Search results for "liquid chromatography"
showing 10 items of 942 documents
Determination of trace elements in water by metal chelate capillary gas chromatography
1981
Analysis of Diuretics in Urine by Column-Switching Chromatography and Fluorescence Detection
1997
The potential of column-switching chromatography and fluorescence detection for the analysis of diuretics in urine is evaluated. Sample cleanup and chromatographic parameters have been optimized to achieve maximum sensitivity for the detection and quantification of some relevant diuretics. On the basis of these studies, an on-line procedure for the simultaneous determination of amiloride, furosemide, bumetanide and triamterene is presented. The linearity, precision, accuracy and sensitivity of the method are discussed. The utility of the described approach has been tested by analysing urine samples obtained after administration of bumetanide.
Determination of triamterene in urine by HPLC using fluorescence detection and column-switching
1994
A liquid chromatographic method incorporating column-switching and fluorimetric detection for the determination of triamterene in untreated urine, is described. The urine samples (5 μL) were directly introduced onto an Hypersil ODS-C18, 30 μm (20 mm×2.1 mm I.D.) pre-column. Polar urinary compounds were removed by flushing the pre-column with water for 1 min, and the analyte was then switched onto an HP-LiChrospher RP C18,5 μm (125 mm×4mm ID) analytical column using an acetonitrile/phosphate buffer gradient elution. Fluorescence detection was performed at 230 nm excitation and 430 nm emission wavelengths. The recovery of drug was 102±2% in the 0.10–20.0 μg/mL concentration range, the limit o…
Chromatographic determination of diuretics in urine samples using hybrid micellar mobile phases with fluorimetric detection
1998
Abstract A rapid and simple chromatographic procedure, that uses hybrid micellar mobile phases of sodium dodecyl sulphate (SDS), propanol and phosphate buffer at pH 3, and fluorimetric detection ( λ exc =270 nm, λ em =430 nm), is reported for the determination of mixtures of seven diuretics of diverse efficacy (amiloride, bendroflumethiazide, bumetanide, furosemide, hydroflumethiazide, piretanide and triamterene), in urine samples. The application of a sequential optimization procedure for the resolution of the mixtures of the diuretics was problematic. However, their separation was achieved through the use of an interpretive optimization procedure based on the accurate description of the r…
The quantitative determination of metabolites of 6-mercaptopurine in biological materials. VII. Chemical synthesis by phosphorylation of 6-thioguanos…
1990
Abstract A fast and reliable two-step method has been established for the chemical synthesis of 6-thioguanosine 5′-monophosphate, 6-thioguanosine 5′-diphosphate and 6-thioguanosine 5′-triphosphate starting from the ribonucleoside. In the first step, 6-thioguanosine dissolved in triethyl phosphate, at high yield reacts with phosphorus oxide trichloride to 6-thioguanosine 5′-monophosphate which is purified by anion-exchange chromatography on DEAE-Sephadex using a step gradient of hydrochloric acid. In the second step, 6-thioguanosine 5′-monophosphate dissolved in water, reacts with phosphoric acid in the presence of pyridine/dicyclohexyl carbodiimide and is converted to 6-thioguanosine 5′-dip…
Chromatographic and mass spectrometric characteristics of 20-dihydroaldosterone.
1992
The 20 alpha-reduced derivative of aldosterone, 20 alpha-dihydroaldosterone, was needed as reference compound in order to continue the studies on 18-hydroxylation in the Y-1 adrenal cell line. It was obtained by reduction of aldosterone with sodium borohydride. Analysis of the products of the reaction as methoxime trimethylsilyl (MO-TMS) derivatives by gas chromatography (GC) and GC-mass spectrometry (GC-MS) showed three possible forms of the compound. Their identification was confirmed by comparison with the products obtained by stereospecific reduction of aldosterone using 3 alpha,20 beta-hydroxysteroid dehydrogenase. Chromatographic behavior and mass spectra are given for the three forms…
An inter-laboratory validation of methods of lipid peroxidation measurement in UVA-treated human plasma samples
2010
Lipid peroxidation products like malondialdehyde, 4-hydroxynonenal and F2-isoprostanes are widely used as markers of oxidative stress in vitro and in vivo. This study reports the results of a multi-laboratory validation study by COST Action B35 to assess inter-laboratory and intra-laboratory variation in the measurement of lipid peroxidation. Human plasma samples were exposed to UVA irradiation at different doses (0, 15 J, 20 J), encoded and shipped to 15 laboratories, where analyses of malondialdehyde, 4-hydroxynonenal and isoprostanes were conducted. The results demonstrate a low within-day-variation and a good correlation of results observed on two different days. However, high coefficie…
Influence of photo-initiators in the preparation of methacrylate monoliths into poly(ethylene-co-tetrafluoroethylene) tubing for microbore HPLC.
2020
[EN] In this study, poly(butyl methacrylate-co-ethyleneglycol dimethacrylate) polymeric monoliths were in situ developed within 0.75 mm i.d. poly(ethylene-co-tetrafluoroethylene) (ETFE) tubing by UV polymerization via three different free-radical initiators fscce-azobisisobutyronitrile (AIBN), 2,2-dimethoxy-2-phenylacetophenone (DMPA) and 2-methyl-4'-(methylthio)-2-morpholinopropiophenone (MTMPP). The influence of the nature of each photo-initiator and irradiation time on the morphological features of the polymer was investigated by scanning electron microscopy, and the chromatographic properties of the resulting microbore columns were evaluated using alkyl benzenes as test substances. The …
Prediction of Peak Shape and Characterization of Column Performance in Liquid Chromatography as a Function of Flow Rate
2015
Traditionally, column performance in liquid chromatography has been studied using information from the elution of probe compounds at different flow rates through van Deemter plots, which relate the column plate height to the linear mobile phase velocity. A more recent approach to characterize columns is the representation of the peak widths (or the right and left peak half-widths) for a set of compounds versus their retention times, which, for isocratic elution, give rise to almost linear plots. In previous work, these plots have been shown to facilitate the prediction of peak profiles (width and asymmetry) with optimization purposes. In this work, a detailed study on the dependence of the …
Determination of pesticides and veterinary drug residues in food by liquid chromatography-mass spectrometry: A review
2015
Monitoring of pesticides and veterinary drug residues is required to enforce legislation and guarantee food safety. Liquid chromatography-mass spectrometry (LC-MS) is the prevailing technique for assessing both types of residues because LC offers a versatile and universal separation mechanism suitable for non-gas chromatography (GC) amenable and the majority of GC-amenable compounds. This characteristic becomes more relevant when LC is coupled to MS because the high sensitivity and specificity of the detector allows to apply generic sample preparation procedures, which simultaneously extract a wide variety of residues with different physico-chemical properties. Determination of metabolites …