0000000000483830

AUTHOR

Dario Di Cara

showing 97 related works from this author

A prototypal architecture of a IEEE 21451 network for smart grid applications based on power line communications

2015

This paper deals with the development of reliable measurement and communication devices and systems and their integration on a prototypal network architecture for smart grid applications, based on the use of narrowband power line communications (PLCs). The proposed solution is presented and discussed in the framework of the ISO/IEC/IEEE 21451 family of Standards. Currently, PLCs are not properly addressed by the aforesaid Standards; on the other hand, by including such issue, their guidelines could represent a common platform for the integration and interoperability of the proposed systems and devices. This would allow to exploit the benefits of the IEEE 21451 approach also for PLC-based sm…

Network architectureEngineeringExploitbusiness.industryinterface devices smart grids power system communications power system measurements distributed monitoring and control ISO/IEC/IEEE 21451InteroperabilitySettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciAutomationPower-line communicationSmart gridDNP3Embedded systemdistributed monitoring and control; Interface devices; ISO/IEC/IEEE 21451; power system communications; power system measurements; smart gridsElectrical and Electronic EngineeringArchitecturebusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheInstrumentation
researchProduct

A New Coupling Solution for G3-PLC Employment in MV Smart Grids

2019

This paper proposes a new coupling solution for transmitting narrowband multicarrier power line communication (PLC) signals over medium voltage (MV) power lines. The proposed system is based on an innovative PLC coupling principle, patented by the authors, which exploits the capacitive divider embedded in voltage detecting systems (VDS) already installed inside the MV switchboard. Thus, no dedicated couplers have to be installed and no switchboard modifications or energy interruptions are needed. This allows a significant cost reduction of MV PLC implementation. A first prototype of the proposed coupling system was presented in previous papers: it had a 15 kHz bandwidth useful to couple sin…

Control and Optimizationpower system measurementComputer scienceOrthogonal frequency-division multiplexingEnergy Engineering and Power Technologylcsh:Technologypower system communicationNarrowbandsmart gridsElectrical and Electronic EngineeringCenter frequencysmart gridEngineering (miscellaneous)Renewable Energy Sustainability and the Environmentbusiness.industrylcsh:TBandwidth (signal processing)Electrical engineeringpower system measurementsnarrow band power line communicationPower-line communicationElectric power transmissionSmart gridModulationcommunication system performanceICT infrastructure for smart gridbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheEnergy (miscellaneous)VoltageEnergies
researchProduct

Measurement Issues for the Characterization of Medium Voltage Grids Communications

2013

This paper is focused on the measurement issues and procedures for the characterization of medium voltage grids for narrowband power line communications (NB-PLCs), in the perspective of the use and integration of such technology into smart grids communication networks. The fundamentals are given for the characterization of the PLC channel, by means of noise and attenuation measurements. Suitable procedures are also developed for the characterization and modeling of the power system components in the frequency range of interest. Furthermore, the complete model of the PLC system is experimentally validated in a real case study.

EngineeringNoise measurementbusiness.industrycommunication equipmentElectrical engineeringNoise (electronics)Attenuation measurementPower (physics)power system communicationElectric power systemNarrowbandSmart gridtesting communication systemspower system measurements.Electronic engineeringElectrical and Electronic EngineeringbusinessAttenuation measurement communication equipment testing communication systems power system communication power system measurementsSettore ING-INF/07 - Misure Elettriche E ElettronicheInstrumentationCommunication channelVoltageIEEE Transactions on Instrumentation and Measurement
researchProduct

Experimental Evaluation on Narrow Band Power Line Communication in Medium and Low Voltage Smart Grids

2013

The aim of this work is to perform a feasibility study on the power line communication for the development of a new generation of interface devices (IDs) for smart grid and energy storage applications. More in detail, this paper deals with one of the most important issues on this topic, which is the communication system. Among the existing communication technologies, the study is focused on power line communications (PLCs). After an analysis of the state of the art in the field, the main aspects are analyzed, concerning the open issues on the use of PLCs, especially for medium voltage (MV) and low voltage (LV) systems. In this work the use of PLC in MV-LV networks is investigated, by means …

communication systems power system communication power transformers communication equipment testing narrow band power line communication attenuation smart gridsSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Current transformers effects on the measurement of harmonic active power in LV and MV networks

2011

The harmonic active power is used to determine the location of polluting loads, the direction of harmonic power flow and to estimate how consequential a certain current harmonic source is. The highest uncertainties, when measuring harmonic active power, are introduced by the current and voltage transducers. This paper presents experimental results which show the impact of current transformers (CTs) on the accuracy of the harmonic power measurements. An expression for the evaluation of the power error in distorted conditions was developed which can be easily utilized in the case of linear current transducers. It is shown how CTs cannot be considered linear transducers and how the higher the …

instrument transformersEngineeringVoltage and current harmonicsSwitched-mode power supplyAcousticsActive powerTransducersEnergy Engineering and Power TechnologyLinear currentsPower factorHarmonic powerLinear transducersPower errorsPower transformersVoltage transducersHarmonic analysisHarmonic analysisMaximum valuesCurrent transformerElectrical and Electronic EngineeringPower measurementPhase anglesAbsolute valuesHarmonic power flowTotal harmonic distortionbusiness.industryElectric power distributionCurrent harmonicsElectrical engineeringAC powerCurrent transformerMV networksHarmonicsAccuracy classElectric instrument transformersHarmonicPower system harmonicsCurrent transformers (CTs) instrument transformerspower measurement power system harmonics.businessSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Characterization and Error Compensation of a Rogowski Coil in the Presence of Harmonics

2011

This paper reports the results of an experimental study dealing with a commercial Rogowski coil current transducer (RCCT) in the presence of harmonic distortion. The RCCT was observed under two conditions: 1) sinusoidal excitation with frequencies from 50 to 750 Hz and 2) nonsinusoidal excitation using fundamental frequency and one harmonic, with adjustable amplitude and phase shift. The experimental results show only a weak dependence of the harmonic current ratio error and phase displacement on the amplitude and phase shift of the excitation harmonic. The phase displacement is also independent of the conductor position within the Rogowski coil window. An error compensation method, based o…

PhysicsTotal harmonic distortionFrequency responsebusiness.industryAcousticsElectrical engineeringFundamental frequencycurrent transducerRogowski coilCurrent measurement current transducer frequency response harmonic distortion power system harmonics Rogowski coil.harmonic distortionHarmonic analysisAmplitudeHarmonicsHarmonicpower system harmonicElectrical and Electronic EngineeringbusinessInstrumentationSettore ING-INF/07 - Misure Elettriche E ElettronicheRogowski coil
researchProduct

Real-Time Power Flow Monitoring and Control System for Microgrids Integration in Islanded Scenarios

2019

This article presents an enhanced system for real-time power flow monitoring and control (PFMC) for microgrids integration in medium-voltage (MV) distribution networks. The developed solution includes both system architecture and the monitoring and control algorithms, and it has low implementation and installation costs. It is based on the use of hardware and software solutions previously proposed by the authors, i.e., a distributed measurement, a control and communication architecture, and a supervisory control and data acquisition (SCADA) software, which have been enhanced and integrated for the considered application. The SCADA implements a load flow (LF) algorithm for real-time power fl…

Computer sciencepower distribution control020209 energyReal-time computingpower measurementload flow (LF) analysi02 engineering and technologyIndustrial and Manufacturing EngineeringEnergy storagelaw.inventionpower system monitoringSoftwareSCADAlaw0202 electrical engineering electronic engineering information engineeringElectrical and Electronic Engineeringbusiness.industry020208 electrical & electronic engineeringInversion (meteorology)supervisory control and data acquisition (SCADA) systemsmicrogridload flow (LF) analysisControl and Systems EngineeringSystems architectureAdvanced metering infrastructureMicrogridUnavailabilitybusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheRemote controlIEEE Transactions on Industry Applications
researchProduct

Medium Voltage Smart Grid: Experimental Analysis of Secondary Substation Narrow Band Power Line Communication

2013

This paper is focused on the possibility of employing narrow band power line communication (PLC) in medium voltage (MV) distribution networks. The topic is investigated by means of both simulations and experimental tests, which were carried out in the distribution network of Ustica Island. In detail, a two-way MV communication was tested between two secondary substations connected by an MV cable power line. Each substation has a by-pass connection at MV bus-bars and an MV/LV oil filled power transformer. In this paper, the MV and the PLC systems under test are described and the experimental tests are presented, which were carried out to evaluate the parameters of the simulation model. The a…

EngineeringSwitched-mode power supplyPower system communicationPower line communicationsSmart gridPower transformersPower factorEquipment testingCommunication systemsSmart power gridsElectronic engineeringElectrical and Electronic EngineeringInstrumentationElectric power distributionbusiness.industryCommunicationElectrical engineeringAttenuationComputer simulationPower (physics)Power-line communicationElectric power transmissionPower system measurementCommunication equipment testingPower engineeringbusinessAttenuation communication equipment testing communication systems narrow band power line communication power system communication power system measurements smart gridsSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltageIEEE Transactions on Instrumentation and Measurement
researchProduct

A PC-based wattmeter for accurate measurements in sinusoidal and distorted conditions: Setup and experimental characterization

2012

This paper presents the development of a high-accuracy sampling wattmeter, which can be employed with both sinusoidal and distorted input signals. The proposed personal computer (PC)-based system is a simple, portable, and low-cost solution because it is based on two commercial data acquisition boards connected to a common PC. Owing to this solution, the voltage is sensed directly, avoiding expensive voltage dividers, while the current is sensed by means of a noninductive current shunt. Commercial software is also used for data processing and implementation of the virtual instrument. The setup of the PC-based wattmeter is described, with a detailed description of the correction strategy of …

EngineeringVirtual instrumentExperimental evaluationMeasurement uncertaintyNon-inductive currentsInput signalHarmonic distortionElectric power measurementlaw.inventionPC-basedData acquisitionlawExperimental testElectronic engineeringData acquisition harmonic distortion personal computer (PC) -based instrument power measurement power system measurements wattmetersElectrical and Electronic EngineeringSignal samplingInstrumentationVoltage dividersTotal harmonic distortionLow-cost solutionVirtual instrumentationbusiness.industryAnalog to digital convertersData acquisition boardExperimental characterizationVoltage dividerElectrical engineeringData acquisitionMetrological performanceWattmeterAccurate measurementCommercial softwareElectric powerPersonal computersPower qualityPersonal computerPower system measurementMeasurement uncertaintyUncertainty analysisbusinessHigh-accuracySettore ING-INF/07 - Misure Elettriche E ElettronicheWattmetersVoltage
researchProduct

Improvement of Hall Effect Current Transducer Metrological Performances in the Presence of Harmonic Distortion

2010

The performance of Hall effect current transducers (HECTs), under distorted waveform conditions, is usually characterized by means of a frequency response test. In this paper, it was investigated if frequency response is able to correctly evaluate the ratio and the phase errors under distorted conditions. Two HECTs, with the accuracy class level of 1% and 0.5%, respectively, were experimentally characterized under two conditions: 1) sinusoidal excitation with frequencies ranging from 50 to 750 Hz, which is the well-known frequency response test, and 2) nonsinusoidal excitation using fundamental frequency and one harmonic with adjusted amplitude and phase shift. It was found that ratio and p…

Frequency responseElectric current measurementCurrent measurement current transducer frequency response hall effect devices harmonic distortion power system harmonics.AcousticsTransducersPhase (waves)GyratorsNon-sinusoidal excitationHarmonic distortionAccuracy levelFundamental frequenciesHarmonic analysisPhase errorElectric currentsError compensationFrequency responseFrequency response testsWaveformSinusoidal excitationsPhase shiftElectrical and Electronic EngineeringInstrumentationPhysicsTotal harmonic distortionElectric power distributionHall effectCurrent measurementsMetrological performanceCurrent transducerFundamental frequencyLight measurementAmplitudeAccuracy classHarmonicsMagnetic field effectsHarmonicHarmonic amplitudeSettore ING-INF/07 - Misure Elettriche E ElettronicheDistorted waveformsHarmonic componentsHall effect devicesIEEE Transactions on Instrumentation and Measurement
researchProduct

Characterization of clamp-on current transformers under nonsinusoidal conditions

2009

This paper reports the performance of clamp-on current transformers under nonsinusoidal conditions. A set of experimental measurements helped to determine the ratio and the phase errors under two conditions: 1) sinusoidal excitation with frequencies from 45 to 1000 Hz and 2) nonsinusoidal excitation using the fundamental frequency and one harmonic, with adjusted phase shift. It was found that ratio and phase errors are affected by the phase angle between the harmonic and the fundamental and the harmonic amplitude. The effects of conductor location in the current transformer's window and of the air-gap width were also investigated. It was concluded that harmonic phase and ratio errors measur…

Frequency responseMaterials scienceElectric current measurementTransductorAcousticsErrorsTransducersPhase (waves)Energy Engineering and Power TechnologyClamp-on current transformers current transformers (CTs) frequency response power system harmonics transducers.Power transformersDistributed power generationElectric power systemsHarmonic analysisElectric power transmission networksClamp-on current transformersCurrent transformersFrequency responsePower electronicsFrequency measurementElectronic engineeringElectrical and Electronic EngineeringElectrical conductorTomographyComputed tomographyElectric power distributionElectric transformersCircuit faultsFault currentsFundamental frequencyComputerized tomographyFourier seriesCurrent measurementCurrent transformerDiagnostic radiographyElectric instrument transformersElectric frequency measurementPower system harmonicsMedical imagingCurrent transformers (CTs)Air gap (plumbing)Power transmissionElectric network analysisExcitation
researchProduct

A Line Impedance Calculator Based on a G3 PLC Modem Platform

2022

Power line communication (PLC) is one of the most today used technologies for both automatic meter reading and many other smart grid applications. In this framework, a characterization of the electrical network in the PLC frequency range is needed in terms of impedance measurement and received signal level. This can allow choosing the most suitable and less noisy frequency ranges for PLC transmission. Usually, these characterization measurements are performed with dedicated instrumentation and in the absence of mains voltage. This article wants to propose an alternative solution, which allows these kinds of measurements to be performed using electronic boards currently used as on-field appl…

power system communicationsmart grids measurementsimpedance measurement of electrical networkpower line communication (PLC)Electrical and Electronic EngineeringCommunication signalpower system measurementsSettore ING-INF/07 - Misure Elettriche E ElettronicheInstrumentationdistributed measurement systemsIEEE Transactions on Instrumentation and Measurement
researchProduct

Smart interface devices for distributed generation in smart grids: The case of islanding

2017

With the increasing presence of distributed generators (DGs), the implementation of a smart sensors and actuators network in distribution grids has become crucial for different monitoring, management and protection functionalities. For DGs monitoring and control, sensors and actuators are usually embedded in so-called interface devices (IDs) or interface protection systems (IPSs). Existing IDs lack in communication interfaces both to the electrical energy Distribution System Operators (DSOs) and to the DGs inverter. In this framework, the authors have developed a new ID solution and a proper communication architecture, which allow implementing new smart functionalities based on the interact…

Engineering020209 energyInterface (computing)02 engineering and technologyIslanding detectionPower system communicationslaw.inventionpower system communicationIntelligent sensorlawinterface device0202 electrical engineering electronic engineering information engineeringIslandingElectrical and Electronic Engineeringsmart gridInstrumentationbusiness.industry020208 electrical & electronic engineeringSmart gridsInterface devicesPower (physics)Distribution networkSmart gridEmbedded systemDistributed generationPower system measurementInverterDistributed generationbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheRemote control
researchProduct

Arc Fault Detection Method Based on CZT Low-Frequency Harmonic Current Analysis

2017

This paper presents a method for the detection of series arc faults in electrical circuits, which has been developed starting from an experimental characterization of the arc fault phenomenon and an arcing current study in several test conditions. Starting from this, the authors have found that is it possible to suitably detect arc faults by means of a high-resolution low-frequency harmonic analysis of current signal, based on chirp zeta transform, and a proper set of indicators. The proposed method effectiveness is shown by means of experimental tests, which were carried in both arcing and nonarcing conditions and in the presence of different loads, chosen according to the UL 1699 standard…

Engineeringarc fault detection020209 energyseries arcsArc-fault circuit interrupter02 engineering and technologyUL 1699Fault detection and isolationlaw.inventionHarmonic analysisElectric arcarc fault circuit interrupter (AFCI)Arc dischargeslawArc discharges arc fault circuit interrupter (AFCI) arc fault detection electrical safety fault diagnosis home protection interrupters power system harmonics power system measurements series arcs UL 1699Fault current limiterhome protection0202 electrical engineering electronic engineering information engineeringElectronic engineeringElectrical and Electronic EngineeringInstrumentationpower system harmonicsinterruptersbusiness.industry020208 electrical & electronic engineeringfault diagnosispower system measurementsFault indicatorElectrical networkHarmonicelectrical safetybusinessSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

An Innovative Coupling Solution for Power Line Communication in MV Electrical Networks

2019

One of the main problems in the diffusion of power line communication (PLC) in medium voltage (MV) networks is the need of a dedicated PLC coupler to be installed all over the network. To avoid this problem, the authors have studied, prototyped and patented an innovative PLC coupling solution which uses electrical elements embedded in most of the switchgears already installed in MV networks, i.e. the capacitive dividers of the voltage detecting systems (VDS). The new solution prototype is described in this paper, highlighting the advantages in terms of a significant reduction of both direct costs of equipment and infrastructures and indirect costs of installation and service interruption. T…

power line communicationCouplingpower system measurementbusiness.industryOrthogonal frequency-division multiplexingComputer science020209 energyCapacitive sensing020208 electrical & electronic engineeringPower system communicationElectrical engineeringElectrical element02 engineering and technologypower system measurementsMultiplexingSwitchgearPower-line communicationTransmission (telecommunications)smart grids0202 electrical engineering electronic engineering information engineeringbusinessSettore ING-INF/07 - Misure Elettriche E Elettronichecommunication equipment testing2019 1st Global Power, Energy and Communication Conference (GPECOM)
researchProduct

Comparison of two different approaches for harmonic distortion sources assessment

2021

The paper focuses the attention on the comparison of two approaches for power quality assessment in the electric grid. Both approaches are suitable for investigating the harmonic pollution source and discovering if the harmonic source comes from the customer or the utility grid. The two approaches have the same purpose but they are deeply different. The first approach is based on the knowledge of the customer and utility equivalent impedance while the second is based on single point measurement at point of common coupling PCC. In this paper, the advantages and drawbacks of the two approaches are investigated also supported by a case study.

Total harmonic distortionHarmonic pollutionComputer scienceElectronic engineeringHarmonicPower qualityPoint of common couplingSingle pointGridEquivalent impedance transformsHarmonic Emission IEEE Std. 1459-2010 Power QualitySettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Realizzazione di un banco di misura e di un modello in Simulink per la ricerca e la caratterizzazione di reti di accoppiamento per la trasmissione di…

2010

Medium Voltage Network Power Line Communication Coupling NetworksSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

A resilient distributed measurement system for smart grid application

2020

Since the production of energy from renewable energy sources is strongly increasing, the migration from the classical electric grid toward the smart grid is becoming a reality. Distribution System Operators, along with the control of the entire network and its stability, need to address the security and the reliability of the communication channels and the data itself. In this paper a solution is proposed to address these issues. It is based on a distributed measurement system that relies on a wireless network as well as a redundant Power Line communication system in order to transfer the electrical measures to a centralized SCADA server. The collected data are used to run a power flow algo…

Distributed measurement systemsWireless networkbusiness.industryComputer scienceReliability (computer networking)Distributed computingSmart gridGridelectric load flowHuman-machine interfaceslaw.inventionPower-line communicationSmart gridSCADAlawElectrical networknetwork securityElectricitySCADAbusinesscarrier transmission on power linesSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Experimental EMF characterization of a secondary substation

2015

This paper presents the results of the experimental EMC characterization of a new medium/low voltage (MV/LV) secondary substation, which was developed in the framework of the research project "NEW CAB ELARC". It has two MV/LV transformers, with total rated power of 1000 kVA. To perform the experimental characterization, firstly an analysis was performed of the Italian and European standards recommendations. Different approaches were highlighted and the most appropriate procedures were identified for the measurement of the magnetic fields emissions, at power systems frequency (50 Hz) in steady-state conditions. A dedicated test lab was set up for the secondary substation characterization. Th…

EngineeringElectromagnetic compatibility (EMC) secondary substations induction magnetic field electro-smogbusiness.industryElectrical engineeringSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciAutomotive engineeringInduction magnetic fieldlaw.inventionElectromagnetic compatibility (EMC)Electric power systemPower ratingElectro-smoglawSecondary substationsbusinessTransformerSettore ING-INF/07 - Misure Elettriche E ElettronicheLow voltage2015 AEIT International Annual Conference (AEIT)
researchProduct

Characterization of DC series arc faults in PV systems based on current low frequency spectral analysis

2021

Abstract This work presents an experimental study focused on the characterization of series arc faults in direct current (DC) photovoltaic (PV) systems. The aim of the study is to identify some relevant characteristics of arcing current, which can be obtained by means of low frequency spectral analysis of current signal. On field tests have been carried out on a real PV system, in accordance with some tests requirements of UL 1699B Standard for protection devices against PV DC arc faults. Arcing and non-arcing current signals are acquired and compared and the behavior of a set of indicators proposed by authors is analyzed. Different measurement equipment have been used, in order to study th…

Computer scienceApplied Mathematics020208 electrical & electronic engineering010401 analytical chemistryDirect currentPhotovoltaic systemArc fault detection Electrical safety Fault diagnosis PV systems Series arcs UL 1699B02 engineering and technologyCondensed Matter Physics01 natural sciencesSignal0104 chemical sciencesElectric arcArc (geometry)Data acquisition0202 electrical engineering electronic engineering information engineeringElectronic engineeringMetering modeElectrical and Electronic EngineeringCurrent (fluid)InstrumentationSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Comunicazione power line in reti di media e bassa tensione: modellizazione e verifiche sperimentali

2012

Line Communication (PLC) smart grids reti attive
researchProduct

Development of a high-accuracy PC-based wattmeter with commercial data acquisition boards

2011

This paper presents the development of a high accuracy sampling wattmeter, which makes use of two commercial data acquisition boards (DAQs) connected to a common personal computer. Commercial software is also used for data processing and implementation of the virtual instrument. The set up of the PC-based wattmeter is described and a preliminary evaluation of its metrological performances is made by means of two series of experimental tests, which were carried out with an electric power standard and a high performance multifunction calibrator. © 2011 IEEE.

EngineeringVirtual instrumentElectric power measurementPC-basedlaw.inventionSet (abstract data type)Data acquisitionSampling (signal processing)lawExperimental testElectronic engineeringMeasurement theorySampled data control systemsCommercial softwareData processingpower measurements data acquisition wattmeters power system measurements sampled data systems PC-based instrumentsVirtual instrumentationData acquisition boardbusiness.industryMetrological performanceWattmeterData handlingCommercial softwareElectric powerPersonal computersSampled data systemsPower qualityPower system measurementPersonal computerHigh-accuracyInstrumentsbusinessWattmetersSettore ING-INF/07 - Misure Elettriche E Elettroniche2011 IEEE International Instrumentation and Measurement Technology Conference
researchProduct

High-Frequency Experimental Characterization and Modeling of Six Pack IGBTs Power Modules

2016

In this paper, a method to characterize the high-frequency (HF) behavior of six pack insulated gate bipolar transistors (IGBTs) power module (PM) is presented. The method is based on experimental measurements at the external pins of the device and it allows one to extract internal inductive and capacitive parasitic coupling without the knowledge of structural and physical parameters of the PM. The HF model of a six pack IGBTs PM has been developed, in the frequency range of 150 kHz-30 MHz, and it has been implemented in MATLAB environment. The method has been experimentally validated by comparing the frequency behavior of the PM with the simulated response. Moreover, the HF conducted distur…

ImaginationEngineeringmedia_common.quotation_subjectCapacitive sensing02 engineering and technology01 natural sciencesCapacitanceElectromagnetic compatibility (EMC)power conversion0103 physical sciences0202 electrical engineering electronic engineering information engineeringElectronic engineeringElectrical and Electronic EngineeringMATLABElectrical impedancemedia_commoncomputer.programming_language010302 applied physicsCouplingpower semiconductor switchepower semiconductor switchesbusiness.industry020208 electrical & electronic engineeringBipolar junction transistormodelingComputer Science Applications1707 Computer Vision and Pattern Recognitionpower module (PM)electromagnetic couplingControl and Systems EngineeringPower modulebusinessSettore ING-INF/07 - Misure Elettriche E ElettronichecomputerIEEE Transactions on Industrial Electronics
researchProduct

CZT-Based Harmonic Analysis in Smart Grid Using Low-Cost Electronic Measurement Boards

2023

This paper validates the use of a harmonic analysis algorithm on a microcontroller to perform measurements of non-stationary signals in the context of smart grids. The increasing presence of electronic devices such as inverters of distributed generators (DG), power converters of charging stations for electric vehicles, etc. can drain non-stationary currents during their operation. A classical fast Fourier transform (FFT) algorithm may not have sufficient spectral resolution for the evaluation of harmonics and inter-harmonics. Thus, in this paper, the implementation of a chirp-Z transform (CZT) algorithm is suggested, which has a spectral resolution independent from the observation window. T…

Control and OptimizationRenewable Energy Sustainability and the EnvironmentEnergy Engineering and Power TechnologyBuilding and Constructionpower qualityCZTpower quality; harmonic analysis; CZT; smart grid; hardware implementation; low-cost deviceslow-cost devicesharmonic analysisElectrical and Electronic Engineeringhardware implementationsmart gridEngineering (miscellaneous)Settore ING-INF/07 - Misure Elettriche E ElettronicheEnergy (miscellaneous)
researchProduct

Experimental investigation on PLC signal crossing of power transformers

2014

In this work the use of PLC in MV-LV networks is investigated, by means of experimental tests in the case of a two-ways MV/LV communication between two secondary substations. The two substations are connected by a MV overhead power line. Moreover each substation has a by-pass connection at MV bus-bars and a MV/LV power transformer. A ST7580 transceiver is used to inject the communication signal. The transceiver is embedded in a new interface device developed by the authors. In the paper the communication issues are introduced and some experimental tests are presented and discussed. Such tests have been carried out in the presence of voltage net, i.e. 24 kV, with the aim to verify the possib…

EngineeringElectric power distributionbusiness.industrycommunication systems power system communication power transformers communication equipment testing narrow band power line communication attenuation smart gridsOverhead power lineElectrical engineeringcommunication systemsnarrow band power line communicationSignalCurrent transformerpower transformerspower system communicationElectric power transmissionsmart gridsElectronic engineeringPower engineeringTransceiverbusinessSettore ING-INF/07 - Misure Elettriche E Elettronicheattenuationcommunication equipment testingVoltage
researchProduct

An Innovative Measurement Approach for Load Flow Analysis in MV Smart Grids

2016

This paper proposes a novel measurement procedure for load flow analysis in medium voltage (MV) smart grids. The new approach is based on power measurements at low voltage (LV) side of MV/LV distribution substations. Such measurements are carried out by means of power quality analyzers. If compared with the load flow methods based on measurements at the MV side, the proposed approach has a lower cost and it offers an equally reliable measurement system. The proposed algorithm takes the basic concept of the current summation backward/forward method; some modifications are introduced to use LV load powers measurements. To this aim, the MV/LV power transformer is properly modeled and taken int…

EngineeringGeneral Computer Science020209 energy02 engineering and technologyload flow analysispower system monitoring0202 electrical engineering electronic engineering information engineeringElectronic engineeringPower-flow studyMATLABSimulationcomputer.programming_languagebusiness.industrySystem of measurement020208 electrical & electronic engineeringAdvanced metering infrastructure load flow analysis power quality analyzer (PQA) power system measurements power system monitoring smart grid (SG).AC powerpower quality analyzer (PQA)power system measurementsPower (physics)smart grid (SG)Settore ING-IND/33 - Sistemi Elettrici Per L'EnergiaSmart gridAdvanced metering infrastructurebusinesscomputerLow voltageSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltage
researchProduct

Strumento virtuale in ambiente LabVIEW per la gestione automatica di misure di emissione radiata in camera semianecoica

2010

Electromagnetic Compatibility Semi-Anechoic Chamber Radiated EmissionsSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

NB PLC and Software Defined Networking for Smart Grid Applications

2017

During the last years, the installation of Distributed Energy Resources (DERs) and the expected diffusion of Electrical Vehicles (EVs), is increasing the complexity of the distribution grid, making the management of the grid operated by Distribution System Operators (DSOs) more difficult. The Smart Grid approach tries to provide a response to these troubles, by means of a strong interaction between the power grid and Information and Communication Technology (ICT) infrastructures. The drawback of this approach is an increase in the management effort of the ICT infrastructures, for which the DSO are not prepared. Software Defined Networking (SDN) is an approach developed to manage complex ICT…

EngineeringSoftware Defined Networking020209 energyDistribution Grid AutomationEnergy Engineering and Power TechnologyNarrow-Band Power02 engineering and technologyNarrow-Band Power Line Communication0202 electrical engineering electronic engineering information engineeringPerformance CharacterizationSmart GridProtocol (object-oriented programming)ModbusInstrumentationbusiness.industryLine Communication020208 electrical & electronic engineeringGridPower-line communicationSmart gridTransmission (telecommunications)Embedded systemDistributed generationbusinessSoftware-defined networkingSettore ING-INF/07 - Misure Elettriche E ElettronicheComputer network
researchProduct

PQ and Harmonic Assessment Issues on Low-Cost Smart Metering Platforms: A Case Study

2020

This paper presents a feasibility study on how to implement power quality (PQ) metrics in a low-cost smart metering platform. The study is aimed at verifying the possibility of implementing PQ monitoring in distribution networks without replacing existing smart metering devices or adding new modules for PQ measurements, thus zeroing the installation costs. To this aim, an electronic board, currently used for remote energy metering, was chosen as a case study, specifically the STCOMET platform. Starting from the specifications of this device, the possibility of implementing power quality metrics is investigated in order to verify if compliance with standard requirements for PQ instruments ca…

smart meterSmart meterComputer science020209 energy02 engineering and technologylcsh:Chemical technologyBiochemistryArticleAnalytical Chemistry0202 electrical engineering electronic engineering information engineeringlcsh:TP1-1185Metering modeElectrical and Electronic EngineeringInstrumentationvoltage and current sensing020208 electrical & electronic engineeringpower qualityAtomic and Molecular Physics and OpticsCurrent transformerReliability engineeringTransducerEnergy meteringharmonic analysisHarmonicPower qualitySettore ING-INF/07 - Misure Elettriche E ElettronicheLow voltageVoltageSensors
researchProduct

An Improved Load Flow Method for MV Networks Based on LV Load Measurements and Estimations

2019

A novel measurement approach for power-flow analysis in medium-voltage (MV) networks, based on load power measurements at low-voltage level in each secondary substation (SS) and only one voltage measurement at the MV level at primary substation busbars, was proposed by the authors in previous works. In this paper, the method is improved to cover the case of temporary unavailability of load power measurements in some SSs. In particular, a new load power estimation method based on artificial neural networks (ANNs) is proposed. The method uses historical data to train the ANNs and the real-time available measurements to obtain the load estimations. The load-flow algorithm is applied with the e…

Artificial neural networksBusbarComputer sciencepower system measurement020208 electrical & electronic engineeringArtificial neural networks (ANNs)power system managementpower measurementFlow method02 engineering and technologypower system measurementsload flow (LF)Power (physics)Control theoryload flowsmart grids0202 electrical engineering electronic engineering information engineeringstate estimationElectrical and Electronic Engineeringsmart gridInstrumentationSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltage
researchProduct

An interface protection system with power line communication for distributed generators remote control

2014

The aim of this work is to present a narrow band power line communication (NB-PLC) interface protection system (IPS) for distributed generators (DGs); it has been developed according to the current standard CEI 0-21 and the requirements for smart grid applications. For such applications, the new IPSs have to implement new intelligent functions such as remote monitoring and control of DGs and Energy Storage Systems (ESSs) inverters, not only in terms of disconnection but also of voltage regulation and power modulation by the utility control. The main feature of the developed IPS is the ability to interact with both the grid and the DG's and ESS's inverters. In fact, it can communicate with t…

power line communicationEngineeringdistributed generationbusiness.industryinterface protection systemsRemote monitoring and controlpower system communicationsPower-line communicationSmart gridDistributed generationsmart gridsdistributed generation interface protection systems smart grids power system communications power line communication islanding detectionGrid-connected photovoltaic power systemElectronic engineeringislanding detectionVoltage regulationbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheModbusPower control2014 IEEE International Workshop on Applied Measurements for Power Systems Proceedings (AMPS)
researchProduct

Un metodo ibrido per il riconoscimento dell'islanding in reti di media e bassa tensione in presenza di generazione distribuita

2013

Islanding Detection smart grids active distribution networks power system communications power line communication distributed generation interface devicesSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Characterization of IP-Based Communication for Smart Grid Using Software-Defined Networking

2018

The smart grid (SG) approach is based on a strong interaction between the network communication infrastructure and the power grid. Usually the management of the infrastructure is done by the distribution system operators (DSOs) that are worried about the increasing managing complexity due to the presence of increasing number of distributed energy resources and electrical vehicles. The use of software-defined networking (SDN) may simplify the network configuration and management for DSO, as highlighted from previous research works. The objective of this paper is to introduce and characterize an internet protocol (IP)-based communication architecture with specialized SDN bridges operating als…

smart grid (SG).IEC 61850Computer science020209 energyThroughput02 engineering and technologyRound-trip delay timelaw.inventionPacket losslawInternet Protocol0202 electrical engineering electronic engineering information engineeringElectrical and Electronic EngineeringInstrumentationbusiness.industry020208 electrical & electronic engineeringDistribution grid automationsoftware-defined networking (SDN)Power-line communicationSmart gridDistributed generationbusinessSoftware-defined networkingnarrowband power line communication (NB-PLC)Settore ING-INF/07 - Misure Elettriche E Elettronicheperformance characterizationComputer network
researchProduct

An Experimental Characterization of Time of Arrival Accuracy for Time Synchronization of Medium Voltage Smart Grid Solutions

2019

The time synchronization of smart grid devices is a critical feature for the successful application of advanced grid monitoring and control techniques. Synchronization mechanisms based on the accurate estimation of the Time of Arrival (ToA) of network messages - sent over power line cables - are a promising solution to achieve synchronization tasks over distribution lines. In this paper, a chirp-based synchronization technique over the Medium Voltage (MV) grid has been proposed and characterized. Such approach has the benefit of not requiring the installation of a dedicated infrastructure, thanks to the exploitation of power distribution lines for the transmission of time synchronization da…

Performance EvaluationComputer scienceMedium Voltage Distribution GridGridTime of ArrivalPower (physics)Time of arrivalSmart gridTransmission (telecommunications)Time SynchronizationSynchronization (computer science)Electronic engineeringChirpSmart GridChirp modulationSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltage2019 IEEE 10th International Workshop on Applied Measurements for Power Systems (AMPS)
researchProduct

Caratterizzazione metrologica di trasduttori di corrente in presenza di distorsione armonica

2007

researchProduct

A New Low Cost Coupling System for Power Line Communication on Medium Voltage Smart Grids

2018

This paper proposes and verifies the performance of an innovative and low cost coupling system for power line communication (PLC) on medium voltage (MV) smart grids. The coupling system makes use of the capacitive divider of the voltage detecting systems (VDSs) to inject and receive the PLC signal. VDS are usually already installed in the MV switchboards of the major electrical manufacturer all over the world according to IEC 61243-5. VDS are used to detect the presence of the mains voltage to guarantee personnel safety. An interface circuit has been developed to be connected between the PLC transceiver and the VDS socket. In this way, the PLC signal can be coupled to the MV network without…

EngineeringGeneral Computer Sciencebusiness.industry020209 energycommunication systems; couplers; narrow band power line communication; Power system communication; power system communication; power system measurements; smart grids020208 electrical & electronic engineeringElectrical engineering02 engineering and technologyCapacitanceSignalPower-line communicationSmart gridModulationPower system communication communication systems couplers narrow band power line communication communication signal couplers power system communication power system measurements smart grids.0202 electrical engineering electronic engineering information engineeringElectronic engineeringcommunication signal couplersTransceiverbusinessElectrical impedanceSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltage
researchProduct

Frequency response of Measurement Current Transformers

2008

In this paper the frequency response of two CTs is experimentally evaluated in the range of 30-600 Hz. A theoretical analysis of CTs behavior has been developed by means of the equivalent circuit. It was shown, by an experimental test, that, for the frequency range analyzed, the transformer equivalent circuit is a valid tool for the evaluation of CT performances.

Frequency responseTotal harmonic distortionMaterials scienceTransducerlawPower system harmonicsElectronic engineeringEquivalent circuitIec standardsTransformerCurrent transformerHardware_LOGICDESIGNlaw.invention2008 IEEE Instrumentation and Measurement Technology Conference
researchProduct

Design and Characterization of a New MV PLC Coupler for Smart Electric Energy Systems

2018

This paper deals with the design, modeling and characterization of a new coupling system for medium voltage (MV) narrow band power line communications (NB-PLC). It exploits the capacitive divider of voltage detecting systems (VDSs) normally used to reveal the mains voltage presence, thus avoiding the use of dedicated MV couplers. The proposed coupling system was patented by the authors. In this paper, the modeling of the VDS capacitive divider is presented, using a proper characterization method. Moreover, the interface card design is described, based on simulation of the whole PLC transmission channel. Laboratory tests are also presented and discussed. More in detail, a frequency response …

Frequency-shift keyingComputer sciencepower system measurementInterface (computing)power system measurementsnarrow band power line communicationLine (electrical engineering)Power (physics)power system communicationNarrowbandTransmission (telecommunications)communication system performanceElectronic engineeringsmart gridssmart gridElectrical impedanceSettore ING-INF/07 - Misure Elettriche E Elettronichecommunication equipment testingVoltage
researchProduct

Hall Effect Clamp-on Current Transducer Characterization under Nonsinusoidal Conditions

2009

Current TransducerSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Implementation of a Management System for Prosumer Energy Storage Scheduling in Smart Grids

2020

Scheduling of energy storage systems of distributed generation is a key element for optimal renewable energy sources (RES) exploitation in smart grids, demand side response strategies implementation and prosumers interaction with Distribution System Operators (DSOs). In this context, this paper presents the implementation of a management system for energy storage scheduling, which allows taking appropriate account of the storage system behavior in real cases. To properly consider the real system operation, the employed battery model is modified, in order to include also the hysteresis phenomena in state of charge estimation in both charging and discharging operation. The validation of the p…

Battery (electricity)Computer sciencedistributed measurement system020209 energyDistributed computingScheduling (production processes)Context (language use)02 engineering and technologyoptimzationbattery management systemEnergy storagesizing0202 electrical engineering electronic engineering information engineeringschedulingdistribution systemdistributed generationbusiness.industryenergy storage020208 electrical & electronic engineeringdemand side responsesmart power gridsState of chargeSmart gridDistributed generationComputer data storagebusinessPSO.Settore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

A PC-based wattmeter for high accuracy power measurements

2010

This paper proposes the use of a commercial data acquisition board (DAQ) connected to a common personal computer for high accuracy power measurements. In the paper the set up of the PC-based wattmeter is described and an experimental evaluation of its metrological performances is made by means of the comparison with a simultaneous coherent digital sampling wattmeter realized with two high-precision DMMs Hewlett Packard Model 3458 A. In both cases the power source is a Fluke 6100A/E electrical power standard. © 2010 IEEE.

EngineeringExperimental evaluationHigh-precisionElectric power measurementlaw.inventionPC-basedPower sourcesSet (abstract data type)Data acquisitionSampling (signal processing)lawElectronic engineeringPower measurementMeasurement theoryHewlett Packard modelsbusiness.industryData acquisition boardDigital samplingElectrical engineeringMetrological performanceWattmeterElectrical powerelectric power measurement digital sampling wattmeters data acquisition board pc-based instrumentPower (physics)MetrologyPersonal computersElectrical power measurementsPersonal computerElectric powerbusinessInstrumentsSettore ING-INF/07 - Misure Elettriche E ElettronicheWattmetersElectric power supplies to apparatus
researchProduct

A simplified approach for load flow analysis in MV smart grids based on LV power measurements

2017

This paper presents a simplified approach for load flow analysis in medium voltage (MV) distribution networks. It is a power summation Backward/Forward (B/F) algorithm, based on measurements of active and reactive powers at low voltage (LV) side of MV/LV distribution substations. The proposed solution allows achieving good accuracy, computational efficiency and fast convergence. In order to verify the algorithm performances, simulation studies are carried out in the case of a real test system, i.e. the distribution grid of Favignana Island (Mediterranean Sea, Italy). The compatibility between simulations results and power measurements at the MV bus bars of the generating substation shows th…

EngineeringBusbar020209 energyBiomedical EngineeringAdvanced metering infrastructure (AMI)Smart grid02 engineering and technologyload flow analysisControl theory0202 electrical engineering electronic engineering information engineeringElectronic engineeringPower-flow studyInstrumentationPower system monitoringbusiness.industry020208 electrical & electronic engineeringAC powerSmart gridPower system measurementSignal ProcessingLoad flow analysiAlgorithm designPower system measurementsDistribution gridPower quality analyzers (PQA)businessSettore ING-INF/07 - Misure Elettriche E ElettronicheLow voltageVoltage2017 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)
researchProduct

Simulation of a Power Line Communication System in Medium and Low Voltage Distribution Networks

2011

The aim of the paper is to study the influence of the power transformer on signal transmission in the case of a power line communication (PLC) system in a overhead Medium Voltage (MV) power network. A model of the PLC system was carried out by means of the Simulink® software. A distributed parameter MV overhead line, two power transformers, the signal coupling networks and the receiving and transmitting line coupling interface of a ST7540 FSK powerline transceiver were included in the model. The performances of the complete PLC communication system are evaluated for different line lengths by means of the attenuation computed as ratio between the received and transmitted voltage signals.

power line communicationEngineeringbusiness.industryElectrical engineeringpower transformerCommunications systemSignalLine (electrical engineering)overhead linepower system communicationPower-line communicationmedium voltagemedium voltage communication system power system communication overhead line communication equipment testing power line communication attenuationElectronic engineeringOverhead (computing)communication systembusinessLow voltageSettore ING-INF/07 - Misure Elettriche E ElettronicheOverhead lineattenuationcommunication equipment testingVoltage
researchProduct

Innovative Solutions for the Integration of Renewable Energies on Tunisian and Sicilian Electrical Grids

2022

The rapid spread of distributed generation from renewable energy sources, combined with their unpredictable behavior, requires the continuous monitoring and control by the Distribution System Operator, in order to guarantee the stability and efficiency of the distribution network. Thus, in this paper a new measurement and communication architecture is proposed, which foresees the use of innovative devices and different technology-oriented solutions, even redundant ones, which allows the transition from passive to active electricity distribution network, with minimal structural changes. The architecture has been developed in the framework of the SInERT project (Italy-Tunisia cross-border coo…

power line communicationPower system communicationsmart gridsCommunication signalcommunication systemspower system measurementsSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Realizzazione in ambiente LabVIEW di un sistema automatico di gestione della cella GTEM per prove di compatibilità elettromagnetica

2010

Electromagnetic Compatibility GTEM Cell Radiated EmissionsSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

High frequency modeling technique for three phase power electronics module

2015

Nowadays, the high integrated power electronics modules (PMs), characterized by high speed, low loss and hard ware miniaturization, represent a new technology that meets the emerging demands of many applications, such us vehicle and home appliance, renewable energy sources in smart grid. The integration process and the high switching speeds increase the PM electromagnetic emissions that can create electromagnetic interference (EMI) with electric/electronic devices near the PMs. For this reason, electromagnetic compatibility (EMC) have to be carefully considered, yet in the design phase, to guarantee the reliability of PM systems. In this paper a method to develop a high frequency (HF) model…

MarketingEngineeringRenewable Energy Sustainability and the Environmentbusiness.industryElectromagnetic compatibilityEnergy Engineering and Power TechnologyPower moduleElectromagnetic interferenceElectromagnetic interferenceStrategy and Management1409 Tourism Leisure and Hospitality ManagementSmart gridEMIHigh frequency modelingPower modulePower electronicsMiniaturizationElectronic engineeringElectromagnetic compatibilityElectronicsbusinessSettore ING-INF/07 - Misure Elettriche E Elettroniche2015 5th International Conference on Electric Utility Deregulation and Restructuring and Power Technologies (DRPT)
researchProduct

A New Solution for Low-Voltage Distributed Generation Interface Protection System

2015

In this paper, a new solution is proposed for the remote monitoring and control of distributed generators (DGs) and energy storage systems (ESSs) connected to low-voltage distribution networks. The proposed system fulfills the in-force standard requirements for the connection of DGs to the utility grid. Moreover, it allows implementing some enhanced functions for the remote control of inverters of DGs and ESSs, not only in terms of disconnection but also in terms of voltage regulation and power shuttering. The proposed solution is based on a new interface protection system and a dedicated secondary substation concentrator, which allows the communication between the distributed system operat…

Engineeringpower system communicationsNoise (electronics)law.inventionpower system communicationCommunication system interfacesdistributed power generationpower system protectionlawpower line communication (PLC)smart gridsElectronic engineeringElectrical and Electronic EngineeringInstrumentationCommunication system interfacebusiness.industryElectrical engineeringGridinterface protection systems (IPSs)Power (physics)Transmission (telecommunications)Electrical networkDistributed generationVoltage regulationbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheLow voltageIEEE Transactions on Instrumentation and Measurement
researchProduct

Un wattmetro basato su schede di acquisizione commerciali per misure in regime distorto. Sviluppo dello strumento e prove preliminari

2012

schede di acquisizione dati pc-based instruments misure di potenza incertezza di misura
researchProduct

LV Measurement Device Placement for Load Flow Analysis in MV Smart Grids

2016

This paper deals with the issue of measurement device placement for load flow analysis in medium-voltage (MV) distribution networks. The study is carried out using an innovative measurement algorithm for load flow analysis developed by the authors. It is based on low-voltage (LV) load power measurements applied on a backward/forward algorithm for the load flow resolution. The final aim is to identify the most suitable number and placement of the LV measurement points in order to limit the uncertainty on the power flow estimation to a target value. The proposed approach is based on the uncertainty evaluation of the estimated power flows; a sensitivity analysis is performed in order to assess…

Engineering020209 energy02 engineering and technologyPower factormeter placementpower system monitoringControl theorysmart grids0202 electrical engineering electronic engineering information engineeringElectronic engineeringpower measurementsPower-flow studySensitivity (control systems)Electrical and Electronic EngineeringInstrumentationbusiness.industry020208 electrical & electronic engineeringpower quality analyzer (PQA)power system measurementsPower (physics)Smart gridload flow (LF) analysisFlow (mathematics)Advanced metering infrastructure load flow (LF) analysis meter placement power measurements power quality analyzer (PQA) power system measurements power system monitoring smart grids.Advanced metering infrastructureMeasurement uncertaintyAlgorithm designbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheIEEE Transactions on Instrumentation and Measurement
researchProduct

Enhanced islanding detection in smart interface protection systems of distributed generation

2021

The widespread presence of distributed generators (DGs) and storage systems (DSSs) in electricity grids has increased the risk of islanding occurrence. This phenomenon must be suitably managed by Distribution System Operators (DSO), in order to avoid adverse situations, in terms of grid-protection problems, equipment damage, safety hazards, power quality problems and so on. Currently anti-islanding protection functions are handled by interface protection systems (IPSs), which are built in accordance with relevant standards for DGs and DSSs connection to power systems. However, some problems may occur in case of operation within the so-called non detection zone (NDZ). This paper presents an …

Computer sciencebusiness.industryInterface (computing)distributed generation distribution network Interface protection systems islanding detection power system communications power system measurement smart gridsDirect-sequence spread spectrumProtection systemReliability engineeringSpread spectrumElectric power systemDistributed generationIslandingElectricitybusinessSettore ING-INF/07 - Misure Elettriche E Elettroniche2021 3rd Global Power, Energy and Communication Conference (GPECOM)
researchProduct

Hybrid passive and communications-based methods for islanding detection in medium and low voltage smart grids

2013

Islanding condition takes place when a distributed generator (DG) continues to power a part of the grid even if power from electric utility is no longer present. Adverse effects of islanding are power quality deterioration, grid-protection interference, equipment damage, and personnel safety hazards. For these reasons, DG systems must detect an islanding condition and immediately disconnect from the grid (anti-islanding protection). This paper proposes an hybrid solution, for both low voltage (LV) and medium voltage (MV) applications, which makes use of passive and communication-based methods for islanding detection. Among the existing communication technologies, the study is focused on pow…

Engineeringdistributed generationbusiness.industryElectrical engineeringGridPower (physics)interface devicesElectric utilitySmart gridIslanding Detection smart grids active distribution networks power system communications power line communication distributed generation interface devicesElectronic engineeringIslandingactive distribution networksbusinessLow voltagepower line communication power system communications smart gridsSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltagePower controlIslanding Detection
researchProduct

Implementation and Experimental Tests of a Management System for MV/LV Distribution Grids

2019

The continuous monitoring of network power flows and the remote control of Distributed Generators and Energy Storage Systems are the essential elements to allow a full exploitation of Renewable Energy Sources and their real integration in distribution networks. Thus in the paper a management system is presented for load flow monitoring in MV/LV distribution network. Moreover, on the basis of calculated power flows, the management system is able to send control commands to DGs and ESSs, to vary their power production or power factor or eventually to disconnect them in order to maintain the network stability. The proposed solution was really implemented in the MV network of Ustica Island, dev…

business.industryComputer scienceLoad flow020209 energy020208 electrical & electronic engineeringContinuous monitoringElectrical engineeringSmart grid02 engineering and technologyPower factorEnergy storageRenewable energylaw.inventionSCADAlawMobile stationPower system measurement0202 electrical engineering electronic engineering information engineeringDistributed generationbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheLow voltageRemote control2019 International Conference on Clean Electrical Power (ICCEP)
researchProduct

Electromagnetic immunity analysis of a new interface device with power line communication for smart grid and energy storage applications

2013

An analysis of EMC standards related to smart grid devices with PLC port has been carried out and the standardization lacks have been pointed out with reference to the evaluation of electromagnetic immunity to narrowband, coming from other communication systems connected to the grid, and RF disturbances conducted disturbances, usually present in a power grid. In particular, the paper analyses the electromagnetic conducted immunity of a new interface protection device (ID) for smart grid and energy storage applications. The new ID is equipped with a measuring board, a STM32 microcontroller, for data elaboration and memorization, and a ST7580 N-PSK powerline transceiver. An experimental test …

Engineeringsmart power grids.energy storagebusiness.industryElectrical engineeringElectromagnetic compatibilitySTM32Communications systemGridMicrocontrollerPower-line communicationSmart gridHardware_GENERALEMCElectronic engineeringTransceivercarrier transmission on power linesbusinessSettore ING-INF/07 - Misure Elettriche E Elettronicheelectromagnetic compatibilitymicrocontrollers2013 IEEE 17th International Symposium on Power Line Communications and Its Applications
researchProduct

A new method for forecasting energy output of a large-scale solar power plant based on long short-term memory networks a case study in Vietnam

2021

Abstract This paper proposes a new model for short-term forecasting power generation capacity of large-scale solar power plant (SPP) in Vietnam considering the fluctuations of weather factors when applying the Long Short-Term Memory networks (LSTM) algorithm. At first, a configuration of the model based on the LSTM algorithm is selected in accordance with the weather and operating conditions of SPP in Vietnam. Not only different structures of LSTM model but also other conventional forecasting methods for time series data are compared in terms of error accuracy of forecast on test data set to evaluate the effectiveness and select the most suitable LSTM configuration. The most suitable config…

Scale (ratio)Computer scienceLarge scale solar power plant020209 energy020208 electrical & electronic engineeringEnergy Engineering and Power Technology02 engineering and technologySet (abstract data type)Mean absolute percentage errorElectricity generationSolar power plantArtificial IntelligenceStatistics0202 electrical engineering electronic engineering information engineeringLong short-term memoryElectrical and Electronic EngineeringTime seriesPV power plantForecasting PV powerEnergy (signal processing)Test data
researchProduct

IEEE Std 1459–2010. IEEE Standard Definitions for the Measurement of Electric Power Quantities under Sinusoidal, Nonsinusoidal, Balanced or Unbalance…

2010

Definitions used for measurement of electric power quantities under sinusoidal, nonsinusoidal, balanced, or unbalanced conditions are provided in this standard. Mathematical expressions that were used in the past, as well as new expressions, are listed, as well as explanations of the features of the new definitions.

active power apparent power nonactive power power factor reactive power total harmonic distortionSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

An interface protection system based on an embedded metrology system platform

2021

Abstract The aim of this work is to present an interface protection system (IPS) for Distributed Generators (DG) and Energy Storage Systems (ESS). The new prototype of IPS guarantees standard protection requirements, in terms of both voltage and frequency measurement accuracies and trip times. Moreover, it has the additional functionalities of implementing a communication link between the Distribution System Operator (DSO) and the DG and ESS Inverter. The new IPS is based on a smart meter platform with an integrated power line communication modem. Moreover, it has also an integrated metrology section. Experimental tests will show how this last feature allows a significant reduction of the m…

Smart meterbusiness.industryComputer scienceInterface (computing)Smart gridElectric apparatus and materials. Electric circuits. Electric networksIndustrial and Manufacturing EngineeringElectronic Optical and Magnetic MaterialsMetrologyReduction (complexity)Power-line communicationData accessMechanics of MaterialsProtection systemsInverterSmart meterElectrical and Electronic EngineeringDistributed generationTK452-454.4businessSettore ING-INF/07 - Misure Elettriche E ElettronicheComputer hardwareVoltageStorage systems
researchProduct

On the use of narrow band power line as communication technology for medium and low voltage smart grids

2012

The aim of this work is to perform a feasibility study on the power line communication for the development of a new generation of interface devices (IDs) for smart grid applications. More in detail, this paper deals with one of the most important issues on this topic which is the communication system. Among the existing communication technologies, the study is focused on power line communications (PLCs). After a analysis of the state of the art in the field, the main aspects are analyzed, concerning the open issues on the use of PLCs, especially for medium voltage (MV) and low voltage (LV) systems. In this work the use of PLC in MV-LV networks is investigated, by means of simulations and ex…

EngineeringPower Line Communication (PLC)business.industryactive networksOverhead power lineElectrical engineeringCommunications systemlaw.inventionpower system communicationPower-line communicationSmart gridlawsmart gridsdistributionElectronic engineeringPower Line Communication (PLC) smart grids active networks power system communication distribution networksbusinessTransformerSettore ING-INF/07 - Misure Elettriche E ElettronicheLow voltageVoltageActive networking2012 IEEE International Instrumentation and Measurement Technology Conference Proceedings
researchProduct

Model of line to shield power line communication system on a Medium Voltage network

2010

In this paper a complete model of a power line communication (PLC) system on a Medium Voltage (MV) network is presented in the case of a line-ground configuration. A simple and friendly Simulink (R) software is used to develop the model. A distributed parameter MV cable model in line-ground configuration is considered together with the power transformers, the signal coupling networks and the receiving and transmitting line coupling interface of a ST7540 FSK powerline transceiver. The performances of the complete PLC communication system are evaluated for different line lengths by means of the attenuation computed as ratio between the received and transmitted voltage signals.

power line communicationEngineeringFrequency-shift keyingbusiness.industryElectrical engineeringattenuation constantCommunications systemSignalPower-line communicationPower system simulationmedium voltageElectronic engineeringLine (text file)Transceiverbusinessmedium voltage power line communication attenuation constantComputer Science::Information TheoryVoltage2010 IEEE Instrumentation & Measurement Technology Conference Proceedings
researchProduct

A DAQ-based sampling wattmeter for IEEE Std. 1459-2010 powers measurements. Uncertainty evaluation in nonsinusoidal conditions

2015

Abstract This paper presents the evaluation of the metrological performances of a DAQ-based sampling wattmeter (DAQ-SW) for the measurement of IEEE Std. 1459-2010 power quantities in non-sinusoidal conditions. The instrument makes use of two commercial data acquisition (DAQ) boards, a non-inductive current shunt, a personal computer and a commercial software for data processing. Starting from the results of an experimental characterization of the two instrument channels with non-sinusoidal voltages and currents and a correlation analysis, the combined standard uncertainties of IEEE Std. 1459-2010 quantities are evaluated, following the approach of the ISO Guide to the Expression of Uncertai…

EngineeringPC-based instrumentsHarmonic distortionlaw.inventionData acquisitionlawElectronic engineeringElectrical and Electronic EngineeringPower measurements IEEE Std. 1459-2010 Data acquisition Uncertainty Harmonic distortion PC-based instrumentsInstrumentationIEEE Std. 1459-2010Data processingTotal harmonic distortionCommercial softwarebusiness.industryApplied MathematicsElectrical engineeringUncertaintyData acquisitionWattmeterCondensed Matter PhysicsMetrologyPersonal computerMeasurement uncertaintybusinessSettore ING-INF/07 - Misure Elettriche E ElettronichePower measurements
researchProduct

A new low cost power line communication solution for smart grid monitoring and management

2018

Modern smart grids require the improvement of measurement and communication infrastructures of distribution networks, at both medium voltage (MV) and low voltage (LV) levels. Distributed sensing and measurement systems are needed to provide all necessary data for grid monitoring, control and management, as well as for the implementation of a number of smart functionalities, such as remote control of distributed generators (DGs), real time analysis of power flows, automatic meter reading (AMR), demand side management (DSM), grid automation and so on [1]-[6]. Acquired network data include typical electrical network quantities and status variables (such as powers, voltages, currents, switches …

Computer science020209 energy02 engineering and technologyCommunication infrastructureSmart grid monitoringlaw.inventionDistributed sensingElectric power transmission networkslaw0202 electrical engineering electronic engineering information engineeringDemand Side Management (DSM)Electrical and Electronic EngineeringInstrumentationbusiness.industry020208 electrical & electronic engineeringElectrical engineeringPower system communication narrow band power line communication communication signal couplers power system communication power system measurements smart gridsGridAutomationPower-line communicationSmart gridCarrier transmission on power linesElectrical networkControl and managementbusinessLow voltageSettore ING-INF/07 - Misure Elettriche E ElettronicheRemote controlAutomatic meter readingAutomatic meter reading
researchProduct

A back to back method for the temperature rise test of prefabricated substations: A case study

2015

In this work a back to back method is presented which allows to develop heating tests of prefabricated secondary substations with a limited number of supplying equipment (an induction regulator and a capacitor bank). The proposed method makes use of the transformer tap changers to create a voltage difference on the medium voltage side. In this way, only an adjunctive low voltage supply is needed. With the proposed test system, the heating tests are developed on a 1000 kVA prefabricated substation. Thanks to the experimental tests, the class of enclosure of the substation and the operating temperature and resistance of the power transformers are determined, according to the recommendations o…

Engineeringbusiness.industryprefabricated substationRenewable Energy Sustainability and the EnvironmentElectrical engineeringpower transformerEnergy Engineering and Power TechnologyPower factorInduction regulatorSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciDistribution transformerTap changerAutomotive engineeringlaw.inventionlawEnergy efficient transformertemperature riseVoltage regulationheating testDelta-wye transformerbusinessTransformerSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Experimental evaluation of an hybrid communication system architecture for smart grid applications

2015

In this paper a new communication system architecture is proposed for the development of a SCADA system which can remotely monitor and control intelligent electronic devices (IEDs) connected to the low voltage distribution networks, i.e low voltage smart meter (SM), interface protection devises (IPS). New distributed metering systems and interface devices, together with a proper communication infrastructure (HiperLAN and narrowband power line communication (NB-PLC) on low voltage network), have been developed to allow monitoring the whole power system and controlling the distributed generators of a Smart Grid also in the presence of harmonic distortions. In this way, the electrical energy d…

EngineeringSmart meterbusiness.industryInterface (computing)Electrical engineeringsmart grids power system communications power line communication smart meter distributed generation interface protection systemsCommunications systemElectric power systemPower-line communicationSmart gridSCADAElectronic engineeringbusinessLow voltageSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Electric and magnetic emission in near field region and thermal behaviour of power module for photovoltaic application

2015

The new power module, characterized by high power density, miniaturization of packages and layout and high frequency switching, are increasingly used in the field of in automotive, aircraft industry and for Distributed Generation (DG) connected to smart grid. To guarantee the reliability and safety of these systems, the electromagnetic compatibility (EMC) and thermal behavior, have to be carefully considered for these appliances. This paper describes a measurement methodology to characterize the electromagnetic emissions in near field zone produced by a PM prototype and its thermal behavior. In particular, the electric and magnetic fields, in the near field region in the frequency range 9kH…

Engineeringthermal behaviourField (physics)business.industryRenewable Energy Sustainability and the EnvironmentPhotovoltaic systemElectrical engineeringElectromagnetic compatibilityEnergy Engineering and Power TechnologyNear and far fieldrenewable sourseElectromagnetic compatibility (EMC)Power ModuleSmart gridEMIDistributed generationPower moduledistributed generation (DG)business
researchProduct

Un approccio semplificato per il calcolo del load flow nelle smart grids basato su misure distribuite in bassa tensione

2017

I sistemi di misura distribuiti sono alla base delle "smart distribution grids", ove la crescente presenza di generazione distribuita e sistemi di accumulo e la conseguente transizione verso sistemi attivi rendono necessarie funzionalità avanzate di monitoraggio, controllo e gestione delle reti. In tale contesto, un elemento essenziale è l'analisi dei flussi di potenza, che, com'è noto, può essere effettuata tramite algoritmi di load flow, noti il modello della rete e le potenze generate/assorbite nei vari nodi. Per la misura di tali grandezze sulla media tensione (MT), si possono utilizzare diversi strumenti (quali phasor measurement units, smart meters, power quality analyzers), che però …

Advanced metering infrastructure distributed measurement systems load flow power quality analyzer (PQA) power system measurements power system monitoring smart gridload flowsmart gridSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Sistema di misura per l’analisi spettrale di segnali non stazionari: implementazione in VHDL per lo sviluppo di un prototipo su FPGA

2010

Spectral analysis Chirp-Z Transform Arc Fault Circuit InterrupterSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Compensation of Nonlinearity of Voltage and Current Instrument Transformers

2019

This paper aims at characterizing and improving the metrological performances of current and voltage instrument transformers (CTs and VTs) in harmonic measurements in the power system. A theoretical analysis is carried out to demonstrate that, due to the iron core nonlinearity, CT and VT output signal is distorted even when the input signal is a pure sine wave. Starting from this analysis, a new method for CT and VT characterization and compensation is proposed. In a first step, they are characterized in sinusoidal conditions and the harmonic phasors of the distorted output are measured; in the second step, these phasors are used to compensate the harmonic phasors measured in normal operati…

uncertainty.Materials sciencepower system measurementAcousticsHarmonics020208 electrical & electronic engineeringPhasorHarmonicinstrument transformers (ITs)02 engineering and technologypower qualitySignalCurrent transformerCompensation (engineering)Harmonic analysisSine waveDistortion0202 electrical engineering electronic engineering information engineeringHarmonicElectrical and Electronic EngineeringuncertaintySettore ING-INF/07 - Misure Elettriche E ElettronicheInstrumentationIEEE Transactions on Instrumentation and Measurement
researchProduct

Uncertainty evaluation of a Backward/Forward Load Flow algorithm for a MV smart grid

2015

This paper presents the uncertainty evaluation of an innovative measurement algorithm for load flow analysis in MV distribution networks. The measurement procedure is based on Low Voltage (LV) load power measurements applied on a Backward/Forward (B/F) algorithm for the Load Flow (LF) resolution. Furthermore, in the procedure a three phase voltage measurement at the MV generating substation bus-bars is also considered. The accuracy analysis of the LF algorithm is performed in the case of a real load condition in the distribution grid of Ustica island, Italy. The analysis takes into account the uncertainty of the measurement instruments at the LV side of each secondary substation power trans…

Engineeringbusiness.industryPower system monitoringPower factorSmart gridAC powerLoad flow analysisPower quality analyzerConstant power circuitPower (physics)Settore ING-IND/33 - Sistemi Elettrici Per L'EnergiaPower system measurements load flow analysis power system monitoring smart grid power quality analyzer advanced metering infrastructureMeasurement uncertaintyAdvanced metering infrastructureVoltage regulationPower-flow studyPower system measurementsbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheLow voltageAlgorithm
researchProduct

A Monitoring and Management System for Energy Storage Integration in Smart Grids

2019

The integration of distributed storage systems (DSSs) at users and prosumers level can significantly contribute to energy efficiency and increase profits from renewable energy exploitation, thanks to suitable scheduling of charging and discharging periods. On the other hand, to preserve network stability and secure operation, Distribution Systems Operators (DSOs) are interested in DSSs control and cooperation with the grid. In this framework this work proposes a simple monitoring and management system for DSSs scheduling and its integration in a distributed measurement and control system architecture for smart grids. In the paper the proposed algorithm is tested on a simple case study at ho…

OptimizationEnergy storageSchedulingbusiness.industry020209 energyDistributed computing020208 electrical & electronic engineeringPSO02 engineering and technologyGridEnergy storageScheduling (computing)Distributed measurement systemSmart gridDistributed generationDistributed data storeManagement system0202 electrical engineering electronic engineering information engineeringMedicineDemande side responseDistributed generationbusinessSizingSettore ING-INF/07 - Misure Elettriche E ElettronicheEfficient energy use2019 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)
researchProduct

Uncertainty evaluation in load flow analysis: real MV distribution networks case studies

2018

This work investigates the measurement uncertainty impact on load flow analysis in medium voltage (MV) distribution networks. The considered algorithm is a simplified load flow algorithm (LFA), developed by authors, which is based on the load power measurements at each secondary substation and one voltage measurement at the slack bus (i.e. the voltage at the MV bus bars of the primary substation). In the viewpoint of a real implementation, to reduce monitoring system costs, the LFA makes use of low voltage (LV) load power measurements for all the substations except those of MV users, where MV transducers are usually already installed. The uncertainties on LFA input quantities (load powers a…

power system monitoringPower system measurementpower quality analyzers (PQA)load flow analysismart gridadvanced metering infrastructure (AMI)Settore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Caratterizzazione delle pinze amperometriche ad effetto hall in presenza di distorsione armonica

2009

current transducersSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

PQ Metrics Implementation on Low Cost Smart Metering Platforms. A Case Study Analysis

2018

The increasing interest on the quality of the energy supplied and generated in distribution networks is raising the need of distributed power quality (PQ) measurements. To allow such capabilities with cost effective metering solutions, this paper wants to investigate the feasibility of using smart meters, already installed for energy billing, also for power quality monitoring. To this aim, an electronic board (based on STCOMET metrology device), already used in many energy meters of different countries, has been selected as case study platform. The manufacturer firmware of this board was essentially aimed at implementing energy meter metrics and power line communications functionalities. In…

advanced metering infrastructuresmart meterFirmwareComputer sciencepower system measurement020209 energymedia_common.quotation_subject020208 electrical & electronic engineeringDistributed power02 engineering and technologypower qualitycomputer.software_genrepower system measurementsMetrologyReliability engineeringPower (physics)Electricity meter0202 electrical engineering electronic engineering information engineeringMetering modeQuality (business)smart gridcomputerSettore ING-INF/07 - Misure Elettriche E ElettronicheEnergy (signal processing)media_common
researchProduct

Power-Line Communication in Medium-Voltage System: Simulation Model and Onfield Experimental Tests

2012

The aim of this paper is to develop a complete model of a power-line communication (PLC) system operating on a medium-voltage (MV) network. The core-shield configuration was chosen for signal transmission in the power cables. In order to validate the developed model experimental, the medium-voltage network of the Favignana island was used to carry out detailed testing. The transmission was performed between two transformer substations in the presence of mains voltage (i.e., 24 kV). ST7540 FSK power-line transceivers, together with capacitive coupling interfaces, were used for the transmission and the reception of the communication signal. The correlation between the experimental measurement…

Capacitive couplingEngineeringFrequency-shift keyingmedium-voltage (MV) cablebusiness.industrypower-line communication (PLC)Electrical engineeringEnergy Engineering and Power TechnologyCommunications systemlaw.inventionpower system communicationPower-line communicationTransmission (telecommunications)lawElectronic engineeringElectrical and Electronic EngineeringTransceiverCommunication systemTransformerbusinessCommunication System Power System Communication Medium Voltage cable Power line communicationSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltageIEEE Transactions on Power Delivery
researchProduct

Narrowband power line communications for medium voltage smart grids

2014

The aim of the paper is to show how narrowband power line communications (NB-PLCs) can be a valid solution for medium voltage grids. Advantages and drawbacks of this solution are analyzed, starting from some experimental communication results, which were carried out on the medium power system networks of the islands of Ustica and Favignana, in the presence of the net voltage. Furthermore, some communication architectures and hardware prototypes based on NB-PLCs are proposed for different smart grids applications.

Engineeringbusiness.industrypower system measurements communication systems power system communication communication equipment testing narrow band power line communication smart gridsElectrical engineeringcommunication equipment testing communication systems narrow band power line communication power system communication power system measurements smart gridsLine (electrical engineering)Power (physics)Electric power systemSmart gridNarrowbandElectronic engineeringbusinessSettore ING-INF/07 - Misure Elettriche E ElettronichePhase-shift keyingVoltage
researchProduct

Critical issues and future prospects of the secondary substation in smart grid context

2014

This paper is focused on the new role of the secondary substation in the smart grids context. This innovative view has been proposed and developed in the framework of two Research Projects: NewCabELARC Project and Reipersei Project. The latter provides a concrete and comprehensive low cost solutions for the smart grid monitoring and control, allowing the real diffusion and integration of Distributed Generation and the full exploitation of Renewable Energy Sources. In this field, this paper shows how the secondary substation (SS) takes the role of smart transducer node where innovative devices can be located, collecting the measurement data coming from the field devices (power and energy met…

optic fiberEngineeringbusiness.industryNode (networking)Interface (computing)Electrical engineeringContext (language use)Smart gridSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciSmart transducerGridlaw.inventionSmart griddistribution networkslawDistributed generationpower line communication (PLC)Smart grids; secondary substation; power line communication (PLC); optic fiber; distribution networksSystems engineeringsecondary substationbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheRemote control2014 AEIT Annual Conference - From Research to Industry: The Need for a More Effective Technology Transfer (AEIT)
researchProduct

A novel approach to current transformer characterization in the presence of harmonic distortion

2009

The current transformer (CT) performance under distorted waveform conditions is usually characterized by means of the frequency-response test. In this paper, a new way to characterize CTs, closer to real operation conditions, is proposed. The harmonic phase-angle and ratio errors are measured using a nonsinusoidal current composed of fundamental and one harmonic with adjustable phase shift. The new method was tested by determining the performance of two metering class CTs commonly used by the Italian power company. The errors measured using the proposed approach are larger than the ones obtained with the frequency response. This result suggests that the frequency-response approach for the e…

EngineeringFrequency responseElectric current measurementAcousticsElectric transformer testingErrorsElectric utilitiesOperation conditionsHarmonic distortionPower companiesHarmonic analysisElectric power transmission networksFrequency responsePower electronicsWaveformMetering modeCurrent transformer (CT)Electrical and Electronic EngineeringInstrumentationNon-sinusoidal currentsPiezoelectric transducersTotal harmonic distortionbusiness.industryElectric power distributioncurrent transformer frequency response harmonic distortion power system harmonics transducersCurrent transformerRatio errorsTransducerElectric instrument transformersHarmonicPower system harmonicsCurrent (fluid)businessPower transmissionSettore ING-INF/07 - Misure Elettriche E ElettronicheDistorted waveforms
researchProduct

Comportamento dei trasformatori MT/BT in sistemi di comunicazione power line. Caratterizzazione e modellizzazione

2012

power line communication (PLC) attenuazione trasformatori
researchProduct

Simulation and laboratory experimental tests of a line to shield medium voltage power line communication system

2011

A complete model of a power-line communication (PLC) system on a medium-voltage (MV) network in the case of a line-shield configuration is presented in this paper. An MV cable model in a line-shield configuration is considered together with the power transformers, the signal coupling networks, and the receiving and transmitting line coupling interface of a ST7540 FSK power-line transceiver. Simulations of the complete model of the system under consideration have been carried out for different line lengths, with and without power transformers and derivation branches. The model is validated by experimental tests performed in the laboratory. The measured results confirm the reliability of the …

CouplingEngineeringFrequency-shift keyingbusiness.industryElectrical engineeringEnergy Engineering and Power TechnologyCommunications systemSignalLine (electrical engineering)Power-line communicationElectronic engineeringElectrical and Electronic EngineeringTransceiverbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltageCommunication system medium-voltage (MV) cable power-line communication power system communicationCommunication system; medium-voltage (MV) cable; power system communication; power-line communication
researchProduct

A PLC based monitoring and remote control architecture for Distributed Generation and Storage systems in LV smart grids

2021

(Abstract) This paper proposes a new power line communication (PLC) architecture for monitoring and remote control of Distributed Generators (DG) and Energy Storage Systems (ESS) connected to low voltage distribution networks. The final aim is to improve the performance of the PLC link in terms of robustness and efficiency in devices addressing. The proposed solution is based on a concentrator, to be installed in secondary substation, and a new PLC bridge, to be linked both to inverters and interface protection systems of DGs or ESSs. In this way, a communication link is obtained between distribution system operator (DSO) and DG or ESS owners. The proposed system is able to provide advanced…

business.industryComputer scienceInterface (computing)Electrical engineeringConcentratorlaw.inventionPower-line communicationSmart gridRobustness (computer science)lawDistributed generationInverterbusinessRemote control2021 IEEE 6th International Forum on Research and Technology for Society and Industry (RTSI)
researchProduct

Development of a Coupling System for Medium Voltage Power Line Communication in the CENELEC A Frequency Band

2016

In this paper the performances of a new power line communication (PLC) coupling system for medium voltage (MV) smart grids are investigated in the CENELEC A frequency band (i.e. 3 - 95 kHz). The new coupling solution is based on the use of the capacitive divider of the voltage detecting system (VDS) as PLC coupler to the MV network. According to IEC 61243-5, VDS are worldwide used to reveal the presence of the mains voltage to ensure the safety of the operators. A proper interface circuit has been invented and patented to couple the PLC signal through the VDS. In this way no dedicated MV PLC coupler is required, thus avoiding the related costs of the coupler, of its installation, and those …

Engineeringpower system measurementFrequency band020209 energy02 engineering and technologyCapacitanceSignalCommunication systemspower system communication0202 electrical engineering electronic engineering information engineeringElectronic engineeringsmart gridscommunication signal couplersCouplingFrequency-shift keyingbusiness.industry020208 electrical & electronic engineeringElectrical engineeringnarrow band power line communicationpower system measurementsPower-line communicationSmart gridcommunication systemcommunication signal couplerbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltage
researchProduct

Measurement of Simplified Single- And Three-Phase Parameters for Harmonic Emission Assessment Based on IEEE 1459-2010

2021

This article investigates the feasibility of using a simplified approach, based on the measurement of power ratio parameters, for harmonic emissions assessment at the point of common coupling (PCC). The proposed approach comes from the common concept of power factor correction and the definitions of the IEEE Std. 1459-2010, where line utilization and harmonic pollution levels are evaluated by means of ratios between the power quantities of the apparent power decomposition. In addition to the IEEE Std. 1459–2010 indicators, in this article, the behavior is studied of additional parameters that are conceptually similar to those defined by the IEEE Std. 1459-2010. The suitability of such param…

Computer sciencepower measurement02 engineering and technologyPower factorHarmonic distortionlaw.inventionHarmonic analysisElectric power systemControl theorylawpower definitions0202 electrical engineering electronic engineering information engineeringElectrical and Electronic EngineeringInstrumentationuncertainty analysisIEEE Std. 1459-2010020208 electrical & electronic engineeringharmonic emissionAC powerpower qualityPower (physics)CapacitorThree-phaseHarmonicharmonic analysisparameter estimationSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Rogowski coil current transducer compensation method for harmonic active power error

2015

Abstract In the harmonic active power measurement, the highest uncertainties are generally introduced by the current and voltage transducers. In a previous paper, the authors showed that the current transformer (CT) can introduce significant errors in such measurement, especially if the phase shift between voltage and current is close to ±90°. In such condition the errors on harmonic power measurement are mainly due to the CT phase displacement. This paper shows that better results can be achieved with more linear transducers, such as the Rogowski coil current transducers (RCCTs), whose metrological performance in distorted condition can be improved, by means of a proper compensation method…

Frequency responseEngineeringbusiness.industryApplied MathematicsAcousticsPower system harmonics Transducers Current transformers. Frequency response Power measurement Rogowski coilTransducersElectrical engineeringAC powerCondensed Matter PhysicsCurrent transformerRogowski coilCompensation (engineering)Power (physics)Current transformersFrequency responseHarmonicPower system harmonicsElectrical and Electronic EngineeringPower measurementbusinessInstrumentationSettore ING-INF/07 - Misure Elettriche E ElettronicheRogowski coilVoltage
researchProduct

A new PLC-based smart metering architecture for medium/low voltage grids: Feasibility and experimental characterization

2018

Abstract This paper investigates the feasibility of a smart metering architecture for modern power grids in the smart cities framework. A particular focus is made on Automatic Meter Reading, with the aim of facing some costs and safety drawbacks of current solutions (such as dependence from wireless communication providers, reliability problems in bad weather conditions, and exposition to cyber-attacks). The proposed architecture exploits power line communications (PLC) at both low and medium voltage level, thanks to new devices and an innovative medium voltage PLC coupling system. The new coupling solution and the whole smart metering architecture are experimentally verified in a wide freq…

Computer science020209 energySmart grid02 engineering and technologyPower line communicationReliability (semiconductor)Automatic Meter Reading0202 electrical engineering electronic engineering information engineeringElectronic engineeringWirelessMetering modeElectrical and Electronic EngineeringInstrumentationDistributed measurement systemsbusiness.industryApplied Mathematics020208 electrical & electronic engineeringSmart gridsPower systems communicationCondensed Matter PhysicsDistributed measurement systemPower-line communicationSmart gridSmart meteringbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheLow voltageAutomatic meter readingVoltageMeasurement
researchProduct

An Innovative Power Line Communication solution For Medium Voltage Smart Grids Applications

2018

This paper summarizes the authors research activity concerning the design, modeling and experimental characterization of a new coupling system for medium voltage (MV) narrow band power line communications (NB-PLC). The proposed solution has been patented by authors and it exploits the capacitive divider of voltage detecting systems (VDSs) normally used to reveal the mains voltage presence, thus avoiding the use of dedicated MV couplers. In the following, the modeling of the VDS capacitive divider is presented and the interface card design is described, based on simulation of the whole PLC transmission channel. Laboratory tests are also presented. Finally, the results are shown of an on-fiel…

power line communicationspower system measurementcommunication system performancePower system communicationsmart gridnarrow band power line communicationSettore ING-INF/07 - Misure Elettriche E Elettronichecommunication equipment testing
researchProduct

A Virtual Tool for Load Flow Analysis in a Micro-Grid

2020

This paper proposes a virtual tool for load flow analysis in energy distribution systems of micro-grids. The solution is based on a low-cost measurement architecture, which entails low-voltage power measurements in each secondary substation and a voltage measurement at the beginning of the medium voltage (MV) feeder. The proposed virtual tool periodically queries these instruments to acquire the measurements. Then, it implements a backward&ndash

Control and OptimizationComputer scienceEnergy Engineering and Power Technologylcsh:TechnologyElectric power systemDistributed generatorPower-flow studyElectrical and Electronic Engineeringsmart gridEngineering (miscellaneous)Simulationdistributed generationRenewable Energy Sustainability and the Environmentbusiness.industrylcsh:TMicro gridPower (physics)Smart gridpower systemFlow (mathematics)Distributed generationload flowNode (circuits)micro-gridmeasurement uncertaintiesbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheEnergy (miscellaneous)Voltage
researchProduct

Incremental heuristic approach for meter placement in radial distribution systems

2019

The evolution of modern power distribution systems into smart grids requires the development of dedicated state estimation (SE) algorithms for real-time identification of the overall system state variables. This paper proposes a strategy to evaluate the minimum number and best position of power injection meters in radial distribution systems for SE purposes. Measurement points are identified with the aim of reducing uncertainty in branch power flow estimations. An incremental heuristic meter placement (IHMP) approach is proposed to select the locations and total number of power measurements. The meter placement procedure was implemented for a backward/forward load flow algorithm proposed by…

Mathematical optimizationControl and OptimizationComputer scienceHeuristic (computer science)020209 energyOptimal meter placementEnergy Engineering and Power Technology02 engineering and technologySmart gridlcsh:Technology0202 electrical engineering electronic engineering information engineeringMetrePower-flow studyInstrumentation (computer programming)Electrical and Electronic EngineeringEngineering (miscellaneous)optimal meter placement; smart grid; load flow analysis; Monte Carlo methodsRenewable Energy Sustainability and the Environmentlcsh:T020208 electrical & electronic engineeringMonte Carlo methodsLoad flow analysisPower (physics)Monte Carlo methodSmart gridLoad flow analysiSettore ING-INF/07 - Misure Elettriche E ElettronicheEnergy (miscellaneous)
researchProduct

Measurement Uncertainty of Harmonic Emission Indicators based on IEEE Std. 1459-2010

2020

The study presented in this paper is aimed at analyzing the measurement uncertainty impact on the evaluation of some power ratio parameters for harmonic emissions assessment based on IEEE Std. 1459-2010 apparent power decomposition. In addition to power factors for line utilization and harmonic pollution levels evaluation defined in the Standard, the study covers also some new parameters, which have been introduced by the authors as IEEE Std. 1459-2010 power quantities ratios. The measurement of the aforesaid parameters is implemented on a PC-based wattmeter, in order to investigate the measurement uncertainty impact on the evaluation of the power ratios. The obtained results show that, in …

Measurement uncertaintypower measurement02 engineering and technology01 natural scienceslaw.inventionlaw0202 electrical engineering electronic engineering information engineeringpollutionMedicineuncertainty analysisIEEE Std. 1459-2010Total harmonic distortionbusiness.industry020208 electrical & electronic engineering010401 analytical chemistryWattmeterpower qualityAC power0104 chemical sciencesReliability engineeringPower (physics)harmonic distortionPower definitionsHarmonic pollutionPower ratioharmonic analysisHarmonicMeasurement uncertaintybusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheHarmonic sources2020 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)
researchProduct

Design of a Time Dissemination System Using Chirp Modulation for Medium Voltage Smart Grid Applications

2020

The monitoring and the management of smart grid require an advanced communication infrastructure. The time synchronization is among the most important services such an infrastructure should offer. Several solutions are available to disseminate the time information in a distributed system; for instance, most of the times a global positioning system (GPS) receiver is used to recover accurate time information. However, GPS receivers need a clear view of the sky. Other solutions, like the use of a network-based synchronization mechanism, require a dedicated communication infrastructure, which is not always feasible for economical reason. Thus, the use of the power grid itself to disseminate a t…

Computer scienceTime signal02 engineering and technologyIRIG-BSynchronizationChirp modulation IRIG-B medium voltage (MV) distribution grid smart grid time synchronization0202 electrical engineering electronic engineering information engineeringChirpElectronic engineeringElectrical and Electronic Engineeringsmart gridtime synchronizationChirp modulationmedium voltage (MV) distribution gridInstrumentationDisseminationJitterbusiness.industry020208 electrical & electronic engineeringFrame (networking)GridPower-line communicationSmart gridModulationGlobal Positioning SystembusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheIEEE Transactions on Instrumentation and Measurement
researchProduct

Oil filled MV/LV Power Transformer Behavior in Narrow Band Power Line Communication Systems

2012

The aim of this paper is to characterize oil-filled power transformers in the narrow-band power-line communication (PLC) frequency range of 50-150 kHz. A new model is proposed for such type of a transformer, in the aforementioned frequency range of interest, in order to study its influence on the signal transmission and to investigate the possibility that the PLC signal can cross the power transformer itself. The new model is simpler than those previously proposed in literature, and it can be used in the whole frequency range available for NB PLC according to the CENELEC EN 50065-1 A-band. In order to validate the model, simulation and measurement results are compared for four oil-filled po…

EngineeringFrequency-shift keyingbusiness.industryOverhead power lineElectrical engineeringAttenuation communication equipment testing communication systems narrow-band power-line communication (NB-PLC) power system communication power transformersCommunications systemlaw.inventionpower transformerspower system communicationnarrow-band power-line communicationPower-line communicationPower ratinglawElectromagnetic coilElectronic engineeringElectrical and Electronic EngineeringbusinessTransformerInstrumentationLow voltageSettore ING-INF/07 - Misure Elettriche E Elettronichecommunication equipment testing
researchProduct

New Measurement Procedure for Load Flow Evaluation in Medium Voltage Smart Grids

2013

The aim of this paper is to present a new approach for the medium voltage (MV) distribution network load flow analysis, mainly based on power measurement at the low voltage (LV) level of MV/LV distribution substations. This allows to use measurement instruments, usually already installed in the secondary substations, thus achieving an equally reliable measurement system with a lower cost compared to measurements at the MV side. The new approach can be applied using a proper communication system to collect the nodal measurements and an iterative algorithm based on ladder iterative technique (LIT) to compute the load flow. The validity of this method is presented and discussed on the basis of…

EngineeringIterative methodbusiness.industrypower system measurementSystem of measurementSmart grid (SG) power system measurements load flow power quality analyzer (PQA) state estimation (SE) advanced metering infrastructure (AMI)substations.Communications systemautomatic meter readingpower distribution reliabilityPower (physics)Settore ING-IND/33 - Sistemi Elettrici Per L'Energiasmart power gridsSmart gridElectronic engineeringload flowiterative methodsPower-flow studybusinessLow voltageSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltagepower system state estimation
researchProduct

Implementation of a PLC Field Analyzer on a G3 Modem Platform

2021

Nowadays, power line communications (PLC) are a widely used technology in distribution grids, both for automatic meter reading and automation applications. PLC performances (in terms of capacity, coverage, robustness, and data transmission rate) can be significantly affected by electrical network topologies, connected loads and disturbances. Thus, utilities and modem manufacturers are increasing their interest in electrical network characterization. In this framework, a software tool is proposed in this paper to measure received signal and noise levels. As case study, it is implemented on a G3 PLC transceiver, widely used for smart metering purposes. In this way, a PLC channel characterizat…

business.industryFirmwarecomputer.software_genreNetwork topologyCommunication signal communication systems power line communication Power system communication power system measurements smart gridslaw.inventionTransmission (telecommunications)lawElectrical networkMedicineTransceiverbusinesscomputerSettore ING-INF/07 - Misure Elettriche E ElettronicheComputer hardwareAutomatic meter readingCommunication channelData transmission
researchProduct

Secondary substation power line communications for medium voltage smart grids

2012

In this paper a performance analysis is carried out, in order to evaluate the possibility to employ power line communication (PLC) between secondary substations of a medium voltage (MV) distribution networks in a smart grid. The study is focused on the analysis of PLC technologies and the evaluation of the influence quantities on the communication performance in the most common case of by-pass connection at MV bus-bars of secondary substations. Different quantities have been analyzed as modulation techniques, requested bandwidth and bitrate, coupling device and system attenuation versus frequency in order to find the best solution for a reliable communication system. A complete model of a r…

EngineeringElectric power distributionBusbarbusiness.industryPower Line Communication (PLC)Bandwidth (signal processing)active networksElectrical engineeringCommunications systempower system communicationPower-line communicationElectric power transmissionSmart griddistribution networksElectronic engineeringsmart gridsPower Line Communication (PLC) smart grids active networks power system communication distribution networksbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheActive networking
researchProduct

Measurement and communication interfaces for distributed generation in smart grids

2013

The aim of this work is to perform a feasibility study on the measurement and communication strategies for the development of a new generation of interface devices for distributed generators and their integration on smart grids. The communication system can use one or more technologies, at the various levels, creating a low cost network infrastructure, in the framework of a SCADA (Supervisory Control and Data Acquisition) architecture. As regards the measurements, the attention is focused on the anti-islanding protection, based on a hybrid solution, which makes use of local measurements and communications with the grid, at both MV and LV level by employing the PLC technology. Some simulatio…

power line communicationEngineeringdistributed generationbusiness.industrydistributed generation interface devices smart grids power system communications power line communication islanding detectionInterface (computing)Programmable logic controllerCommunications systemGridpower system communicationsinterface devicesSmart gridSCADAEmbedded systemDistributed generationsmart grids.islanding detectionArchitecturebusinessSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Characterization of Current Transformers in the Presence of Harmonic Distortion

2008

The CTs performance under distorted conditions are usually characterized by means of the frequency response test. In this paper a new way to characterize CTs, closer to real operative conditions, is proposed. The harmonic phase angle and ratio errors are measured when the CTs are excited with a nonsinusoidal current composed of a fundamental and one harmonic, with adjustable phase shift. The errors measured using the new approach were found larger than the ones obtained with the frequency response. This suggests that frequency response is not a reliable method to evaluate the CT performance under distorted conditions.

PhysicsFrequency responseTotal harmonic distortionTransducerAcousticsExcited stateHarmonicHarmonic phaseCurrent transformerCharacterization (materials science)
researchProduct

Campagna di misure sulla rete elettrica dell’isola di Favignana per la caratterizzazione di reti di accoppiamento per la trasmissione di segnali su c…

2010

Medium Voltage Network Power Line Communication Coupling NetworksSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Un campione di potenza basato su schede di acquisizione commerciali. Prove sperimentali e valutazione dell'incertezza

2011

schede di acquisizione dati pc-based instruments misure di potenza incertezza di misura campioni
researchProduct

Measurements methodology for the reliability evaluation of intelligent power modules

2014

The paper describes a measurement methodology for the reliability evaluation of new intelligent power electronics modules (IPMs). In particular, the evaluation of the IPMs immunity to radio frequency conducted disturbances has been performed, at different operating thermal conditions, designing a suitable measurement set up in a shielded room. Moreover, the thermal performances of the devices have been analyzed, setting up a proper experimental test bench. The measurements procedures are detailed described. © 2014 IEEE.

Electromagnetic compatibility (EMC)Engineeringbusiness.industryPower moduleEMCintegrated power electronic modulesControl engineeringbusinessSettore ING-INF/07 - Misure Elettriche E Elettronicheelectrothermal effectReliability (statistics)Reliability engineering
researchProduct

Problematiche di misura della potenza attiva armonica

2007

researchProduct