In vitro production of GHB in blood and serum samples under various storage conditions

2011

Abstract The in vitro production of GHB was observed in freshly collected, untreated whole blood samples using glass BD-Vacutainers and polypropylene S-monovettes. GHB concentrations were determined daily over a period of one week and after 3, 6 and 9 weeks again. Furthermore, the GHB concentration in 40 untreated random whole blood samples stored at 4 °C for a longer period of time (10 samples 12 month, 10 samples 24 month and 20 samples 36 month) was also determined. For comparison, the in vitro production of GHB in freshly collected and prepared serum samples was observed. GHB serum concentrations were determined three times over a period of one week and once again after six weeks. Sampl…

AdultMaleTime FactorsHydroxybutyratesPoison controlIn Vitro TechniquesGas Chromatography-Mass SpectrometrySpecimen HandlingPathology and Forensic MedicineForensic ToxicologyHumansMedicineSample preparationWhole bloodChromatographybusiness.industryTemperatureForensic toxicologygamma-Hydroxybutyric acidMiddle AgedSerum samplesIn vitroAnesthesiaFemaleGas chromatography–mass spectrometrybusinessLawmedicine.drugForensic Science International
researchProduct

Clinical success of intrauterine insemination cycles is affected by the sperm preparation time.

2013

Objective To determine the impact of the time interval from the end of sperm preparation (TSP) to intrauterine insemination (IUI) on the outcome. Design Prospective multicentre cohort study. Setting Seven French centers (assisted reproduction group in northeastern France, four academic centers, and three clinics). Patient(s) Eight hundred sixty-two IUI cycles (709 patients) managed by gonadotropins were studied. Intervention(s) Cycles were stimulated by either FSH or hMG, and hCG was administrated when the leading follicle diameter measured >15 mm. IUIs were performed ∼36 hours after ovulation triggering. Main Outcome Measure(s) Generalized linear mixed models for binary outcomes were used …

AdultMaleendocrine systemmedicine.medical_specialtyTime FactorsPregnancy Ratemedia_common.quotation_subjectReproductive medicinelaw.inventionSpecimen HandlingSemen qualityRandomized controlled trialOvulation InductionlawPregnancyOdds RatioMedicineHumansProspective StudiesOvulationmedia_commonUnexplained infertilityInsemination Artificial HomologousGynecologyPregnancybusiness.industryAge FactorsObstetrics and GynecologyFertility Agents Femalemedicine.diseaseSpermatozoaTissue DonorsSemen AnalysisPregnancy rateFertilityTreatment OutcomeReproductive MedicineInfertilityMultivariate AnalysisLinear ModelsFemaleFrancebusinessCohort studyFertility and sterility
researchProduct

A preliminary study on the stability of benzodiazepines in blood and plasma stored at 4 degrees C.

1997

An approach to determine the stability of benzodiazepines and some of their metabolites (n = 13) by means of a routinely applied gas chromatographic method using electron capture detection was made in this preliminary study. Validation data of the method are given. Spiked blood and plasma samples were stored at 4 degrees C and analysed at selected times up to 240 days. The concentrations of all analytes had decreased to at least 60% of the original levels at the end of the observation period. A clear pattern of breakdown could not be established. The data obtained suggest that results from long-term stored samples should be interpreted cautiously. Further investigations concerning the stabi…

AnalyteChromatographyChromatography GasPlasma samplesChemistryObservation periodForensic toxicologyPlasmaForensic MedicinePathology and Forensic MedicineSpecimen HandlingSubstance Abuse DetectionBenzodiazepinesPlasmaBloodReference ValuesRefrigerationReference valuesLinear ModelsHumansGas chromatographyInternational journal of legal medicine
researchProduct

Functionally active complement proteins C6 and C7 detected in C6- and C7-deficient individuals

1991

SUMMARYTwo sensitive sandwich ELISAs based on monoclonal antibodies directed to native C6 and C7 allowed the detection and quantitation of these complement proteins in 20 out of 37 serum samples from individuals who had previously been classified as deficient in these proteins as assessed by immunochemical and/or functional assays. Furthermore, serum from four C6-deficient and one combined C6-/C7-deficient individual showed an increase in the terminal complement complex (TCC) and a decrease in native C6 and C7 after complement activation as assayed by specific ELISAs. Despite their (incomplete) deficiencies, these individuals therefore possess functionally active terminal complement protein…

Blood Bactericidal Activitymedicine.drug_classImmunoblottingImmunologyEnzyme-Linked Immunosorbent AssayBiologyMonoclonal antibodyComplement Hemolytic Activity AssaySpecimen Handling03 medical and health sciences0302 clinical medicineTerminal complement complexImmunopathologymedicineHumansImmunology and AllergyComplement ActivationVolume concentration030304 developmental biology0303 health sciencesTemperatureZymosanAntibodies MonoclonalComplement deficiencyComplement C9Serum samplesmedicine.diseaseMolecular biologyComplement C7Complement C63. Good healthComplement (complexity)Complement systemImmunologyElectrophoresis Polyacrylamide GelResearch Article030215 immunologyClinical and Experimental Immunology
researchProduct

Profiling of endogenous peptides by multidimensional liquid chromatography: On-line automated sample cleanup for biomarker discovery in human urine.

2009

A simple and flexible system, employing a column switching technique, has been designed to allow the analysis of peptides and proteins smaller than 15 kDa by molecular weight in filtered urine samples by performing a direct on-column injection utilising simultaneous sample clean-up and trace enrichment. The positively charged peptides and small proteins in the sample are attracted to the inner, negatively charged pore structure of the RAM-SCX column while the larger proteins and uncharged or negatively charged compounds are excluded. After preconditioning with the biological sample, large amounts of sample can be injected. Several important and adjustable parameters for the proper use of a …

ChromatographyChemistryIon chromatographyAnalytical chemistryReproducibility of ResultsFiltration and SeparationHydrogen-Ion ConcentrationMass spectrometryHigh-performance liquid chromatographyAnalytical ChemistryDilutionSpecimen HandlingMolecular WeightMatrix-assisted laser desorption/ionizationAdsorptionSpectrometry Mass Matrix-Assisted Laser Desorption-IonizationHumansSample preparationSolid phase extractionPeptidesBiomarkersChromatography LiquidJournal of separation science
researchProduct

Determination of α-Tocopherol in Plasma by High Performance Liquid Chromatography with Fluorescence Detection and Stability of α-Tocopherol under Dif…

2011

In order to study the clinical effects of the antioxidant alpha-tocopherol (tocofersolan, CAS 30999-06-5) a simple, robust, sensitive and reliable high performance liquid chromatography (HPLC) method using fluorescence detection for the daily measurement of alpha-tocopherol concentration in plasma is described. Several methods of HPLC analysis using fluorescence techniques are published, however, investigations of the stability of alpha-tocopherol during sample preparation under different conditions are relevant in the routine measurements and have to date not been reported. Therefore a modified method, both sensitive and robust, qualified for the day-by-day measurement of alpha-tocopherol …

ChromatographyChemistryalpha-TocopherolAnalytical chemistryReproducibility of Resultsfood and beveragesLiquid nitrogenHigh-performance liquid chromatographyFluorescenceFluorescence spectroscopyTocofersolanSpecimen Handlingchemistry.chemical_compoundSpectrometry FluorescenceDrug DiscoveryHumansSample preparationTocopherolQuantitative analysis (chemistry)Chromatography High Pressure LiquidArzneimittelforschung
researchProduct

New ECCO model documents for Material Deposit and Transfer Agreements in compliance with the Nagoya Protocol

2020

The European Culture Collections Organisation presents two new model documents for Material Deposit Agreement (MDA) and Material Transfer Agreement (MTA) designed to enable microbial culture collection leaders to draft appropriate agreement documents for, respectively, deposit and supply of materials from a public collection. These tools provide guidance to collections seeking to draft an MDA and MTA, and are available in open access to be used, modified, and shared. The MDA model consists of a set of core fields typically included in a deposit form to collect relevant information to facilitate assessment of the status of the material under access and benefit sharing (ABS) legislation. It a…

Code of conductEU regulation no. 511/2014 access and benefit sharing (ABS) european culture collections’ organisation (ECCO) convention on biological diversity (CBD) material deposit agreement (MDA) material transfer agreement (MTA)Biomedical ResearchKnowledge managementTraceabilityComputer scienceMini Reviewmedia_common.quotation_subjectBest practiceLegislationIntellectual propertyMicrobiologyaccess and benefit sharing (ABS)Specimen Handlingmaterial transfer agreement (MTA)03 medical and health sciencesTechnology Transferconvention on biological diversity (CBD)GeneticsHumansQuality (business)Nagoya ProtocolMolecular Biology030304 developmental biologymedia_commonProfessional Developmentmaterial deposit agreement (MDA)AcademicSubjects/SCI01150European culture collections' organisation (ECCO)0303 health sciencesScience & Technology030306 microbiologybusiness.industryeuropean culture collections organisation (ECCO)BiodiversityEuropeMaterial transfer agreementeuropean culture collections’ organisation (ECCO)EU regulation no. 511/2014Minireviewbusiness
researchProduct

A new interface to couple thin-layer chromatography with laser desorption/atmospheric pressure chemical ionization mass spectrometry for plate scanni…

2005

An interface to allow on-line qualitative and quantitative full-plate detection and analysis of compounds separated by thin-layer chromatography (TLC) is presented. A continuous wave diode laser is employed as a desorption source. Atmospheric pressure chemical ionization mass spectrometry ionizes and subsequently identifies the desorbed sample molecules. Besides direct laser desorption on untreated TLC plates, graphite particles were used as a matrix to couple in the laser power and improve the efficiency of desorption.

Desorption electrospray ionizationChromatographyMatrix-assisted laser desorption electrospray ionizationChemistryOrganic ChemistryAnalytical chemistryEquipment DesignMass spectrometryIon sourceSoft laser desorptionAnalytical ChemistryAtmospheric-pressure laser ionizationSpecimen HandlingEquipment Failure AnalysisSystems IntegrationAtmospheric PressureSpectrometry Mass Matrix-Assisted Laser Desorption-IonizationDirect electron ionization liquid chromatography–mass spectrometry interfaceSpectroscopyAmbient ionizationRapid communications in mass spectrometry : RCM
researchProduct

Changes to legal forensic inspections in Sicily during Covid-19

2020

Our institute, in collaboration with the Public Prosecutor’s Office, arranges for cadaveric inspections during a judicial inspection, jointly with the police. With the advent of the Covid-19 pandemic, operating methods have changed. Specifically, we now discuss the cases individually before attending to guarantee the health of operators and citizens

Forensic pathology2019-20 coronavirus outbreakCoronavirus disease 2019 (COVID-19)Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)Pneumonia ViralSpecimen HandlingSettore MED/43 - Medicina LegalePandemicmedicineHumansForensic PathologyPandemicsSicilybusiness.industryCOVID-19General MedicineForensic Medicinemedicine.diseasecadaveric ispection covid 19 operating methodForensic scienceAutopsyClinical CompetenceMedical emergencyClinical competenceCoronavirus InfectionsbusinessCoronavirus InfectionsMedico-Legal Journal
researchProduct

Photochemical sample treatment: a greener approach to chlorobenzene determination in sediments.

2014

Abstract Due to worker׳s exposure, solvent and stationary phases׳ consumption, sample purification is one of the most polluting steps in analytical procedures for determination of organic pollutants in real samples. The use of photochemical sample treatment represents a valid alternative methodology for extracts clean up allowing for a reduction of the used amount of organic solvents. In this paper we report the first application on the photolytic destruction of organic substances to eliminate some of the interferences in the analysis of Chlorobenzenes in sediment samples. The method׳s efficiency and robustness were compared with classic silica column purification process currently used in …

Geologic SedimentsPhotochemistryPhotochemistryChlorobenzenesSettore CHIM/12 - Chimica Dell'Ambiente E Dei Beni CulturaliGas Chromatography-Mass SpectrometryAnalytical ChemistrySpecimen Handlingchemistry.chemical_compoundLimit of DetectionSediment analysiClean upSoil PollutantsSettore CHIM/01 - Chimica Analiticasample treatmentPollutantDetection limitReproducibilityChromatographyChromatographySediment AnalysisPhotochemicalUV irradiationTemperatureReproducibility of ResultsWaterGreen Chemistry TechnologySettore CHIM/06 - Chimica OrganicaReplicateClean-upchemistryChlorobenzeneEnvironmental chemistrySolventsSediment analysisAnalytical proceduresChlorobenzeneTalanta
researchProduct