0000000000043408

AUTHOR

Filippo Cademartiri

0000-0002-0579-3279

Prevalence and characteristics of coronary artery disease in a population with suspected ischaemic heart disease using CT coronary angiography: correlations with cardiovascular risk factors and clinical presentation

Purpose. This study was undertaken to describe the correlation between the distribution of coronary artery disease (CAD) in a symptomatic population with suspected ischaemic heart disease, cardiovascular risk factors (RF) and clinical presentation. Materials and methods. We studied 163 patients (mean age 65.5 years; 101 men and 62 women) referred for multidetector computed tomography coronary angiography (MDCT-CA) to rule out CAD. The patients had no prior history of revascularisation or myocardial infarction. We analysed how the characteristics of CAD (severity and type of plaque) can change with the increase in RF and how they are related to different clinical presentations. Results. Pati…

research product

Benign focal liver lesions: spectrum of findings on SonoVue-enhanced pulse-inversion ultrasonography.

The prevalence of benign focal liver lesions (BFLL) is high both in the general population and in patients with known malignancies. The gray-scale ultrasound (US) technique is usually the first-line imaging modality used in the radiological workup of such lesions, but unfortunately it lacks specificity. Furthermore, Doppler examination may often be unsatisfactory owing to motion artefacts, or when small or deeply located lesions are evaluated. Recently, microbubble-based contrast agents used in combination with gray-scale US techniques, which are very sensitive to nonlinear behavior of microbubbles, have led to a better depiction of both microvasculature and macrovasculature of focal hepati…

research product

Validity of epicardial fat volume as biomarker of coronary artery disease in symptomatic individuals: Results from the ALTER-BIO registry

Abstract Background To determine if an increased epicardial fat volume (EFV) is associated with coronary artery disease (CAD) in individuals with symptoms of cardiovascular (CV) disease. Methods Coronary Computed Tomographic Angiography (CCTA), demographic and clinical variables of 1344 individuals were retrieved: semi-automated measurements for EFV and coronary artery calcifications (CAC) were obtained. Individuals were grouped into three categories according to the presence of CAD, resulting in absent (CAD0), non-obstructive (CAD1) or obstructive (CAD2) disease-groups. Relation of EFV with CAD was assessed with two approaches: 1) presence of any CAD; 2) each individual CAD category. Resul…

research product

Liver haemangiomas undetermined at grey-scale ultrasound: contrast-enhancement patterns with SonoVue and pulse-inversion US.

The objective of this study was to describe the spectrum of contrast-enhancement patterns of hepatic haemangiomas undetermined at grey-scale ultrasound (US) on SonoVue-enhanced pulse-inversion (PI) US. Twenty patients (11 women, nine men) with 35 haemangiomas (size range: 1-7 cm; mean: 3.1 cm) undetermined at baseline US underwent PI at low M.I. (0.05-0.08) after i.v. injection of SonoVue. All haemangiomas were confirmed by typical helical computed tomography (CT) and/or magnetic resonance imaging (MRI) findings. US examinations were videotaped and then reviewed by two experienced radiologists blinded to the final diagnosis. Readers evaluated by consensus the baseline echogenicity and the d…

research product

Rationale, design and methods of CTCA-PRORECAD (Computed Tomography Coronary Angiography Prognostic Registry for Coronary Artery Disease): a multicentre and multivendor registry.

PURPOSE: This study was done to assess the prognostic value of computed tomography coronary angiography (CTCA) in a large multicentre population of patients with suspected coronary artery disease (CAD) and, in particular, its incremental value compared with traditional methods for risk stratification. MATERIALS AND METHODS: This is a retrospective observational study that began in January 2003 conducted on patients with suspected CAD assessed with CTCA on the basis of symptoms (chest pain, dyspnoea) and/or abnormal or equivocal stress test and/or a high cardiovascular risk profile. The participating centres will provide data obtained with CTCA performed with 16-slice or higher equipment. Ex…

research product

Diagnostic accuracy of 64-slice computed tomography coronary angiography in patients with low-to-intermediate risk

Purpose. Our aim was to evaluate the diagnostic accuracy of 64- slice computed tomography coronary angiography (MSCT-CA) for detecting significant stenosis (≥50% lumen reduction) in a population of patients at low to intermediate risk. Materials and methods. We studied 72 patients (38 men, 34 women, mean age 53.9±8.0 years) with atypical or typical chest pain and stratified in the low- to intermediate risk category. MSCT-CA (Sensation 64 Cardiac, Siemens, Germany) was performed after IV administration of 100 ml of iodinated contrast material (Iomeprol 400 mgI/ml, Bracco, Italy). Two observers, blinded to the results of conventional coronary angiography (CAG), assessed the MSCT-CA scans in c…

research product

Influence of image reconstruction parameters on cardiovascular risk reclassification by Computed Tomography Coronary Artery Calcium Score

Objective: To investigate the influence of different CT reconstruction parameters on coronary artery calcium scoring (CACS) values and reclassification of predicted cardiovascular (CV) risk. Methods: CACS was evaluated in 113 patients undergoing ECG-gated 64-slice CT. Reference CACS protocol included standard kernel filter (B35f) with slice thickness/increment of 3/1.5 mm, and field-of-view (FOV) of 150–180 mm. Influence of different image reconstruction algorithms (reconstructed slice thickness/increment 2.0/1.0–1.5/0.8–3.0/2.0–3.0/3.0 mm; slice kernel B30f-B45f; FOV 200–250 mm) on Agatston score was assessed by Bland-Altman plots and concordance correlation coefficient (CCC) ana…

research product

Quantification of epicardial fat with cardiac CT angiography and association with cardiovascular risk factors in symptomatic patients: From the ALTER-BIO (alternative cardiovascular bio-imaging markers) registry

PURPOSE We aimed to assess the association between features of epicardial adipose tissue and demographic, morphometric and clinical data, in a large population of symptomatic patients with clinical indication to cardiac computed tomography (CT) angiography. METHODS Epicardial fat volume (EFV) and adipose CT density of 1379 patients undergoing cardiac CT angiography (918 men, 66.6%; age range, 18–93 years; median age, 64 years) were semi-automatically quantified. Clinical variables were compared between diabetic and nondiabetic patients to assess potential differences in EFV and adipose CT density. Multiple regression models were calculated to find the clinical variables with a significant a…

research product

Carotid intima media thickness and coronary atherosclerosis linkage in symptomatic intermediate risk patients evaluated by coronary computed tomography angiography.

Background: There is a growing evidence that carotid intima media thickness (CIMT) is associated with coronary artery disease (CAD) and it should be used as a predictor of atherosclerotic burden of coronary arteries. However, these studies have been performed by using invasive coronary angiography (ICA) and in high-risk patients for CAD. The purpose of this study was to evaluate the correlation between CIMT by ultrasound and coronary atherosclerosis in symptomatic intermediate risk patients by coronary computed tomography angiography (CCTA). Methods: We enrolled 204 consecutive symptomatic patients (mean age: 61 +/- 10; men: 118) and intermediate risk for CAD. All patients underwent CIMT ul…

research product

Quantification of epicardial adipose tissue in coronary calcium score and CT coronary angiography image data sets: comparison of attenuation values, thickness and volumes

The aim of the study was to compare epicardial adipose tissue (EAT) characteristics assessed with coronary calcium score (CS) and CT coronary angiography (CTCA) image data sets.In 76 patients (mean age 59 ± 13 years) who underwent CS and CTCA owing to suspected coronary artery disease (CAD), EAT was quantified in terms of density (Hounsfield units), thickness and volume. The EAT volume was extracted with a semi-automatic software.A moderate correlation was found between EAT density in CS and CTCA image data sets (-100 ± 19 HU vs -70 ± 24 HU; p  0.05, r = 0.55). The distribution of EAT was not symmetrical with a maximal thickness at the right atrioventricular groove (14.2 ± 5.3 mm in CS, 15.…

research product

Appropriateness criteria for the use of cardiac computed tomography, SIC-SIRM part 2: Acute chest pain evaluation; Stent and coronary artery bypass graft patency evaluation; Planning of coronary revascularization and transcatheter valve procedures; Cardiomyopathies, electrophysiological applications, cardiac masses, cardio-oncology and pericardial diseases evaluation

In the past 20 years, cardiac computed tomography (CCT) has become a pivotal technique for the noninvasive diagnostic workup of coronary and cardiac diseases. Continuous technical and methodological improvements, combined with fast growing scientific evidence, have progressively expanded the clinical role of CCT. Randomized clinical trials documented the value of CCT in increasing the cost-effectiveness of the management of patients with acute chest pain presenting in the emergency department, also during the pandemic. Beyond the evaluation of stents and surgical graft patency, the anatomical and functional coronary imaging have the potential to guide treatment decision-making and planning …

research product

Introduction to coronary imaging with 64-slice computed tomography

The aim of this article is to illustrate the main technical improvements in the last generation of 64-row CT scanners and the possible applications in coronary angiography. In particular, we describe the new physical components (X-ray tube-detectors system) and the general scan and reconstruction parameters. We then define the scan protocols for coronary angiography with the new generation of 64-row CT scanners to enable radiologists to perform a CT study on the basis of the diagnostic possibilities.

research product

Coronary plaque imaging with multislice computed tomography: technique and clinical applications.

The composition of an atherosclerotic lesion, rather than solely the degree of stenosis, is considered to be an important determinant of acute coronary events. Whereas until recently only invasive techniques have been able to provide clues about plaque composition with consistent reproducibility, several recent studies have revealed the potential of multislice computed tomography (MSCT) for noninvasive plaque imaging. Coronary MSCT has the potential to detect coronary plaques and to characterize their composition based on the X-ray attenuating features of each structure. MSCT may also reveal the total plaque burden (calcified and noncalcified components) for individual patients with coronar…

research product

SIRM–SIC appropriateness criteria for the use of Cardiac Computed Tomography. Part 1: Congenital heart diseases, primary prevention, risk assessment before surgery, suspected CAD in symptomatic patients, plaque and epicardial adipose tissue characterization, and functional assessment of stenosis

AbstractIn the past 20 years, Cardiac Computed Tomography (CCT) has become a pivotal technique for the noninvasive diagnostic work-up of coronary and cardiac diseases. Continuous technical and methodological improvements, combined with fast growing scientific evidence, have progressively expanded the clinical role of CCT. Recent large multicenter randomized clinical trials documented the high prognostic value of CCT and its capability to increase the cost-effectiveness of the management of patients with suspected CAD. In the meantime, CCT, initially perceived as a simple non-invasive technique for studying coronary anatomy, has transformed into a multiparametric “one-stop-shop” approach abl…

research product

Integrated non-invasive approach to atherosclerosis with cardiac CT and carotid ultrasound in patients with suspected coronary artery disease

The aim of the study was to compare the atherosclerotic disease in the coronary and carotid arteries in patients who underwent non-invasive imaging for suspected stable coronary artery disease (CAD). 107 patients (64 men, age 59 ± 12) with atypical chest pain underwent cardiac CT (CCT) and carotid ultrasound (US) on the same day. Severity (obstructive or not-obstructive disease), location, shape, and composition of atherosclerotic plaques in the two districts were evaluated. Patients presented normal coronary arteries in 36 % (n = 38), not-obstructive CAD in 36 % (n = 39), and obstructive CAD in 28 % (n = 30), while had normal carotid arteries in 53 % (n = 57), not-obstructive disease in 44…

research product

Physiopathology of the aging heart

research product

Comprehensive cardiovascular ECG-gated MDCT as a standard diagnostic tool in patients with acute chest pain

Acute myocardial infarction, pulmonary embolism, and aortic dissection are diseases associated with acute chest pain and may lead to severe morbidity and mortality. These diseases may not be trivial to diagnose in the settings of emergency room. ECG-gated multi-detector computed tomography (MDCT), already established for the assessment of pulmonary embolism and aortic dissection, provides reliable information regarding the triage of patients with acute coronary syndrome in the emergency room. MDCT recently appeared to be logistically feasible and a promising comprehensive method for the evaluation of cardiac and non-cardiac chest pain in emergency department patients. The possibility to sca…

research product

Non-invasive visualisation of coronary atherosclerosis: state-of-art.

Coronary artery disease remains the leading cause of death in the Western world. Non-invasive coronary artery imaging challenges any diagnostic modality because the coronary arteries are small and tortuous, whereas cardiac contraction and respiration cause motion artifacts. Therefore, non-invasive coronary imaging requires high spatial and temporal resolution. This review discusses the feasible applications in coronary imaging of magnetic resonance imaging and multi-slice computed tomography (MSCT), which are currently the only non-invasive diagnostic modalities for direct coronary atherosclerosis imaging. Particular attention and focus is devoted to the potential indications and clinical i…

research product

Stercorary aseptic peritonitis due to diastatic caecal perforation: Computed tomography findings

Caecal perforation is a complication secondary to colon obstruction. It may present with insidious clinical features and may be associated with chronic constipation. The event may become severe due to the peritonitic development. We present a case of caecal perforation associated with sub-occlusive carcinoma of the left colon and hypotonic colitis caused by chronic lavative abuse, demonstrated with Computed Tomography.

research product

Diagnostic accuracy of 64-slice CT in the assessment of coronary stents

PURPOSE: The purpose of this study was to assess the diagnostic accuracy of 64-slice computed tomography (64-CT) coronary angiography in the detection of coronary in-stent restenosis. MATERIALS AND METHODS: Ninety-five patients (72 men and 23 women, mean age 58+/-8 years) with previous percutaneous coronary intervention with stenting and suspected restenosis underwent 64-CT (Sensation 64, Siemens). The mean time between stent deployment and 64-CT was 6.1+/-4.2 months. The scan parameters were: slices 32 x 2, individual detector width 0.6 mm, rotation time 0.33 s, feed 3.84 mm/rotation, 120 kV, 900 mAs. After the intravenous administration of iodinated contrast material (Iomeprol 400 mgI/ml,…

research product

Computed tomography coronary angiography in asymptomatic patients

This study assessed the accuracy of computed tomography coronary angiography (CT-CA) for detecting significant coronary artery disease (CAD; a parts per thousand yen50% lumen reduction) in intermediate/high-risk asymptomatic patients. A total of 183 consecutive asymptomatic individuals (92 men; mean age 54 +/- 11 years) with more than one major risk factor (obesity, hypertension, diabetes, hypercholesterolaemia, family history, smoking) and an inconclusive or nonfeasible noninvasive stress test result (stress electrocardiography, stress echocardiography, nuclear stress scintigraphy) underwent CT-CA in an outpatient setting. All patients underwent conventional coronary angiography (CAG) with…

research product

Incremental value and safety of oral ivabradine for heart rate reduction in computed tomography coronary angiography

Background: Heart rate (HR) reduction is essential to achieve optimal image quality and diagnostic accuracy with computed tomography coronary angiography (CTCA). Administration of ivabradine could be an attractive alternative to beta-blockade to reduce HR. Methods: One-hundred-twenty-three patients referred for CTCA were prospectively enrolled. Patients were divided in two groups depending on the absence or presence of chronic beta-blockade treatment. Within the two groups patients were randomized to either no additional premedication or oral ivabradine for 5 days prior to CTCA. In presence of chronic beta-blockade therapy it was shifted to atenolol 50 mg twice a day for 5 days prior to CTC…

research product

Prevalence of coronary artery intramyocardial course in a large population of clinical patients detected by multislice computed tomography coronary angiography

Background: Intramyocardial course, an inborn coronary anomaly, is defined as a segment of a major epicardial coronary artery that runs intramurally through the myocardium; in particular, we distinguish myocardial bridging, in which the vessel returns to an epicardial position after the muscle bridge, and intramyocardial course, which is described as a vessel running and ending in the myocardium. Purpose: To evaluate the prevalence of myocardial bridging and intramyocardial course of coronary arteries as defined by multidetector computed tomography (MDCT) angiography. Material and Methods: The study population consisted of 242 consecutive patients (211 men, 31 women; mean age 59±6 years) w…

research product

Imaging techniques for the vulnerable coronary plaque

The goal of this article is to illustrate the main invasive and noninvasive diagnostic modalities to image the vulnerable coronary plaque, which is responsible for acute coronary syndrome. The main epidemiologic and histological issues are briefly discussed in order to provide an adequate background. Comprehensive coronary atherosclerosis imaging should involve visualization of the entire coronary artery tree and plaque characterization, including three-dimensional morphology, relationship with the lumen, composition, vascular remodelling and presence of inflammation. No single technique provides such a comprehensive description, and no available modality extensively identifies the vulnerab…

research product

Cardiac Magnetic Resonance with Delayed Enhancement of the Right Ventricle in patients with Left Ventricle primary involvement: diagnosis and evaluation of functional parameters.

: Cardiac Magnetic Resonance (CMR) allows an accurate Right Ventricle (RV) assessment that could be of great relevance in diseases causing inflammation or fibrosis. The aim of this study was to evaluate the concomitant involvement of the RV in patients with delayed enhancement (DE) of the Left Ventricle (LV-DE) using CMR. We retrospectively enrolled 95 (male n. 66; age 55±18years; BMI 26±5kg/m2) consecutive patients with LV-DE who underwent a CMR (Achieva 1.5 T, Philips) for different indications: post-ischemic dilated cardiopathy (PDM), hypertrophic cardiomyopathy (HCM), myocardial infarction (MI), myocarditis/pericarditis (MP) and congenital heart disease (CD). We assessed the presence an…

research product

Parameters for coronary plaque vulnerability assessed with multidetector computed tomography and intracoronary ultrasound correlation

In the absence of a fixed relationship between plaque vulnerability and flow-limiting stenosis, alternative morphological expressions exist that could predict the liability of coronary lesions to rapidly progress or rupture, causing acute coronary syndromes. Modern multidetector computed tomography technology is capable of noninvasively detecting lesion location, attenuation, remodeling and calcification pattern, which may be considered as surrogate morphological markers of vulnerability and could contribute to increase the prognostic value of individual coronary plaque burden. J Cardiovasc Med 10:821 -826 (C) 2009 Italian Federation of Cardiology.

research product

Noninvasive evaluation of the celiac trunk and superior mesenteric artery with multislice CT in patients with chronic mesenteric ischaemia.

This study sought to assess the role of multislice computed tomography (MSCT) in patients with suspected chronic mesenteric ischaemia (CMI). Forty-five patients (29 men; mean age 68) underwent MSCT angiography of the abdomen for suspected CMI (main clinical finding: postprandial abdominal pain). The scan protocol was detectors/collimation 16/0.75 mm; feed 36 mm/s; rotation time 500 ms; increment 0.4 mm; 120-150 mAs and 120 kVp. A volume of 80 ml of contrast material was administered through an antecubital vein (rate 4 ml/s), followed by 40 ml of saline (rate 4 ml/s). Images were analysed on the workstation with different algorithms (axial image scrolling, multiplanar reconstructions, maximu…

research product

Can ECG-gated MDCT be considered an obligatory step to plan and manage a new chest-pain unit?

The recent improvements in multi-detector computed tomography technology and its application in cardiac field allow to consider this non-invasive imaging technique as a promising comprehensive method for detecting significant coronary stenoses in a chest-pain unit. The possibility to use the ECG-synchronisation acquisition protocol, normally limited to the cardiac volume, for the entire thoracic vascular system should have the remarkable potential to reduce invasive and non-invasive procedures actually used to investigate acute chest pain and the number of unnecessary hospital admissions without reducing appropriate admissions in patients with chest pain.

research product

3D reconstruction techniques made easy: know-how and pictures

Three-dimensional reconstructions represent a visual-based tool for illustrating the basis of three-dimensional post-processing such as interpolation, ray-casting, segmentation, percentage classification, gradient calculation, shading and illumination. The knowledge of the optimal scanning and reconstruction parameters facilitates the use of three-dimensional reconstruction techniques in clinical practise. The aim of this article is to explain the principles of multidimensional image processing in a pictorial way and the advantages and limitations of the different possibilities of 3D visualisation.

research product

Collateral non cardiac findings in clinical routine CT coronary angiography: results from a multi-center registry.

Purpose: The aim of the study was to evaluate the prevalence of collateral findings detected in computed tomography coronary angiography (CTCA) in a multi-center registry. Materials and methods: We performed a retrospective review of 4303 patients (2719 males, mean age 60.3 ± 10.2 years) undergoing 64-slice CTCA for suspected or known coronary artery disease (CAD) at various academic institutions between 01/2006 and 09/2010. Collateral findings were recorded and scored as: non-significant (no signs of relevant pathology, not necessary to be reported), significant (clear signs of pathology, mandatory to be reported), or major (remarkable pathology, mandatory to be reported and further invest…

research product

Myocardial blood flow quantification for evaluation of coronary artery disease by computed tomography

During the last decade coronary computed tomography angiography (CTA) has become the preeminent non-invasive imaging modality to detect coronary artery disease (CAD) with high accuracy. However, CTA has a limited value in assessing the hemodynamic significance of a given stenosis due to a modest specificity and positive predictive value. In recent years, different CT techniques for detecting myocardial ischemia have emerged, such as CT-derived fractional flow reserve (FFR-CT), transluminal attenuation gradient (TAG), and myocardial CT perfusion (CTP) imaging. Myocardial CTP imaging can be performed with a single static scan during first pass of the contrast agent, with monoenergetic or dual…

research product

Impact of coronary calcium score on diagnostic accuracy for the detection of significant coronary stenosis with multislice computed tomography angiography.

One hundred twenty patients in sinus rhythm with suspected coronary artery disease who underwent multislice computed tomography of the heart and conventional coronary angiography were retrospectively selected. The population was divided into 2 groups depending on their calcium score (CS) (e.g., low CS and high CS). The diagnostic accuracy of multislice computed tomographic scans for detecting significant lesions (>50% lumen reduction) in both groups was compared with quantitative coronary angiography. The sensitivity and specificity of multislice computed tomography were 90% and 92%, and 97% and 91% for low and high CS groups, respectively.

research product

Prevalence of anatomical variants and coronary anomalies in 543 consecutive patients studied with 64-slice CT coronary angiography

The aim of our study was to assess the prevalence of variants and anomalies of the coronary artery tree in patients who underwent 64-slice computed tomography coronary angiography (CT-CA) for suspected or known coronary artery disease. A total of 543 patients (389 male, mean age 60.5 +/- 10.9) were reviewed for coronary artery variants and anomalies including post-processing tools. The majority of segments were identified according to the American Heart Association scheme. The coronary dominance pattern results were: right, 86.6%; left, 9.2%; balanced, 4.2%. The left main coronary artery had a mean length of 112 +/- 55 mm. The intermediate branch was present in the 21.9%. A variable number …

research product

A semi-automatic approach for epicardial adipose tissue segmentation and quantification on cardiac CT scans

Abstract Many studies have shown that epicardial fat is associated with a higher risk of heart diseases. Accurate epicardial adipose tissue quantification is still an open research issue. Considering that manual approaches are generally user-dependent and time-consuming, computer-assisted tools can considerably improve the result repeatability as well as reduce the time required for performing an accurate segmentation. Unfortunately, fully automatic strategies might not always identify the Region of Interest (ROI) correctly. Moreover, they could require user interaction for handling unexpected events. This paper proposes a semi-automatic method for Epicardial Fat Volume (EFV) segmentation a…

research product

Non-invasive assessment of coronary artery stent patency with multislice CT: preliminary experience.

To evaluate the diagnostic accuracy of multislice computed tomography coronary angiography (MSCT-CA) in the detection of in-stent restenosis.Forty-two patients (33 male, 9 female, mean age 58+/-8 years) previously subjected to percutaneous implantation of coronary stent with suspected in-stent restenosis, underwent a 16-row MSCT (Sensation 16, Siemens) examination. The average time between stent implantation and MSCT-CA was 7.4+/-5.3 months. The following scan parameters were used: collimation 16x0.75 mm, rotation time 0.42 s, feed 3.0 mm/rot., kV 120, mAs 500. After administration of iodinated contrast material (Iomeprol 400 mgI/ml, 100 ml at 4 ml/s) and bolus chaser (40 ml of saline at 4 …

research product

Intravenous Contrast Material for Cardiac Computed Tomography

Purpose: The Italian Registry of Contrast Material use in Cardiac Computed Tomography (iRCM-CCT) is a multicenter, multivendor, observational study on the use of contrast media (CM) in patients undergoing cardiac computed tomography (CCT). The aim of iRCM-CCT is to assess image quality and safety profile of intravenous CM compounds. Materials and methods: iRCM-CCT enrolled 1842 consecutive patients undergoing CCT (≥50 per site) at 20 cluster sites with the indication of suspected coronary artery disease. Demographic characteristics, CCT, and CM protocols, clinical indications, safety markers, radiation dose reports, qualitative (ie, poor vascular enhancement) and quantitative (ie, HU attenu…

research product

ECG-GATED MULTIDETECTOR COMPUTED TOMOGRAPHY FOR THE ASSESSMENT OF THE POSTOPERATIVE ASCENDING AORTA

This study was undertaken to define the role of electrocardiographically (ECG)-gated multidetector computed tomography (MDCT) in the assessment of the postoperative ascending aorta. From November 2006 to June 2007, 21 patients, [11 men, ten women; age +/- standard deviation (SD): 62.7 +/- 10.8 years] with a history of ascending aorta replacement underwent ECG-gated MDCT and were prospectively included in our study. Ascending aorta replacement had been performed with different surgical techniques: Bentall-De Bono (four patients, 19%), Tirone-David (five patients, 23%), and modified Tirone-David with creation of aortic neosinuses (12 patients, 57%). Two patients were excluded from MDCT evalua…

research product

Computed tomography coronary angiography vs. stress ECG in patients with stable angina

PURPOSE: This study compared the role of multislice computed tomography coronary angiography (MSCT-CA) and stress electrocardiography (ECG) in the diagnostic workup of patients with chronic chest pain. MATERIALS AND METHODS: MSCT-CA was performed in 43 patients (31 men, 12 women, mean age 58.8+/-7.7 years) with stable angina after a routine diagnostic workup involving stress ECG and conventional CA. The following inclusion criteria were adopted: sinus rhythm and ability to hold breath for 12 s. Beta-blockers were administered in patients with heart rate>or=70 beats/minute. In order to identify or exclude patients with significant stenoses (>or=50% lumen), we determined posttest likelihood r…

research product

Angioplastica coronarica

research product

Heart anatomy

research product

Usefulness of multislice computed tomography to assess patency of coronary artery stents versus conventional coronary angiography

BACKGROUND: The aim of the present study was to assess the in-stent restenosis and occlusion of coronary artery stents by multislice computed tomography (MSCT) compared with conventional coronary angiography in patients with atypical chest pain and not practicable/non-conclusive stress test. METHODS: Between December 2004 and March 2006, 81 patients were scheduled and of these 72 (65 men, mean age 61 years) with 90 stents underwent MSCT angiography using a 16-slice scanner, Toshiba Aquilion 16, 8-12 months after stent placement. RESULTS: Of the 90 stents, 71 (79%) could be assessed and 19 (21%) were excluded because the image quality at the stent level was incompatible with diagnostic asses…

research product

Role of cardiac computed tomography in the evaluation of coronary artery stenosis in patients with ascending aorta aneurysm detected at transthoracic echocardiography

OBJECTIVE The aim of our study was to evaluate the diagnostic performance of cardiac computed tomography (CCT) in the evaluation of coronary artery stenosis in patients with ascending aorta aneurysm detected at transthoracic echocardiography. METHODS We conducted a retrospective analysis of patients with an aneurysm 45 mm or greater at transthoracic echocardiography who underwent CCT from 2012 to 2014 in our hospital. We calculated the sensitivity, specificity, and positive and negative predictive values of CCT for the assessment of coronary artery stenosis (<50% or ≥50% stenosis) in patients who underwent conventional coronary angiography. RESULTS We included 104 patients (73 men, aged 64 …

research product

Technical development in cardiac CT: current standards and future improvements—a narrative review

Non-invasive depiction of coronary arteries has been a great challenge for imaging specialists since the introduction of computed tomography (CT). Technological development together with improvements in spatial, temporal, and contrast resolution, progressively allowed implementation of the current clinical role of the CT assessment of coronary arteries. Several technological evolutions including hardware and software solutions of CT scanners have been developed to improve spatial and temporal resolution. The main challenges of cardiac computed tomography (CCT) are currently plaque characterization, functional assessment of stenosis and radiation dose reduction. In this review, we will discu…

research product

Spectrum of collateral findings in multislice CT coronary angiography.

Purpose. The aim of the study was to investigate the prevalence of the noncardiac collateral findings during multislice computed tomography coronary angiography (MSCT-CA). Materials and methods. Six hundred and seventy patients undergoing MSCT-CA with 16-slice and 64-slice CT scanners for suspected atherosclerotic disease of the coronary arteries were retrospectively reviewed. All data sets obtained with a large field of view (FOV) were analysed by two radiologists using standard mediastinal and lung window settings. Collateral findings were divided according to clinical importance into nonsignificant, remarkable and compulsory to be investigated. Results. Eighty-five percent of patients re…

research product

Clinical indications for the use of cardiac MRI. By the SIRM Study Group on Cardiac Imaging

Cardiac magnetic resonance (CMR) is considered an useful method in the evaluation of many cardiac disorders. Based on our experience and available literature, we wrote a document as a guiding tool in the clinical use of CMR. Synthetically we describe different cardiac disorders and express for each one a classification, I to IV, depending on the significance of diagnostic information expected.

research product

Clinical relevance of myocardial bridging detected by coronary CT angiography in patients with atypical chest pain

research product

Reproducible coronary plaque quantification by multislice computed tomography

BACKGROUND: The aim of this study was to investigate reproducibility and accuracy of computer-assisted coronary plaque measurements by multislice computed tomography coronary angiography (QMSCT-CA). METHODS AND RESULTS: Forty-eight patients undergoing MSCT-CA and coronary arteriography for symptomatic coronary artery disease and quantitative intravascular ultrasound (IVUS, QCU) were examined. Two investigators performed the QMSCT-CA twice and a third investigator performed the QCU, all blinded for each other's results. There was no difference found for the matched region of interest (ROI) lengths (QCU 29.4 +/- 13 mm vs. QMSCT-CA 29.6 +/- 13 mm, P = 0.6; total length = 1,400 mm). The compari…

research product

Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography

OBJECTIVE: The purpose of this study was to investigate whether the amount of intracoronary attenuation influences the diagnostic accuracy of MDCT coronary angiography in the detection of clinically significant stenosis. MATERIALS AND METHODS: One hundred twenty patients in sinus rhythm with suspected coronary artery disease who underwent MDCT of the heart and conventional coronary angiography were retrospectively selected. The population was divided into two groups depending on median (326 H) coronary vascular enhancement (i.e., low attenuation and high attenuation). The diagnostic accuracy of MDCT for the detection of clinically significant coronary artery lesions (> or = 50% lumen reduct…

research product

Assessment of left main coronary artery atherosclerotic burden using 64-slice CT coronary angiography: correlation between dimensions and presence of plaques.

PURPOSE: The aim of this study was to correlate left main (LM) coronary artery dimensions with the presence of atherosclerosis by multidetector-row computed tomography (MDCT) coronary angiography (CA) and to assess coronary atherosclerotic plaques with a semiquantitative method. MATERIALS AND METHODS: Sixty-two consecutive patients (41 men, mean age 60+/-11) with suspected coronary artery disease underwent 64-MDCT coronary angiography. LM dimensions (length, ostial and bifurcation diameters), quantitative [location, Hounsfield unit (HU) attenuation] and qualitative (composition, shape) analysis of plaques within the LM were performed. All patients underwent conventional CA. RESULTS: Thirty …

research product

CT coronary angiography at an ultra-low radiation dose (< 0.1 mSv): feasible and viable in times of constraint on healthcare costs

Computed tomography coronary angiography (CTCA) has reached very high standards both in terms of diagnostic performance and radiation dose reduction. This commentary follows a report on CTCA using less than 0.1 mSv in selected patients. This is an extraordinary accomplishment, both for technology and for medicine. The difficult task is now to implement this tool in clinical practice so it can play the best possible role. CTCA can improve diagnostic pathways, can save money for healthcare systems and could even improve pharmacological therapy. All of this may happen, but it will require the combined effort of all the experienced operators in this field, including the referring clinicians. In…

research product

Ischemic Heart Disease, CT

research product

Infarct characterization using CT

Myocardial infarction (MI) is a major cause of death and disability worldwide. The incidence is not expected to diminish, despite better prevention, diagnosis and treatment, because of the ageing population in industrialized countries and unhealthy lifestyles in developing countries. Nowadays it is highly requested an imaging tool able to evaluate MI and viability. Technology improvements determined an expansion of clinical indications from coronary plaque evaluation to functional applications (perfusion, ischemia and viability after MI) integrating additional phases and information in the mainstream examination. Cardiac computed tomography (CCT) and cardiac MR (CMR) employ different contra…

research product

Characterization of benign hepatic tumors arising in fatty liver with SonoVue and pulse inversion US.

Background: We describe the spectrum of contrast-enhancement patterns of benign hepatic tumors arising in fatty liver on contrast-enhanced ultrasound (US). Methods: Sixteen patients (12 women and four men) with 27 benign hepatic tumors (17 hemangiomas, eight focal nodular hyperplasias, and two hepatocellular adenomas) arising in fatty liver underwent baseline and pulse inversion US after administration of SonoVue. Two experienced radiologists evaluated baseline echogenicity and dynamic enhancement pattern of each lesion in comparison with adjacent liver parenchyma. Results: After administration of SonoVue, in the arterial phase 13 of 17 hemangiomas showed peripheral globular enhancement and…

research product

High Iodine Concentration Contrast Material for Noninvasive Multislice Computed Tomography Coronary Angiography

OBJECTIVE: The objective of this study was to compare intracoronary attenuation on 16-row multislice computed tomography (16-MSCT) coronary angiography using 2 contrast materials (CM) with high iodine concentration. MATERIAL AND METHODS: Forty consecutive patients (29 male, 11 female; mean age, 61 ± 11 years) with suspected coronary artery disease were randomized to 2 groups to receive 100 mL of either iopromide 370 (group 1: Ultravist 370, 370 mg iodine/mL; Schering AG, Berlin, Germany) or iomeprol 400 (group 2: Iomeron 400, 400 mg iodine/mL; Bracco Imaging SpA, Milan, Italy). Both CM were administered at a rate of 4 mL/s. All patients underwent 16-MSCT coronary angiography (Sensation 16; …

research product

Updated diagnosticprognostic paradigm for CAD: a narrative review.

Cardiovascular diseases are the first cause of death globally; early detection of coronary artery disease (CAD) is a challenge for clinicians and radiologists. Over the past 2 decades there have been several improvements in the methods for the assessment of diagnosis and prognosis in patients with suspected CAD; most of these methods are imaging methods and they operate with high-end technologies. Cardiac computed tomography (CCT) as we know it today was introduced in 1998 and has ever progressed with constant pace. The first decade was the technical validation phase of the method while the second decade was the clinical validation phase. CCT has developed an excellent diagnostic and progno…

research product

Prognostic value of Morise clinical score, calcium score and computed tomography coronary angiography in patients with suspected or known coronary artery disease

Our aim was to determine the prognostic value of computed tomography coronary angiography (CTCA), coronary artery calcium scoring (CACS) and Morise clinical score in patients with known or suspected coronary artery disease (CAD). A total of 722 patients (480 men; 62.7 +/- 10.9 years) who were referred for further cardiac evaluation underwent CACS and contrast-enhanced CTCA to evaluate the presence and severity of CAD. Of these, 511 (71%) patients were without previous history of CAD. Patients were stratified according to the Morise clinical score (low, intermediate, high), to CACS (0-10, 11-100, 101-400, 401-1,000, &gt; 1,000) and to CTCA (absence of CAD, nonsignificant CAD, obstructive CAD…

research product

A new automated method for quantitative computer tomography coronary angiography (QMSCTA): an in-vivo validation study with intracoronary ultrasound as reference

research product

Coronary CT angiography: a guide to examination, interpretation, and clinical indications

Introduction: The introduction of Cardiac Computed Tomography (CCT) has changed the paradigm in the field of diagnostic cardiovascular medicine. CCT is the primary tool in the assessment of suspected Coronary Artery Disease (CAD) and should be followed by functional assessment when needed to stratify disease and to plan potential interventional or surgical therapy. Areas Covered: We provided the current state of the knowledge on the main aspects of technique of examination, image interpretation and clinical indications. We have focused our attention on the basic routine applications and activities. Expert Opinion: The primary role of CCT in suspected CAD will progressively become the standa…

research product

Non-invasive evaluation of coronary calcium.

research product

Abdominal Computed Tomography Angiography at 80kV: feasibility study.

preliminary evaluation of different dose reduction algorithms in abdominal Computed Tomography Angiography (CTA) with standard scan protocols at 120kV vs. 80kV.prospective, randomized, crossover study. 60 consecutive patients who underwent CTA of the abdomen (Sensation 64, Siemens; Iomeprol 400 mgl/ml Bracco) for suspected or diagnosed Abdominal Aortic Aneurysm (AAA) were enrolled in the study. A standard 120kV/200mAs scan protocol was acquired in all patients (reference tube current modulated with Automatic Exposure Control). In each patient a second scan with 80kV/300mAs (Group 1; n. 20), 80kV/400mAs (Group 2; n. 20), 80kV/500mAs (Group 3; n. 20) was acquired. We used the same scan/recons…

research product

Right coronary artery arising from pulmonary trunk: assessment with conventional coronary angiography and multislice computed tomography coronary angiography.

We present a case of a 59-year-old man who was admitted to the hospital because of atypical chest pain and dyspnea. Conventional coronary angiography showed an anomalous origin of the right coronary artery from the pulmonary trunk. The patient underwent multislice computed tomography in order to clarify the origin and course of the anomalous vessel. The aim of this report is to emphasize the role of multislice computed tomography as an accurate noninvasive imaging tool in the evaluation of coronary artery anomalies.

research product

Physiopathology of the aging heart.

Coronary heart disease remains the leading cause of morbidity and mortality in older adults, despite improved survival and declining mortality. Prevalence in and impact of heart disease on elderly people, increasing risk factors, and the underlying physiologic changes of aging are briefly reviewed. High prevalence of clinical and subclinical heart disease provides a basis for considering opportunities for prevention and follow-up. This article focuses on recently developed noninvasive techniques, such as cardiac multislice CT and cardiac MR imaging.

research product

Lesions of Proximal Coronary Arteries

Coronary artery disease (CAD) remains the leading cause of death in the Western world. Conventional coronary angiography (CCA) is the gold standard method for evaluation of the vascular lumen and provides excellent results in demonstrating stenotic lesions of CAD. However, it is an invasive procedure with a small risk of fatal events. Furthermore, CCA is a lumen-oriented technique that does not permit a direct visualization and evaluation of the coronary artery wall. The characterization of coronary plaques without a significant lumen narrowing is also not feasible with CCA. This information is relevant since the comparison of angiographic studies of coronary arteries performed before and a…

research product

Technical analysis of volume-rendering algorithms: application in low-contrast structures using liver vascularisation as a model.

research product

Prognostic value of cardiac CT

In the past decades, coronary computed tomography angiography (CCTA) has become a powerful tool in the management of coronary artery disease. The diagnostic and prognostic value of CCTA has been extensively demonstrated in both large observational studies and clinical trials among stable chest pain patients. The quantification of coronary artery calcium score (CACS) is a well-established predictor of cardiovascular morbidity and mortality in asymptomatic subjects. Besides CACS, the main strength of CCTA is the accurate assessment of the individual total atherosclerotic plaque burden, which holds important prognostic information. In addition, CCTA, by providing detailed information on corona…

research product

Influence of convolution filtering on coronary plaque attenuation values: observations in an ex vivo model of multislice computed tomography coronary angiography.

Attenuation variability ( measured in Hounsfield Units, HU) of human coronary plaques using multislice computed tomography (MSCT) was evaluated in an ex vivo model with increasing convolution kernels. MSCT was performed in seven ex vivo left coronary arteries sunk into oil followingthe instillation of saline (1/infinity) and a 1/50 solution of contrast material ( 400 mgI/ml iomeprol). Scan parameters were: slices/ collimation, 16/0.75 mm; rotation time, 375 ms. Four convolution kernels were used: b30f-smooth, b36f-medium smooth, b46f-medium and b60f-sharp. An experienced radiologist scored for the presence of plaques and measured the attenuation in lumen, calcified and noncalcified plaques …

research product

Coronary calcium score and computed tomography coronary angiography in high-risk asymptomatic subjects: assessment of diagnostic accuracy and prevalence of non-obstructive coronary artery disease

The aim of the study was to compare the coronary artery calcium score (CACS) and computed tomography coronary angiography (CTCA) for the assessment of non-obstructive/obstructive coronary artery disease (CAD) in high-risk asymptomatic subjects. Two hundred and thirteen consecutive asymptomatic subjects (113 male; mean age 53.6 +/- 12.4 years) with more than one risk factor and an inconclusive or unfeasible non-invasive stress test result underwent CACS and CTCA in an outpatient setting. All patients underwent conventional coronary angiography (CAG). Data from CACS (threshold for positive image: Agatston score 1/100/1,000) and CTCA were compared with CAG regarding the degree of CAD (non-obst…

research product

Low dose CT of the heart: a quantum leap into a new era of cardiovascular imaging.

In 10 years, computed tomography coronary angiography (CTCA) has shifted from an investigational tool to clinical reality. Even though CT technologies are very advanced and widely available, a large body of evidence supporting the clinical role of CTCA is missing. The reason is that the speed of technological development has outpaced the ability of the scientific community to demonstrate the clinical utility of the technique. In addition, with each new CT generation, there is a further broadening of actual and potential applications. In this review we examine the state of the art on CTCA. In particular, we focus on issues concerning technological development, radiation dose, implementation,…

research product

Evaluation of Cardiac Volumetric and Functional Parameters

The milestone definition of “Cardiac Function” has to be attributed to William Harvey, the discoverer of the circulation, who in 1628 stated: “The movement of the blood is constantly in a circle, and is brought about by the beat of the heart” [1, 2]. From a modern point of view, the main function of the heart is the delivery of oxygen to metabolizing tissues. Since oxygen delivery is dependent on (1) the oxygen-carrying capacity of blood, (2) the flow output from the heart, and (3) regional distribution of flow, then the heart is nowadays regarded as a pump with the function of supplying flow in blood vessels [2].

research product

Heart rate control with oral ivabradine in computed tomography coronary angiography: a randomized comparison of 7.5 mg vs 5 mg regimen.

Background: Heart rate (HR) reduction is essential to achieve optimal image quality and diagnostic accuracy with computed tomography coronary angiography (CTCA). Administration of oral ivabradine seems to be more effective than beta-blockade in reducing HR in patients referred for CTCA. Methods: Two-hundred-fifty-nine consecutive patients referred for CTCA were prospectively enrolled. Patients not receiving beta-blocker at baseline (group 1) and those with beta-blocker therapy (group 2) were enrolled in the study. Each group was randomized into 3 parallel arms with 1:1:1 allocation. Patients who did not receive beta-blocker at baseline: underwent CTCA without beta blocker (n=49), and receiv…

research product

Coronary artery anomalies: incidence, pathophysiology, clinical relevance and role of diagnostic imaging

Conventional coronary angiography is the gold standard for the diagnosis of coronary artery anomalies. Coronary anomalies are relatively rare findings in patients undergoing conventional coronary angiography for suspected obstructive coronary artery disease. Recently, the increasing performance of diagnostic techniques, such as electron beam tomography (EBT), magnetic resonance (MR) and, more recently, multislice computed tomography (MSCT), has enabled their application to cardiac imaging. MSCT, in particular, has a prominent role in coronary imaging due to its spatial and temporal resolution and three-dimensional capabilities. We report the incidence and pathophysiology of coronary artery …

research product

TAVI imaging: over the echocardiography

Aortic valve stenosis (AS) is a common valvular heart disease. Recently, transcatheter aortic valve implantation (TAVI) has changed the treatment of severe AS in elderly patients with contraindications to traditional surgical replacement. Echocardiography is conventionally used as the first imaging modality to assess the presence and severity of AS and to provide anatomical and functional information. Nowadays, imaging techniques play a crucial role in the planning of TAVI to define suitable candidates. Computed tomography (CT) is essential to display the anatomy of the aortic valve complex (including aortic annulus, Valsalva sinuses, coronary arteries ostia, sinotubular junction), thoracoa…

research product

Influence of heart rate in the selection of the optimal reconstruction window in routine clinical multislice coronary angiography

Purpose. The aim of our study was to assess the influence of heart rate on the selection of the optimal reconstruction window with 40-slice multidetector-row computed tomography (40-MDCT) coronary angiography. Materials and methods. We studied 170 patients (114 men, age 60 +/- 11.3 years) with suspected or known coronary artery disease with 40-MDCT coronary angiography. Patients [mean heart rate (HR) 62.9 +/- 9.3 bpm, range 42-94 bpm] were clustered in two groups (group A: HR &lt;= 65 bpm; group B: HR &gt;65 bpm). Multiphase reconstruction data sets were obtained with a retrospective electrocardiogram (ECG)-gated 40-MDCT coronary angiography scan from 0% to 95% every 5% of the R-R interval.…

research product

Remodeled ostial atherosclerotic plaque in a single coronary artery demonstrated by computed tomography coronary angiography

research product

Influence of increasing convolution kernel filtering on plaque imaging with multislice CT using an ex-vivo model of coronary angiography

PURPOSE: To assess the variability in attenuation of coronary plaques with multislice CT-angiography (MSCT-CA) in an ex-vivo model with varying convolution kernels. MATERIALS AND METHODS: MSCT-CA (Sensation 16, Siemens) was performed in three ex-vivo left coronary arteries after instillation of contrast material solution (Iomeprol 400 mgI/ml, dilution: 1/80). The specimens were placed in oil to simulate epicardial fat. Scan parameters: slices 16/0.75 mm, rotation time 375 ms, feed/rotation 3.0 mm, mAs 500, slice thickness 1 mm, and FOV 50 mm. Datasets were reconstructed using 4 different kernels (B30f-smooth, B36f-medium smooth, B46f-medium, and B60f-sharp). Each scan was scored for the pre…

research product

Computed tomography coronary angiography plaque burden in patients with suspected coronary artery disease.

Purpose To determine the relationship between established cardiovascular risk factors, clinical presentation and the extent of coronary artery disease (CAD), as described with computed tomography coronary angiography. Material and methods In this cross-sectional study, we included 567 symptomatic individuals without a history of CAD who consecutively underwent 64-slice computed tomography coronary angiography for evaluation of suspected CAD. We analyzed the prevalence of CAD depending on sex, age, symptoms and risk factors. Results A total of 8542 segments were analyzed. No evidence of CAD was observed in 225 patients (40%), nonsignificant CAD in 221 patients (39%) and significant CAD (lumi…

research product

Coronary artery calcium score on low-dose computed tomography for lung cancer screening

Aim: To evaluate the feasibility of coronary artery calcium score (CACS) on low-dose non-gated chest CT (ngCCT). Methods: Sixty consecutive individuals (30 males; 73 ± 7 years) scheduled for risk stratification by means of unenhanced ECG-triggered cardiac computed tomography (gCCT) underwent additional unenhanced ngCCT. All CT scans were performed on a 64-slice CT scanner (Somatom Sensation 64 Cardiac, Siemens, Germany). CACS was calculated using conventional methods/scores (Volume, Mass, Agatston) as previously described in literature. The CACS value obtained were compared. The Mayo Clinic classification was used to stratify cardiovascular risk based on Agatston CACS. Differences and corre…

research product

Improving diagnostic accuracy of MDCT coronary angiography in patients with mild heart rhythm irregularities using ECG editing

OBJECTIVE. The objective of our study was to compare diagnostic accuracy of MDCT coronary angiography in a population of patients with mild heart rhythm irregularities before and after editing the ECG. SUBJECTS AND METHODS. Thirty-eight patients who underwent MDCT coronary angiography and conventional coronary angiography were enrolled in the study. The inclusion criterion was the presence of mild heart rhythm irregularities (i.e., premature beats; atrial fibrillation; mistriggering; or low heart rate, defined as 40 beats per minute or less) during the scan. All patients underwent MDCT with the following parameters: 16 detectors; collimation, 0.75 mm; gantry rotation time, 375 msec; 120 kV;…

research product