Search results for "Reproducibility"

showing 10 items of 1976 documents

RP-HPLC-DAD determination of the differences in the polyphenol content of Fucus vesiculosus extracts with similar antioxidant activity.

2021

Abstract Significant quantities of bioactive compounds have been found in the chemical composition of seaweeds. This source of natural antioxidants such as polyphenols appears to attenuate lipid peroxidation caused by oxidative stress, preventing the harmful effects of a number of injuries including ischemia–reperfusion (I/R). Conventional extraction (CE) has been used for years as a traditional method for obtaining bioactive components from seaweeds. However, recent studies highlight ultrasonic-assisted extraction (UAE) as an alternative and more eco-friendly technique. Therefore, the two methods were optimised and compared to obtain a Fucus vesiculosus extract (FVE) with high antioxidant …

Chromatography Reverse-PhaseChromatographyPlant ExtractsClinical BiochemistryPolyphenolsReproducibility of ResultsCell BiologyGeneral MedicineBiochemistryProtocatechuic acidAntioxidantsAnalytical ChemistryFerulic acidchemistry.chemical_compoundChlorogenic acidchemistryPolyphenolLimit of DetectionFucusCaffeic acidVanillic acidLinear ModelsGallic acidGentisic acidChromatography High Pressure LiquidJournal of chromatography. B, Analytical technologies in the biomedical and life sciences
researchProduct

Simple high-performance liquid chromatographic assay for polyamines and their monoacetyl derivatives.

1993

A rapid reversed-phase high-performance liquid chromatographic method, using pre-column derivatization with benzoyl chloride and ultraviolet detection at 254 nm, was developed for the simultaneous measurement of polyamines and their monoacetyl derivatives. Calibration curves were linear for concentrations from 1.25 to 25 nmol/ml. The method was employed to assay these compounds in chick embryo retina explants using organic solvent extraction and 1,7-diaminoheptane as an internal standard. This simple and sensitive method can be applied to routine determinations of these compounds in various biological samples.

ChromatographyCalibration curveOrganic solventExtraction (chemistry)Reproducibility of ResultsAcetylationGeneral ChemistryChick EmbryoDiaminesHigh-performance liquid chromatographyRetinachemistry.chemical_compoundBenzoyl chloridechemistryPolyaminesAnimalsSpectrophotometry UltravioletDerivatizationQuantitative analysis (chemistry)Chromatography High Pressure LiquidJournal of chromatography
researchProduct

Development of a new multi-analyte assay for the simultaneous detection of opioids in serum and other body fluids using liquid chromatography-tandem …

2015

Abstract A liquid chromatography–tandem mass spectrometry method using electrospray ionization in positive ionization mode was developed for the simultaneous detection of multiple opioid-type drugs in plasma. The presented assay allows the quantitative determination of alfentanil, buprenorphine, codeine, desomorphine, dextromethorphan, dextrorphan, dihydrocodeine, dihydromorphine, ethylmorphine, fentanyl, hydrocodone, hydromorphone, methadone, morphine, naloxone, naltrexone, oxycodone, oxymorphone, pentazocine, pethidine, pholcodine, piritramide, remifentanil, sufentanil, and tramadol as well as the metabolites 6-monoacetylmorphine, bisnortilidine, morphine-3-glucuronide, morphine-6-glucuro…

ChromatographyChemistryClinical BiochemistryCodeineReproducibility of ResultsCell BiologyGeneral MedicineEthylmorphineBiochemistryDihydrocodeineAnalytical ChemistryTriple quadrupole mass spectrometerBody FluidsAnalgesics Opioidchemistry.chemical_compoundLiquid chromatography–mass spectrometryLimit of DetectionTandem Mass SpectrometryIntensive caremedicineMorphineHumansNorbuprenorphinemedicine.drugChromatography LiquidJournal of chromatography. B, Analytical technologies in the biomedical and life sciences
researchProduct

Extraction of clenbuterol from calf urine using a molecularly imprinted polymer followed by quantitation by high-performance liquid chromatography wi…

2002

A method for the extraction of clenbuterol from calf urine samples using a molecularly imprinted polymer (MIP) has been developed. The aim was that the final extracts from the MIP should allow quantitation of clenbuterol down to 0.5 ng/mL urine using HPLC with UV detection. The MIP was produced using brombuterol as a template and the selectivity of the MIP, for clenbuterol, was tested against a non-imprinted polymer (produced without template) and was found to be high. After loading of 5 mL diluted centrifuged urine, selective binding was established in acetonitrile-acetic acid (98:2). For further elution of interferences, 0.5 M ammonium acetate buffer pH 5 and 70% acetonitrile in water was…

ChromatographyChemistryElutionOrganic ChemistryExtraction (chemistry)Molecularly imprinted polymerReproducibility of ResultsGeneral MedicineReversed-phase chromatographyReference StandardsSensitivity and SpecificityBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryClenbuterolmedicineAnimalsCattleClenbuterolSpectrophotometry UltravioletSample preparationSolid phase extractionAdrenergic alpha-AgonistsChromatography High Pressure Liquidmedicine.drugJournal of Chromatography A
researchProduct

Determination of busulfan in human plasma using high-performance liquid chromatography with pre-column derivatization and fluorescence detection.

1999

A rapid, sensitive and reproducible high-performance liquid chromatographic assay for busulfan in human plasma was developed. After extraction of plasma samples with acetonitrile and methylene chloride, busulfan and the internal standard [1,5-bis(methanesulfonyloxy)pentane] were derivatized with 8-mercaptoquinoline to yield fluorescent compounds which were detected with a fluorescence detector equipped with filters of 360 nm (excitation) and 425 nm (emission). Calibration graphs showed a linear correlation (r>0.9990) over the concentration range of 20-2000 ng/ml. The recovery of busulfan from plasma standards was 70+/-5%. The detection and quantification limits for busulfan in plasma sample…

ChromatographyChemistryExtraction (chemistry)Reproducibility of ResultsGeneral ChemistryReference StandardsHigh-performance liquid chromatographyFluorescenceSensitivity and SpecificityFluorescence spectroscopyPentanechemistry.chemical_compoundSpectrometry FluorescenceCalibrationmedicineHumansDerivatizationQuantitative analysis (chemistry)Antineoplastic Agents AlkylatingBusulfanBusulfanChromatography High Pressure Liquidmedicine.drugJournal of chromatography. B, Biomedical sciences and applications
researchProduct

Profiling of endogenous peptides by multidimensional liquid chromatography: On-line automated sample cleanup for biomarker discovery in human urine.

2009

A simple and flexible system, employing a column switching technique, has been designed to allow the analysis of peptides and proteins smaller than 15 kDa by molecular weight in filtered urine samples by performing a direct on-column injection utilising simultaneous sample clean-up and trace enrichment. The positively charged peptides and small proteins in the sample are attracted to the inner, negatively charged pore structure of the RAM-SCX column while the larger proteins and uncharged or negatively charged compounds are excluded. After preconditioning with the biological sample, large amounts of sample can be injected. Several important and adjustable parameters for the proper use of a …

ChromatographyChemistryIon chromatographyAnalytical chemistryReproducibility of ResultsFiltration and SeparationHydrogen-Ion ConcentrationMass spectrometryHigh-performance liquid chromatographyAnalytical ChemistryDilutionSpecimen HandlingMolecular WeightMatrix-assisted laser desorption/ionizationAdsorptionSpectrometry Mass Matrix-Assisted Laser Desorption-IonizationHumansSample preparationSolid phase extractionPeptidesBiomarkersChromatography LiquidJournal of separation science
researchProduct

Emerging approaches to estimate retention factors in high performance liquid chromatography.

2004

The retention factor is one of the most universally used parameters in chromatography. The errors associated with the conventional ways to determine the retention factor of compounds in liquid chromatography are studied and compared with those corresponding to new approaches. The later avoid the use of extra-column time and hold-up time values, which have proven to be tedious and ambiguous. Simulations and real data, used to examine the accuracy of four different approaches (two classic and two new), suggest that the new approaches could be considered more satisfactory than the classic ones.

ChromatographyChemistryOrganic ChemistryReproducibility of ResultsGeneral MedicineReference StandardsBiochemistryRetention timeHigh-performance liquid chromatographyChromatography High Pressure LiquidAnalytical ChemistryJournal of chromatography. A
researchProduct

Development of standard operation procedures for the manufacture of n-octadecyl bonded silicas as packing material in certified reference columns for…

2004

The development of standard operation procedures for the manufacture of a n-octadecyl bonded spherical silica packing from partially condensed tetraethoxysilane as silica source is described. The synthesis comprises five intermediate products and six synthesis steps which were examined according to their reproducibility and robustness. The results led to the optimisation of the manufacturing process for a n-octadecyl bonded silica. Correlations were drawn between the dynamic viscosity of the poly(ethoxy)siloxane (PES), the synthesis parameters, the resulting pore structural properties and particle size distribution of the silicas. Validated procedures were developed to manufacture spherical…

ChromatographyChemistrySilicon dioxideOrganic ChemistryAnalytical chemistryReproducibility of ResultsGeneral MedicineReversed-phase chromatographyReference StandardsSilicon DioxideBiochemistryHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundCertified reference materialsSiloxaneSpecific surface areaParticle-size distributionPorosityChromatography LiquidJournal of chromatography. A
researchProduct

Determination of α-Tocopherol in Plasma by High Performance Liquid Chromatography with Fluorescence Detection and Stability of α-Tocopherol under Dif…

2011

In order to study the clinical effects of the antioxidant alpha-tocopherol (tocofersolan, CAS 30999-06-5) a simple, robust, sensitive and reliable high performance liquid chromatography (HPLC) method using fluorescence detection for the daily measurement of alpha-tocopherol concentration in plasma is described. Several methods of HPLC analysis using fluorescence techniques are published, however, investigations of the stability of alpha-tocopherol during sample preparation under different conditions are relevant in the routine measurements and have to date not been reported. Therefore a modified method, both sensitive and robust, qualified for the day-by-day measurement of alpha-tocopherol …

ChromatographyChemistryalpha-TocopherolAnalytical chemistryReproducibility of Resultsfood and beveragesLiquid nitrogenHigh-performance liquid chromatographyFluorescenceFluorescence spectroscopyTocofersolanSpecimen Handlingchemistry.chemical_compoundSpectrometry FluorescenceDrug DiscoveryHumansSample preparationTocopherolQuantitative analysis (chemistry)Chromatography High Pressure LiquidArzneimittelforschung
researchProduct

Combined effect of solvent content, temperature and pH on the chromatographic behaviour of ionisable compounds. III: Considerations about robustness

2009

Abstract We previously reported a model able to predict the retention time of ionisable compounds as a function of the solvent content, temperature and pH [J. Chromatogr. A 1163 (2007) 49]. The model was applied further, developing an optimisation of the resolution based on the peak purity concept [J. Chromatogr. A 1193 (2008) 117]. However, we left aside an important issue: we did not consider incidental overlaps caused by shifts in the predicted peak positions, owing either to uncertainties in the source data, modelling errors, or the practical implementation in the chromatograph of the optimal mobile phase (or any other). These shifts can ruin the predicted separation, since they can eas…

ChromatographyChromatographyLogarithmChemistryOrganic ChemistryMonte Carlo methodTemperatureProbabilistic logicReproducibility of ResultsGeneral MedicineFunction (mathematics)Reversed-phase chromatographyHydrogen-Ion ConcentrationBiochemistryAnalytical ChemistryDistribution (mathematics)Models ChemicalRobustness (computer science)Phase (matter)SolventsComputer SimulationOrganic ChemicalsProtonsJournal of Chromatography A
researchProduct