0000000000367921

AUTHOR

Marcus J. Swann

A real time immunoassay in alumina membranes

To date, photonic biosensing with porous membranes has produced slow responses and long sensing times, due to the narrow (less than 100 nm) closed end pores of the membranes used. Recently, polarimetry was used to demonstrate analyte flow through, and real time biosensing in, free-standing porous alumina membranes. Here, we demonstrate how an improved functionalization technology, has for the first time enabled a real-time immunoassay within a porous membrane with a total assay time below one hour. With the new approach, we show a noise floor for individual biosensing measurements of 3.7 ng/ml (25 pM), and a bulk refractive index detection limit of 5×10-6 RIU, with a standard deviation of l…

research product

Characterization of porous alumina membranes for efficient, real-time, flow through biosensing

Abstract Nanofluidic sensing devices promise high performance by overcoming issues of mass transport of analyte molecules to the sensing surface, whilst micro-porous membranes promise high sensitivity due to a large surface for their capture. Anodic alumina (AAO) filter membranes allow the flow through of samples, and could be used as a convenient and readily available fluidic platform for the targeted delivering of analytes to bioreceptors immobilized on the pore walls. The relatively small pore dimensions, compared to fluidic diffusion lengths, promise highly efficient capture of analytes from the whole sample volume, enabling relatively fast sensing response times and the use of small sa…

research product

Real-time polarimetric biosensing using macroporous alumina membranes

We report the first demonstration of real-time biosensing in free standing macroporous alumina membranes. The membranes with their 200 nm diameter pores are ideal candidates for biosensing applications where fast response times for small sample volumes are needed as they allow analytes to flow through the pores close to the bioreceptors immobilized on the pores walls. A bulk refractive index sensitivity of 5.2x10 -6 refractive index units was obtained from signal responses to different concentrations of NaCl solutions flowing through the pores. Finally, after functionalizing the alumina pore surfaces with an epoxysilane and then spotting it with β-Lactoglobulin protein, the interactions bet…

research product

Real time optical immunosensing with flow-through porous alumina membranes

Through the presentation of analytical data from bioassay experiments, measured by polarimetry, we demonstrate for the first time a real time immunoassay within a free standing macroporous alumina membrane. The 200 nm nominal pore diameter of the membrane enables flow-through, thereby providing an ideal fluidic platform for the targeted delivery of analytes to bioreceptors immobilized on the pore walls, enabling fast sensing response times and the use of small sample volumes (<100 mu L). For the immunoassay, the pore walls were first coated with the functional copolymer, copoly(DMA-NAS) using a novel coupling process, before immobilization of the allergen protein, beta-lactoglobulin, by spo…