Search results for " radiography"

showing 10 items of 70 documents

Characterization of clamp-on current transformers under nonsinusoidal conditions

2009

This paper reports the performance of clamp-on current transformers under nonsinusoidal conditions. A set of experimental measurements helped to determine the ratio and the phase errors under two conditions: 1) sinusoidal excitation with frequencies from 45 to 1000 Hz and 2) nonsinusoidal excitation using the fundamental frequency and one harmonic, with adjusted phase shift. It was found that ratio and phase errors are affected by the phase angle between the harmonic and the fundamental and the harmonic amplitude. The effects of conductor location in the current transformer's window and of the air-gap width were also investigated. It was concluded that harmonic phase and ratio errors measur…

Frequency responseMaterials scienceElectric current measurementTransductorAcousticsErrorsTransducersPhase (waves)Energy Engineering and Power TechnologyClamp-on current transformers current transformers (CTs) frequency response power system harmonics transducers.Power transformersDistributed power generationElectric power systemsHarmonic analysisElectric power transmission networksClamp-on current transformersCurrent transformersFrequency responsePower electronicsFrequency measurementElectronic engineeringElectrical and Electronic EngineeringElectrical conductorTomographyComputed tomographyElectric power distributionElectric transformersCircuit faultsFault currentsFundamental frequencyComputerized tomographyFourier seriesCurrent measurementCurrent transformerDiagnostic radiographyElectric instrument transformersElectric frequency measurementPower system harmonicsMedical imagingCurrent transformers (CTs)Air gap (plumbing)Power transmissionElectric network analysisExcitation
researchProduct

Numerical and experimental study of liquid metal stirring by rotating permanent magnets

2018

In this work, we study liquid gallium stirring by rotating permanent magnets. We demonstrate possibility of easily creating different flow patterns by rotating permanent magnets, which can be industrially important for controlling heat and mass transfer processes in the system. Unlike the typical approach of simulating magnet rotation as a transient problem and time-averaging the Lorentz forces, we solve the magnet rotation as a harmonic (frequency domain) problem, which leads to forces equal to time-averaged ones and decreases the simulation time considerably. Numerical results are validated using qualitative flow structure results from the neutron radiography visualization of tracer parti…

Liquid metalMaterials sciencePermanent magnetsNumerical modelsUltrasonic Doppler velocimeters02 engineering and technologyQuantitative dataRotationHeat and mass transfer process020501 mining & metallurgyPhysics::Fluid DynamicsMagnetohydrodynamicssymbols.namesakeFrequency domainsneutron radiographyLiquid metal stirringTransient problemsFrequency domain analysisddc:530Mass transferUDVMagnetic materialsMetal meltingNumerical and experimental studyData visualizationnumerical modellingMechanicsVelocimetry0205 materials engineeringFrequency domainMagnetNumerical resultsHarmonicsymbolsUltrasound Doppler velocimetryDewey Decimal Classification::500 | Naturwissenschaften::530 | PhysikTransient (oscillation)Lorentz forceLiquid metalsIOP Conference Series: Materials Science and Engineering
researchProduct

MULTI-SCALE ANALYSIS OF LUNG COMPUTED TOMOGRAPHY IMAGES

2007

A computer-aided detection (CAD) system for the identification of lung internal nodules in low-dose multi-detector helical Computed Tomography (CT) images was developed in the framework of the MAGIC-5 project. The three modules of our lung CAD system, a segmentation algorithm for lung internal region identification, a multi-scale dot-enhancement filter for nodule candidate selection and a multi-scale neural technique for false positive finding reduction, are described. The results obtained on a dataset of low-dose and thin-slice CT scans are shown in terms of free response receiver operating characteristic (FROC) curves and discussed.

LungReceiver operating characteristicmedicine.diagnostic_testComputer sciencebusiness.industryFOS: Physical sciencesPattern recognitionComputed tomographyCADFilter (signal processing)Physics - Medical PhysicsScale analysis (statistics)Reduction (complexity)Computerized Tomography (CT) and Computed Radiography (CR ).medicine.anatomical_structuremedicineSegmentationMedical Physics (physics.med-ph)Artificial intelligencebusinessInstrumentationMedical-image reconstruction methods and algorithms computer-aided soMathematical Physics
researchProduct

Impacted maxillary canines and root resorption of adjacent teeth: a retrospective observational study

2016

Background The prevalence of impacted maxillary canine is reported to be between 1% and 3%. The lack of monitoring and the delay in the treatment of the impacted canine can cause different complications such as: displacement of adjacent teeth, loss of vitality of neighbouring teeth, shortening of the dental arch, follicular cysts, canine ankylosis, recurrent infections, recurrent pain, internal resorption of the canine and the adjacent teeth, external resorption of the canine and the adjacent teeth, combination of these factors. An appropriate diagnosis, accurate predictive analysis and early intervention are likely to prevent such undesirable effects. The objective is to evaluate, by means…

MaleCuspidRadiographyDentistryRoot resorptionangulationsurgery03 medical and health sciences0302 clinical medicineMaxillaAnkylosismedicineHumans030212 general & internal medicineChildGeneral DentistryRetrospective Studiesotorhinolaryngology2734 pathology and forensic medicinedentistry (all)business.industryResearchTooth ImpactedMaxillary canineRetrospective cohort study030206 dentistrypredictionangulation; impacted canine; panoramic radiography; prediction; root resorption; surgery; otorhinolaryngology2734 pathology and forensic medicine; dentistry (all):CIENCIAS MÉDICAS [UNESCO]medicine.diseaseimpacted canineResorptionDental archmedicine.anatomical_structureOtorhinolaryngologyMaxillaUNESCO::CIENCIAS MÉDICASpanoramic radiographyFemaleOral Surgeryroot resorptionbusiness
researchProduct

Factors Associated With Severe Gastrointestinal Diagnoses in Children With SARS-CoV-2 Infection or Multisystem Inflammatory Syndrome

2021

Key Points Question Is COVID-19 associated with severe gastrointestinal manifestations in children? Findings In this multicenter cohort study of 685 Italian children with COVID-19, 10% showed severe gastrointestinal involvement characterized by diffuse adeno-mesenteritis, appendicitis, abdominal fluid collection, ileal intussusception, or pancreatitis. Children older than 5 years and those presenting with abdominal pain, leukopenia, or receiving a diagnosis of multisystem inflammatory syndrome were more likely to have severe gastrointestinal manifestations. Meaning Severe gastrointestinal involvement is not uncommon in children with COVID-19, and awareness about its frequency and presentati…

MaleGastrointestinalPrognosiGastrointestinal DiseasesGastrointestinal DiseaseMultisystem Inflammatory SyndromeCOVID-19; Child; Child Preschool; Female; Gastrointestinal Diseases; Humans; Male; Prognosis; Radiography; Retrospective Studies; SARS-CoV-2; Systemic Inflammatory Response Syndromemacromolecular substancesSarsCoV2PediatricsRetrospective StudieHumansChildPreschoolChildrenOriginal InvestigationRetrospective StudiesSARS-CoV-2ResearchGastrointestinal Children SARS-CoV-2 Multisystem Inflammatory SyndromeCOVID-19General MedicinePrognosisSettore MED/38gastrointestinalSystemic Inflammatory Response SyndromeRadiographyOnline OnlyChild PreschoolFemaleSarsCoV2; COVID-19; gastrointestinalHuman
researchProduct

Correction: Association of ionizing radiation dose from common medical diagnostic procedures and lymphoma risk in the Epilymph case-control study

2020

International audience; Medical diagnostic X-rays are an important source of ionizing radiation (IR) exposure in the general population; however, it is unclear if the resulting low patient doses increase lymphoma risk. We examined the association between lifetime medical diagnostic X-ray dose and lymphoma risk, taking into account potential confounding factors, including medical history. The international Epilymph study (conducted in the Czech-Republic, France, Germany, Ireland, Italy, and Spain) collected self-reported information on common diagnostic X-ray procedures from 2,362 lymphoma cases and 2,465 frequency-matched (age, sex, country) controls. Individual lifetime cumulative bone mar…

MaleLimfomesLymphoma[SDV.IB.IMA]Life Sciences [q-bio]/Bioengineering/ImagingPhysiologyLogistic regressionPediatrics030218 nuclear medicine & medical imagingDiagnostic RadiologyHematologic Cancers and Related Disorders0302 clinical medicineRisk FactorsBone MarrowRadiation IonizingImmune PhysiologyOdds RatioMedicine and Health SciencesMedicineFamily historyCàncerCancerCancer risk factorseducation.field_of_studyMultidisciplinaryFactors de risc en les malaltiesRadiology and ImagingQConfoundingRHematologyMiddle AgedRadiation ExposureBone Imaging3. Good healthOncology030220 oncology & carcinogenesisMedicineFemaleLymphomasResearch ArticleAdultmedicine.medical_specialtyRisk factors in diseasesImaging TechniquesSciencePopulationImmunology[SDV.CAN]Life Sciences [q-bio]/CancerRadiation DosageResearch and Analysis Methods03 medical and health sciences[SDV.CAN] Life Sciences [q-bio]/CancerRheumatologyDiagnostic MedicineInternal medicineOsteoarthritisCancer Detection and DiagnosisHumansMedical historyeducationAgedbusiness.industryArthritisCase-control studyCorrectionCancers and NeoplasmsBiology and Life SciencesOdds ratiomedicine.diseaseLymphomaX-Ray RadiographyMedical risk factorsLogistic Models[SDV.IB.IMA] Life Sciences [q-bio]/Bioengineering/Imaging[SDV.SPEE] Life Sciences [q-bio]/Santé publique et épidémiologieCase-Control StudiesImmune System[SDV.SPEE]Life Sciences [q-bio]/Santé publique et épidémiologiebusinessPLoS ONE
researchProduct

Comparative Analysis of Peri-Implant Bone Loss in Extra-Short, Short, and Conventional Implants. A 3-Year Retrospective Study

2020

Objective: To evaluate the influence of implant length on marginal bone loss, comparing implants of 4 mm, 6 mm, and &gt

MaleMolarmarginal bone lossPeri-implantitisHealth Toxicology and MutagenesisRadiographyAlveolar Bone LossDentistrylcsh:MedicinePeri implant boneArticleMandibular second molar03 medical and health sciences0302 clinical medicineimplant-supported prosthesesshort dental implantsHumansMedicineDental Restoration FailureRetrospective StudiesDental Implantstissue-levelCrownsbusiness.industryPeriapical radiographylcsh:RPublic Health Environmental and Occupational HealthRetrospective cohort study030206 dentistryMolarTreatment Outcome030220 oncology & carcinogenesisFemaleImplantbusinessFollow-Up Studiesperi-implantitisInternational Journal of Environmental Research and Public Health
researchProduct

Improving pediatric radiation dose management using Agfa digital radiography DICOM header information

2007

Dose reduction in pediatric explorations is especially important because of children radiation sensitivity. According to this, with the aim of saving radiation exposure in future clinical practice, we have developed a technique to control delivered dose in pediatric radiographic exams. To that, a computer science program has been developed to calculate entrance skin dose (ESD) provided by AGFA radiology digital system, using the "lgM" parameter exported from Dicom files. ESD values are compared with dose limits established in regulations to detect if children are being exposed to excessive amounts of radiation during their explorations.

Malemedicine.medical_specialtybusiness.industryRadiographyRadiation DosageRadiographic Image EnhancementRadiation exposureDICOMEntrance skin doseChild PreschoolHeaderHumansMedicineDosimetryFemaleDose reductionMedical physicsChildbusinessNuclear medicineSoftwareDigital radiography2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
researchProduct

Diagnostic accuracy of computed tomographic colonography for the detection of advanced neoplasia in individuals at increased risk of colorectal cance…

2009

CONTEXT: Computed tomographic (CT) colonography has been recognized as an alternative for colorectal cancer (CRC) screening in average-risk individuals, but less information is available on its performance in individuals at increased risk of CRC. OBJECTIVE: To assess the accuracy of CT colonography in detecting advanced colorectal neoplasia in asymptomatic individuals at increased risk of CRC using unblinded colonoscopy as the reference standard. DESIGN, SETTING, AND PARTICIPANTS: This was a multicenter, cross-sectional study. Individuals at increased risk of CRC due to either family history of advanced neoplasia in first-degree relatives, personal history of colorectal adenomas, or positiv…

Maleoccult blood testColorectal cancerColonoscopycancer riskprediction and forecastingGastroenterologyRisk Factorscancer diagnosisPositive predicative valueadvanced cancerMedicineFamily historycomparative studycolorectal adenomafamily historyeducation.field_of_studymedicine.diagnostic_testarticleclinical trialGeneral MedicineColonoscopyMiddle Agedpriority journalrisk factorPredictive value of testsdiagnostic accuracyFemalediagnostic valueColorectal NeoplasmsColonography Computed TomographicradiographyComputed TomographicAdultmedicine.medical_specialtySettore MED/12 - GASTROENTEROLOGIAPopulationcolorectal cancerSensitivity and SpecificityPredictive Value of TestsInternal medicineadult; advanced cancer; aged; article; cancer classification; cancer diagnosis; cancer risk; clinical trial; colonoscopy; colorectal adenoma; colorectal cancer; computed tomographic colonography; controlled clinical trial; controlled study; cross-sectional study; diagnostic accuracy; diagnostic value; family history; female; human; major clinical study; male; multicenter study; occult blood test; predictive validity; priority journal; colorectal tumor; comparative study; middle aged; prediction and forecasting; radiography; risk factor; sensitivity and specificity; Adult; Aged; Colonography Computed Tomographic; Colonoscopy; Colorectal Neoplasms; Cross-Sectional Studies; Female; Humans; Male; Middle Aged; Predictive Value of Tests; Risk Factors; Sensitivity and Specificitycross-sectional studyHumanscontrolled studyhumaneducationAgedcontrolled clinical trialbusiness.industryFecal occult bloodSigmoidoscopyColonographymedicine.diseasecancer classificationcomputed tomographic colonographymajor clinical studypredictive validitymulticenter studyCross-Sectional StudiesCT colonography colorectal cancer screeningSettore MED/36 - Diagnostica Per Immagini E Radioterapiabusinesscolorectal tumorJAMA
researchProduct

Diagnostic Performance and Radiation Dose of the EOS System to Image Enchondromatosis: A Phantom Study

2020

Background: Radiation doses and capability of EOS, conventional radiography (CR), and computed tomography (CT) to detect and measure enchondromas in a dedicated five-year-old anthropomorphic phantom were compared. Methods: To simulate enchondromas, minced pieces of chicken bone and cartilage were packed in conventional kitchen plastic foil to create ovoidal/rounded masses and randomly hung on the phantom. The phantom was imaged five times with CR, CT, and EOS, each time changing the number and position of inserts. All images were reviewed by a senior radiologist and a radiology resident. Results: EOS and CR detected all inserts in 4/5 cases (80%), while in one case 1/17 inserts was not seen…

Materials scienceComputed tomographylcsh:TechnologyImaging phantom030218 nuclear medicine & medical imagingenchondromalcsh:Chemistry03 medical and health sciences0302 clinical medicineEnchondromatosismedicineGeneral Materials Sciencelcsh:QH301-705.5InstrumentationFluid Flow and Transfer ProcessesReproducibilitymedicine.diagnostic_testlcsh:Tbusiness.industryEOSProcess Chemistry and TechnologyRadiation doseGeneral Engineeringcomputed tomographyRepeatabilityphantommedicine.diseaseconventional radiographylcsh:QC1-999Computer Science ApplicationsConventional radiographylcsh:Biology (General)lcsh:QD1-999lcsh:TA1-2040Anthropomorphic phantomlcsh:Engineering (General). Civil engineering (General)Nuclear medicinebusinessradiation doselcsh:Physics030217 neurology & neurosurgeryApplied Sciences
researchProduct