Search results for "Reference"

showing 10 items of 2491 documents

Extraction of clenbuterol from calf urine using a molecularly imprinted polymer followed by quantitation by high-performance liquid chromatography wi…

2002

A method for the extraction of clenbuterol from calf urine samples using a molecularly imprinted polymer (MIP) has been developed. The aim was that the final extracts from the MIP should allow quantitation of clenbuterol down to 0.5 ng/mL urine using HPLC with UV detection. The MIP was produced using brombuterol as a template and the selectivity of the MIP, for clenbuterol, was tested against a non-imprinted polymer (produced without template) and was found to be high. After loading of 5 mL diluted centrifuged urine, selective binding was established in acetonitrile-acetic acid (98:2). For further elution of interferences, 0.5 M ammonium acetate buffer pH 5 and 70% acetonitrile in water was…

ChromatographyChemistryElutionOrganic ChemistryExtraction (chemistry)Molecularly imprinted polymerReproducibility of ResultsGeneral MedicineReversed-phase chromatographyReference StandardsSensitivity and SpecificityBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryClenbuterolmedicineAnimalsCattleClenbuterolSpectrophotometry UltravioletSample preparationSolid phase extractionAdrenergic alpha-AgonistsChromatography High Pressure Liquidmedicine.drugJournal of Chromatography A
researchProduct

Determination of busulfan in human plasma using high-performance liquid chromatography with pre-column derivatization and fluorescence detection.

1999

A rapid, sensitive and reproducible high-performance liquid chromatographic assay for busulfan in human plasma was developed. After extraction of plasma samples with acetonitrile and methylene chloride, busulfan and the internal standard [1,5-bis(methanesulfonyloxy)pentane] were derivatized with 8-mercaptoquinoline to yield fluorescent compounds which were detected with a fluorescence detector equipped with filters of 360 nm (excitation) and 425 nm (emission). Calibration graphs showed a linear correlation (r>0.9990) over the concentration range of 20-2000 ng/ml. The recovery of busulfan from plasma standards was 70+/-5%. The detection and quantification limits for busulfan in plasma sample…

ChromatographyChemistryExtraction (chemistry)Reproducibility of ResultsGeneral ChemistryReference StandardsHigh-performance liquid chromatographyFluorescenceSensitivity and SpecificityFluorescence spectroscopyPentanechemistry.chemical_compoundSpectrometry FluorescenceCalibrationmedicineHumansDerivatizationQuantitative analysis (chemistry)Antineoplastic Agents AlkylatingBusulfanBusulfanChromatography High Pressure Liquidmedicine.drugJournal of chromatography. B, Biomedical sciences and applications
researchProduct

Determination of alinidine in human plasma by high-performance liquid chromatography.

1981

ChromatographyChemistryHydrophilic interaction chromatographyAdministration OralGeneral ChemistryHigh-performance liquid chromatographyClonidineColumn chromatographyHuman plasmaReference ValuesAlinidineInjections IntravenousSupercritical fluid chromatographyHumansChromatography columnChromatography High Pressure LiquidHalf-LifeJournal of chromatography
researchProduct

Emerging approaches to estimate retention factors in high performance liquid chromatography.

2004

The retention factor is one of the most universally used parameters in chromatography. The errors associated with the conventional ways to determine the retention factor of compounds in liquid chromatography are studied and compared with those corresponding to new approaches. The later avoid the use of extra-column time and hold-up time values, which have proven to be tedious and ambiguous. Simulations and real data, used to examine the accuracy of four different approaches (two classic and two new), suggest that the new approaches could be considered more satisfactory than the classic ones.

ChromatographyChemistryOrganic ChemistryReproducibility of ResultsGeneral MedicineReference StandardsBiochemistryRetention timeHigh-performance liquid chromatographyChromatography High Pressure LiquidAnalytical ChemistryJournal of chromatography. A
researchProduct

Development of standard operation procedures for the manufacture of n-octadecyl bonded silicas as packing material in certified reference columns for…

2004

The development of standard operation procedures for the manufacture of a n-octadecyl bonded spherical silica packing from partially condensed tetraethoxysilane as silica source is described. The synthesis comprises five intermediate products and six synthesis steps which were examined according to their reproducibility and robustness. The results led to the optimisation of the manufacturing process for a n-octadecyl bonded silica. Correlations were drawn between the dynamic viscosity of the poly(ethoxy)siloxane (PES), the synthesis parameters, the resulting pore structural properties and particle size distribution of the silicas. Validated procedures were developed to manufacture spherical…

ChromatographyChemistrySilicon dioxideOrganic ChemistryAnalytical chemistryReproducibility of ResultsGeneral MedicineReversed-phase chromatographyReference StandardsSilicon DioxideBiochemistryHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundCertified reference materialsSiloxaneSpecific surface areaParticle-size distributionPorosityChromatography LiquidJournal of chromatography. A
researchProduct

Identification of diterpenes in canvas painting varnishes by gas chromatography-mass spectrometry with combined derivatisation.

2004

A derivatisation method that combines the formation of ethyl esters from the carboxylic groups and trimethylsilyl ethers from hydroxyl groups of the components of diterpenic resins is presented in this paper. This methodology involves two experimental steps: (1) formation of ethyl esters using ethyl chloroformate; and (2) the esterified compounds are lead to react with trimethylsilylimidazole to form the corresponding trimethylsilyl ethers. The main advantage of the proposed method is the possibility of performing simultaneously the analysis of amino acids from proteins, fatty acids from drying oils, and diterpenic compounds from natural resins usually found in works of art. This methodolog…

ChromatographySilylationTrimethylsilylChemistryOrganic ChemistryVarnishGeneral Medicineengineering.materialReference StandardsBiochemistryAnalytical Chemistrychemistry.chemical_compoundCanada balsamvisual_artPaintvisual_art.visual_art_mediumengineeringOrganic chemistryEthyl chloroformatePaintingsGas chromatographyGas chromatography–mass spectrometryDiterpenesAbietic acidJournal of chromatography. A
researchProduct

Hard cap espresso extraction-stir bar preconcentration of polychlorinated biphenyls in soil and sediments.

2017

Abstract A Nespresso © hard cap espresso machine has been employed for the quantitative extraction of polychlorinated biphenyls (PCBs) from sediments and soils. Sample extraction was performed from five grams of sample in less than 40 s, with 200 mL ethanol 40% (v/v) in water and PCBs were concentrated using stir bar sorptive extraction (SBSE) and determined by thermal desorption-gas chromatography-tandem mass spectrometry (TD-GC-MS-MS). Eleven PCB congeners (28, 52, 77, 80, 81, 101, 118, 138, 153,169, and 180) were determined in soils and sediments with limits of quantification in the 0.03–0.08 ng g −1 range. Extraction efficiency was established by the analysis of soil samples spiked with…

ChromatographySoil testChemistry010401 analytical chemistryExtraction (chemistry)010501 environmental sciencesMass spectrometry01 natural sciencesBiochemistryQuantitative determination0104 chemical sciencesAnalytical ChemistryEspressoCertified reference materialsEnvironmental chemistrySoil waterEnvironmental ChemistrySpectroscopy0105 earth and related environmental sciencesBar (unit)Analytica chimica acta
researchProduct

Influence of oscillating main flow on separation efficiency in asymmetrical flow field-flow fractionation.

2021

The steadily rising interest in the investigation of interactions between nanomaterials and biological media has also led to an increasing interest in asymmetrical flow field-flow fractionation (AF-FFF). The biggest strength of AF-FFF is the possibility to alter the flow profiles to suit a specific separation problem. In this paper, the influence of an oscillating main flow on the separation efficiency of AF-FFF is investigated. Such oscillations can e.g. be caused by the main pump To investigate the influence of such flow conditions on the separation efficiency in AF-FFF systematically, different oscillation profiles were applied and their influence on the elution profile and the retention…

ChromatographyTime FactorsFourier AnalysisElutionOscillationChemistryAsymmetrical Flow Field-Flow Fractionation010401 analytical chemistryOrganic ChemistryFlow (psychology)Separation (aeronautics)General MedicineFractionationMechanicsReference Standards010402 general chemistry01 natural sciencesBiochemistryFractionation Field Flow0104 chemical sciencesAnalytical ChemistryFlow conditionsPolystyrenesRheologySeparation problemJournal of chromatography. A
researchProduct

Rapid and simultaneous high-performance liquid chromatography assay of polyamines and monoacetylpolyamines in biological specimens

2000

A rapid, resolutive and reproducible reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed for polyamines and acetylpolyamines by adopting pre-column derivatization with benzoyl chloride. In a single run lasting less than 15 min ten polyamines were separated as well as traces of benzoic acid, methylbenzoate and benzoic anhydride. These contaminants, produced during the derivatization reaction, were almost all eliminated by washing steps envisaged in the same procedure. This simple and sensitive method can be applied to routine determination of polyamines in biological samples. A fine application of this procedure to the determination of endogenous content of p…

Chromatographymedicine.diagnostic_testorganic chemicalsBiogenic PolyaminesReproducibility of ResultsGeneral ChemistryReversed-phase chromatographyReference StandardsSensitivity and SpecificityHigh-performance liquid chromatographyBenzoic anhydridechemistry.chemical_compoundBenzoyl chloridechemistrySpectrophotometrymedicineSpectrophotometry UltravioletDerivatizationQuantitative analysis (chemistry)Chromatography High Pressure LiquidBenzoic acidJournal of Chromatography B: Biomedical Sciences and Applications
researchProduct

Assessment of Dietary Intake of Chromium (III) in Relation to Tolerable Upper Intake Level

2018

ChromiumAnimal scienceFood supplementchemistrybusiness.industryDietary Reference IntakeDietary intakeMedicinechemistry.chemical_elementbusinessRisk assessmentEuropean Journal of Nutrition & Food Safety
researchProduct