0000000000041370

AUTHOR

Jörg Schmiedeskamp

Magnetized boxes for housing polarized spins in homogeneous fields

Abstract We present novel types of permanently magnetized as well as current powered boxes built from soft-ferromagnetic materials. They provide shielded magnetic fields which are homogeneous within a large fraction of the enclosed volume, thus minimizing size, weight, and costs. For the permanently magnetized solutions, homogenization is achieved either by an optimized distribution of the permanent field sources or by jacketing the field with a soft-ferromagnetic cylindrical shell which is magnetized in parallel to the enclosed field. The latter principle may be applied up to fields of about 0.1 T. With fields of about 1 mT, such boxes are being used for shipping spin-polarized 3 He worldw…

research product

Controlling diffusion of 3He by buffer gases: a structural contrast agent in lung MRI.

Purpose: To study the influence of admixing inert buffer gases to laser-polarized 3 He in terms of resulting diffusion coefficients and the consequences for image contrast and resolution. Materials and Methods: The diffusion coefficient of 3 He was altered by admixing buffer gases of various molecular weights ( 4 He, N2, and SF6). The influence of the pulse sequence and the diffusion coefficient on the appearance of MRI of (laserpolarized) gases was analyzed by comparison of basic theoretical concepts with demonstrative experiments. Results: Excellent agreement between theoretical description and observed signal in simple gradient echoes was observed. A maximum signal gain can be predicted …

research product

Quantification of Regional Intrapulmonary Oxygen Partial Pressure Evolution during Apnea by 3He MRI

We present a new method to determine in vivo the temporal evolution of intrapulmonary oxygen concentrations by functional lung imaging with hyperpolarized (3)Helium ((3)He-->). Single-breath, single-bolus visualization of (3)He--> administered to the airspaces is used to analyze nuclear spin relaxation caused by the local oxygen partial pressure p(O(2))(t). We model the dynamics of hyperpolarization in the lung by rate equations. Based hereupon, a double acquisition technique is presented to separate depolarization by RF pulses and oxygen induced relaxation. It permits the determination of p(O(2)) with a high accuracy of up to 3% with simultaneous flip angle calibration using no additional …

research product

Ein Auswerteprogramm zur quantitativen Untersuchung der Lungenventilation mittels dynamischer MRT von hochpolarisiertem 3He

Purpose: 3 He-MRI is able to visualize the regional distribution of lung ventilation with a temporal and spatial resolution so far unmatched by any other technique. The aim of the study was the development of a new software tool for quantification of dynamic ventilation parameters in absolute physical units. Materials and Methods: During continuous breathing, a bolus of hyperpolarized 3 He (300 ml) was applied at inspiration and a series of 168 coronal projection images simultaneously acquired using a 2D FLASH-sequence. Postprocessing software was developed to analyze the 3 He distribution in the lung. After correction for lung motion, several ventilation parameters (rise time, delay time, …

research product

Magnetic resonance imaging of dissolved hyperpolarized 129Xe using a membrane-based continuous flow system.

Abstract A technique for continuous production of solutions containing hyperpolarized 129Xe is explored for MRI applications. The method is based on hollow fiber membranes which inhibit the formation of foams and bubbles. A systematic analysis of various carrier agents for hyperpolarized 129Xe has been carried out, which are applicable as contrast agents for in vivo MRI. The image quality of different hyperpolarized Xe solutions is compared and MRI results obtained in a clinical as well as in a nonclinical MRI setting are provided. Moreover, we demonstrate the application of 129Xe contrast agents produced with our dissolution method for lung MRI by imaging hyperpolarized 129Xe that has been…

research product

Intrapulmonary 3He Gas Distribution Depending on Bolus Size and Temporal Bolus Placement

OBJECTIVE: Dynamic ventilation (3)He-MRI is a new method to assess pulmonary gas inflow. As differing airway diameters throughout the ventilatory cycle can influence gas inflow this study intends to investigate the influence of volume and timing of a He gas bolus with respect to the beginning of the tidal volume on inspiratory gas distribution. MATERIALS AND METHODS: An ultrafast 2-dimensional spoiled gradient echo sequence (temporal resolution 100 milliseconds) was used for dynamic ventilation (3)He-MRI of 11 anesthetized and mechanically ventilated pigs. The applied (3)He gas bolus was varied in volume between 100 and 200 mL. A 150-mL bolus was varied in its application time after the beg…

research product

Reformatierungen als Lösungsansatz für die Problematik der unterschiedlichen Schichtführung beim Vergleich von3He-MRT und HR-CT der Lunge

Purpose: 3 He-MRI of the lung has been shown to be a sensitive method for functional imaging of the lung. A previous study compared 3 He-MRI (coronal planes) with CT (transverse planes) by looking for ventilation defects and their pathomorphologic correlation. Anatomic structures, such as lobar fissures and hilar vessels, were used for orientation, but the reliable assignment of ventilation defects to lung segments is problematic. The present work compares multiplanar reformations of 3 He-MRI and HR-CT, which were generated from planes determined by the respective method, and investigates their suitability as a solution of this problem. Materials and Methods: A total of 16 data sets taken f…

research product

Imaging of a mixture of hyperpolarized 3He and 129Xe.

Abstract With the use of hyperpolarized gases, a great number of experiments have been carried out in order to improve the diagnostics of the lung, both from a structural and a functional point of view. 3 He is best suited for structural studies, whereas 129 Xe gives more detailed information about the functionality of the lung because it enters the bloodstream. In this work, we propose the use of a gas mixture to perform consecutive analysis of lung structure and functionality upon the delivery of a single bolus of gas. We show images of a helium–xenon gas mixture in the presence of a small amount of liquid toluene in order to demonstrate how both nuclei can be detected independently, extr…

research product

MR imaging of the lungs with hyperpolarized helium-3 gas transported by air.

Hyperpolarized noble gas MRI shows promise in the functional imaging of the pulmonary air spaces. The production of hyperpolarized (HP) gas requires specialized laser optical pumping apparatus, which is not likely to be home built in the majority of clinical MRI radiology centres. There are two routes through which HP gas will be made available to hospitals for clinical use: either the apparatus will be installed locally at a considerable expense to the centre, or a central facility will produce the gas and then deliver it to remote MRI sites as and when required. In this study, the feasibility of transporting large quantities of HP gas for in vivo MR imaging from a remote production facili…

research product

Ein Auswerteprogramm zur quantitativen Analyse von Messungen des alveolären Sauerstoffpartialdrucks (pAO2) mit der sauerstoffsensitiven 3He-MR-Tomographie

Purpose: To develop a software tool for quantitative analysis of alveolar oxygen partial pressure (p A O 2 ) as well as its time course during apnea. Material and Methods: T 1 -relaxation times of hyperpolarized 3 He are reduced by paramagnetic oxygen rendering 3 He-MRI sensitive to oxygen and thus allowing the assessment of the local oxygen partial pressure in the pulmonary airspaces. Oxygen-related relaxation and loss of polarization by RF-excitation can be discriminated by acquiring two image series with varying interscan delay and/or flip angles. Software was developed to calculate the p A O 2 and the decay rate in user-defined regions of interest (ROIs) automatically. Moreover, paramet…

research product

He-3 spin filter for neutrons

The strongly spin-dependent absorption of neutrons in nuclear spin-polarized (3)He opens up the possibility of polarizing neutrons from reactors and spallation sources over the full kinematical range of cold, thermal and hot neutrons. This paper gives a report on the neutron spin filter (NSF) development program at Mainz. The polarization technique is based on direct optical pumping of metastable (3)He atoms combined with a polarization preserving mechanical compression of the gas up to a pressure of several bar, necessary to run a NSF. The concept of a remote type of operation using detachable NSF cells is presented which requires long nuclear spin relaxation times of order 100 hours. A sh…

research product

Assessment of lung microstructure with magnetic resonance imaging of hyperpolarized Helium-3

Magnetic resonance imaging of the apparent diffusion coefficient (ADC) of hyperpolarized Helium-3 is a new technique for probing pulmonary microstructure in vivo. The aim of this study was the assessment of potential sources of systematic errors of the ADC measurement. The influence of macroscopic motion was determined by measurements at two different delays after initiating the breath-hold, and before and after cardiac arrest. An intercentre comparison was performed in two age- and lung function-matched groups of lung-healthy volunteers at two research sites. Moreover, measurements of diffusion anisotropy were performed. We found no dependency of the ADC as a function of the delay after st…

research product

Final State Interaction Effects in 3He(e ,e'p)

Abstract Asymmetries in quasi-elastic 3 He ( e → , e ′ p ) have been measured at a momentum transfer of 0.67 (GeV/ c ) 2 and are compared to a calculation which takes into account relativistic kinematics in the final state and a relativistic one-body current operator. With an exact solution of the Faddeev equation for the 3 He -ground state and an approximate treatment of final state interactions in the continuum good agreement is found with the experimental data.

research product

Magnetization of3He spin filter cells

A number of valved quartz glass 3He spin filter cells have been repeatedly exposed to various external magnetic fields in order to determine the influence of induced wall magnetization on the relaxation time in the cells. The procedures of magnetizing and degaussing of cells are described. A comparison of T1 measurements performed in the same cell by different methods attest the good reliability of the measurements as well as the time stability of T1 in Cs-coated quartz glass cells. No orientation dependence of the relaxation in fields of 8 G was observed. A strong dependence of T1 on the strengths of external magnetic fields, applied perpendicular to the direction of the guide field used d…

research product

Functional Analysis in Single-Lung Transplant Recipients

Objective To develop and evaluate a postprocessing tool to quantify ventilated split-lung volumes on the basis of 3 He-MRI and to apply it in patients after single-lung transplantation (SLTX). High-resolution CT (HRCT) was employed as a reference modality providing split air-filled lung volumes. Lung volumes derived from pulmonary function test results served as clinical parameters and were used as the “gold standard.” Material and methods Eight patients (mean age, 54 years) with emphysema and six patients (mean age, 58 years) with idiopathic pulmonary fibrosis. All patients were evaluated following SLTX. HRCT was performed during inspiration (slice thickness, 1 mm; increment, 10 mm). For c…

research product

Diffusion-weighted MRI of the lung with hyperpolarized helium-3: A study of reproducibility

Purpose To determine the reproducibility of several parameters of the ADC measurement by calculating the scan-to-scan intrasubject variability. Materials and Methods Measurements were performed using a gradient-echo sequence with a bipolar gradient for diffusion weighting (b = 3.89 sec/cm2). Five patients with pulmonary emphysema, and six healthy-lung volunteers were included in the study. Images were acquired after inspiration of 3He during a single inspiratory breath-hold. To assess the reproducibility, the measurement was performed twice (time between measurements = 20 minutes) without repositioning the subjects. Analysis was performed on the basis of region-of-interest (ROI) analysis an…

research product

Assessment of a single-acquisition imaging sequence for oxygen-sensitive (3)He-MRI.

MRI of the lungs using hyperpolarized helium-3 (3He) allows the determination of intrapulmonary oxygen partial pressures (pO2). The need to separate competing processes of signal loss has hitherto required two different imaging series during two different breathing maneuvers. In this work, a new imaging strategy to measure pO2 by a single series of consecutive scans is presented. The feasibility of the method is demonstrated in three healthy human volunteers. Maps and histograms of intrapulmonary pO2 are calculated. Changes in the oxygen concentration of the inhaled gas mixture are well reproduced in the histograms. Monte Carlo (MC) simulations of the temporal evolution of 3He hyperpolariza…

research product

Mikrostruktur der Lunge: Untersuchung mittels Diffusionsmessung von hochpolarisiertem 3Helium

Imaging methods to study the lung are traditionally based on x-ray or on radioactive contrast agents. Conventional magnetic resonance imaging (MRI) has only limited applications for lung imaging because of the low tissue density of protons concentration of hydrogen atoms, which are usually the basis for the imaging. The introduction of hyperpolarized noble gases as a contrast agent in MRI has opened new possibilities for lung diagnosis. The present paper describes this new technique. Diffusion-weighted MRI for assessment of the lung microstructure is presented here as an example of the new possibilities of functional imaging. Studies to determine the sensitivity of the diffusion measurement…

research product