6533b7d8fe1ef96bd126adcb

RESEARCH PRODUCT

Progression of emphysema evaluated by MRI using hyperpolarized 3he (hp 3he) measurements in patients with alpha-1-antitrypsin (a1at) deficiency compared with CT and lung function tests

Asger DirksenLaura M. SchreiberM. BatzTrine StavngaardL. Vejby Søgaard

subject

MalePercentileAlpha (ethology)Pilot ProjectsHeliumPulmonary function testingIsotopesmedicineHumansEffective diffusion coefficientRadiology Nuclear Medicine and imagingReproducibilityLungRadiological and Ultrasound Technologymedicine.diagnostic_testbusiness.industryRespiratory diseaseReproducibility of ResultsMagnetic resonance imagingGeneral MedicineMiddle Agedmedicine.diseaseMagnetic Resonance ImagingRespiratory Function Testsmedicine.anatomical_structurePulmonary EmphysemaDisease ProgressionRegression AnalysisFemaleTomography X-Ray ComputedbusinessNuclear medicine

description

Background: The progression of emphysema is traditionally measured by pulmonary function test, with forced expiratory volume in 1 s (FEV1) being the most accepted and used measurement. However, FEV1 is insensitive in detecting mild/slow progression of emphysema because of low reproducibility as compared to yearly decline. Purpose: To investigate the progression of emphysema over a period of 2 years using diffusion-weighted hyperpolarized (HP) 3He magnetic resonance imaging (MRI) in patients with alpha-1-antitrypsin (A1AT) deficiency. Material and Methods: Nine patients with severe A1AT deficiency were studied over a period of 2 years (baseline, year 1, and year 2) with HP 3He MRI using apparent diffusion coefficient (ADC), lung function tests (FEV1 and carbon monoxide lung diffusion capacity [DL,CO]), and computed tomography (CT) using densitometric parameters (15th percentile density [CT-PD15] and relative area of emphysema below -910 HU [CT-RA-910]). Results: Seven patients were scanned three times, one patient two times, and one patient only at baseline. The mean increase in ADC values from first to last HP 3He MR scanning was 3.8% (0.014 cm2/s [SD 0.024 cm2/s]; not significant). The time trends for FEV1, DL,CO, CT-PD15, and CT-RA-910 were all statistically significant. We found a high correlation between ADC and DL,CO ( P<0.001). Conclusion: This pilot study indicates the possible use of nonionizing HP 3He MRI for monitoring the progression of emphysema. However, in the future, larger studies are needed to confirm these preliminary results.

https://doi.org/10.3109/02841850903213822