Search results for " High pressure liquid"
showing 10 items of 705 documents
Determination of benzomercaptans in environmental complex samples by combining zeolitic imidazolate framework-8-based solid-phase extraction and high…
2020
[EN] In this work, the synthesis of zeolitic imidazolate framework-8 (ZIF-8) crystals and their subsequent application as effective sorbents for extraction and preconcentration of several benzomercaptans from environmental complex samples is described. These materials were prepared by solvothermal approach varying the concentration of n-butylamine modulator to modify the surface of the metal-organic framework. The resulting materials were characterized by scanning and transmission electron microscopy, powder X-ray diffraction and Fourier transform infrared spectroscopy. The ZIF-8 material that gave the best features was selected as extractive phase and the influence of various parameters (s…
Determination of organophosphate flame retardants in soil and fish using ultrasound-assisted extraction, solid-phase clean-up, and liquid chromatogra…
2017
A solid–liquid extraction method in combination with high‐performance liquid chromatography and tandem mass spectrometry was developed and optimized for extraction and analysis of organophosphorus flame retardants in soil and fish. Methanol was chosen as the optimum extraction solvent, not only in terms of extraction efficiency, but also for its broader analyte coverage. The subsequent clean‐up by solid‐phase extraction is required to eliminate matrix coextractives and reduce matrix effects. Recoveries of the optimized method were 50–121% for soil and 47–123% for biota, both with high precision (RSDs <12% in soil and <23% in biota). The method limits of detection ranged from 0.06 to 0.20 ng…
Polymer-based materials modified with magnetite nanoparticles for enrichment of phospholipids
2018
[EN] A polymeric material modified with magnetic nanoparticles (MNPs) has been synthesized and evaluated as sorbent both for solid-phase extraction (SPE) and dispersive magnetic solid-phase extraction (MSPE) of phospholipids (PLs) in human milk samples. The synthesized sorbent was characterized by scanning electron microscopy and its iron content was also determined. Several experimental variables that affect the extraction performance (e.g. loading solvent, breakthrough volume and loading capacity) were investigated and a comparison between conventional SPE and MSPE modalities was done. The proposed method was satisfactorily applied to the analysis of PLs in human milk fat extracts in diff…
CRYPTIC SPECIES RELATED TO DALDINIA CONCENTRICA AND D. ESCHSCHOLZII, WITH NOTES ON D. BAKERI
2004
Daldinia macaronesica (from the Canary Islands and Madeira), D. palmensis (from the Canary Islands), D. martinii and D. raimundi (from Sicily), and D. vanderguchtiae (from Jersey, Channel Islands) spp. nov., are described, based on new combinations of teleomorphic and anamorphic characters. They all resemble the pantropical D. eschscholzii and/or the European D. concentrica with regard to teleomorphic characters and secondary metabolite profiles generated by analytical HPLC. The status of the newly described taxa was established by SEM of ascospores and microscopic studies of their anamorphs in comparison with various materials of the aforementioned known species. HPLC and SEM studies on th…
Biomarkers to disclose recent intake of alcohol: potential of 5-hydroxytryptophol glucuronide testing using new direct UPLC-tandem MS and ELISA metho…
2007
Aims: This study compared two new methods for direct determination of 5-hydroxytryptophol glucuronide (GTOL) in urine, a biomarker for detection of recent alcohol consumption. Methods: Urine samples were collected from ten alcoholic patients during recovery from intoxication. A direct injection ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for measurement of the urinary GTOL to 5-hydroxyindoleacetic acid (5-HIAA) ratio, and an ELISA assay for direct measurement of GTOL, were used. Comparison was made with the urinary ethanol and ethyl glucuronide (EtG) concentrations. Results: The breath ethanol concentration on admission ranged between 1.0-3.1 g/l. Th…
Charged Tags for the Identification of Oxidative Drug Metabolites Based on Electrochemistry and Mass Spectrometry
2020
Abstract Most of the active pharmaceutical ingredients like Metoprolol are oxidatively metabolized by liver enzymes, such as Cytochrome P450 monooxygenases into oxygenates and therefore hydrophilic products. It is of utmost importance to identify the metabolites and to gain knowledge on their toxic impacts. By using electrochemistry, it is possible to mimic enzymatic transformations and to identify metabolic hot spots. By introducing charged‐tags into the intermediate, it is possible to detect and isolate metabolic products. The identification and synthesis of initially oxidized metabolites are important to understand possible toxic activities. The gained knowledge about the metabolism will…
Comprehensive analytical strategy for biomonitoring of pesticides in urine by liquid chromatography–orbitrap high resolution mass spectrometry
2014
In this study we propose an analytical strategy that combines a target approach for the quantitative analysis of contemporary pesticide metabolites with a comprehensive post-target screening for the identification of biomarkers of exposure to environmental contaminants in urine using liquid chromatography coupled to high-resolution mass spectrometry (LC–HRMS). The quantitative method for the target analysis of 29 urinary metabolites of organophosphate (OP) insecticides, synthetic pyrethroids, herbicides and fungicides was validated after a previous statistical optimization of the main factors governing the ion source ionization and a fragmentation study using the high energy collision disso…
Mycotoxin Identification and In Silico Toxicity Assessment Prediction in Atlantic Salmon
2020
The present study aimed to identify mycotoxins in edible tissues of Atlantic salmon (Salmo salar) using liquid chromatography coupled to hybrid quadrupole time-of-flight mass spectrometry (LC-Q-TOF-MS). After using a non-targeted screening approach and a home-made spectral library, 233 mycotoxins were analyzed. Moreover, the occurrence of mycotoxins in fish filets was evaluated, and their potential toxicity was predicted by in silico methods. According to the obtained results, forty mycotoxins were identified in analyzed salmon samples, the predominant mycotoxins being enniatins (also rugulosin and 17 ophiobolins), commonly found in cereals and their by-products. Thus, mycotoxin carry-over …
Identification and quantification of phosphatidylcholines containing very-long-chain polyunsaturated fatty acid in bovine and human retina using liqu…
2010
The retina is one of the vertebrate tissues with the highest content in polyunsaturated fatty acids (PUFA). A large proportion of retinal phospholipids, especially those found in photoreceptor membranes, are dipolyunsaturated molecular species. Among them, dipolyunsaturated phosphatidylcholine (PC) molecular species are known to contain very-long-chain polyunsaturated fatty acids (VLC-PUFA) from the n-3 and n-6 series having 24-36 carbon atoms (C24-C36) and four to six double bonds. Recent interest in the role played by VLC-PUFA arose from the findings that a protein called elongation of very-long-chain fatty acids 4 (ELOVL4) is involved in their biosynthesis and that mutations in the ELOVL…
Comparison of four mass analyzers for determining carbosulfan and its metabolites in citrus by liquid chromatography/mass spectrometry
2006
Four liquid chromatography/mass spectrometry (LC/MS) systems, equipped with single quadrupole, triple quadrupole (QqQ), quadrupole ion trap (QIT) and quadrupole time-of-flight (QqTOF) mass analyzers, were evaluated for the analysis of carbosulfan and its main transformation products. The comparison of quantitative aspects (sensitivity, precision and accuracy) was emphasized. Results showed that the triple quadrupole instrument reaches at least 20-fold higher sensitivity (LOD from 0.04 to 0.4 microg kg(-1)) compared to the single quadrupole (4-70 microg kg(-1)), the QIT (4-25 microg kg(-1)) and the QqTOF (4-23 microg kg(-1)) instruments. Recoveries were over 70% for all the analytes, except …