Flow injection biamperometric determination of metronidazole with on-line photodegradation
1999
Abstract The determination of metronidazole is performed in a flow injection assembly, provided with a 40 W low pressure mercury lamp and a home-made biamperometric flow-cell furnished with two platinum electrodes polarized at 100 mV. The sample solution after being irradiated is inserted into a pure water stream. It then merges with an in situ mixed solution containing potassium iodide in sulphuric acid. The calibration graph was linear over the range 0.2–8.0 mg l −1 metronidazole; the 3 σ limit of detection was 0.008 mg l −1 ; the relative standard deviation was 0.6% (for 4 mg l −1 n = 13) and the sample throughput 50 h −1 . The influence of foreign compounds is slight and the method is …
Fourier transform infrared spectrometric strategies for the determination of Buprofezin in pesticide formulations
2002
Abstract Two different strategies for Buprofezin determination, an off-line extraction and stopped-flow determination and an automated procedure, based on the on-line extraction of Buprofezin samples with chloroform and flowing action analysis–fourier transform infrared (FIA–FT-IR) spectrometric measurement of the extracts, have been developed. For the treatment of the off-line extraction mode, data a three-factor partial least squares (PLSs) calibration was developed, using the region from 1465.7 to 1342.3 cm−1 with a single point baseline defined at 2051.9 cm−1 and based on the use of chloroform solutions of Buprofezin. The method provides a R.S.D. On the other hand, the recommended FIA m…
Direct flow injection chemiluminescence determination of salicylamide
1999
Abstract A new direct flow injection chemiluminescence method is proposed for the determination of salicylamide, based upon the oxidation of the drug by potassium permanganate in dilute sulphuric acid. The calibration graph is linear over the range 20 ng ml−1 (30 limit of detection)–8 μg ml−1 salicylamide, with a relative standard deviation (n=50, 0.5 μg ml−1) of 1.7%. The average sample insertion rate is 142 h−1. The influence of relevant foreign compounds is found to be relatively slight. The method is applied to the determination of salicylamide in a pharmaceutical formulation and human urine.
Fourier transform infrared spectrometric determination of Malathion in pesticide formulations
2004
Abstract An environmentally friendly methodology has been developed for quality control analysis of emulsifiable concentrate pesticide formulations containing Malathion as active ingredient, using flow injection analysis (FIA)–Fourier transform infrared (FTIR) spectrometry. Five microlitres samples were directly injected into a 3 ml closed FIA manifold, in which 2 ml of CHCl 3 was re-circulated at 1.96 ml min −1 . After homogenisation and sample measurement, 2 μl volumes of a Malathion standard were injected, taking absorbance measurements after each injection. Peak height of the chemigrams, established from peak area values between 1027 and 1017 cm −1 , corrected with a baseline fixed from…
Multipumping Nitrite Determination in Exhaled Breath Condensate
2006
Abstract A flow system based on multicommutation is proposed for the rapid, clean, and inexpensive determination of nitrites in small volumes of breath condensates. The procedure exploits the colorimetric detection of nitrite with the Griess reagent [0.03% naphthylethylene diamine dihydrochloride (NED), 0.5% sulpfhanilamide, and 3.0% phosphoric acid] in acidic medium at 540 nm correcting the variations of the baseline with measurements at 424 nm. The flow system was designed with a set of solenoid micropumps to minimize sample and reagent consumption and waste generation. The detection limit was estimated as 3.8 ng mL−1 (99.7% confidence level) with a linear response ranging up to 500 ng mL…
A multicommuted stop-flow system employing LEDs-based photometer for the sequential determination of anionic and cationic surfactants in water
2006
It has been developed an automatic stop-flow procedure for sequential photometric determination of anionic and cationic surfactants in a same sample of water. The flow system was based on multicommutation process that was designed employing two solenoid micro-pumps and six solenoid pinch valves, which under microcomputer control carry out fluid propelling and reagent solutions handling. A homemade photometer using a photodiode as detector and two light emitting diodes (LEDs) with emission at 470 nm (blue) and 650 nm (red) as radiation sources, which was tailored to allow the determination of anionic and cationic surfactants in waters. The procedure for anionic surfactant determination was b…
Determination of cyanide by a flow injection analysis-atomic absorption spectrometric method
1999
A new flow injection analysis (FIA) procedure is proposed for the indirect atomic absorption spectrometric determination of cyanide. The FIA manifold is based on the insertion of the sample into a distilled water carrier, then the sample flows through a solid-phase reactor filled with silver iodide entrapped in polymeric resin beads. The calibration graph is linear over the range 0.2-6.0 mg l-1 of cyanide (correlation coefficient 0.9974), the detection limit is 0.1 mg l-1, the sample throughput is 193 h-1 and the RSD is 0.8%. The method is simple, quick and more selective than other published FIA procedures. The reproducibility obtained by using different solid-phase reactors and solutions …
Flow injection spectrophotometric determination of lead using 1,5-diphenylthiocarbazone in aqueous micellar
2009
A simple flow injection colorimetric procedure for determining lead was established. It is based on the reaction of lead in sulfuric acid with 1,5-diphenylthiocarbazone and sodium dodecyl sulfate, resulting in an intense red-blue complex with a suitable absorption at 500 nm. A standard or sample solution was injected into the sulfuric acid stream (flow rate of 2.0 ml min(-1)), which was then merged with sodium dodecyl sulfate stream (flow rate of 2.0 ml min(-1)) and 1,5-diphenylthiocarbazone stream (flow rate of 1.5 ml min(-1)). Optimum conditions for determining lead were investigated by univariate method. Under the optimum conditions, a linear calibration graph was obtained over the range…
Flow injection-FTIR determination of dithiocarbamate pesticides
2000
A flow injection Fourier transform infrared spectrometric procedure has been developed for the determination the dithiocarbamate pesticides Ziram and Thiram in solid samples. All the operations involved, such as extraction, filtration and measurement, were integrated in the experimental set-up in order to avoid excessive manipulation of samples and standards. Ultrasonic assisted and mechanical extraction were evaluated for the solubilization of the analytes and, additionally, the effect of carrier flow rate, sample loop volume and the ratio between sample mass and volume of solvent employed were studied. Quantitative extractions with chloroform were obtained for both Ziram and Thiram, after…
Rapid on-line sample dissolution assisted by focused microwave radiation for silicate analysis employing flame atomic absorption spectrometry: iron d…
2004
An on-line automated flow injection system with microwave-assisted sample digestion was used to perform silicate rock dissolution in acid medium for iron determination. For this purpose, a continuous flow system was built up by using an automatic flow injection analysis (FIA) system coupled to a flame atomic absorption spectrometer (FAAS), including a focused microwave oven unit. Inside the microwave cavity was inserted a polytetrafluoroethylene (PTFE) reactor coil (300cm length and 0.8mm i.d.) where the dissolution takes place. Chemical and flow variables as well as iron determination parameters were studied. In the flow system, a slurry of the rock sample (50mg in 200ml of acid mixture HF…