0000000000025117

AUTHOR

Reinhard Surkau

Polarimetry on dense samples of spin-polarized 3He by magnetostatic detection

Abstract A very sensitive low-field fluxgate magnetometer is used to detect the static magnetic field produced by dense samples of spin-polarized 3He gas contained in spherical glass cells at pressures around several bars. The 3He nuclear polarization can be extracted with high precision ΔP P by utilizing magnetostatic detection in combination with adiabatic fast-passage spin reversal. The polarization losses can be kept well below 0.1% thus making this type of polarimetry almost non-destructive. More simply even, P can be measured with reduced accuracy by the change of field when the cell is removed from the fluxgate. In this case the accuracy is limited to about 10% due to the uncertainti…

research product

Quantification of Regional Intrapulmonary Oxygen Partial Pressure Evolution during Apnea by 3He MRI

We present a new method to determine in vivo the temporal evolution of intrapulmonary oxygen concentrations by functional lung imaging with hyperpolarized (3)Helium ((3)He-->). Single-breath, single-bolus visualization of (3)He--> administered to the airspaces is used to analyze nuclear spin relaxation caused by the local oxygen partial pressure p(O(2))(t). We model the dynamics of hyperpolarization in the lung by rate equations. Based hereupon, a double acquisition technique is presented to separate depolarization by RF pulses and oxygen induced relaxation. It permits the determination of p(O(2)) with a high accuracy of up to 3% with simultaneous flip angle calibration using no additional …

research product

Interdisciplinary experiments with polarized 3He

Abstract Optical pumping of metastable 3 He atoms is a very efficient method to produce large quantities of nuclear spin-polarized 3 He. Recent developments in mechanical compression of the gas, its storage and transport allow for its flexible use in different fields of physics and applied science. Among these are (1) scattering experiments of polarized beams from polarized 3 He-targets, (2) 3 He as neutron spin filter to polarize neutron beams at research reactors, and (3) polarized 3 He gas inhaled into the lungs to perform magnetic resonance imaging. The paper discusses the different topics along with results obtained in a first round of experiments.

research product

MRI using hyperpolarized noble gases.

The aim of this study was to review the physical basis of MRI using hyperpolarized noble gases as well as the present status of preclinical and clinical applications. Non-radioactive noble gases with a nuclear spin 1/2 (He-3, Xe-129) can be hyperpolarized by optical pumping. Polarization is transferred from circularly polarized laser light to the noble-gas atoms via alkali-metal vapors (spin exchange) or metastable atoms (metastability exchange). Hyperpolarization results in a non-equilibrium polarization five orders of magnitude higher than the Boltzmann equilibrium compensating for the several 1000 times lower density of noble gases as compared with liquid state hydrogen concentrations in…

research product

Imaging of the lungs using 3he MRI: Preliminary clinical experience in 18 patients with and without lung disease

The purpose of this study was to describe the 3He MRI findings of normal pulmonary ventilation in healthy volunteers and to evaluate abnormalities in patients with different lung diseases. Hyperpolarized 3He gas (300 ml, 3 x 10(5) Pa, polarized to 35-45% by optical pumping, provided in special glass cells) was inhaled by 8 healthy volunteers and 10 patients with different lung diseases. Imaging was performed with a three-dimensional fast low-angle shot (FLASH) sequence (TR = 11.8 msec; TE = 5 msec; transmitter amplitude, 5-8 V; corresponding flip angle, < 5 degrees) in a single breath-hold (22-42 seconds). Clinical and radiological examinations were available for correlation. The studies we…

research product

Nuclear magnetic resonance imaging of airways in humans with use of hyperpolarized3He

The nuclear spin polarization of noble gases can be enhanced strongly by laser optical pumping followed by electron-nuclear polarization transfer. Direct optical pumping of metastable 3He atoms has been shown to produce enormous polarization on the order of 0.4-0.6. This is about 105 times larger than the polarization of water protons at thermal equilibrium used in conventional MRI. We demonstrate that hyperpolarized 3 He gas can be applied to nuclear magnetic resonance imaging of organs with air-filled spaces in humans. In vivo 3 He MR experiments were performed in a whole-body MR scanner with a superconducting magnet ramped down to 0.8 T. Anatomical details of the upper respiratory tract …

research product

3He-MRI-based measurements of intrapulmonarypO2 and its time course during apnea in healthy volunteers: first results, reproducibility, and technical limitations

We applied a recently developed method of following the time course of the intrapulmonary oxygen partial pressure p(O2)(t) during apnea by (3)He MRI to healthy volunteers. Using two imaging series with different interscan times during two breathholds (double acquisition technique), relaxation of (3)He due to paramagnetic oxygen and depolarization by RF pulses were discriminated. In all four subjects, the temporal evolution of p(O2) was found to be linear, and was described by an initial partial pressure p(0) and a decrease rate R. Also, regional differences of both p(0) and R were observed. A correlation between p(0) and R was apparent. Finally, we discuss limitations of the double acquisit…

research product

A dense polarized 3He target based on compression of optically pumped gas

Abstract 3 He-gas is spin polarized by the method of optical pumping of metastables and metastability exchange in a low pressure gas discharge. At a pressure of p ≈ 1.5 Torr a volume of 1 l is polarized within about 30 s to a degree of 50% with 300 mW of incident light from an argon-ion laser pumped LNA laser, tuned to the λ = 1.083 μm resonance line. The polarized gas is compressed by a Toepler pump into a target cell of 120 cm 3 volume. In a first attempt a steady state polarization of 30% has been achieved in the target at a pressure of 685 Torr. The paper analyses the essential parameters governing this technique and pilotes its experimental realization.

research product

Kernspintomographie der Lunge mit hochpolarisiertem Helium-3

Mit kernspinpolarisiertem 3He-Gas ist es moglich, das bildgebende Verfahren der Kernspintomographie auf Hohlraume auszuweiten. Fur die Lungendiagnostik eroffnen sich damit vollig neue Moglichkeiten.

research product

Helium-3-MRT der Lungenventilation: Erste klinische Anwendungen

PURPOSE: of the study is the visualisation of normal pulmonary ventilation in healthy volunteers and the evaluation of abnormalities in patients with different lung diseases using 3He magnetic resonance imaging (3He-MRI). MATERIAL AND METHODS: Hyperpolarized 3He gas (V = 300 ml, p = 3 x 10(5) Pa, polarised to 35-45% by optical pumping, provided in special glass cells) was inhaled by eight healthy volunteers and ten patients with different lung diseases. A 3D FLASH sequence (TR = 11.8 ms; TE = 5 ms; matrix 144 x 256, FOV 350 mm, section thickness 7-10 mm, coronal orientation) was performed in a single breath-hold (22-42 s). Clinical and radiological examinations were available for correlatio…

research product

Realization of a broad band neutron spin filter with compressed, polarized 3He gas

The strongly spin dependent absorption of neutrons in nuclear spin polarized 3He opens the possibility to polarize beams of thermal and epithermal neutrons. An effective 3He neutron spin filter (NSF) requires high 3He nuclear polarization as well as a filter thickness corresponding to a gas amount of the order of 1 barl. We realized such a filter using direct optical pumping of metastable 3He∗ atoms in a 3He plasma at 1 mbar. Metastable exchange scattering transfers the angular momentum to the whole ensemble of 3He atoms. At present 3 × 1018 3He-atoms/s are polarized up to 64%. Subsequent polarization preserving compression by a two stage compressor system enables to prepare NSF cells of ab…

research product

Recycling of 3He from lung magnetic resonance imaging

We have developed the means to recycle 3He exhaled by patients after imaging the lungs using magnetic resonance of hyperpolarized 3He. The exhaled gas is collected in a helium leak proof bag and further compressed into a steel bottle. The collected gas contains about 1–2% of 3He, depending on the amount administered and the number of breaths collected to wash out the 3He gas from the lungs. 3He is separated from the exhaled air using zeolite molecular sieve adsorbent at 77 K followed by a cold head at 8 K. Residual gaseous impurities are finally absorbed by a commercial nonevaporative getter. The recycled 3He gas features high purity, which is required for repolarization by metastability ex…

research product

Compression of Polarized 3He

This article gives a status report on the polarized 3He target development work at Mainz. It is based on the optical pumping of the 3S1 state of 3He with subsequent metastability spin exchange to the ground state atoms. This pumping scheme is very efficient at 3He pressures of about 1 Torr; for high density targets, however, a mechanical compression of the polarized gas is needed in a second step. First results with a Toepler compression pump look promising and will be discussed in the following.

research product

Ultraschnelle MRT der Lungenventilation mittels hochpolarisiertem Helium-3*

Objective Assessment of the temporal and spatial dynamics of hyperpolarized Helium-3 (3He) distribution in the lung with ultrafast gradient-echo magnetic-resonance imaging. Material and methods Coronal images of the lung were acquired using ultrafast gradient-echo pulse sequences with TR/TE = 3.3 ms/1.3 ms (slice thickness, 40 mm) and TR/TE = 2.0 ms/0.7 ms (without slice selection). A series of 80 or 160 projection images was obtained with 210 ms or 130 ms temporal resolution, respectively. Imaging was performed during several respiratory cycles after application of a single bolus of 300 mL hyperpolarized 3He. Measurements were performed in six healthy volunteers (spontaneous breathing). Re…

research product

Realization of a broad-band neutron spin filter with compressed, polarized 3He gas

The strongly spin-dependent absorption of neutrons in nuclear spin polarized 3He opens the possibility to polarize beams of thermal and epithermal neutrons. An effective 3He neutron spin filter (NSF) requires high 3He nuclear polarization as well as a filter thickness corresponding to amount of gas in the order of 1 bar 1. We realized such a filter using direct optical pumping of metastable 3He∗ atoms in a 3He plasma at 1 mb. Metastable exchange scattering transfers the angular momentum to the whole ensemble of 3He atoms. At present 3.6 × 1018 3He-atoms s−1 are polarized up to 68%. Subsequent polarization preserving compression by a two-stage compressor system enables to prepare NSF cells o…

research product

Normal and abnormal pulmonary ventilation: visualization at hyperpolarized He-3 MR imaging.

To assess the feasibility of helium-3 magnetic resonance (MR) imaging with a three-dimensional fast low-angle shot (FLASH) sequence, He-3 gas (volume, 300 mL; pressure, 3 x 10(5) Pa; polarized up to 45% by means of optimal pumping) was inhaled by five healthy volunteers and five patients with pulmonary diseases. All breath-hold examinations (22-42 seconds) were completed successfully. Normal ventilation was depicted with homogeneous high signal intensity, lesions were depicted as causing defects, and obstructive lung disease was depicted with severely inhomogeneous signal intensity.

research product

The Electric Formfactor of the Neutron Determined by Quasielastic Scattering of Longitudinally Polarized Electrons from 3He and 2D

The recent availability of polarized electron beams at electron accelerator laboratories adds another technique to probing the electromagnetic structure of nuclear matter [1]. The present paper discusses the application of polarized electron scattering to the determination of the electric formfactor of the neutron. Its value at medium energies is only poorly known hitherto. Electron scattering is dominated by interaction with the neutron magnetic moment. Therefore the contribution of the charge distribution to the scattering cross section is scarcely detectable in case of unpolarized collision partners. The elastic scattering of longitudinally polarized electrons from a polarized neutron ta…

research product

Nuclear magnetic resonance imaging with hyperpolarised helium-3

Abstract Summary Background Magnetic resonance imaging (MRI) relies on magnetisation of hydrogen nuclei (protons) of water molecules in tissue as source of the signal. This technique has been valuable for studying tissues that contain significant amounts of water, but biological settings with low proton content, notably the lungs, are difficult to image. We report use of spin-polarised helium-3 for lung MRI. Methods A volunteer inhaled hyperpolarised 3 He to fill the lungs, which were imaged with a conventional MRI detector assembly. The nuclear spin polarisation of helium, and other noble gases, can be greatly enhanced by laser optical pumping and is about 10 5 times larger than the polari…

research product

3He MRI in healthy volunteers: preliminary correlation with smoking history and lung volumes

MRI with hyperpolarized helium-3 (3He) provides high-resolution imaging of ventilated airspaces. The first aim of this 3He-study was to compare observations of localized signal defects in healthy smokers and non-smokers. A second aim was to describe relationships between parameters of lung function, volume of inspired 3He and signal-to-noise ratio. With Ethics Committee approval and informed consent, 12 healthy volunteers (seven smokers and five non-smokers) were studied. Imaging was performed in a 1.5 T scanner using a two-dimensional FLASH sequence at 30V transmitter amplitude (TR/TE/α = 11 ms/4.2 ms/<10°). Known amounts of 3He were inhaled from a microprocessor-controlled delivery device…

research product

Analysis of intrapulmonary O2concentration by MR imaging of inhaled hyperpolarized helium-3

Inhalation of hyperpolarized 3He allows magnetic resonance imaging (MRI) of ventilated airspaces.3He hyperpolarization decays more rapidly when interacting with paramagnetic O2. We describe a method for in vivo determination of intrapulmonary O2 concentrations ([O2]) based on MRI analysis of the fate of measured amounts of inhaled hyperpolarized3He in imaged regions of the lung. Anesthetized pigs underwent controlled normoventilation in a 1.5-T MRI unit. The inspired O2 fraction was varied to achieve different end-tidal [O2] fractions ([Formula: see text]). With the use of a specifically designed applicator,3He (100 ml, 35–45% polarized) was administered at a predefined time within single …

research product

First measurement of the electric formfactor of the neutron in the exclusive quasielastic scattering of polarized electrons from polarized 3He

Abstract A first measurement of the asymmetry in quasielastic scattering of longitudinally polarized electrons from a polarized 3 He gas target in coincidence with the knocked out neutron is reported. This measurement was made feasible by the cw beam of the 855 MeV Mainz Microtron MAMI. It allows a determination of the electric formfactor of the neutron G E n independent of binding effects to first order. At Q 2 =0.31 ( GeV /c) 2 two asymmetries A ∥ ( S He ∥ q ) and A ⊥ ( S He ⊥ q ) have been measured giving A ∥ =(−7.40±0.73)% and A ⊥ =(0.89±0.30)% . The ratio A ⊥ / A ∥ is independent of the absolute value of the electron and target polarization and yields G E n =0.035±0.012±0.005.

research product

Determination of the neutron electric form factor from the reaction 3 He(e,e'n) at medium momentum transfer

The electric form factor of the neutron GEn has been determined in double polarized exclusive 3He(e,e'n) scattering in quasi–elastic kinematics by measuring asymmetries A⊥, A∥ of the cross section with respect to helicity reversal of the electron, with the nuclear spin being oriented perpendicular to the momentum transfer q in case of A⊥ and parallel in case of A∥. The experiment was performed at the 855 MeV c. w. microtron MAMI at Mainz. The degree of polarization of the electron beam and of the gaseous 3He target were each about 50%. Scattered electrons and neutrons were detected in coincidence by detector arrays covering large solid angles. Quasi–elastic scattering events were reconstruc…

research product

Assessment of a single-acquisition imaging sequence for oxygen-sensitive (3)He-MRI.

MRI of the lungs using hyperpolarized helium-3 (3He) allows the determination of intrapulmonary oxygen partial pressures (pO2). The need to separate competing processes of signal loss has hitherto required two different imaging series during two different breathing maneuvers. In this work, a new imaging strategy to measure pO2 by a single series of consecutive scans is presented. The feasibility of the method is demonstrated in three healthy human volunteers. Maps and histograms of intrapulmonary pO2 are calculated. Changes in the oxygen concentration of the inhaled gas mixture are well reproduced in the histograms. Monte Carlo (MC) simulations of the temporal evolution of 3He hyperpolariza…

research product