Search results for " standard deviation"
showing 10 items of 79 documents
Selective determination of clenbuterol residues in urine by molecular imprinted polymer—Ion mobility spectrometry
2017
Abstract Clenbuterol is banned for sports use and strictly regulated in livestock industry. In this study, a procedure for the determination of clenbuterol residues in water and urine has been developed using selective supports combined with ion mobility spectrometry (IMS) determination. A molecular imprinted polymer (MIP) was used for efficient clean-up and preconcentration of clenbuterol followed to a dispersive liquid-liquid microextraction (DLLME) in order to improve selectivity and sensitivity of IMS determinations. Quantitative recoveries from 81 to 99% were obtained for water and spiked urine samples using MIP-DLLME-IMS method. A precision of 4.5%, established as the relative standar…
Die direkte quantitative auswertung von dünnschichtchromatogrammen durch remissions- und fluoreszenzmessungen
1971
Abstract Direct quantitative evaluation of thin-layer chromatograms by remission- and fluorescence measurements. Part 6. Determination of adrenaline, noradrenaline and dopamine from urine Adrenaline, noradrenalineand dopamine were separated from urine on aluminium oxide columns; after elution they were converted into ther O 3 ,O 4 ,N-triacetyl derivatives and separated using thin-layer chromatography. The triacetyl derivatives were in situ converted to fluorescing compounds using ethylene diamine and quantitatively estimated using the Chromatogram-Spectrophotometer (Carl Zeiss, Oberkochen). The advantage of this method over the conventional fluorometric determination of catecholamines in so…
Fast extraction methodologies for the determination of toxic arsenic in meat
2017
Summary A nonchromatographic analytical procedure has been developed for the determination of arsenic in meat samples including the major toxic arsenic species arsenite, arsenate, monomethylarsonic acid (MMA) and dimetylarsinic acid (DMA). The method is based on the extraction of arsenic species in mild conditions, selective trivalent hydride formation and final determination by hydride generation atomic fluorescence spectroscopy (HG-AFS). Different extractant agents and two different procedures, microwave-assisted extraction (MAE) and ultrasound assisted extraction at room temperature, were evaluated for As species extraction. The method provided a limit of detection of 0.013 ng mL−1 and a…
Uptake and translocation monitoring of imidacloprid to chili and tomato plants by molecularly imprinting extraction - ion mobility spectrometry
2019
Abstract The degradation of imidacloprid in soil and its uptake and translocation to chili and tomato plants was evaluated, as a proof of concept, of the possibilities of the combination of molecularly imprinted polymers (MIPs) and ion mobility spectrometry (IMS) for a fast and sensitive bioprocesses monitoring tool. To do it, a method based on the selective extraction of imidacloprid from soil and plant materials was developed. In the selected conditions, the MIP-IMS procedure provided a recovery of imidacloprid in soil and plant samples from 102 to 114%, for spiked concentration levels from 0.2 to 2.0 μg g−1. Precision of the methodology, expressed as the relative standard deviation (RSD)…
Solid glucose biosensor integrated in a multi-well microplate coupled to a camera-based detector: Application to the multiple analysis of human serum…
2018
Abstract In the present work, a biosensor adapted in a 96-well microplate has been coupled with a smartphone-based photometer in order to develop a low-cost colorimetric multi-sample dispositive. The strength of this biosensing system is based on the integration of the biosensor into the 96-well microplate and the use of a smartphone and free image analysis software as a microplate reader. The performance of the proposed biosensor has been demonstrated to determine glucose in several human serum samples. This method is simple, cost-effective, sensitive and selective for the determination of glucose in serum, with detection limits of 1.8 mg/dL and a good linearity over the range 6–88 mg/dL. …
Flow analysis-spectrophotometric determination of ?-dopa in pharmaceutical formulations by reaction with p-Aminophenol
1994
Abstract A new method has been developed for the spectrophotometric determination of l -dopa in pharmaceutical formulations. The method is based on the reaction between the open-chain quinone of l -dopa, obtained in NaOH, and the benzoqinoneimine form of p-aminophenol, in the presence of KIO4. The reaction product is determined at 574 nm by using both alternately procedures, one based on the stopped-flow and another on a flow injection approach. Under the best experimental conditions L-dopa can be determined with a limit of detection of 52 ng/ml and a relative standard deviation of 0.2% for three replicate measurements of a solution containing 4 μg/ml.
Rapid microwave assisted hydrolysis of formetanate
1993
Abstract A fast microwave-assisted hydrolysis procedure has been developed for the derivatization of formetanate previously to the flow-injection spectrophotometric determination of m -aminophenol by reaction with p -aminophenol. Formetanate is quantitatively hydrolyzed with 0.1 M NaOH in 150 s using a closed polyetrafluoroethylene reactor with 115 ml internal volume and a radiation power of 390 W. The above procedure has been applied, as a previous step, for the flow-injection spectrophotometric determination of formetanate in spiked water samples and accurate and precise results have been found. The method permits to obtain a limit of detection of 0.025 mg 1 −1 of formetanate. The relativ…
HPLC determination of oxadiazon in commercial pesticide formulations
2008
A simple, fast and precise high performance liquid chromatographic (HPLC) procedure has been developed for the determination of oxadiazon in emulsifiable concentrated pesticide formulations. 20 µL of diluted sample in acetonitrile were injected in a Kromasil C18 (250 ×am injetados em uma coluna Kromasil C18 4.6 mm, 5 µm) column, using acetonitrile:water (80:20) as mobile phase at 1 mL min-1 flow rate and oxadiazon determined by absorbance measurement at 292 nm. A theoretical limit of detection of 0.02 µg mL-1, a limit of quantification of 0.047 µg mL-1, corresponding to a 0.02 and 0.07% m/v in the original sample, and a relative standard deviation of 0.08% for three replicate analysis of sa…
Simultaneous determination of hydride and non-hydride forming elements by inductively coupled plasma optical emission spectrometry
2011
e percentagens de recuperacao entre 97 e 103%. A aplicabilidade do sistema foi demonstrada na determinacao simultânea de Ca, Cd, Co, Cr, Cu, Fe, Mg, Mn, Mo, Ni, Zn, As, Bi, Sb, Se e Te em amostras certificadas para elementos tracos, NIST 1549 (leite em po desnatado), NIST 1570a (folhas de espinafre), DORM-2 (musculo de cacao) e TORT-2 (hepatopâncreas de lagosta). Os resultados obtidos foram concordantes com os teores certificados. The operating characteristics of a dual nebulization system were studied including instrumental and chemical conditions for the hydride generation and analytical figures of merit for both, hydride and non hydride forming elements. Analytical performance of the neb…
Non-chromatographic speciation of mercury in mushrooms
2016
A fast, sensitive and cheap procedure has been developed for the determination of inorganic mercury (i-Hg) and organic mercury (o-Hg) in mushroom samples. The procedure is based on the use of cold vapour atomic fluorescence spectrometry (CV-AFS). The method involves the extraction of total mercury (t-Hg) with diluted HCl, followed by measurements of the corresponding Hg vapour under two different conditions: (i) directly to determine i-Hg, and (ii) after oxidation with a mixture KBr/KBrO3 to determine t-Hg. o-Hg was estimated from the difference between t-Hg and i-Hg. Previous studies were focused on the assessment of different reagents for mercury extraction and breakdown of organomercury …