Cardiac output in single-lead VDD pacing versus rate-matched VVIR pacing.
1995
The importance of atrioventricular synchronous pacing compared with single-chamber rate-responsive pacing is still under discussion, especially for low-intensity workload representing daily life activities. We evaluated hemodynamics in single-lead VDD pacing versus VVIR pacing in 11 patients (8 men and 3 women, aged 58.6 +/- 13.8 years) with normal left ventricular function and a previously implanted single-lead VDDR pacemaker. A low-intensity steady-state treadmill test at 1 to 2.5 mph with a gradient of 2% to 4% was performed. Cardiac output was determined using a standard carbon dioxide rebreathing technique. Initially, the VDD mode was programmed, and after 5 minutes of exercise, cardia…
Acute performance evaluation of a new ventricular automatic capture algorithm
2006
Aims This study evaluated the acute clinical performance of a new ventricular automatic capture algorithm developed to work with all lead types and pacing vectors. Methods and results During regular pacemaker implant or replacement, AutoThreshold and manual threshold tests were performed in ventricular unipolar (UP) and bipolar (BP, if applicable) pacing using a customized external prototype INSIGNIA™ pacemaker. The success rate and accuracy of two different modes (commanded and ambulatory) of the automatic capture algorithm were used to evaluate the performance. Loss-of-capture events (two consecutive non-captured beats without backup pacing) were used to assess safety. Data of 53 patients…
Screening for Fabry disease in male patients with arrhythmia requiring a pacemaker or an implantable cardioverter-defibrillator
2021
Implantation Strategy of the Atrial Dipole Impacts Atrial Sensing Performance of Single Lead VDD Pacemakers
2002
WIEGAND, U.K.H., et al.: Implantation Strategy of the Atrial Dipole Impacts Atrial Sensing Perfor-mance of Single Lead VDD Pacemakers. Intermittent atrial undersensing is observed in a considerable percentage of patients with single lead VDD pacemakers. Analyzing the 2-year data of the Saphir Multicenter Follow-Up Study, the authors investigated predictors for the occurrence of undersensing. The study included 194 patients with high degree AV block who received a VDD pacemaker system with an identical sensing amplifier. Placement strategy of the atrial dipole was left to the discretion of the implanting physician. At the final position, atrial potential amplitudes were measured during deep …
Temporal Trends in Transcatheter Aortic Valve Replacement in France
2017
Background - Transcatheter aortic valve replacement (TAVR) is standard therapy for patients with severe aortic stenosis who are at high surgical risk. However, national data regarding procedural characteristics and clinical outcomes over time are limited. Objectives - The aim of this study was to assess nationwide performance trends and clinical outcomes of TAVR during a 6-year period. Methods - TAVRs performed in 48 centers across France between January 2013 and December 2015 were prospectively included in the FRANCE TAVI (French Transcatheter Aortic Valve Implantation) registry. Findings were further compared with those reported from the FRANCE 2 (French Aortic National CoreValve and Edwa…
The COGNITION Study Rationale and Design: Influence of Closed Loop Stimulation on Cognitive Performance in Pacemaker Patients
2008
Background: Several studies showed the beneficial effect of pacemaker implantation on cognitive performance in patients with bradycardia. But it has never been investigated if patients with chronotropic incompetence may improve their cognitive performance if treated by a rate-adaptive system reacting to mental stress in comparison to the most frequently used accelerometer-driven pacing. Methods: The randomized, single-blind, multicenter COGNITION study evaluates if closed loop stimulation (CLS) offers incremental benefit in the speed of cognitive performance and the overall well-being of elderly patients with bradycardia compared with accelerometer-based pacing. Four hundred chronotropicall…
Managed ventricular pacing vs. conventional dual-chamber pacing for elective replacements: the PreFER MVP study: clinical background, rationale, and …
2008
Udgivelsesdato: 2008-Mar AIMS: Several clinical studies have shown that, in patients with intact atrioventricular (AV) conduction, unnecessary chronic right ventricular (RV) pacing can be detrimental. The managed ventricular pacing (MVP) algorithm is designed to give preference to spontaneous AV conduction, thus minimizing RV pacing. The clinical outcomes of MVP are being studied in several ongoing trials in patients undergoing a first device implantation, but it is unknown to what extent MVP is beneficial in patients with a history of ventricular pacing. The purpose of the Prefer for Elective Replacement MVP (PreFER MVP) study is to assess the superiority of the MVP algorithm to convention…
Pacemaker therapy in premature children with high degree AV block.
1998
The smallest pacemaker pulse generator and a steroid-eluting bipolar epicardial lead were implanted in two premature children with symptomatic AV block. Stable capture threshold and high amplitude evoked response electrogram resulted in normal function of the pacemaker Autocapture algorithm, which adjusts output 0.3 V above the measured capture threshold. Autocapture had previously been used only with endocardial leads. Longer-term observation is required.
Cardiac pacing in premature infants and neonates: steroid eluting leads and automatic output adaptation
1999
Abstract Background . Appropriate generator and lead selection as well as techniques of implantation are most important aspects of cardiac pacing in the extremely young patient. Here we report the clinical results using a new technique with automatic output adaptation based on evoked response in combination with steroid-eluting epicardial leads in small children. Methods . One neonate and 2 premature infants underwent permanent pacemaker implantation because of congenital high-degree atrioventricular block or postoperative complete heart block, respectively. Steroid-eluting epicardial leads and a multiprogrammable pacemaker with automatic output adaptation were used. Results . Intermuscular…
European Clinical Experience with a Dual Chamber Single Pass Sensing and Pacing Defibrillation Lead
2002
Dual chamber ICDs are increasingly implanted nowadays, mainly to improve discrimination between supraventricular and ventricular arrhythmias but also to maintain AV synchrony in patients with bradycardia. The aim of this study was to investigate a new single pass right ventricular defibrillation lead capable of true bipolar sensing and pacing in the right atrium and integrated bipolar sensing and pacing in the right ventricle. The performance of the lead was evaluated in 57 patients (age 61 +/- 12 years; New York Heart Association 1.9 +/- 0.6, left ventricular ejection fraction 0.38 +/- 0.15) at implant, at prehospital discharge, and during a 1-year follow-up. Sensing and pacing behavior of…