Search results for "silicon photomultiplier"
showing 10 items of 87 documents
Characterisation of radiation damage in silicon photomultipliers with a Monte Carlo model
2008
Measured response functions and low photon yield spectra of silicon photomultipliers (SiPM) were compared to multi-photoelectron pulse-height distributions generated by a Monte Carlo model. Characteristic parameters for SiPM were derived. The devices were irradiated with 14 MeV electrons at the Mainz microtron MAMI. It is shown that the first noticeable damage consists of an increase in the rate of dark pulses and the loss of uniformity in the pixel gains. Higher radiation doses reduced also the photon detection efficiency. The results are especially relevant for applications of SiPM in fibre detectors at high luminosity experiments.
Noise and radiation damage in silicon photomultipliers exposed to electromagnetic and hadronic radiation
2009
For the electron arm tracking system in the KAOS spectrometer at the Mainz Microtron MAMI a detector based on 2 m long scintillating fibres read out by silicon photomultipliers (SiPM) is planned. Because of the detector's close proximity to the intense electron beam a study of noise and radiation damage in SiPM has been performed. A sample of devices was exposed directly to a 14 MeV electron beam and to a mixed radiation field in the experimental area. First noticeable effects are a large increase in the dark count rate and a severe loss of the gain uniformity.
Extensive electrical model of large area silicon photomultipliers
2011
Abstract In this paper the full electrical model of silicon photomultipliers fabricated at STMicroelectronics Catania R&D clean room facilities is presented. An accurate investigation on both SiPM single microcell and entire SiPM structure to extrapolate all the electrical elements has been executed by means of dedicated characterizations carried out on appropriate layout structure. The electrical simulations results are compared to the experimental data showing a good fit and therefore verifying the accuracy of the proposed model. This model can be used to describe all the SiPMs with different sizes manufactured using the same technology. Moreover, starting from this extensive electrical m…
Gain stabilization and noise minimization for SiPMs at cryogenic temperatures
2018
Abstract The performance of solid-state photon detectors such as avalanche photodiodes or silicon photomultipliers (SiPMs) is strongly affected by temperature. Important device characteristics for the detection of low light levels or single photons are photon detection efficiency, dark noise, and gain. In the present work the C-series SiPMs from SensL was characterized in cryogenic environments. At 77 K the SiPMs proved to be an excellent choice for single photon detection and an operation point with minimum noise contributions was found. At 4 K the performance was degraded, exhibiting a smaller gain and a larger noise.
AX-PET: A novel PET concept with G-APD readout
2012
Abstract The AX-PET collaboration has developed a novel concept for high resolution PET imaging to overcome some of the performance limitations of classical PET cameras, in particular the compromise between spatial resolution and sensitivity introduced by the parallax error. The detector consists of an arrangement of long LYSO scintillating crystals axially oriented around the field of view together with arrays of wave length shifter strips orthogonal to the crystals. This matrix allows a precise 3D measurement of the photon interaction point. This is valid both for photoelectric absorption at 511 keV and for Compton scattering down to deposited energies of about 100 keV. Crystals and WLS s…
Measurement of the response of Silicon Photomultipliers from single photon detection to saturation
2019
Abstract The development of Silicon Photomultipliers (SiPM) is very dynamic and a large variety of types exists. Important SiPM characteristics include the size and number of pixels, the gain, the photon detection efficiency (PDE), the recovery time, and correlated noise. SiPMs are particularly suitable for single-photon detection and low-intensity exposures. For photon numbers (PDE corrected) reaching the number of pixels, however, the sensors saturate. In this work, we present comprehensive response measurements for state-of-the-art SiPMs using an experimental setup based on a tunable picosecond laser. Several models are applied to the measured response curves, taking particularly correla…
A low-noise and fast pre-amplifier and readout system for SiPMs
2015
Abstract To operate silicon photomultipliers (SiPMs) in a demanding environment with large temperature gradients, different amplifier concepts were characterized by analyzing SiPM pulse-shapes and charge distributions. A fully differential 4-wire SiPM pre-amplifier with separated tracks for the bias voltage and with good common-mode noise suppression was developed and successfully tested. To achieve highest single-pixel resolutions an online after-pulse and pile-up suppression was realized with fast readout electronics based on digital filters.
The AX-PET demonstrator—Design, construction and characterization
2011
Abstract Axial PET is a novel geometrical concept for Positron Emission Tomography (PET), based on layers of long scintillating crystals axially aligned with the bore axis. The axial coordinate is obtained from arrays of wavelength shifting (WLS) plastic strips placed orthogonally to the crystals. This article describes the design, construction and performance evaluation of a demonstrator set-up which consists of two identical detector modules, used in coincidence. Each module comprises 48 LYSO crystals of 100 mm length and 156 WLS strips. Crystals and strips are readout by Geiger-mode Avalanche Photo Diodes (G-APDs). The signals from the two modules are processed by fully analog front-end …
The large-area hybrid-optics CLAS12 RICH detector: Tests of innovative components
2014
A large area ring-imaging Cherenkov detector has been designed to provide clean hadron identification capability in the momentum range from 3 GeV/c to 8 GeV/c for the CLAS12 experiments at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Lab to study the 3D nucleon structure in the yet poorly explored valence region by deep-inelastic scattering, and to perform precision measurements in hadronization and hadron spectroscopy. The adopted solution foresees a novel hybrid optics design based on an aerogel radiator, composite mirrors and densely packed and highly segmented photon detectors. Cherenkov light will either be imaged directly (forward tracks) or after two…
Timing results using an FPGA-based TDC with large arrays of 144 SiPMs
2015
Silicon photomultipliers (SiPMs) have become an alternative to traditional tubes due to several features. However, their implementation to form large arrays is still a challenge especially due to their relatively high intrinsic noise, depending on the chosen readout. In this contribution, two modules composed of SiPMs with an area of roughly mm mm are used in coincidence. Coincidence resolving time (CRT) results with a field-programmable gate array, in combination with a time to digital converter, are shown as a function of both the sensor bias voltage and the digitizer threshold. The dependence of the CRT on the sensor matrix temperature, the amount of SiPM active area and the crystal type…