Search results for " implantation."

showing 10 items of 677 documents

Ion irradiation of AZO thin films for flexible electronics

2017

Aluminum doped Zinc oxide (AZO) is a promising transparent conductor for solar cells, displays and touch-screen technologies. The resistivity of AZO is typically improved by thermal annealing at temperatures not suitable for plastic substrates. Here we present a non-thermal route to improve the electrical and structural properties of AZO by irradiating the TCO films with O+ or Ar+ ion beams (30–350 keV, 3 × 1015–3 × 1016 ions/cm2) after the deposition on glass and flexible polyethylene naphthalate (PEN). X-ray diffraction, optical absorption, electrical measurements, Rutherford Backscattering Spectrometry and Atomic Force Microscopy evidenced an increase of the crystalline grain size and a …

Nuclear and High Energy PhysicsMaterials science02 engineering and technology01 natural sciencesSettore ING-INF/01 - ElettronicaSettore FIS/03 - Fisica Della MateriaOpticsTransparent conductive oxideElectrical resistivity and conductivity0103 physical sciencesAZO ; Transparent conductive oxide ; Ion implantationElectrical measurementsThin filmPolyethylene naphthalateFlexible and transparent electronicInstrumentationTransparent conducting filmNuclear and High Energy Physic010302 applied physicsbusiness.industryAZO021001 nanoscience & nanotechnologyRutherford backscattering spectrometryIon implantationIon implantationOptoelectronicsCrystallite0210 nano-technologybusinessPhotovoltaic
researchProduct

Annealing reactions in lead implanted copper

2002

Abstract The terminal solubility of Pb in Cu is extremely low and does not exceed 0.09 at.% at 875 K. Ion implantation of lead ions at 100 keV into Cu single crystals produces metastable solutions. Annealing of the samples causes redistribution of the implanted atoms to equilibrium or near-equilibrium aggregate states which may be reflected in a change in the type of impurity lattice location in the host matrix. We have studied the effect of annealing on single crystalline Cu implanted at temperatures around 375 K with Pb to a concentration of a 1–2 at.%. Rutherford backscattering/channeling analysis and transmission electron microscopy of the as-implanted samples have shown that the implan…

Nuclear and High Energy PhysicsMaterials scienceAnnealing (metallurgy)Analytical chemistrychemistry.chemical_elementCopperIonCrystallographyIon implantationchemistryTransmission electron microscopyImpurityRedistribution (chemistry)SolubilityInstrumentationNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Ion implantation effects in BaTiO3 single crystals

1991

Abstract Thermally controlled helium implantation has been used to produce planar waveguides in BaTiO3 without noticeable depoling effects in the samples. Profiles for the ordinary and extraordinary refractive index are deduced from optical mode measurements. No annealing procedure is required. We report the effects of different ion fluences and energies in the MeV range on the waveguide properties.

Nuclear and High Energy PhysicsMaterials sciencebusiness.industryAnnealing (metallurgy)Physics::Opticschemistry.chemical_elementMolecular physicslaw.inventionIonOpticsIon implantationPlanarchemistrylawbusinessInstrumentationWaveguideRefractive indexHeliumNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

On the use of grazing-incidence small-angle X-ray scattering (GISAXS) in the morphological study of ion-implanted materials.

2004

Grazing-incidence small-angle X-ray scattering has become a widely used technique for the morphological analysis of surface systems. Here it is show how this technique can be applied to a buried system, like metallic clusters in glass obtained by ion implantation. The optimization of the data-collection geometry is described as well as the details of the quantitative data analysis. An experimental example on Cu + Au-implanted glasses shows the potentiality of the technique.

Nuclear and High Energy PhysicsRadiationAmorphous metalMaterials sciencebusiness.industryScatteringSmall-angle X-ray scatteringSynchrotron radiationSmall-angle neutron scatteringIonOpticsIon implantationGrazing-incidence small-angle scatteringIon implantation Surface plasmon resonance third-order opticalbusinessInstrumentationJournal of synchrotron radiation
researchProduct

Radiation induced defects in SiO 2

2002

The main luminescent centers in SiO 2 films are the red luminescence R (650 v nm; 1.85 v eV) of the non-bridging oxygen hole center (NBOHC) and the twofold-coordinated (divalent) silicon with a blue B (460 v nm; 2.7 v eV) and a UV band (285 v nm; 4.4 v eV). Especially the latter ones are produced under irradiation, but from existing precursors assumed as silicon related oxygen deficient centers (SiODC). Therefore, in order to prove these models we compare a direct oxygen implantation with a direct silicon implantation into SiO 2 layers. The main result is: implanting oxygen increases the red band R but does not affect the blue band B. Silicon surplus increases the amplitude of the blue (B) …

Nuclear and High Energy PhysicsRadiationMaterials scienceSiliconSilicon dioxideAnalytical chemistrychemistry.chemical_elementMineralogyCathodoluminescenceCondensed Matter PhysicsOxygenCrystallographic defectchemistry.chemical_compoundIon implantationchemistryGeneral Materials ScienceIrradiationLuminescenceRadiation Effects and Defects in Solids
researchProduct

Aesthetic perception of single implants placed in the anterior zone. A cross-sectional study

2016

Background: Several aesthetic indexes have been described to assess implant aesthetics. The aim of this study was to compare the aesthetic assessment made by dental professionals and students of single-tooth implants placed in the upper incisors. Material and Methods: A cross-sectional survey study using a subjective questionnaire to assess the aesthetics in 3 implant supported single-tooth cases in the anterior maxilla was performed. The interviewed subjects were divided into 4 groups: dentists with experience in implant treatment, dentists without experience in implants and 3rd and 5th year dental students. The questionnaire consisted of 2 visual analogue scales (VAS) to evaluate aestheti…

Odontologia estèticaCross-sectional studymedicine.medical_treatmentDentistryOdontologíaEsthetics DentalMedical care evaluation050105 experimental psychologyCrown (dentistry)Dental aesthetic03 medical and health sciences0302 clinical medicinePatient satisfactionstomatognathic systemCronbach's alphaMaxillaHumansMedicine0501 psychology and cognitive sciencesGeneral DentistryCrownsImplants dentalsbusiness.industryResearchDental Implantation Endosseous05 social sciencesDental prosthesisDental implantsReproducibility of Results030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludstomatognathic diseasesCross-Sectional StudiesTreatment OutcomeOtorhinolaryngologyPatient SatisfactionMaxillaUNESCO::CIENCIAS MÉDICASSurgeryDental Prosthesis Implant-SupportedImplantOral SurgerybusinessImplant supportedAvaluació de l'assistència mèdica
researchProduct

In vitro optical quality comparison of 2 trifocal intraocular lenses and 1 progressive multifocal intraocular lens.

2015

Purpose To evaluate the optical quality of 3 multifocal intraocular lenses (IOLs): the Mini Well Ready progressive multifocal aspheric IOL, the AT LISA trifocal diffractive IOL, and the Finevision full diffractive trifocal IOL. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods An instrument designed for measuring real-time modulation transfer function (MTF) and IOL power was used to measure the optical quality of each IOL for 3.0 mm and 4.5 mm apertures. This instrument measures both sagittal and tangential MTFs. The optical quality of each IOL was evaluated with the MTF, through-focus MTF, defocus tolerance, Strehl ratio MTF, and relative percentage of lig…

Optics and PhotonicsOptical PhenomenaComputer sciencemedicine.medical_treatmentCataract ExtractionProsthesis DesignRefraction Ocular03 medical and health sciencesNear vision0302 clinical medicineLens Implantation IntraocularOptical transfer functionmedicineProsthesis designHumansLenses IntraocularStrehl ratioCataract surgeryMultifocal intraocular lensModels TheoreticalSensory SystemsOptical qualityOphthalmologyIntraocular lenses030221 ophthalmology & optometryOptometrySurgery030217 neurology & neurosurgeryJournal of cataract and refractive surgery
researchProduct

Optical Quality Comparison of Conventional and Hole-Visian Implantable Collamer Lens at Different Degrees of Decentering

2012

To compare the optical quality of implantable Collamer lens (ICL) with and without central hole (Hole ICL and conventional ICL) at different degrees of decentering.Experimental laboratory investigation.Wavefront aberrations of the -3, -6, and -12 diopter (D) V4b and -3, -6, and -12 D V4c ICLs were measured in 3 conditions-centered and decentered 0.3 and 0.6 mm-at 3-mm and 4.5-mm pupils. The root mean square of total higher order aberrations, trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration were evaluated. In addition, point spread function and simulated retinal images of ICLs were calculated from the wavefront aberrations for each ICL and all conditions of decenteri…

Optics and PhotonicsPhakic Intraocular LensesCorneal Wavefront Aberrationgenetic structuresZernike polynomialsComa (optics)In Vitro TechniquesAstigmatismArtificial Lens Implant MigrationProsthesis DesignPhakic intraocular lensRetinasymbols.namesakeOpticsLens Implantation IntraocularmedicineHumansDioptreWavefrontPhysicsbusiness.industryAstigmatismModels Theoreticalmedicine.diseaseeye diseasesRefractive Surgical ProceduresOphthalmologySpherical aberrationAberrations of the eyesymbolsbusinessAmerican Journal of Ophthalmology
researchProduct

Assessing the in vitro optical quality of presbyopic solutions based on the axial modulation transfer function.

2016

Purpose To present a metric for assessing the in vitro optical quality of rotationally symmetrical optical elements based on volume calculation under the surface defined by the axial modulation transfer function (MTF). Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The metric volume under the axial MTF was used to assess the optical quality of 2 rotationally symmetrical multifocal intraocular lenses (IOLs) within various defocus intervals (0.50 diopter [D], 0.75 D, and 1.00 D) and at various spatial frequency intervals (7.5 cycles per degree [cpd], 15.0 cpd, and 30.0 cpd). Results The far focus of the bifocal IOL yielded higher volume values at all spati…

Optics and PhotonicsProsthesis Design01 natural sciences010309 optics03 medical and health sciences0302 clinical medicineOpticsLens Implantation IntraocularOptical transfer function0103 physical sciencesDioptreVision OcularMathematicsLenses Intraocularbusiness.industryMultifocal intraocular lensSensory SystemsOptical qualityOphthalmologySpainMetric (mathematics)030221 ophthalmology & optometrySurgeryObjective evaluationSpatial frequencybusinessFocus (optics)Journal of cataract and refractive surgery
researchProduct

Predictability of intraocular lens power calculation after small-incision lenticule extraction for myopia

2019

PURPOSE To evaluate and compare the predictability of intraocular lens (IOL) power calculation after small-incision lenticule extraction (SMILE) for myopia and myopic astigmatism. SETTING Department of Ophthalmology, Philipps University of Marburg, Marburg, Germany. DESIGN Retrospective comparative case series. METHODS Preoperative evaluation included optical biometry using IOLMaster 500 and corneal tomography using Pentacam HR. The corneal tomography measurements were repeated at 3 months postoperatively. The change of spherical equivalent due to SMILE was calculated by the manifest refraction at corneal plane (SMILE-Dif). A theoretical model, involving the virtual implantation of the same…

Optics and PhotonicsRefractive errormedicine.medical_specialtyBiometrymedicine.medical_treatmentIntraocular lensRefraction OcularMyopic astigmatism03 medical and health sciences0302 clinical medicineOptical biometryLens Implantation IntraocularGermanyOphthalmologyMyopiamedicineHumansSmall incision lenticule extractionDioptreRetrospective StudiesMathematicsLenses IntraocularPhacoemulsificationmedicine.diseaseSensory SystemsOphthalmology030221 ophthalmology & optometrySurgeryIntraocular lens power calculationRay tracing (graphics)030217 neurology & neurosurgeryJournal of Cataract and Refractive Surgery
researchProduct