Search results for "solid-phase extraction"
showing 10 items of 24 documents
Analysis of cannabinoids by liquid chromatography–mass spectrometry in milk, liver and hemp seed to ensure food safety
2017
A method for determining cannabinoids, Δ9-tetrahidrocannabinol (THC), 11-nor-9-carboxy-Δ9-THC (THC-COOH) and 11-hidroxy-Δ9-THC (THC-OH) in milk, liver and hemp seeds based on liquid chromatography tandem mass spectrometry has been optimized and validated. Analytes were extracted with methanol and the extracts cleaned-up by solid-phase extraction using Oasis HLB (60 mg). The developed method was validated according to the Commission Decision 2002/657/EC. The decision limit (CCα) and detection capability (CCβ) ranged from 3.10–10.5 ng g−1 and 3.52–11.5 ng g−1, the recoveries were 76–118% and matrix effect ranged from −17.8% to 19.9% in the three matrices studied. The method was applied to foo…
Multi‐residue extraction to determine organic pollutants in mussel hemolymph
2021
This study assesses the extraction of eleven pharmaceuticals, five pesticides, five perfluoroalkyl substances, and two illicit drugs in hemolymph from (Mytilus Galloprovincialis). Four extraction procedures using Phree™ Phospholipid Removal cartridges were tested using different volumes of methanol (400 and 600 μL) and acetonitrile (300 and 450 μL). The pollutants were determined by high-performance liquid chromatography–tandem mass spectrometry. The use of methanol gave several problems during the extraction procedure, such as longer times and sample loss. Three methods (acetonitrile 300 and 450 μL; and methanol 600 μL) were validated. Recoveries at three concentration levels (5, 50, and 1…
Highly selective recovery of Ni(II) in neutral and acidic media using a novel Ni(II)-ion imprinted polymer
2022
In this work, an original ion-imprinted polymer (IIP) was synthetized for the highly selective removal of Ni(II) ions in neutral and acidic media. First a novel functional monomer (AMP-MMA) was synthetized through the amidation of 2-(aminomethyl)pyridine (AMP) with methacryloylchloride. Following Ni(II)/AMP-MMA complex formation study, the Ni(II)-IIP was produced via inverse suspension polymerization (DMSO in mineral oil) and characterized with solid state 13C CPMAS NMR, FT-IR, SEM and nitrogen adsorption/desorption experiments. The Ni(II)-IIP was then used in solid-phase extraction of Ni(II) exploring a wide range of pH (from neutral to strongly acidic solution), several initial concentrat…
Polymeric monolithic microcartridges with gold nanoparticles for the analysis of protein biomarkers by on-line solid-phase extraction capillary elect…
2020
In this study, polymeric monoliths with gold nanoparticles (AuNP@monolith) were investigated as microcartridges for the analysis of protein biomarkers by on-line solid-phase extraction capillary electrophoresis-mass spectrometry (SPE-CE-MS). “Plug-and-play” microcartridges (7 mm) were prepared from a glycidyl methacrylate (GMA)-based monolithic capillary column (5 cm x 250 µm i.d.), which was modified with ammonia and subsequently functionalized with gold nanoparticles (AuNPs). The performance of these novel microcartridges was evaluated with human transthyretin (TTR), which is a protein related to different types of familial amyloidotic polyneuropathies (FAP). Protein retention depended on…
Surface molecularly imprinted silica for selective solid-phase extraction of biochanin A, daidzein and genistein from urine samples
2015
Selective molecularly imprinted silica polymer (SiO2MIP) for extraction of biochanin A, daidzein and genistein was synthesized using the surface molecular imprinting technique with the silica gel as a support. Biochanin A (BCA) was used as a template, 3-aminopropyltriethoxysilane (APTES) as a functional monomer, and tetraethoxysilicane (TEOS) as a cross-linker. Non-imprinted polymer with the sol–gel process (SiO2NIP) was also prepared for comparison. The synthesized polymers were characterized by Fourier transform infrared spectrometry (FTIR), scanning electron microscopy (SEM) and a standard Brunauer-Emett-Teller (BET) and Barret–Joyner–Halenda (BJH) analysis. The obtained results indicate…
The application of the supported liquid membrane and molecularly imprinted polymers as solid acceptor phase for selective extraction of biochanin A f…
2018
An efficient sample clean-up and preconcentration procedure for phytoestrogens analysis in urine has been developed. It was based on a combination of solid phase extraction with hollow-fiber supported liquid membrane and molecularly imprinted beads (MIPs-HF-SLM-SPE). The molecularly imprinted polymers (MIPs) were synthesized by precipitation polymerization technique with biochanin A (BCA) as a template, giving narrowly dispersed microspheres with a regular shape. As the functional monomer, (dimethylamino)ethyl methacrylate (-DEM) turned out to be better than methacrylic acid (MAA) to get the best-imprinted effects. The MIPs used as sorbents in the MIPs-HF-SLM-SPE extraction process exhibite…
Recent Advances in Affinity MOF-Based Sorbents with Sample Preparation Purposes
2020
This review summarizes the recent advances concerning metal–organic frameworks (MOFs) modified with several biomolecules (e.g., amino acids, nucleobases, proteins, antibodies, aptamers, etc.) as ligands to prepare affinity-based sorbents for application in the sample preparation field. The preparation and incorporation strategies of these MOF-based affinity materials were described. Additionally, the different types of ligands that can be employed for the synthesis of these biocomposites and their application as sorbents for the selective extraction of molecules and clean-up of complex real samples is reported. The most important features of the developed biocomposites will be discussed thr…
Are analysts doing method validation in liquid chromatography?
2014
International audience; Method validation is being applied in the reported analytical methods for decades. Even before this protocol was defined, authors already somehow validated their methods without full awareness. They wished to assure the quality of their work. Validation is an applied approach to verify that a method is suitable and rugged enough to function as a quality control tool in different locations and times. The performance parameters and statistical protocols followed throughout a validation study vary with the source of guidelines. Before single laboratory validation, an analytical method should be fully developed and optimized. The purpose of the validation is to confirm p…
Determination of benzomercaptans in environmental complex samples by combining zeolitic imidazolate framework-8-based solid-phase extraction and high…
2020
[EN] In this work, the synthesis of zeolitic imidazolate framework-8 (ZIF-8) crystals and their subsequent application as effective sorbents for extraction and preconcentration of several benzomercaptans from environmental complex samples is described. These materials were prepared by solvothermal approach varying the concentration of n-butylamine modulator to modify the surface of the metal-organic framework. The resulting materials were characterized by scanning and transmission electron microscopy, powder X-ray diffraction and Fourier transform infrared spectroscopy. The ZIF-8 material that gave the best features was selected as extractive phase and the influence of various parameters (s…
Determination of phenolic compounds in surface waters using high-performance liquid chromatography and molecularly imprinted solid-phase extraction
2021
An effective and reliable analytical method based on molecularly imprinted solid-phase extraction (MI-SPE) and high-performance liquid chromatography with photodiode array detector was developed to simultaneously determine four phenolic compounds: bisphenol A, 2-phenylphenol, tert-octylphenol and nonylphenol. A molecularly imprinted polymer that can selectively recognize bisphenol A and alkylphenols was developed. A bulk polymerization method using bisphenol A as a template, acrylamide as functional monomer, ethylene glycol dimethacrylate as the cross-linking agent, acetonitrile as porogenic solvent and 1,1’-azobis(cyclohexanecarbonitrile) as initiator was applied. This polymer was applied …