0000000000393317
AUTHOR
I. O. O. Korhonen
Glass-capillary gas chromatography of chlorobenzenes on SE-30 and Carbowax 20M columns. Simultaneous determination of chlorobenzenes and chlorophenols
Gas chromatography of benzene and all chlorobenzenes has been studied on SE-30 and Carbowax 20M glasscapillary columns under various operating conditions. The benzene isomers are eluted on both columns according to their boiling points. Separation of all components in a mixture is achieved on Carbowax 20M, whereas on SE-30 the peaks of closely related isomers overlapped. Also one partial overlapping is observed on a non-polar phase. The relative retention times for compounds are given and the retention order is discussed. The retention behaviour of chlorobenzenes and chlorophenols is compared. By using an SE-30 quartz-capillary column a mixture of 33 individual components gives 29 resolved …
Simultaneous gas chromatographic determination of aliphatic C2−C20 n-carboxylic acids and their methyl esters using SE-30 and OV-351 quartz capillary columns
Simultaneous determination of aliphatic C2−C20 carboxylic acids and their methyl esters was carried out using SE-30 and OV-351 quartz capillary columns with temperature programming. Complete resolution of all 36 components was achieved. On SE-30 the methyl ester and the corresponding free acid are eluted in turn, whereas on OV-351 acetic acid eluted after methyl octanoate, after which the Cn methyl ester and Cn-6 carboxylic acid (n>9) are eluted one after the other. A non-polar SE-30 column is better for long-chain acids giving sharp peaks without tailing, the analysis time of the mixture being less than 16 minutes. The weight response correction factors for compounds under optimum operatin…
Quartz-capillary gas chromatography of chlorinated phenols and catechols
The gas chromatography of all chlorinated phenols and catechols on a non-polar SE-30 quartz-capillary column has been studied. The relative retention times of the individual components are given and the elution order is discussed. All of the chlorophenols and chlorocatechols can be separated under appropriate operating conditions but simultaneous determination of all the compounds studied resulted in overlapping peaks. Theortho-effect in catechols is stronger than that in phenols. A different order of elution for the compounds studied to that of the corresponding acetate esters is found. Generally, longer retention times for the latter are observed.
Glass capillary gas chromatography of chlorinated methyl acetates, propanoates and butanoates on Carbowax 20M and SE-30 columns
The gas chromatography of all chlorinated methyl acetates, methyl propanoates and methyl mono- and dichlorobutanoates has been studied on Carbowax 20M and SE-30 glass capillary columns under various running conditions. The order of elution on a non-polar column was largely determined by the boiling point of esters, whereas on a polar column it was much influenced by the structure of compounds. Complete separation of the combined mixture of all 27 compounds could not be achieved, however, methyl 3,3-dichlorobutanoate was the only ester overlapped on both columns in spite of the various column temperatures used. The best separation of the mixture was on Carbowax 20M with a temperature program…
Simultaneous determination of C1−C8 n-alkyl acetates and corresponding mono-, di- and trichloroacetates on glass capillary columns with programmed temperature rise
Gas chromatography of mixtures of aliphaticn-alkyl acetates (CH3−COOR), chloroacetates (CHCl2−COOR), dichloroacetates (CHCl2−COOR) and trichloroacetates (CCl3−COOR), where the alcohol chain length (R) varied between 1 and 8, has been studied on SE-30, Carbowax 20M and OV-351 glass capillary columns with programmed temperatures from 50°C at 2, 4, 6, 8 and 10°C/min. Compounds in the homologous series are eluted in the direct order from methyl ton-octyl acetate. The isomeric chloro esters are eluted on SE-30 according to their boiling points in the order: mono-, di- and trichloro isomer, whereas on polar columns di- and trichloro esters are eluted in the reverse order. The complete separation …