0000000000772459
AUTHOR
D. Agrò
PPG embedded system for blood pressure monitoring
In this work, we have designed and implemented a microcontroller-based embedded system for blood pressure monitoring through a PhotoPlethysmoGraphic (PPG) technique. In our system, it is possible to perform PPG measurements via reflectance mode. Hardware novelty of our system consists in the adoption of Silicon PhotoMultiplier detectors. The signal received from the photodetector is used to calculate the instantaneous heart rate and therefore the heart rate variability. The obtained results show that, by using our system, it is possible to easily extract both the PPG and the breath signal. These signals can be used to monitor the patients during the convalescence both in hospital and at hom…
Signal to Noise Ratio of Silicon Photomultipliers measured in the Continuous Wave Regime
We performed a Signal to Noise Ratio characterization, in the continuous wave regime, at different bias voltages, frequencies and temperatures, on a novel class of silicon photomultipliers fabricated in planar technology on silicon p-type substrate. Signal to Noise Ratio has been measured as the ratio of the photogenerated current, filtered and averaged by a lock-in amplifier, and the Root Mean Square deviation of the overall current flowing to the device. The measured noise takes into account the shot noise, resulting from the photocurrent and the dark current. We have also performed a comparison between our SiPMs and a photomultiplier tube in terms of Signal to Noise Ratio, as a function …
Responsivity measurements of silicon carbide Schottky photodiodes in the UV range
We report on the design and the electro-optical characterization of new classes of 4H-SiC Schottky UV detectors, fabricated employing Ni 2 Si interdigitated strips. We have measured, in dark conditions, the forward and reverse I-V characteristics as a function of temperature and C-V characteristics. Responsivity measurements of the devices, as function of wavelength in the UV range, of package temperature and of applied reverse bias are reported. We also compared devices featuring different strip pitch sizes, discussing their performances, and found the device exhibiting best results.
Design and realization of a portable multichannel continuous wave fNIRS
A design and implementation of a portable functional Near InfraRed Spectroscopy embedded system prototype is described. In this theoretical and experimental work, we present an embedded system hosting 64 LED sources and 128 Silicon PhotoMultiplier detectors (SiPM). The elementary part of the structure is a flexible probe “leaf” consisting of 16 SiPMs, 4 couples of LEDs, each operating at two wavelengths, and a temperature sensor. The hardware system is based on an ARM main microcontroller that allows to perform both the switching time of LEDs and the acquisition of the SiPM outputs. The performed preliminary experimental tests achieved very promising results, thus demonstrating the effectiv…
Design and development of a fNIRS system prototype based on SiPM detectors
Functional Near Infrared Spectroscopy (fNIRS) uses near infrared sources and detectors to measure changes in absorption due to neurovascular dynamics in response to brain activation. The use of Silicon Photomultipliers (SiPMs) in a fNIRS system has been estimated potentially able to increase the spatial resolution. Dedicated SiPM sensors have been designed and fabricated by using an optimized process. Electrical and optical characterizations are presented. The design and implementation of a portable fNIRS embedded system, hosting up to 64 IR-LED sources and 128 SiPM sensors, has been carried out. The system has been based on a scalable architecture whose elementary leaf is a flexible board …
Design and implementation of a portable fNIRS embedded system
We report on the design, development and operation of a portable, low cost, battery-operated, multi-channel, functional Near Infrared Spectroscopy embedded system, hosting up to 64 optical sources and 128 Silicon PhotoMultiplier optical detectors. The system is realized as a scalable architecture, whose elementary leaf consists of a probe board provided with 16 SiPMs, 4 couples of bi-color LED, and a temperature sensor, built on a flexible stand. The hardware structure is very versatile because it is possible to handle both the switching time of the LED and the acquisition of the photodetectors, via an ARM based microcontroller.
Responsivity measurements of 4H-SiC Schottky photodiodes for UV light monitoring
We report on the design and the electro-optical characterization of a novel class of 4H-SiC vertical Schottky UV detectors, based on the pinch-off surface effect and obtained employing Ni2Si interdigitated strips. We have measured, in dark conditions, the forward and reverse I–V characteristics as a function of the temperature and the C–V characteristics. Responsivity measurements of the devices, as a function of the wavelength (in the 200 – 400 nm range), of the package temperature and of the applied reverse bias are reported. We compared devices featured by different strip pitch size, and found that the 10 μm device pitch exhibits the best results, being the best compromise in terms of fu…
Brain Monitoring Via an Innovative CW-FNIRS System
Functional Near InfraRed Spectroscopy (fNIRS) is an imaging technique mainly devoted to human brain monitoring. It is used as a non-invasive technique, in medical field, in order to measure the oxygen concentration of blood. This because the relatively good transparency of biological materials in the near infrared allows sufficient photon transmission through tissues. Within the so-called fNIRS range (650-900 nm), the main absorbers are blood chromophores, in particular the oxygenated and deoxygenated haemoglobin (HbO2 and Hb, respectively). When two or more wavelengths are used, changes of such chromophores can be computed by employing the modified Beer-Lambert law, thus providing importan…
Responsivity measurements of N-on-P and P-on-N silicon photomultipliers in the continuous wave regime
We report the electrical and optical comparison, in continuous wave regime, of two novel classes of silicon photomultipliers (SiPMs) fabricated in planar technology on silicon P-type and N-type substrate respectively. Responsivity measurements have been performed with an incident optical power from tenths of picowatts to hundreds of nanowatts and on a broad spectrum, ranging from ultraviolet to near infrared (340-820 nm). For both classes of investigated SiPMs, responsivity shows flat response versus the optical incident power, when a preset overvoltage and wavelength is applied . More in detail, this linear behavior extends up to about 10 nW for lower overvoltages, while a shrink is observ…
Silicon Photomultipliers Signal-to-Noise Ratio in the Continuous Wave Regime
Abstract— We report on Signal-to-Noise Ratio measurements carried out, in the continuous wave regime, at different bias voltages, frequencies and temperatures, on a class of silicon photomultipliers fabricated in planar technology on silicon p- type substrate. Signal-to-Noise Ratio has been measured as the ratio of the photogenerated current, filtered and averaged by a lock-in amplifier, and the Root Mean Square deviation of the same current. The measured noise takes into account the shot noise, resulting from the photocurrent and the dark current. We have also performed a comparison between our SiPMs and a photomultiplier tube in terms of Signal-to-Noise Ratio, as a function of the tempe…
Design and realization of a portable continuous wave fNIRS
A design and implementation of a portable functional Near InfraRed Spectroscopy embedded system prototype is described. In this theoretical and experimental work, we present an embedded system hosting 64 LED sources and 128 Silicon PhotoMultiplier detectors (SiPM). The elementary part of the structure is a flexible probe “leaf” consisting of 16 SiPMs, 4 couples of LEDs, each operating at two wavelengths, and a temperature sensor. The hardware system is based on an ARM main microcontroller that allows to perform both the switching time of LEDs and the acquisition of the SiPM outputs. The performed preliminary experimental tests achieved very promising results, thus demonstrating the effectiv…
Measurements of Silicon Photomultipliers Responsivity in Continuous Wave Regime
We report on the electrical and optical characterization, in continuous wave regime, of a novel class of silicon photomultipliers fabricated in standard planar technology on a silicon p-type substrate. Responsivity measurements, performed with an incident optical power down to tenths of picowatts, at different reverse bias voltages and on a broad (340–820 nm) spectrum, will be shown and discussed. The device temperature was monitored, allowing us to give a physical interpretation of the measurements. The obtained results demonstrate that such novel silicon photomultipliers are suitable as sensitive power meters for low photon fluxes.
Electro-optical characterization of new classes of Silicon Carbide UV photodetectors
In this paper, we present the fabrication process steps and the characterization of 4H-SiC vertical Schottky UV detectors, where interdigitated strips, acting as top metal contacts, have been realized in $\hbox{Ni}_{2}\hbox{Si}$ . These devices exploit the pinch-off surface effect. $I$ – $V$ and $C$ – $V$ characteristics, as functions of temperature, were measured in dark conditions. In addition, we have carried out responsivity measurements, for wavelengths ranging from 200 to 400 nm, at varying package temperature and applied reverse bias. A comparison among devices having different strip pitch sizes has been performed, thus finding out that the 10- $\mu\hbox{m}$ pitch class demonstrates …
Electrochemical Conversion of Dichloroacetic Acid to Chloroacetic Acid in Conventional Cell and in Two Microfluidic Reactors
The electrochemical conversion of dichloroacetic acid to chloracetic acid is investigated in conventional cells and in microreactors. Two different microreactors are used: the first is a filter press cell equipped with PTFE micrometric spacers, easy to assemble and disassemble and available for a large variety of electrodes and solvents; the second is made using an adhesive spacer, micromilling and press and could easily be developed on an industrial scale. The electrochemical synthesis is performed successfully in the microreactors equipped with a graphite cathode under proper operative conditions. The performance of the process strongly depends on the nature of the cathode and, for micror…
SNR measurements of silicon photomultipliers in the continuous wave regime
We report on our Signal-to-Noise Ratio (SNR) measurements carried out, in the continuous wave regime, at different frequencies and at various temperatures, on a novel class of silicon photomultipliers (SiPMs) fabricated in planar technology on silicon p-type substrate. SNR of SiPMs is given by the ratio of the photogenerated current, filtered and averaged by a lock-in amplifier, and the Root Mean Square (RMS) deviation of the same current. In our measurements, we have employed a 10 Hz equivalent noise bandwidth, around the lock-in amplifier reference frequency. The measured noise takes into account the shot noise, resulting from the photocurrent and the dark current, while background light …