Search results for "zircon"

showing 10 items of 693 documents

Bond strength evaluation of the veneering-core ceramics bonds.

2009

The purpose of this study was to determine whether the bond of veneering porcelain to a ceramic core in bilayered ceramics was similar to that of the metal ceramic control of well known behaviour. Six groups of nine specimens each were fabricated, whose dimensions were 15 mm long and 8 mm in diameter at the core, and 2 mm long and 8 mm in diameter for the veneer. The groups were GR. 1 (control group): CrNi alloy/d.SIGN (Ivoclar), GR. 2: IPS e.maxPress/IPS e.maxCeram (Ivoclar), GR. 3: IPS e.maxZirCad/ IPS e.maxZirPress (Ivoclar), GR. 4: IPS e.maxZirCad/IPS e.maxCeram (Ivoclar), GR. 5: Lava Frame (3M ESPE)/ Lava Ceram (3M ESPE) and GR. 6: Lava Frame (3M ESPE)/IPS e.maxCeram (Ivoclar). A shear…

CeramicsMaterials scienceShear strength testmedicine.medical_treatmentMateriales dentalesOdontologíaCIENCIA DE LOS MATERIALES E INGENIERIA METALURGICAmedicineCeramicComposite materialGeneral DentistryBond strengthUniversal testing machineBond strengthDental Bonding:CIENCIAS MÉDICAS [UNESCO]CeramicCore (optical fiber)Dental VeneersOtorhinolaryngologyvisual_artUNESCO::CIENCIAS MÉDICASShear testvisual_art.visual_art_mediumZirconiaSurgeryVeneerAdhesiveDirect shear testMedicina oral, patologia oral y cirugia bucal
researchProduct

Influence of the chemical composition of monolithic zirconia on its optical and mechanical properties. Systematic review and meta-regression.

2021

Este artículo se encuentra disponible en la siguiente URL: https://www.jstage.jst.go.jp/article/jpr/66/2/66_JPR_D_20_00218/_pdf/-char/en Este artículo de investigación pertenece al número especial "Advances in Personalized Nursing Care". Purpose: This systematic review set out to investigate the influence of chemical composition and specimen thickness of monolithic zirconia on its optical and mechanical properties. Meta-analysis and meta-regression analyzed the effects of variations in percentages of yttrium, aluminum, and specimen thickness of monolithic zirconia. Study selection: The review followed recommendations put forward in the PRISMA checklist. An electronic search for relevant art…

CeramicsMaterials scienceWeb of scienceSurface Properties0206 medical engineeringDentistry02 engineering and technology03 medical and health sciencesDental Materials0302 clinical medicineMaterials TestingDentistry (miscellaneous)Meta-regressionCubic zirconiaYttriumCirconio - Propiedades mecánicas.Zirconium - Optical properties.business.industryMonolithic zirconia030206 dentistryCirconio - Propiedades ópticas.020601 biomedical engineeringZirconium - Mechanical properties.ZirconiumOral SurgerybusinessAluminumJournal of prosthodontic research
researchProduct

Full maxillary rehabilitation with an all-ceramic system

2009

With the appearance of all-ceramic systems, providing a choice of framework porcelains and allowing the same material to be used for the veneer, it is now possible to select the ideal structure in terms of both function and esthetics. Silicate ceramics allow porcelain laminate veneers and crowns to be used in the anterior region, providing excellent esthetics; while for the posterior area, where function takes precedence, oxide ceramics, specifically zirconium oxide, are preferred. The IPS e.max ceramic system, heir apparent to the IPS Empress 2 system, combines the advantages of zirconium oxide ceramics (IPS e.max Zircad) with the excellent esthetic qualities of silicate ceramics (IPS e.ma…

CeramicsOxide ceramicsAll ceramicDenture PartialComputer sciencemedicine.medical_treatmentMechanical engineeringDentistryAnterior regionMaxillamedicineHumansCeramicGeneral DentistryCrownsbusiness.industryMiddle Aged:CIENCIAS MÉDICAS [UNESCO]Otorhinolaryngologyvisual_artUNESCO::CIENCIAS MÉDICASZirconium oxidevisual_art.visual_art_mediumSurgeryVeneerClinical casebusinessMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Effects of femtosecond laser and other surface treatments on the bond strength of metallic and ceramic orthodontic brackets to zirconia.

2017

Femtosecond laser has been proposed as a method for conditioning zirconia surfaces to boost bond strength. However, metallic or ceramic bracket bonding to femtosecond lasertreated zirconia surfaces has not been tested. This study compared the effects of four conditioning techniques, including femtosecond laser irradiation, on shear bond strength (SBS) of metallic and ceramic brackets to zirconia.Three hundred zirconia plates were divided into five groups: 1) control (C); 2) sandblasting (APA); 3) silica coating and silane (SC); 4) femtosecond laser (FS); 5) sandblasting followed by femtosecond laser (APA+SC). A thermal imaging camera measured temperature changes in the zirconia during irrad…

CeramicsScanning electron microscopeOrthodontic Bracketslcsh:MedicineTissue AdhesionsCoating Materials030207 dermatology & venereal diseases0302 clinical medicineMedicine and Health SciencesSilaneElectron MicroscopyCubic zirconiaCeramicZirconium oxideComposite materiallcsh:ScienceMicroscopyMultidisciplinaryBond strengthBracketTemperatureOptical EquipmentMetalsvisual_artPhysical SciencesFemtosecondvisual_art.visual_art_mediumEngineering and TechnologyScanning Electron MicroscopyShear StrengthResearch ArticleMaterials scienceMaterials by StructureMaterials ScienceOral MedicineEquipmentOrthodonticsResearch and Analysis MethodsENPEP gene03 medical and health sciencesCoatingsAdhesivesShear strengthMaterials by AttributeUniversal testing machineSurface TreatmentsLaserslcsh:R030206 dentistryManufacturing ProcessesMicroscopy Electron Scanninglcsh:QZirconiumPLoS ONE
researchProduct

Fracture resistance and the mode of failure produced in metal-free crowns cemented onto zirconia abutments in dental implants.

2019

The purpose of the investigation was to analyze fracture resistance and mode of failure of zirconium oxide (zirconia) abutments placed on dental implants bearing crowns of different esthetic materials: zirconia, lithium disilicate (LDS), and nano-ceramic resin, for replacing single teeth in the anterior sector. Eighty implant-abutment-crown units were divided into four groups: Group T-MC (control): 20 metal-ceramic crowns cemented onto titanium abutments; Group Z-Z: 20 zirconia crowns on zirconia abutments; Group Z-LD: 20 lithium disilicate crowns on zirconia abutments; and Group Z-NCR: 20 nano-ceramic resin crowns on zirconia abutments. Specimens underwent a fatiguing process (dynamic load…

CeramicsTeethMedical Implantsmedicine.medical_treatmentDentistry02 engineering and technologyMaterial Fatigue0302 clinical medicineMaterials PhysicsMaterials TestingMedicine and Health SciencesCubic zirconiaDental Restoration FailureMaterialsDental CementumTitaniumProstheticsMultidisciplinaryCrownsPhysicsQRClassical Mechanics021001 nanoscience & nanotechnologyChemistryPhysical SciencesMedicineEngineering and TechnologyAnatomy0210 nano-technologyTitaniumResearch ArticleBiotechnologyChemical ElementsMaterials scienceScienceBiomaterial ImplantsMaterials ScienceAbutmentchemistry.chemical_elementBioengineeringLithiumCrown (dentistry)Anterior region03 medical and health sciencesmedicineHumansTitanium ImplantsDental ImplantsDamage Mechanicsbusiness.industryBiology and Life Sciences030206 dentistryDental PorcelainAssistive TechnologieschemistryMetal freeJawFracture (geology)Zirconium oxideMedical Devices and EquipmentZirconiumbusinessDigestive SystemHeadPloS one
researchProduct

Implant-supported metal-ceramic and resin-modified ceramic crowns: A 5-year prospective clinical study.

2018

Abstract Statement of problem Because of market demand for innovation, new restoration materials have been introduced without adequate testing; clinical failure may be the consequence, and clinical studies are needed. Purpose The purpose of this clinical study was to evaluate the biological and mechanical clinical behavior of implant-supported resin-modified ceramic crowns compared with that of metal-ceramic crowns. Material and methods Forty-two participants aged between 35 and 65 years received single implants in posterior edentulous sites. After the osseointegration period, half of the implants (selected randomly) (n=25) were restored with metal-ceramic crowns (MC group) and the other ha…

Ceramicsmedicine.medical_treatmentDentistryDental AbutmentsCrown (dentistry)Osseointegration03 medical and health sciences0302 clinical medicineDental porcelainstomatognathic systemDental AbutmentsmedicineCeramicDental Restoration FailureProspective StudiesSurvival rateDental ImplantsCrownsbusiness.industryDental prosthesis030206 dentistryDental PorcelainMetalsvisual_artvisual_art.visual_art_mediumImplantDental Prosthesis Implant-SupportedZirconiumOral SurgerybusinessThe Journal of prosthetic dentistry
researchProduct

Study of solid state kinetics using voltammetry of immobilized particles. Application to tetragonal to monoclinic transition in nanoparticulate zirco…

2012

Abstract The voltammetry of immobilized particles methodology is applied to study solid state reaction kinetics on the basis of the electrocatalytic ability of solids toward selected electrochemical processes. Measurement of the time variation of catalytic current for oxygen evolution reaction in aqueous alkaline media provides a direct estimate of fractional conversion of the reactant in the course of the reaction for testing different reaction kinetic models. This methodology is applied to analyze the formation of monoclinic zirconia and praseodymia-doped zirconia from tetragonal precursors. Discrimination between competing and successive reactions mechanisms is obtained for reactions inv…

Chemical kineticsTetragonal crystal systemAqueous solutionMaterials scienceGeneral Chemical EngineeringInorganic chemistryElectrochemistryOxygen evolutionCubic zirconiaVoltammetryCatalysisMonoclinic crystal systemElectrochimica Acta
researchProduct

Decay properties of neutron-rich niobium isotopes

1976

The decay of neutron-rich niobium isotopes in the mass region $A\ensuremath{\simeq}100$ has been investigated by $\ensuremath{\gamma}$-ray singles and $\ensuremath{\gamma}$-$\ensuremath{\gamma}$ coincidence measurements. The isotopes were produced by thermal-neutron induced fission of $^{235}\mathrm{U}$, $^{239}\mathrm{Pu}$, and $^{249}\mathrm{Cf}$, and niobium was separated from fission-product mixtures with an automated chemical procedure. Isomerism was found in the even-mass niobium isotopes with the following half-lives: 1.5 and 3.1 sec for $^{100}\mathrm{Nb}$, 1.3 and 4.3 sec for $^{102}\mathrm{Nb}$, and 0.8 and 4.8 sec for $^{104}\mathrm{Nb}$. Half-lives and $\ensuremath{\gamma}$ rays…

Chemical procedureNuclear reactionPhysicsNuclear and High Energy PhysicsZirconiumIsotopeFissionAstrophysics::High Energy Astrophysical PhenomenaNiobiumchemistry.chemical_elementChemical separationNuclear physicschemistryNeutronAtomic physicsPhysical Review C
researchProduct

Mechanical, Kinetic and Morphological Correlations during the Scale Growth of Niobium and Zirconium Oxides

2001

Oxidation of niobium at 700°C and zirconium at 850°C, in air or oxygen pressures from 20 to I 000 hPa, lead to the formation in one case of a stratified Nb 2 O 5 oxide scale and in the other case a more compact ZrO 2 oxide scale. Analyses of the evolutions of phases, crystalline textures and mechanical stresses during oxidation are determined by X-ray diffraction techniques. Interactions between chemical processes, crystalline building and mechanical processes constitute together the driving force of the reaction and can explain the differences in morphologies of oxide scales.

Chemical processZirconiumMaterials scienceMechanical EngineeringNiobiumOxidechemistry.chemical_elementMineralogyCondensed Matter PhysicsOxygenCorrosionchemistry.chemical_compoundchemistryChemical engineeringMechanics of MaterialsNiobium oxideGeneral Materials ScienceTexture (crystalline)Materials Science Forum
researchProduct

Ab initio modelling of the effects of varying Zr (Ti) concentrations on the atomic and electronic properties of stoichiometric PZT solid solutions

2017

Abstract Lead zirconate titanate Pb(ZrxTi1−x)O3 solid solution is considered as one of the most advanced ferroelectric and piezoelectric materials. Consequent variation of Zr (Ti) concentrations significantly affects the atomic and electronic properties of PZT structures. To perform ab initio modelling of different morphologies for lead zirconate titanate, we are using approach of hybrid density functional B3PW as implemented in CRYSTAL14 computer code. In this study, we are performing large-scale calculations of such PZT parameters as optimized lattice constants, atomic charges and bond populations, as well as band structure (e.g., band gap) and density of states.

ChemistryBand gapAb initioAnalytical chemistry02 engineering and technology021001 nanoscience & nanotechnologyCondensed Matter PhysicsLead zirconate titanate01 natural sciencesBiochemistryFerroelectricityComputer Science::OtherCondensed Matter::Materials Sciencechemistry.chemical_compoundLattice constantComputational chemistry0103 physical sciencesDensity of statesPhysical and Theoretical Chemistry010306 general physics0210 nano-technologyElectronic band structureSolid solutionComputational and Theoretical Chemistry
researchProduct