0000000000148505

AUTHOR

G. Bruno

Intrinsic backgrounds from Rn and Kr in the XENON100 experiment

In this paper, we describe the XENON100 data analyses used to assess the target-intrinsic background sources radon ([InlineMediaObject not available: see fulltext.]), thoron ([InlineMediaObject not available: see fulltext.]) and krypton ([InlineMediaObject not available: see fulltext.]). We detail the event selections of high-energy alpha particles and decay-specific delayed coincidences. We derive distributions of the individual radionuclides inside the detector and quantify their abundances during the main three science runs of the experiment over a period of ∼4years, from January 2010 to January 2014. We compare our results to external measurements of radon emanation and krypton concentr…

research product

First Axion Results from the XENON100 Experiment

We present the first results of searches for axions and axion-like-particles with the XENON100 experiment. The axion-electron coupling constant, $g_{Ae}$, has been tested by exploiting the axio-electric effect in liquid xenon. A profile likelihood analysis of 224.6 live days $\times$ 34 kg exposure has shown no evidence for a signal. By rejecting $g_{Ae}$, larger than $7.7 \times 10^{-12}$ (90% CL) in the solar axion search, we set the best limit to date on this coupling. In the frame of the DFSZ and KSVZ models, we exclude QCD axions heavier than 0.3 eV/c$^2$ and 80 eV/c$^2$, respectively. For axion-like-particles, under the assumption that they constitute the whole abundance of dark matte…

research product

Results from a calibration of XENON100 using a source of dissolved radon-220

A Rn 220 source is deployed on the XENON100 dark matter detector in order to address the challenges in calibration of tonne-scale liquid noble element detectors. We show that the Pb 212 beta emission can be used for low-energy electronic recoil calibration in searches for dark matter. The isotope spreads throughout the entire active region of the detector, and its activity naturally decays below background level within a week after the source is closed. We find no increase in the activity of the troublesome Rn 222 background after calibration. Alpha emitters are also distributed throughout the detector and facilitate calibration of its response to Rn 222 . Using the delayed coincidence of R…

research product

Online 222 Rn removal by cryogenic distillation in the XENON100 experiment

We describe the purification of xenon from traces of the radioactive noble gas radon using a cryogenic distillation column. The distillation column was integrated into the gas purification loop of the XENON100 detector for online radon removal. This enabled us to significantly reduce the constant 222 Rn background originating from radon emanation. After inserting an auxiliary 222 Rn emanation source in the gas loop, we determined a radon reduction factor of R>27 (95% C.L.) for the distillation column by monitoring the 222 Rn activity concentration inside the XENON100 detector.

research product

Carotid plaque detection improves the predictve value of CHA2DS2-VASc score in patients with non-valvular atrial fibrilation: The ARAPACIS Study

Abstract Background and aims Vascular disease (VD), as assessed by history of myocardial infarction or peripheral artery disease or aortic plaque, increases stroke risk in atrial fibrillation (AF), and is a component of risk assessment using the CHA 2 DS 2 -VASc score. We investigated if systemic atherosclerosis as detected by ultrasound carotid plaque (CP) could improve the predictive value of the CHA 2 DS 2 -VASc score. Methods We analysed data from the ARAPACIS study, an observational study including 2027 Italian patients with non-valvular AF, in whom CP was detected using Doppler Ultrasonography. Results VD was reported in 351 (17.3%) patients while CP was detected in 16.6% patients. Ad…

research product

Prima indagine sullo stato delle superfici inerbite in Italia

research product

Constraining the spin-dependent WIMP-nucleon cross sections with XENON1T

We report the first experimental results on spin-dependent elastic weakly interacting massive particle (WIMP) nucleon scattering from the XENON1T dark matter search experiment. The analysis uses the full ton year exposure of XENON1T to constrain the spin-dependent proton-only and neutron-only cases. No significant signal excess is observed, and a profile likelihood ratio analysis is used to set exclusion limits on the WIMP-nucleon interactions. This includes the most stringent constraint to date on the WIMP-neutron cross section, with a minimum of 6.3 × 10−42 cm2 at 30 GeV/c2 and 90% confidence level. The results are compared with those from collider searches and used to exclude new paramet…

research product

Being the Family Caregiver of a Patient With Dementia During the Coronavirus Disease 2019 Lockdown

Background: Family caregivers of patients with dementia are at high risk of stress and burden, and quarantine due to the coronavirus disease 2019 (COVID-19) pandemic may have increased the risk of psychological disturbances in this population. The current study was carried out during the national lockdown declared in March 2020 by the Italian government as a containment measure of the first wave of the coronavirus pandemic and is the first nationwide survey on the impact of COVID-19 lockdown on the mental health of dementia informal caregivers.Methods: Eighty-seven dementia centers evenly distributed on the Italian territory enrolled 4,710 caregiver–patient pairs. Caregivers underwent a tel…

research product

A low-mass dark matter search using ionization signals in XENON100

We perform a low-mass dark matter search using an exposure of 30\,kg$\times$yr with the XENON100 detector. By dropping the requirement of a scintillation signal and using only the ionization signal to determine the interaction energy, we lowered the energy threshold for detection to 0.7\,keV for nuclear recoils. No dark matter detection can be claimed because a complete background model cannot be constructed without a primary scintillation signal. Instead, we compute an upper limit on the WIMP-nucleon scattering cross section under the assumption that every event passing our selection criteria could be a signal event. Using an energy interval from 0.7\,keV to 9.1\,keV, we derive a limit on …

research product

Online $$^{222}$$ 222 Rn removal by cryogenic distillation in the XENON100 experiment

research product

Association of kidney disease measures with risk of renal function worsening in patients with type 1 diabetes

Background Albuminuria has been classically considered a marker of kidney damage progression in diabetic patients and it is routinely assessed to monitor kidney function. However, the role of a mild GFR reduction on the development of stage ≥3 CKD has been less explored in type 1 diabetes mellitus (T1DM) patients. Aim of the present study was to evaluate the prognostic role of kidney disease measures, namely albuminuria and reduced GFR, on the development of stage ≥3 CKD in a large cohort of patients affected by T1DM. Methods A total of 4284 patients affected by T1DM followed-up at 76 diabetes centers participating to the Italian Association of Clinical Diabetologists (Associazione Medici D…

research product

How radical prostatectomy procedures have changed over the last 10 years in Italy: a comparative analysis based on more than 1500 patients participating in the MIRROR-SIU/LUNA and the Pros-IT CNR study

Purpose Therapeutic strategies for prostate cancer (PCa) have been evolving dramatically worldwide. The current article reports on the evolution of surgical management strategies for PCa in Italy. Methods The data from two independent Italian multicenter projects, the MIRROR-SIU/LUNA (started in 2007, holding data of 890 patients) and the Pros-IT-CNR project (started in 2014, with data of 692 patients), were compared. Differences in patients' characteristics were evaluated. Multivariable logistic regression models were used to identify characteristics associated with robot-assisted (RA) procedure, nerve sparing (NS) approach, and lymph node dissection (LND). Results The two cohorts did not …

research product

First Results on the Scalar WIMP-Pion Coupling, Using the XENON1T Experiment

We present first results on the scalar coupling of weakly interacting massive particles (WIMPs) to pions from 1 t yr of exposure with the XENON1T experiment. This interaction is generated when the WIMP couples to a virtual pion exchanged between the nucleons in a nucleus. In contrast to most nonrelativistic operators, these pion-exchange currents can be coherently enhanced by the total number of nucleons and therefore may dominate in scenarios where spin-independent WIMP-nucleon interactions are suppressed. Moreover, for natural values of the couplings, they dominate over the spin-dependent channel due to their coherence in the nucleus. Using the signal model of this new WIMP-pion channel, …

research product

Response of the XENON100 dark matter detector to nuclear recoils

Results from the nuclear recoil calibration of the XENON100 dark matter detector installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), Italy are presented. Data from measurements with an external 241AmBe neutron source are compared with a detailed Monte Carlo simulation which is used to extract the energy dependent charge-yield Qy and relative scintillation efficiency Leff. A very good level of absolute spectral matching is achieved in both observable signal channels - scintillation S1 and ionization S2 - along with agreement in the 2-dimensional particle discrimination space. The results confirm the validity of the derived signal acceptance in earlier reported dark matte…

research product

Environmental risk assesment around archaeological sites in Sicily

research product

Major adverse cardiovascular events in non-valvular atrial fibrillation with chronic obstructive pulmonary disease: the ARAPACIS study

Chronic obstructive pulmonary disease (COPD) increases the risk of mortality in non-valvular atrial fibrillation (NVAF) patients. Data on the relationship of COPD to major cardiovascular events (MACE) in AF have not been defined. The aim of the study is to assess the predictive value of COPD on incident MACE in NVAF patients over a 3-year follow-up. In the Atrial Fibrillation Registry for Ankle-Brachial Index Prevalence Assessment-Collaborative Italian Study (ARAPACIS) cohort, we evaluate the impact of COPD on the following clinical endpoints: MACE (including vascular death, fatal/non-fatal MI and stroke/TIA), cardiovascular (CV) death and all-cause mortality. Among 2027 NVAF patients, pati…

research product

Removing krypton from xenon by cryogenic distillation to the ppq level

The XENON1T experiment aims for the direct detection of dark matter in a detector filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background induced by radioactive decays inside the detector has to be sufficiently low. One major contributor is the β -emitter 85 Kr which is present in the xenon. For XENON1T a concentration of natural krypton in xenon natKr/Xe<200ppq (parts per quadrillion, 1 ppq =10−15mol/mol) is required. In this work, the design, construction and test of a novel cryogenic distillation column using the common McCabe–Thiele approach is described. The system demonstrated a krypton reduction factor of 6.4⋅10⁵ with thermodynamic stabili…

research product

XENON100 dark matter results from a combination of 477 live days

We report on WIMP search results of the XENON100 experiment, combining three runs summing up to 477 live days from January 2010 to January 2014. Data from the first two runs were already published. A blind analysis was applied to the last run recorded between April 2013 and January 2014 prior to combining the results. The ultra-low electromagnetic background of the experiment, ~$5 \times 10^{-3}$ events/(keV$_{\mathrm{ee}}\times$kg$\times$day) before electronic recoil rejection, together with the increased exposure of 48 kg $\times$ yr improves the sensitivity. A profile likelihood analysis using an energy range of (6.6 - 43.3) keV$_{\mathrm{nr}}$ sets a limit on the elastic, spin-independe…

research product

Search for WIMP Inelastic Scattering off Xenon Nuclei with XENON100

We present the first constraints on the spin-dependent, inelastic scattering cross section of weakly interacting massive particles (WIMPs) on nucleons from XENON100 data with an exposure of 7.64 ×103 kg .days . XENON100 is a dual-phase xenon time projection chamber with 62 kg of active mass, operated at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy and designed to search for nuclear recoils from WIMP-nucleus interactions. Here we explore inelastic scattering, where a transition to a low-lying excited nuclear state of Xe 129 is induced. The experimental signature is a nuclear recoil observed together with the prompt deexcitation photon. We see no evidence for such inelastic WIMP-Xe…

research product

Search for Electronic Recoil Event Rate Modulation with 4 Years of XENON100 Data

We report on a search for electronic recoil event rate modulation signatures in the XENON100 data accumulated over a period of 4 years, from January 2010 to January 2014. A profile likelihood method, which incorporates the stability of the XENON100 detector and the known electronic recoil background model, is used to quantify the significance of periodicity in the time distribution of events. There is a weak modulation signature at a period of $431^{+16}_{-14}$ days in the low energy region of $(2.0-5.8)$ keV in the single scatter event sample, with a global significance of $1.9\,\sigma$, however no other more significant modulation is observed. The expected annual modulation of a dark matt…

research product

Prophylaxis of venous thromboembolism in elderly patients with multimorbidity

none 327 si Pharmacological thromboprophylaxis (TP) is known to reduce venous thromboembolism (VTE) in medical inpatients, but the criteria for risk-driven prescription, safety and impact on mortality are still debated. We analyze data on elderly patients with multimorbidities admitted in the year 2010 to the Italian internal medicine wards participating in the REPOSI registry to investigate the rate of TP during the hospital stay, and analyze the factors that are related to its prescription. Multivariate logistic regression, area under the ROC curve and CART analysis were performed to look for independent predictors of TP prescription. Association between TP and VTE, bleeding and death in …

research product

Material radioassay and selection for the XENON1T dark matter experiment

The XENON1T dark matter experiment aims to detect weakly interacting massive particles (WIMPs) through low-energy interactions with xenon atoms. To detect such a rare event necessitates the use of radiopure materials to minimize the number of background events within the expected WIMP signal region. In this paper we report the results of an extensive material radioassay campaign for the XENON1T experiment. Using gamma-ray spectroscopy and mass spectrometry techniques, systematic measurements of trace radioactive impurities in over one hundred samples within a wide range of materials were performed. The measured activities allowed for stringent selection and placement of materials during the…

research product

Hiding in plain sight: observing planet-starspot crossings with the James Webb Space Telescope

Transiting exoplanets orbiting active stars frequently occult starspots and faculae on the visible stellar disc. Such occultations are often rejected from spectrophotometric transits, as it is assumed they do not contain relevant information for the study of exoplanet atmopsheres. However, they can provide useful constraints to retrieve the temperature of active features and their effect on transmission spectra. We analyse the capabilities of the James Webb Space Telescope in the determination of the spectra of occulted starspots, despite its lack of optical wavelength instruments on board. Focusing on K and M spectral types, we simulate starspots with different temperatures and in differen…

research product

Neutral Iron Emission Lines From The Day-side Of KELT-9b -- The GAPS Programme With HARPS-N At TNG XX

We present the first detection of atomic emission lines from the atmosphere of an exoplanet. We detect neutral iron lines from the day-side of KELT-9b (Teq $\sim$ 4, 000 K). We combined thousands of spectrally resolved lines observed during one night with the HARPS-N spectrograph (R $\sim$ 115, 000), mounted at the Telescopio Nazionale Galileo. We introduce a novel statistical approach to extract the planetary parameters from the binary mask cross-correlation analysis. We also adapt the concept of contribution function to the context of high spectral resolution observations, to identify the location in the planetary atmosphere where the detected emission originates. The average planetary li…

research product

Search for Event Rate Modulation in XENON100 Electronic Recoil Data

We have searched for periodic variations of the electronic recoil event rate in the (2-6) keV energy range recorded between February 2011 and March 2012 with the XENON100 detector, adding up to 224.6 live days in total. Following a detailed study to establish the stability of the detector and its background contributions during this run, we performed an un-binned profile likelihood analysis to identify any periodicity up to 500 days. We find a global significance of less than 1 sigma for all periods suggesting no statistically significant modulation in the data. While the local significance for an annual modulation is 2.8 sigma, the analysis of a multiple-scatter control sample and the phas…

research product

Impact of COVID-19 on hand surgery in Italy: A comparison between the Northern and the Southern regions

The aims of this study were to evaluate the impact of the COVID-19 pandemic on emergency and elective hand surgery in four Italian regions that had either a high (Lombardy and Piemonte) or a low (Sicilia and Puglia) COVID-19 case load to discuss problems and to elaborate strategies to improve treatment pathways. A panel of hand surgeons from these different regions compared and discussed data from the centers they work in. The COVID-19 pandemic had an enormous impact on both elective and emergency surgery in Italy, not only in highly affected regions but also – and paradoxically even at a higher extent – in regions with a low COVID-19 case load. A durable and flexible redesign of hand surge…

research product

Dark Matter Search Results from a One Ton-Year Exposure of XENON1T

We report on a search for Weakly Interacting Massive Particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS. XENON1T utilizes a liquid xenon time projection chamber with a fiducial mass of $(1.30 \pm 0.01)$ t, resulting in a 1.0 t$\times$yr exposure. The energy region of interest, [1.4, 10.6] $\mathrm{keV_{ee}}$ ([4.9, 40.9] $\mathrm{keV_{nr}}$), exhibits an ultra-low electron recoil background rate of $(82\substack{+5 \\ -3}\textrm{ (sys)}\pm3\textrm{ (stat)})$ events/$(\mathrm{t}\times\mathrm{yr}\times\mathrm{keV_{ee}})$. No significant excess over background is found and a profile likelihood analysis parameterized in spatial and energy dimensions exclude…

research product

The XENON1T Dark Matter Experiment

The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is the first WIMP dark matter detector operating with a liquid xenon target mass above the ton-scale. Out of its 3.2 t liquid xenon inventory, 2.0 t constitute the active target of the dual-phase time projection chamber. The scintillation and ionization signals from particle interactions are detected with low-background photomultipliers. This article describes the XENON1T instrument and its subsystems as well as strategies to achieve an unprecedented low background level. First results on the detector response and the performance of the subsystems are also presented. © 2017, The Author(s).

research product

DARWIN: Towards the ultimate dark matter detector

DARk matter WImp search with liquid xenoN (DARWIN) will be an experiment for the direct detection of dark matter using a multi-ton liquid xenon time projection chamber at its core. Its primary goal will be to explore the experimentally accessible parameter space for Weakly Interacting Massive Particles (WIMPs) in a wide mass-range, until neutrino interactions with the target become an irreducible background. The prompt scintillation light and the charge signals induced by particle interactions in the xenon will be observed by VUV sensitive, ultra-low background photosensors. Besides its excellent sensitivity to WIMPs above a mass of 5 GeV/c2, such a detector with its large mass, low-energy …

research product

Removing krypton from xenon by cryogenic distillation to the ppq level

The XENON1T experiment aims for the direct detection of dark matter in a detector filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background induced by radioactive decays inside the detector has to be sufficiently low. One major contributor is the β-emitter 85Kr which is present in the xenon. For XENON1T a concentration of natural krypton in xenon natKr/Xe<200ppq (parts per quadrillion, 1ppq=10-15mol/mol) is required. In this work, the design, construction and test of a novel cryogenic distillation column using the common McCabe–Thiele approach is described. The system demonstrated a krypton reduction factor of 6.4 · 10 5 with thermodynamic stability a…

research product

Online ^{222}Rn removal by cryogenic distillation in the XENON100 experiment

International audience; We describe the purification of xenon from traces of the radioactive noble gas radon using a cryogenic distillation column. The distillation column was integrated into the gas purification loop of the XENON100 detector for online radon removal. This enabled us to significantly reduce the constant$^{222}$ Rn background originating from radon emanation. After inserting an auxiliary$^{222}$ Rn emanation source in the gas loop, we determined a radon reduction factor of $R\,>\,27$ (95% C.L.) for the distillation column by monitoring the$^{222}$ Rn activity concentration inside the XENON100 detector.

research product

First Dark Matter Search Results from the XENON1T Experiment

We report the first dark matter search results from XENON1T, a ∼2000-kg-target-mass dual-phase (liquid-gas) xenon time projection chamber in operation at the Laboratori Nazionali del Gran Sasso in Italy and the first ton-scale detector of this kind. The blinded search used 34.2 live days of data acquired between November 2016 and January 2017. Inside the (1042±12)-kg fiducial mass and in the [5,40] keVnr energy range of interest for weakly interacting massive particle (WIMP) dark matter searches, the electronic recoil background was (1.93±0.25)×10-4 events/(kg×day×keVee), the lowest ever achieved in such a dark matter detector. A profile likelihood analysis shows that the data are consisten…

research product

The Italian dementia with Lewy bodies study group (DLB-SINdem): toward a standardization of clinical procedures and multicenter cohort studies design

Dementia with Lewy bodies (DLB) causes elevated outlays for the National Health Systems due to high institutionalization rate and patients' reduced quality of life and high mortality. Furthermore, DLB is often misdiagnosed as Alzheimer's disease. These data motivate harmonized multicenter longitudinal cohort studies to improve clinical management and therapy monitoring. The Italian DLB study group of the Italian Neurological Society for dementia (SINdem) developed and emailed a semi-structured questionnaire to 572 national dementia centers (from primary to tertiary) to prepare an Italian large longitudinal cohort. The questionnaire surveyed: (1) prevalence and incidence of DLB; (2) clinical…

research product

Search for two-neutrino double electron capture of $^{124}$Xe with XENON100

Two-neutrino double electron capture is a rare nuclear decay where two electrons are simultaneously captured from the atomic shell. For $^{124}$Xe this process has not yet been observed and its detection would provide a new reference for nuclear matrix element calculations. We have conducted a search for two-neutrino double electron capture from the K-shell of $^{124}$Xe using 7636 kg$\cdot$d of data from the XENON100 dark matter detector. Using a Bayesian analysis we observed no significant excess above background, leading to a lower 90 % credibility limit on the half-life $T_{1/2}&gt;6.5\times10^{20}$ yr. We also evaluated the sensitivity of the XENON1T experiment, which is currently bein…

research product

CCDC 828560: Experimental Crystal Structure Determination

Related Article: G.Brancatelli, G.Bruno, F.Nicolo, L.Canfora, G.Ruisi|2011|Acta Crystallogr.,Sect.E:Struct.Rep.Online|67|o1366|doi:10.1107/S1600536811016564

research product

CCDC 735809: Experimental Crystal Structure Determination

Related Article: G.Ruisi, L.Canfora, G.Bruno, A.Rotondo, T.F.Mastropietro, E.A.Debbia, M.A.Girasolo, B.Megna|2010|J.Organomet.Chem.|695|546|doi:10.1016/j.jorganchem.2009.11.019

research product

CCDC 633704: Experimental Crystal Structure Determination

Related Article: R.Gitto, R.Ficarra, R.Stancanelli, M.Guardo, L.De Luca, M.L.Barreca, B.Pagano, A.Rotondo, G.Bruno, E.Russo, G.De Sarro, A.Chimirri|2007|Bioorg.Med.Chem.|15|5417|doi:10.1016/j.bmc.2007.05.059

research product

CCDC 883024: Experimental Crystal Structure Determination

Related Article: A.Terenzi, L.Tomasello, A.Spinello, G.Bruno, C.Giordano, G.Barone|2012|J.Inorg.Biochem.|117|103|doi:10.1016/j.jinorgbio.2012.08.011

research product

CCDC 735808: Experimental Crystal Structure Determination

Related Article: G.Ruisi, L.Canfora, G.Bruno, A.Rotondo, T.F.Mastropietro, E.A.Debbia, M.A.Girasolo, B.Megna|2010|J.Organomet.Chem.|695|546|doi:10.1016/j.jorganchem.2009.11.019

research product

CCDC 941509: Experimental Crystal Structure Determination

Related Article: S. Rubino, V. Di Stefano, A. Attanzio, L. Tesoriere, M.A. Girasolo, F. Nicolò, G. Bruno, S. Orecchio, G.C. Stocco|2014|Inorg.Chim.Acta|418|112|doi:10.1016/j.ica.2014.03.028

research product

SIMULAZIONE DI SPERIMENTAZIONI: SCHIERE IN REGIME COMPRESSIBILE. DIMA. Fluidodinamica: nota didattica n. 11. Giugno 2005. La pubblicazione, in regola con la Legge sulla stampa, da luogo ad un programma applicativo, estraibile dal sito: www.dima.unipa.it - percorso: personale/docenti/ditommaso/supporti didattici

research product