Search results for "Diode"
showing 10 items of 469 documents
Electrical Characterization of CdTe pixel detectors with Al Schottky anode
2014
Abstract Pixelated Schottky Al/p-CdTe/Pt detectors are very attractive devices for high-resolution X-ray spectroscopic imaging, even though they suffer from bias-induced time instability (polarization). In this work, we present the results of the electrical characterization of a (4×4) pixelated Schottky Al/p-CdTe/Pt detector. Current–voltage ( I–V ) characteristics and current transients were investigated at different temperatures. The results show deep levels that play a dominant role in the charge transport mechanism. The conduction mechanism is dominated by the space charge limited current (SCLC) both under forward bias and at high reverse bias. Schottky barrier height of the Al/CdTe con…
Extracting parameters from semi-log plots of polycrystalline silicon PV modules outdoor I–V data: Double-exponential model revisited
2010
This paper presents a method for extracting physically meaningful parameters from measured I–V curves of PV modules. The 7-parameter double-exponential model is applied in the modeling. The method is based on linear fitting of semi-logarithmic plots. The paper demonstrates a new technique to estimate the series resistance of a module with high accuracy from such plots. As a result, also the reverse saturation current and the quality factor of the diffusion diode can be determined. The method is applied to outdoor I–V data from a test station with three similar, but not identical, polycrystalline-Si modules. The values of the series resistances found with this method deviate somewhat from th…
Vibrational and rotational collisional relaxation in CO2–Ar and CO2–He mixtures studied by stimulated Raman-infrared double resonance
1999
0021-9606; The collisional relaxation among vibrational levels of the Fermi dyad of CO2 mixed with Ar and He (10% CO2, 90% rare gas) has been studied at room temperature with a double resonance experiment. Stimulated Raman effect from the ground state achieved the pumping process with a Nd:YAG laser and a pulse amplified dye laser. After pumping the v(1) or 2v(2)(Sigma(+)g) level, a cw CO2 laser was used to probe either the depopulation rates of the pumped levels (vibrationally or rotationally resolved) or the energy transfer rates to neighboring states. The vibrational energy relaxation has been studied from experimental depopulation of v(1) and population of 2v(2) levels through a five-le…
Are analysts doing method validation in liquid chromatography?
2014
International audience; Method validation is being applied in the reported analytical methods for decades. Even before this protocol was defined, authors already somehow validated their methods without full awareness. They wished to assure the quality of their work. Validation is an applied approach to verify that a method is suitable and rugged enough to function as a quality control tool in different locations and times. The performance parameters and statistical protocols followed throughout a validation study vary with the source of guidelines. Before single laboratory validation, an analytical method should be fully developed and optimized. The purpose of the validation is to confirm p…
Exciton quenching by diffusion of 2,3,5,6-tetrafluoro-7,7’,8,8’-tetra cyano quino dimethane and its consequences on joule heating and lifetime of org…
2013
In this Letter, the effect of F(4)-TCNQ insertion at the anode/hole transport layer (HTL) interface was studied on joule heating and the lifetime of organic light-emitting diodes (OLEDs). Joule heating was found to reduce significantly (pixel temperature decrease by about 10 K at a current density of 40 mA/cm(2)) by this insertion. However, the lifetime was found to reduce significantly with a 1 nm thick F(4)-TCNQ layer, and it improved by increasing the thickness of this layer. Thermal diffusion of F(4)-TCNQ into HTL leads to F(4)-TCNQ ionization by charge transfer, and drift of these molecules into the emissive layer caused faster degradation of the OLEDs. This drift was found to reduce w…
Modeling and Characterization of SiPM Parameters at Temperatures between 95 K and 300 K
2017
The modeling and characterization of silicon photomultipliers (SiPMs) in a wide temperature range from 95 K to 300 K is presented. The devices under study had the distinctive feature of forward-biased p-n junctions situated under each pixel as active quenching resistors making them particularly appropriate to be operated at cryogenic temperatures. The voltage drop across the diode in a forward direction was measured for a series of injected currents in this temperature range. It was observed that the characteristics of different SiPM types influence the temperature dependence of the reverse saturation current. The devices were further characterized by low-level light-pulse measurements. The…
Adaption of a PIN-diode detector as an online neutron monitor for the thermal column of the TRIGA research reactor.
2017
A BNCT online neutron monitoring system was tested in a TRIGA reactor, using a silicon PIN-diode with a conversion foil. The setup was tested with different reactor powers at the hot and cold ends of the irradiation channel, using activation foils to compare with measured fluxes. The results demonstrate good reproducibility and show a linear correlation between signal of the PIN-diode and neutron flux at all positions, demonstrating this approach to be suitable for online monitoring of the neutron flux.
Cytotoxicity, antibacterial and physicochemical properties of a new epoxy resin-based endodontic sealer containing calcium hydroxide
2019
Background This study evaluated the cytotoxicity, antibacterial and physicochemical properties of a new epoxy resin-based endodontic sealer containing calcium-hydroxide Sealer Plus. AH Plus was used as a reference for comparison. Material and Methods Cytotoxicity evaluation was performed according to ISO-10993-5 specifications using MTT assay to check the 3T3 cells viability at 1- to 4-week periods. Antibacterial activity was evaluated using a direct contact test against Enterococcus faecalis. Radiopacity, solubility and flow evaluations were performed according to ISO-6876/2012 specifications. Setting time was assessed following the ANSI/ADA-standard-n.57. The pH level was measured at 3,24…
Evaluation of diode laser application on chemical analysis and surface microhardness of white spots enamel lesions with two remineralizing agents
2020
Background To investigate the effect of diode laser application and two commercial remineralizing agents on the remineralization and surface microhardness of white spot enamel lesions. Material and methods Sixty specimens were prepared then equally divided into six groups (n=10/group), according to the diode laser and the two commercial remineralizing agents applied to demineralized enamel surfaces (APF gel and sodium fluoride NaF mousse) with or without diode Laser application as follows; Group A; control, Group B; diode Laser application, Group C; APF gel application, Group D; NaF mousse application, Group E; APF gel application + diode Laser, Group F; NaF mousse application+ diode Laser.…
Wireless photoplethysmography finger sensor probe
2010
A sensitive, digital, wireless sensor probe has been developed for photoplethysmography (PPG) measurements. It uses standard light emitting source and detector. The main advantage of this approach is to measure discharge time of the photodiode as amplitude of PPG signal. It reduces the cost, dimensions, power consumption and filtering of the device. First results of distant monitoring of heart rate using the newly developed sensor probe are presented.