Search results for "Equipment Design"
showing 10 items of 409 documents
Taking Advantage of Selective Change Driven Processing for 3D Scanning
2013
This article deals with the application of the principles of SCD (Selective Change Driven) vision to 3D laser scanning. Two experimental sets have been implemented: one with a classical CMOS (Complementary Metal-Oxide Semiconductor) sensor, and the other one with a recently developed CMOS SCD sensor for comparative purposes, both using the technique known as Active Triangulation. An SCD sensor only delivers the pixels that have changed most, ordered by the magnitude of their change since their last readout. The 3D scanning method is based on the systematic search through the entire image to detect pixels that exceed a certain threshold, showing the SCD approach to be ideal for this applicat…
Label swapper device for spectral amplitude coded optical packet networks monolithically integrated on InP
2011
In this paper the design, fabrication and experimental characterization of an spectral amplitude coded (SAC) optical label swapper monolithically integrated on Indium Phosphide (InP) is presented. The device has a footprint of 4.8x1.5 mm 2 and is able to perform label swapping operations required in SAC at a speed of 155 Mbps. The device was manufactured in InP using a multiple purpose generic integration scheme. Compared to previous SAC label swapper demonstrations, using discrete component assembly, this label swapper chip operates two order of magnitudes faster. © 2011 Optical Society of America.
Automatable sample fabrication process for pump-probe X-ray holographic imaging
2014
Soft X-ray holography is a recently developed imaging technique with sub-50 nm spatial resolution. Key advantages of this technique are magnetic and elemental sensitivity, compatibility with imaging at free electron laser facilities, and immunity to in-situ sample excitations and sample drift, which enables the reliable detection of relative changes between two images with a precision of a few nanometers. In X-ray holography, the main part of the experimental setup is integrated in the sample, which consequently requires a large number of fabrication steps. Here we present a generic design and an automatable fabrication process for samples suitable, and optimized for, efficient high resolut…
Diffractive optics for quasi-direct space-to-time pulse shaping.
2008
The strong chromatic behavior associated with a conventional diffractive lens is fully exploited to propose a novel optical device for pulse shaping in the femtosecond regime. This device consists of two optical elements: a spatially patterned circularly symmetric mask and a kinoform diffractive lens, which are facing each other. The system performs a mapping between the spatial position of the masking function expressed in the squared radial coordinate and the temporal position in the output waveform. This space-to-time conversion occurs at the chromatic focus of the diffractive lens, and makes it possible to tailor the output central wavelength along the axial location of the output point…
Fiber-based device for the detection of low-intensity fluctuations of ultrashort pulses
2012
International audience; We describe a fiber-based device that can significantly enhance the low intensity fluctuations of an ultrashort pulse train to detect them more easily than with usual direct detection systems. Taking advantage of the Raman intrapulse effect that progressively shifts the central frequency of a femtosecond pulse propagating in an anomalous dispersion fiber, a subsequent spectral filtering can efficiently increase the level of fluctuations by more than one order of magnitude. We show that attention has to be paid to maintain the shape of the statistical distribution unaffected by the nonlinear process.
Formation of ultrashort triangular pulses in optical fibers
2014
Specialty shape ultrashort optical pulses, and triangular pulses in particular, are of great interest in optical signal processing. Compact fiber-based techniques for producing the special pulse waveforms from Gaussian or secant pulses delivered by modern ultrafast lasers are in demand in telecommunications. Using the nonlinear Schr¨odinger equation in an extended form the transformation of ultrashort pulses in a fiber towards triangular shape is characterized by the misfit parameter under variety of incident pulse shapes, energies, and chirps. It is shown that short (1-2 m) conventional single mode fiber can be used for triangular pulse formation in the steady-state regime without any pre-…
Femtosecond parabolic pulse shaping in normally dispersive optical fibers
2013
Formation of parabolic pulses at femtosecond time scale by means of passive nonlinear reshaping in normally dispersive optical fibers is analyzed. Two approaches are examined and compared: the parabolic waveform formation in transient propagation regime and parabolic waveform formation in the steady-state propagation regime. It is found that both approaches could produce parabolic pulses as short as few hundred femtoseconds applying commercially available fibers, specially designed all-normal dispersion photonic crystal fiber and modern femtosecond lasers for pumping. The ranges of parameters providing parabolic pulse formation at the femtosecond time scale are found depending on the initia…
Pulse quality analysis on soliton pulse compression and soliton self-frequency shift in a hollow-core photonic bandgap fiber.
2013
A numerical investigation of low-order soliton evolution in a proposed seven-cell hollow-core photonic bandgap fiber is reported. In the numerical simulation, we analyze the pulse quality evolution in soliton pulse compression and soliton self-frequency shift in three fiber structures with different cross-section sizes. In the simulation, we consider unchirped soliton pulses (of 400 fs) at the wavelength of 1060 nm. Our numerical results show that the seven-cell hollow-core photonic crystal fiber, with a cross-section size reduction of 2%, promotes the pulse quality on the soliton pulse compression and soliton self-frequency shift. For an input soliton pulse of order 3 (which corresponds to…
Radiation leakage study for the Valencia applicators
2011
Abstract Introduction and purpose The Valencia applicators which are accessories of the microSelectron-HDR afterloader (Nucletron, Veenendaal, The Netherlands) are designed to treat skin lesions. These cup-shaped applicators are an alternative to superficial/orthovoltage x-ray treatment units. They limit the irradiation to the required area using tungsten-alloy shielding, and are equipped with a tungsten-alloy flattering filter allowing the treatment of skin tumors, the oral cavity, vaginal cuff, etc. The tungsten-alloy thickness to shield radiation is not the same in all parts of the applicators. This fact led us to question whether the leakage radiation differs depending on where it is me…
Material properties of various intraocular lenses in an experimental study.
2002
<i>Introduction:</i> With the recent introduction of small-incision cataract surgery, requirements for intraocular lens (IOL) flexibility, strength and hydrophilicity have rapidly evolved. The IOL surface, however, remains a critical factor influencing uveal biocompatibility. <i>Purpose:</i> To objectively quantify factors of material properties of various IOLs using contact angle measurements, differential scanning calorimetry, dynamic-mechanical measurements and scanning electron microscopy. <i>Material and Methods:</i> In our study, 17 currently available IOLs were investigated using contact angle measurements to assess hydrophilicity and biocompatibil…