0000000000594822
AUTHOR
Giorgio Fallica
PPG/ECG Multisite Combo System Based on SiPM Technology
Two versions of a PPG/ECG combined system have been realized and tested. In a first version a multisite system has been equipped by integrating 3 PPG optodes and 3 ECG leads, whereas in another setup a portable version has been carried out. Both versions have been realized by equipping the optical probes with SiPM detectors. SiPM technology is expected to bring relevant advantages in PPG systems and overcome the limitations of physiological information extracted by state of the art PPG, such as poor sensitivity of detectors used for backscattered light detection and motion artifacts seriously affecting the measurements repeatability and pulse waveform stability. This contribution presents t…
Signal to Noise Ratio of Silicon Photomultipliers measured in the Continuous Wave Regime
We performed a Signal to Noise Ratio characterization, in the continuous wave regime, at different bias voltages, frequencies and temperatures, on a novel class of silicon photomultipliers fabricated in planar technology on silicon p-type substrate. Signal to Noise Ratio has been measured as the ratio of the photogenerated current, filtered and averaged by a lock-in amplifier, and the Root Mean Square deviation of the overall current flowing to the device. The measured noise takes into account the shot noise, resulting from the photocurrent and the dark current. We have also performed a comparison between our SiPMs and a photomultiplier tube in terms of Signal to Noise Ratio, as a function …
Responsivity measurements of silicon carbide Schottky photodiodes in the UV range
We report on the design and the electro-optical characterization of new classes of 4H-SiC Schottky UV detectors, fabricated employing Ni 2 Si interdigitated strips. We have measured, in dark conditions, the forward and reverse I-V characteristics as a function of temperature and C-V characteristics. Responsivity measurements of the devices, as function of wavelength in the UV range, of package temperature and of applied reverse bias are reported. We also compared devices featuring different strip pitch sizes, discussing their performances, and found the device exhibiting best results.
Low invasive multisensor acquisition system for real-time monitoring of cardiovascular and respiratory parameters
The recent advances in multiparametric monitoring of biosignals and management of big data prompt for the development of devices and techniques for the extraction of indicators with physiological relevance. In this context, we have designed and realized a portable electronic system, equipped with simple biomedical sensors, able to synchronously record multiple electrocardiographic (ECG), photoplethysmographic (PPG) and breathing signals, for carrying out a non-invasive monitoring of several cardiovascular parameters. In this work, we show the results of preliminary measurements performed following a specific physiological protocol (i.e., deep breathing with 10 s per cycle). The system allow…
Extensive electrical model of large area silicon photomultipliers
Abstract In this paper the full electrical model of silicon photomultipliers fabricated at STMicroelectronics Catania R&D clean room facilities is presented. An accurate investigation on both SiPM single microcell and entire SiPM structure to extrapolate all the electrical elements has been executed by means of dedicated characterizations carried out on appropriate layout structure. The electrical simulations results are compared to the experimental data showing a good fit and therefore verifying the accuracy of the proposed model. This model can be used to describe all the SiPMs with different sizes manufactured using the same technology. Moreover, starting from this extensive electrical m…
Silicon Photomultipliers Signal-to-Noise Ratio in the Continuous Wave Regime
Abstract— We report on Signal-to-Noise Ratio measurements carried out, in the continuous wave regime, at different bias voltages, frequencies and temperatures, on a class of silicon photomultipliers fabricated in planar technology on silicon p- type substrate. Signal-to-Noise Ratio has been measured as the ratio of the photogenerated current, filtered and averaged by a lock-in amplifier, and the Root Mean Square deviation of the same current. The measured noise takes into account the shot noise, resulting from the photocurrent and the dark current. We have also performed a comparison between our SiPMs and a photomultiplier tube in terms of Signal-to-Noise Ratio, as a function of the tempe…
Measurements of Silicon Photomultipliers Responsivity in Continuous Wave Regime
We report on the electrical and optical characterization, in continuous wave regime, of a novel class of silicon photomultipliers fabricated in standard planar technology on a silicon p-type substrate. Responsivity measurements, performed with an incident optical power down to tenths of picowatts, at different reverse bias voltages and on a broad (340–820 nm) spectrum, will be shown and discussed. The device temperature was monitored, allowing us to give a physical interpretation of the measurements. The obtained results demonstrate that such novel silicon photomultipliers are suitable as sensitive power meters for low photon fluxes.
Electro-optical characterization of new classes of Silicon Carbide UV photodetectors
In this paper, we present the fabrication process steps and the characterization of 4H-SiC vertical Schottky UV detectors, where interdigitated strips, acting as top metal contacts, have been realized in $\hbox{Ni}_{2}\hbox{Si}$ . These devices exploit the pinch-off surface effect. $I$ – $V$ and $C$ – $V$ characteristics, as functions of temperature, were measured in dark conditions. In addition, we have carried out responsivity measurements, for wavelengths ranging from 200 to 400 nm, at varying package temperature and applied reverse bias. A comparison among devices having different strip pitch sizes has been performed, thus finding out that the 10- $\mu\hbox{m}$ pitch class demonstrates …
SNR measurements of silicon photomultipliers in the continuous wave regime
We report on our Signal-to-Noise Ratio (SNR) measurements carried out, in the continuous wave regime, at different frequencies and at various temperatures, on a novel class of silicon photomultipliers (SiPMs) fabricated in planar technology on silicon p-type substrate. SNR of SiPMs is given by the ratio of the photogenerated current, filtered and averaged by a lock-in amplifier, and the Root Mean Square (RMS) deviation of the same current. In our measurements, we have employed a 10 Hz equivalent noise bandwidth, around the lock-in amplifier reference frequency. The measured noise takes into account the shot noise, resulting from the photocurrent and the dark current, while background light …
CY5 fluorescence measured with silicon photomultipliers
This paper presents an efficient optical biosensor set up for a low-level light detection, using fluorescent dyes and a novel Si-based detector. Fluorescence emitted by a traditional fluorophore, CY5, widely used as optical label in DNA microarrays, was detected using a 25 pixels Silicon photomultiplier (SiPM), a device formed by avalanche diodes operating in Geiger mode, in parallel connections. We measured the fluorescence current in different deposition (fluorophore concentration; solvent; salt concentration) and operation (angle of analysis, optical laser power, device gain) conditions. The characterization of DNA samples labeled with CY5 is also reported to demonstrate the detector pot…
Ostruzione polmonare ed aritmia respiratoria
Il monitoraggio di pazienti tramite segnali fotopletismografici (PhotoPlethysmoGram, PPG) acquisiti sul polso, arteria radiale, piuttosto che sulla punta dell’indice, permette di ottenere un segnale più stabile e con maggiori informazioni, come la gittata cardiaca, la durata della contrazione ventricolare e la chiusura dell’aorta. In questo lavoro è presentata un’attività preliminare per rilevare condizioni come l’ostruzione polmonare e le apnee notturne. Si è indagato l’andamento dell’aritmia respiratoria in relazione ad eventuali difficoltà respiratorie. Per il momento ci si è limitati ad osservare soggetti sani e l’ostruzione è stata simulata facendo respirare i soggetti attraverso una c…
Physiological parameters measurements in a cardiac cycle via a combo PPG-ECG system
In this paper, we present an innovative way to measure some physiological parameters (such as the pre-ejection period, the pulse transit time, the blood pressure) in a cardiac cycle. A combo PPG-ECG system has been developed and employed to extract both the ECG signal from standard limb leads and simultaneously the photoplethysmography signal from the wrist and the forearm, to calculate the pre-ejection period. This system represents an easy and non-invasive technique to determine these biomedical parameters without using expensive impedance cardiography equipment.