Search results for "solid phase"
showing 10 items of 360 documents
Comparison of the solid-phase extraction efficiency of a bounded and an included cyclodextrin-silica microporous composite for polycyclic aromatic hy…
2016
Solid-phase extraction is one of the most important techniques for sample purification and concentration. A wide variety of solid phases have been used for sample preparation over time. In this work, the efficiency of a new kind of solid-phase extraction adsorbent, which is a microporous material made from modified cyclodextrin bounded to a silica network, is evaluated through an analytical method which combines solid-phase extraction with high-performance liquid chromatography to determine polycyclic aromatic hydrocarbons in water samples. Several parameters that affected the analytes recovery, such as the amount of solid phase, the nature and volume of the eluent or the sample volume and …
Ultrasonically-Assisted and Conventional Extraction from Erodium Glaucophyllum Roots Using Ethanol:Water Mixtures: Phenolic Characterization, Antioxi…
2020
The paper presents experimental results concerning the ultrasonically-assisted extraction of bioactive compounds from Erodium glaucophyllum roots. A comparison with conventional methodology is presented, and thereby the phytochemical composition and the antioxidant and anti-inflammatory activities of extracts are evaluated. The phenolic profile of Erodium extracts was analyzed by TOF&ndash
A no-carrier-added72Se/72As radionuclide generator based on solid phase extraction
2005
Summary72As-labelled radiopharmaceuticals could be a valuable resource for Positron Emission Tomography (PET). In particular, the long half-life of72As (T1/2= 26 h) facilitates the observation of long-term physiological or metabolic processes, such as the enrichment and distribution of antibodies in tumor tissue. This work describes the primary radiochemical separation of no-carrier-added (nca)72Se from cyclotron irradiated germanium targets and the development of a polystyrene type solid-phase extraction based72Se/72As radionuclide generator, avoiding the addition of any selenium carrier. The irradiated germanium target is dissolved in HFconcand selenium is reduced with hydrazine dihydroch…
Fundamentals and applications of stir bar sorptive dispersive microextraction: A tutorial review
2021
Current trends in sample preparation focus on the miniaturization of the process resulting in what is known as microextraction techniques. Among them stir bar sorptive dispersive microextraction (SBSDME) is one of the most recent techniques. It was presented a few years ago as a hybrid microextraction technique that combines the principles of stir bar sorptive extraction (SBSE) and dispersive solid phase extraction (DSPE). This novel technique introduces, into the sample solution, a bar-shaped magnet coated with a magnetic (nano)material, which is maintained on the surface by magnetism. Once stirring starts, the competitive action between magnetism and rotational force is exploited. At low …
Determination of phenytoin in plasma by molecularly imprinted solid-phase extraction.
2001
Abstract A molecularly imprinted polymer (MIP) using phenytoin as template and methacrylamide as the functional monomer was prepared. The selectivity was measured by comparing capacity factors of phenytoin and other structurally related compounds. The polymer was evaluated as a selective sorbent in molecularly imprinted solid-phase extraction (MISPE). Several washing solvents were tested to study their ability to disrupt the non-specific interactions occurring between the sample and the polymer matrix and the role of water in the recognition process was also investigated. It was shown that the key step of successful sample extraction is the right choice of the washing solvent. Plasma sample…
A class-selective immunoassay for simultaneous analysis of anilinopyrimidine fungicides using a rationally designed hapten
2017
he development of multianalyte immunoassays constitutes a main research issue in the field of bioanalytical techniques. In the present study, class-specific antibodies against the three members of the anilinopyrimidine family of fungicides (pyrimethanil, cyprodinil and mepanipyrim) were raised by using a bioconjugate of a rationally designed hapten [5-(6-methyl-2-(phenylamino)pyrimidin-4-yl)pentanoic acid]. Highly sensitive immunoassays were developed for the generic determination of these compounds, using the competitive enzyme-linked immunosorbent assay (ELISA). Particularly, a direct antibody-coated competitive ELISA afforded identical sensitivity for the three anilinopyrimidines, with I…
Combination of supported liquid membrane and solid-phase extraction for sample pretreatment of triazine herbicides in juice prior to capillary electr…
2002
A possibility of a combination of supported liquid membrane (SLM) and solid-phase extraction (SPE) for the determination of atrazine at microgram level in different type of fruit juices is presented. In comparison to SPE extraction from juice samples, the application of SLM-SPE enrichment provides much cleaner extracts and the possibility of lowering the limit of detection as low as 30 microg/l. However, it was also shown that by appropriate manipulation of SLM extraction conditions mainly flow-rate of donor phase and volume ratio between donor and acceptor phase, the level of detection can be further decreased to 10 microg/l. The results suggest that the application of SLM extraction prior…
A sustainable on-line CapLC method for quantifying antifouling agents like irgarol-1051 and diuron in water samples: Estimation of the carbon footpri…
2016
In this work, in-tube solid phase microextraction (in-tube SPME) coupled to capillary LC (CapLC) with diode array detection has been reported, for on-line extraction and enrichment of booster biocides (irgarol-1051 and diuron) included in Water Frame Directive 2013/39/UE (WFD). The analytical performance has been successfully demonstrated. Furthermore, in the present work, the environmental friendliness of the procedure has been quantified by means of the implementation of the carbon footprint calculation of the analytical procedure and the comparison with other methodologies previously reported. Under the optimum conditions, the method presents good linearity over the range assayed, 0.05-1…
A miniaturized method for estimating di(2-ethylhexyl) phthalate in bivalves as bioindicators.
2012
This work has developed a miniaturized method based on matrix solid phase dispersion (MSPD), using C18 as dispersant and acetonitrile-water as eluting solvent, for the analysis of di(2-ethylhexyl) phthalate (DEHP) in biota samples by capillary liquid chromatography coupled to in-tube solid phase microextraction and diode array detection. Recovery studies showed that the combination of C18-Florisil® was optimal using low amount of samples (0.1 g) and with low volumes of acetonitrile-water (2.6 mL 1:3.25, v/v). The sample is processed in less than 30 min, no evaporation step is required. The proposed method was applied to the analysis of DEHP in mussels and of the coastal waters in which they…
Isolation and identification of intermediates from biodegradation of low chlorinated biphenyls (Delor-103).
2004
Abstract Microorganism Pseudomonas species P2 metabolizes polychlorinated biphenyls (PCBs) and biphenyl, producing the whole spectrum of intermediates, among them coloured intermediates, which are suitable for the monitoring of PCBs degradation by optical sensors. Knowledge of chemical structures and conditions of development of colour metabolites is necessary for application of optical analytical methods. The main goal of this work was the isolation and identification of intermediates from the biodegradation of the mixture of low chlorinated biphenyls (Delor-103), which is based on the solid phase extraction (SPE) of the whole mixture using LiChrolut EN cartridges, then silylation of the e…