large-angle spectrometer is using a cylindrical TPC as main tracking and particle identification detector. The momentum scale of reconstructed tracks in the TPC is the most important systematic error for the majority of kinematic bins used for the HARP measurements of the double-differential production cross-section of charged pions in proton interactions on nuclear targets at large angle. The HARP TPC operated with a number of hardware shortfalls and operational mistakes. Thus it was important to control and characterize its momentum calibration. While it was not possible to enter a direct particle beam into the sensitive volume of the TPC to calibrate the detect…
Alignment of the ALICE Inner Tracking System with cosmic-ray tracks
2010
ALICE (A Large Ion Collider Experiment) is the LHC (Large Hadron Collider) experiment devoted to investigating the strongly interacting matter created in nucleus-nucleus collisions at the LHC energies. The ALICE ITS, Inner Tracking System, consists of six cylindrical layers of silicon detectors with three different technologies; in the outward direction: two layers of pixel detectors, two layers each of drift, and strip detectors. The number of parameters to be determined in the spatial alignment of the 2198 sensor modules of the ITS is about 13,000. The target alignment precision is well below 10 micron in some cases (pixels). The sources of alignment information include survey measurement…