Search results for "detector"

showing 10 items of 3491 documents

Development of a 3D CZT Spectrometer System with Digital Readout for Hard X/Gamma-Ray Astronomy

2019

We report on the development and of a complete X/γ rays detection system (10-1000 keV) based on CZT spectrometers with spatial resolution in three dimensions (3D) and a digital electronics acquisition chain. The prototype is made by packing four linear modules, each composed of one 3D CZT sensors. Each sensors is realized using a single spectroscopic graded CZT crystal of about 20×20×5 mm3. An electrode structure consisting of 12 collecting anodes with a pitch of 1.6 mm and 3 drift strips between each pair of anodes for 48 strips (0.15 mm wide) on the anodic side was adopted. The cathode is made of 10 strips with a pitch of 2 mm and orthogonal to anode side strips. Since the reading of the …

Materials scienceSTRIPSCZT detectorsensorscomputer.software_genre01 natural scienceslaw.invention010309 opticsOpticslaw0103 physical sciencesDigital Readout010303 astronomy & astrophysicsImage resolutionDigital electronicsX-ray and gamma ray detectorsSpectrometerbusiness.industryFirmwareSettore FIS/01 - Fisica SperimentaleDetectorSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)CathodeAnode3D CZTbusinesscomputer2019 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)
researchProduct

Analysis of multipactor RF breakdown in a waveguide containing a transversely magnetized ferrite

2016

In this paper, the multipactor RF breakdown in a parallel-plate waveguide partially filled with a ferrite slab magnetized normal to the metallic plates is studied. An external magnetic field is applied along the vertical direction between the plates in order to magnetize the ferrite. Numerical simulations using an in-house 3-D code are carried out to obtain the multipactor RF voltage threshold in this kind of structures. The presented results show that the multipactor RF voltage threshold at certain frequencies becomes considerably lower than for the corresponding classical metallic parallel-plate waveguide with the same vacuum gap

Materials scienceSaturation magnetizationElectromagnetic waveguidesPhysics::Instrumentation and DetectorsIn-house 3D codeTransversely magnetized ferrite01 natural sciencesVacuum gap010305 fluids & plasmasExternal magnetic fieldOptics0103 physical sciencesVertical directionRadio frequencyTEORIA DE LA SEÑAL Y COMUNICACIONESParallel-plate waveguideElectronic engineeringNumerical simulationsElectrical and Electronic EngineeringMagnetic anisotropyElectric breakdownMultipactor RF breakdown analysis010302 applied physicsbusiness.industryParallel plate waveguidesFerrite slabRF breakdownMicrowave switchesVacuum gapElectronic Optical and Magnetic MaterialsMagnetic fieldMultipactor RF voltage thresholdMagnetic fieldMetallic platesMagnetic fieldsSlabFerrite (magnet)Ferrite waveguidesFerrite devicesMultipactor effectbusinessVoltageNumerical analysis
researchProduct

Growth kinetics of colloidal Ge nanocrystals for light harvesters

2016

Colloidal Ge nanocrystals (NCs) are gaining increased interest because of their potential application in low-cost optoelectronic and light harvesting devices. However, reliable control of colloidal NC synthesis is often an issue and a deeper understanding of the key-role parameters governing NC growth is highly required. Here we report an extended investigation on the growth of colloidal Ge NCs synthesized from a one-pot solution based approach. A systematic study of the effects of synthesis time, temperature and precursor concentration is elucidated in detail. X-ray diffraction (XRD) analysis reveals the presence of crystalline Ge NCs with a mean size (from 5 to 35 nm) decreasing with the …

Materials scienceScanning electron microscopePHOTODETECTORSGeneral Chemical EngineeringPhotodetectorNanotechnology02 engineering and technologyActivation energy010402 general chemistry01 natural sciencesSettore ING-INF/01 - ElettronicaColloidDynamic light scatteringPEDOT:PSSGermanium; Quantum dot; PHOTODETECTORSchemistry.chemical_classificationGermaniumQuantum dotGeneral ChemistryPolymer021001 nanoscience & nanotechnology0104 chemical scienceschemistryChemical engineeringNanocrystaloptoelectronic devices colloidal nanocrystals0210 nano-technology
researchProduct

Heavy-ion induced single event effects and latent damages in SiC power MOSFETs

2022

The advantages of silicon carbide (SiC) power MOSFETs make this technology attractive for space, avionics and high-energy accelerator applications. However, the current commercial technologies are still susceptible to Single Event Effects (SEEs) and latent damages induced by the radiation environment. Two types of latent damage were experimentally observed in commercial SiC power MOSFETs exposed to heavy-ions. One is observed at bias voltages just below the degradation onset and it involves the gate oxide. The other damage type is observed at bias voltages below the Single Event Burnout (SEB) limit, and it is attributed to alterations of the SiC crystal-lattice. Focused ion beam (FIB) and s…

Materials scienceScanning electron microscopeRadiationFocused ion beamelektroniikkakomponentitIonSEEschemistry.chemical_compoundstomatognathic systempuolijohteetGate oxideSilicon carbideSiC MOSFETsHeavy-ionDetectors and Experimental TechniquesElectrical and Electronic EngineeringPower MOSFETSafety Risk Reliability and Qualitybusiness.industryionisoiva säteilyCondensed Matter PhysicsLatent damageAtomic and Molecular Physics and OpticsSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialssäteilyfysiikkachemistrytransistoritOptoelectronicsSiC MOSFETs; Heavy-ion; Latent damage; SEEsbusinessVoltageMicroelectronics Reliability
researchProduct

Study of silica-based intrinsically emitting nanoparticles produced by an excimer laser

2019

International audience; We report an experimental study demonstrating the feasibility to produce both pure and Ge-doped silica nanoparticles (size ranging from tens up to hundreds of nanometers) using nanosecond pulsed KrF laser ablation of bulk glass. In particular, pure silica nanoparticles were produced using a laser pulse energy of 400 mJ on pure silica, whereas Ge-doped nanoparticles were obtained using 33 and 165 mJ per pulse on germanosilicate glass. The difference in the required energy is attributed to the Ge doping, which modifies the optical properties of the silica by facilitating energy absorption processes such as multiphoton absorption or by introducing absorbing point defect…

Materials scienceScanning electron microscopemedicine.medical_treatmentAnalytical chemistryPhysics::OpticsGeneral Physics and AstronomyNanoparticleCathodoluminescenceCondensed Matter02 engineering and technologylcsh:Chemical technologylcsh:Technology01 natural sciencesFull Research PaperNanomaterials010309 opticsoptical materials0103 physical sciencesScanning transmission electron microscopymedicineNanotechnologylcsh:TP1-1185General Materials ScienceDetectors and Experimental TechniquesElectrical and Electronic Engineeringlcsh:Sciencenanomaterials[PHYS.PHYS.PHYS-OPTICS]Physics [physics]/Physics [physics]/Optics [physics.optics]Laser ablationExcimer laserlcsh:TGe-dopedSilica021001 nanoscience & nanotechnologyNanomateriallcsh:QC1-999Laser ablationAmorphous solidNanoscienceOptical materiallcsh:Q0210 nano-technologylcsh:Physics
researchProduct

PPG embedded system for blood pressure monitoring

2014

In this work, we have designed and implemented a microcontroller-based embedded system for blood pressure monitoring through a PhotoPlethysmoGraphic (PPG) technique. In our system, it is possible to perform PPG measurements via reflectance mode. Hardware novelty of our system consists in the adoption of Silicon PhotoMultiplier detectors. The signal received from the photodetector is used to calculate the instantaneous heart rate and therefore the heart rate variability. The obtained results show that, by using our system, it is possible to easily extract both the PPG and the breath signal. These signals can be used to monitor the patients during the convalescence both in hospital and at hom…

Materials scienceSettore INF/01 - InformaticaPhotoPlethysmoGraphybusiness.industryDetectorPhotodetectorSettore ING-INF/02 - Campi ElettromagneticiSignalReflectivitySilicon PhotoMultiplierembedded systemMicrocontrollerSilicon photomultipliersensorEmbedded systemHeart rate variabilityBlood pressure monitoringsense organsbusinessComputer hardware2014 AEIT Annual Conference - From Research to Industry: The Need for a More Effective Technology Transfer (AEIT)
researchProduct

Activity monitoring of a gaseous tritium source by beta induced X-ray spectrometry

2013

Abstract For monitoring and control of gaseous tritium sources in fuel circulation systems of fusion reactors beta induced X-ray spectrometry (BIXS) seems to be an applicable method. The characteristics of a BIXS monitoring setup built at TLK were examined. A low-noise silicon drift detector (SDD) was used together with two thin beryllium windows evaporated with gold films of 100 nm for efficient X-ray production. The measured X-ray intensity was proportional to the tritium partial pressure and the average detection efficiency was evaluated as 32.6 × 10−8 cps/Bq. A tritium memory effect was revealed. From the results it was concluded that such a monitoring system would be a useful complemen…

Materials scienceSilicon drift detectorSiliconMechanical EngineeringRadiochemistrychemistry.chemical_elementPartial pressureFusion powerMass spectrometryNuclear Energy and EngineeringchemistryBeta (plasma physics)General Materials ScienceTritiumBerylliumCivil and Structural EngineeringFusion Engineering and Design
researchProduct

Development of a micro-analytical prototype for selective trace detection of orthonitrotoluene

2014

Abstract A silicon micro-analytical platform consisting of a micro-preconcentrator based on a hydrophobic zeolite, coupled to a silicon spiral micro-column was built. A chemical gas sensor acted as a miniaturized gas detector. This system allowed selective detection of orthonitrotoluene (ONT), an explosive-related compound at the sub-ppm level (365 ppb) in the presence of toluene and moisture.

Materials scienceSiliconMoisturebusiness.industryAnalytical chemistrychemistry.chemical_elementExplosive AgentsTolueneAnalytical Chemistrychemistry.chemical_compoundchemistryOptoelectronicsGas detectorZeolitebusinessSpectroscopyMicrochemical Journal
researchProduct

Detection and quantification of lung cancer biomarkers by a micro-analytical device using a single metal oxide-based gas sensor

2018

International audience; The analysis of exhaled volatile organic compounds (VOCs) related to lung cancer is a very promising wayin medical diagnosis because it is non-invasive and much less expensive than traditional medical analysisused so far. In that sense, a silicon micro-analytical platform consisting of a micro-preconcentrator cou-pled to a silicon spiral gas chromatographic micro-column was built, and a metal oxide-based gas sensorwas used as a miniaturized gas detector. This micro-fabricated device was successfully tested to selec-tively detect low concentrations of VOCs considered as lung cancer biomarkers, within a few minuteseven in presence of high concentrations of water vapor …

Materials scienceSiliconOxidechemistry.chemical_element02 engineering and technology01 natural sciences[SPI.MAT]Engineering Sciences [physics]/MaterialsMetalchemistry.chemical_compoundMaterials ChemistrymedicineGas detectorElectrical and Electronic Engineering[SPI.NANO]Engineering Sciences [physics]/Micro and nanotechnologies/MicroelectronicsLung cancerInstrumentationVolume concentration[SPI.ACOU]Engineering Sciences [physics]/Acoustics [physics.class-ph]Chromatography010401 analytical chemistrytechnology industry and agricultureMetals and Alloys021001 nanoscience & nanotechnologyCondensed Matter Physicsmedicine.disease0104 chemical sciences3. Good healthSurfaces Coatings and FilmsElectronic Optical and Magnetic Materialschemistryvisual_artCarbon dioxidevisual_art.visual_art_medium0210 nano-technologyWater vapor
researchProduct

Characterization of SiPM properties at liquid nitrogen temperature

2016

SiPM operation at cryogenic temperatures fails for many common devices. A particular type with deep channels in the silicon substrate instead of quenching resistors was thoroughly characterized from room temperature down to liquid nitrogen temperature by illuminating it with low light levels. The devices were mounted in vacuum with the temperature stabilized to allow long-term operation. SiPM signals from a LED pulser were acquired with single-pixel resolution. Generalized fits to the charge collection spectra were used to extract properties like single-pixel gain, inter-pixel variation, breakdown voltage, and photon detection efficiency. With these measurements a deeper investigation of th…

Materials scienceSiliconPhysics::Instrumentation and Detectors010308 nuclear & particles physicsbusiness.industrychemistry.chemical_elementCryogenicsLiquid nitrogen01 natural sciencesSpectral linelaw.inventionSilicon photomultiplierchemistrylaw0103 physical sciencesOptoelectronicsBreakdown voltagePhotonicsResistorbusiness2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)
researchProduct