Search results for "detector"
showing 10 items of 3491 documents
Development of a 3D CZT Spectrometer System with Digital Readout for Hard X/Gamma-Ray Astronomy
2019
We report on the development and of a complete X/γ rays detection system (10-1000 keV) based on CZT spectrometers with spatial resolution in three dimensions (3D) and a digital electronics acquisition chain. The prototype is made by packing four linear modules, each composed of one 3D CZT sensors. Each sensors is realized using a single spectroscopic graded CZT crystal of about 20×20×5 mm3. An electrode structure consisting of 12 collecting anodes with a pitch of 1.6 mm and 3 drift strips between each pair of anodes for 48 strips (0.15 mm wide) on the anodic side was adopted. The cathode is made of 10 strips with a pitch of 2 mm and orthogonal to anode side strips. Since the reading of the …
Analysis of multipactor RF breakdown in a waveguide containing a transversely magnetized ferrite
2016
In this paper, the multipactor RF breakdown in a parallel-plate waveguide partially filled with a ferrite slab magnetized normal to the metallic plates is studied. An external magnetic field is applied along the vertical direction between the plates in order to magnetize the ferrite. Numerical simulations using an in-house 3-D code are carried out to obtain the multipactor RF voltage threshold in this kind of structures. The presented results show that the multipactor RF voltage threshold at certain frequencies becomes considerably lower than for the corresponding classical metallic parallel-plate waveguide with the same vacuum gap
Growth kinetics of colloidal Ge nanocrystals for light harvesters
2016
Colloidal Ge nanocrystals (NCs) are gaining increased interest because of their potential application in low-cost optoelectronic and light harvesting devices. However, reliable control of colloidal NC synthesis is often an issue and a deeper understanding of the key-role parameters governing NC growth is highly required. Here we report an extended investigation on the growth of colloidal Ge NCs synthesized from a one-pot solution based approach. A systematic study of the effects of synthesis time, temperature and precursor concentration is elucidated in detail. X-ray diffraction (XRD) analysis reveals the presence of crystalline Ge NCs with a mean size (from 5 to 35 nm) decreasing with the …
Heavy-ion induced single event effects and latent damages in SiC power MOSFETs
2022
The advantages of silicon carbide (SiC) power MOSFETs make this technology attractive for space, avionics and high-energy accelerator applications. However, the current commercial technologies are still susceptible to Single Event Effects (SEEs) and latent damages induced by the radiation environment. Two types of latent damage were experimentally observed in commercial SiC power MOSFETs exposed to heavy-ions. One is observed at bias voltages just below the degradation onset and it involves the gate oxide. The other damage type is observed at bias voltages below the Single Event Burnout (SEB) limit, and it is attributed to alterations of the SiC crystal-lattice. Focused ion beam (FIB) and s…
Study of silica-based intrinsically emitting nanoparticles produced by an excimer laser
2019
International audience; We report an experimental study demonstrating the feasibility to produce both pure and Ge-doped silica nanoparticles (size ranging from tens up to hundreds of nanometers) using nanosecond pulsed KrF laser ablation of bulk glass. In particular, pure silica nanoparticles were produced using a laser pulse energy of 400 mJ on pure silica, whereas Ge-doped nanoparticles were obtained using 33 and 165 mJ per pulse on germanosilicate glass. The difference in the required energy is attributed to the Ge doping, which modifies the optical properties of the silica by facilitating energy absorption processes such as multiphoton absorption or by introducing absorbing point defect…
PPG embedded system for blood pressure monitoring
2014
In this work, we have designed and implemented a microcontroller-based embedded system for blood pressure monitoring through a PhotoPlethysmoGraphic (PPG) technique. In our system, it is possible to perform PPG measurements via reflectance mode. Hardware novelty of our system consists in the adoption of Silicon PhotoMultiplier detectors. The signal received from the photodetector is used to calculate the instantaneous heart rate and therefore the heart rate variability. The obtained results show that, by using our system, it is possible to easily extract both the PPG and the breath signal. These signals can be used to monitor the patients during the convalescence both in hospital and at hom…
Activity monitoring of a gaseous tritium source by beta induced X-ray spectrometry
2013
Abstract For monitoring and control of gaseous tritium sources in fuel circulation systems of fusion reactors beta induced X-ray spectrometry (BIXS) seems to be an applicable method. The characteristics of a BIXS monitoring setup built at TLK were examined. A low-noise silicon drift detector (SDD) was used together with two thin beryllium windows evaporated with gold films of 100 nm for efficient X-ray production. The measured X-ray intensity was proportional to the tritium partial pressure and the average detection efficiency was evaluated as 32.6 × 10−8 cps/Bq. A tritium memory effect was revealed. From the results it was concluded that such a monitoring system would be a useful complemen…
Development of a micro-analytical prototype for selective trace detection of orthonitrotoluene
2014
Abstract A silicon micro-analytical platform consisting of a micro-preconcentrator based on a hydrophobic zeolite, coupled to a silicon spiral micro-column was built. A chemical gas sensor acted as a miniaturized gas detector. This system allowed selective detection of orthonitrotoluene (ONT), an explosive-related compound at the sub-ppm level (365 ppb) in the presence of toluene and moisture.
Detection and quantification of lung cancer biomarkers by a micro-analytical device using a single metal oxide-based gas sensor
2018
International audience; The analysis of exhaled volatile organic compounds (VOCs) related to lung cancer is a very promising wayin medical diagnosis because it is non-invasive and much less expensive than traditional medical analysisused so far. In that sense, a silicon micro-analytical platform consisting of a micro-preconcentrator cou-pled to a silicon spiral gas chromatographic micro-column was built, and a metal oxide-based gas sensorwas used as a miniaturized gas detector. This micro-fabricated device was successfully tested to selec-tively detect low concentrations of VOCs considered as lung cancer biomarkers, within a few minuteseven in presence of high concentrations of water vapor …
Characterization of SiPM properties at liquid nitrogen temperature
2016
SiPM operation at cryogenic temperatures fails for many common devices. A particular type with deep channels in the silicon substrate instead of quenching resistors was thoroughly characterized from room temperature down to liquid nitrogen temperature by illuminating it with low light levels. The devices were mounted in vacuum with the temperature stabilized to allow long-term operation. SiPM signals from a LED pulser were acquired with single-pixel resolution. Generalized fits to the charge collection spectra were used to extract properties like single-pixel gain, inter-pixel variation, breakdown voltage, and photon detection efficiency. With these measurements a deeper investigation of th…