Search results for " Limit"
showing 10 items of 1716 documents
Improved Solid Phase Extraction Procedure for Assay of Cephalosporins in Human Urine Samples
1998
Abstract Solid phase extraction technique has been evaluated for the treatment of urine samples in the analysis of cephalosporins before injection into an HP-Hypersil ODS-C18 column. Cephalexin, cefotaxime, cefazolin, cefuroxime, and cefoxitin were tested with seven different reversed-phase extraction column cartridges and the obtained urine extracts were not clean. However, 3M Empore extraction disk cartridges packed with octadecyl (C18) bonded silica provided clean extracts with a single extraction. The recoveries of the five cephalosporins ranged from 56 to 60 % in the 1.25–500 g/mL concentration range. The assay was accurate, precise, and adequate for testing the drug content in urine s…
Effect of the shampoo Ultra Clean on drug concentrations in human hair
2000
The influence of the special shampoo Ultra Clean (Zydot Unlimited, Tulsa, Oklahoma) on the results of hair analyses was investigated. Hair samples from persons (n = 14) with a known history of drug abuse were collected at autopsy. The hair samples were divided into separate strands which were analyzed both after washing with Ultra Clean and without treatment. Hair analyses were performed by methanol extraction under sonication, purification by solid phase extraction and GC/MS in SIM mode according to routine procedures for tetrahydrocannabinol (THC), cocaine, amphetamine, methylenedioxyamphetamine (MDA), methylenedioxymethamphetamine (MDMA), methylenedioxyethylamphetamine (MDE), heroin, 6-m…
On-line in-tube solid phase microextraction-capillary liquid chromatography method for monitoring degradation products of di-(2-ethylhexyl) phthalate…
2014
Abstract The main di-(2-ethylhexyl) phthalate (DEHP) degradation products, (2-ethylhexyl) phthalate (MEHP), diethyl phthalate (DEP) and dibutyl phthalate (DBP), have been tested. The proposed cost-effective method combines on-line, in-tube solid-phase micro extraction (IT-SPME) in in-valve configuration and capillary liquid chromatography with UV diode array detection (Cap-LC-DAD). Acidification of the samples at pH 3 improved markedly the estimation of MEHP. Aliquots of 4 mL of acidified water samples were directly processed. After sample loading, the analytes were desorbed with the mobile-phase and transferred to the monolithic capillary column. Satisfactory linearity and precision, absen…
Simple and commercial readily-available approach for the direct use of ionic liquid-based single-drop microextraction prior to gas chromatography
2009
A simple and commercial readily-available approach that enables the direct use of ionic liquid (IL)-based single-drop microextraction (SDME) prior to gas chromatography (GC) is presented. The approach is based on thermal desorption (TD) of the analytes from the IL droplet to the GC system, by using a robust and commercially-available thermodesorption system. For this purpose, a two-glass-tube concentrically disposed system was designed. The inner tube is a laboratory-cut Pyrex tube (20mm length) that houses the ionic liquid droplet from the SDME process, and the outer tube is a commercially-available TD glass tube (187 mm length) commonly employed for stir-bar sorptive extractions (SBSE). I…
RAPID LIQUID CHROMATOGRAPHIC DETERMINATION OF TETRACYCLINES IN ANIMAL FEEDS USING A SURFACTANT SOLUTION AS MOBILE PHASE
2002
ABSTRACT A chromatographic procedure was developed for the determination of oxytetracycline (OTC), tetracycline (TC), chlortetracycline (CTC), doxycycline (DC) and minocycline (MINO) in animal feeds. Clear analyte-rich extracts were obtained using a 1 : 1 acetonitrile/water mixture buffered at pH 3. The extracts were injected into a conventional unprotected C18 chromatographic column and eluted with a mobile phase of 0.05 M sodium dodecyl sulfate/5% 1-butanol/0.01 M oxalic acid at pH 3. Good resolution was achieved for the five compounds, whereas OTC and TC coeluted with an optimized aqueous-organic mobile phase of methanol/acetonitrile/0.01 M oxalic acid at pH 3. Mean recoveries from spike…
A solid-phase extraction and size-exclusion liquid chromatographic method for polyethylene glycol 25 p-aminobenzoic acid determination in urine: Vali…
2007
No previous publications about percutaneous absorption of polyethylene glycol 25 p-aminobenzoic acid (PEG-25 PABA) have been found in the literature and the expected levels to be found in human urine after sunscreens use are unknown. The method proposed here is suitable to determine PEG-25 PABA in the urine of sunscreens users in order to carry out studies on body accumulation/excretion. It is based on solid-phase extraction (SPE) with size-exclusion liquid chromatography determination. Solid-phase extraction allows the analyte to be retained and subsequently eluted for a clean-up, using a silica-based cartridge. The size-exclusion liquid chromatography of the eluted allows the rest of matr…
Determination of clenbuterol in urine by azo-dye precolumn derivatization and micellar liquid chromatography
1997
Clenbuterol has been determined in urine by solidphase extraction on a C18 cartridge, diazotization of the eluate with nitrite, coupling of the diazonium ion with 1-(naphthyl)ethylenediamine, and separation of the azo dye formed by HPLC with a C18 column and a micellar mobile phase containing 0.1 M sodium dodecyl sulphate, 12%n-butanol and 0.05 M citrate buffer, pH 3. Recoveries higher than 90% were obtained by mixing the samples with a 20% 0.2 M NaOH before extraction. Limits of detection of 51 and 6.7 ng L−1 were obtained with spectrophotometric and thermal lens spectrometric detection, respectively; respective repeatabilities were 3.1% (5 μg mL−1) and 5.6% (0.16 μg mL−1).
Determination of catecholamines in urine by micellar liquid chromatography with coulometric detection
1994
The determination of catecholamines by HPLC with a sodium dodecyl-sulphate (SDS), micellar mobile phase on a C18 column and with coulometric detection was studied. The eluate was conditioned at +0.25 and +0.00 V, and the current at −0.16V was recorded. A previously developed model which describes the chromatographic behaviour of solutes in HPLC with hybrid, micellar mobile phases was used to optimize the SDS and ethanol concentrations. A mobile phase of 0.15M SDS in a phosphate buffer of pH 3.4 and without ethanol is recommended. The limits of detection were 0.4–0.7 ng ml−1. The procedure was applied to the determination of unconjugated L-dopa, norepinephrine and dopamine in urine. Direct i…
Flow injection-chemiluminescence determination of octyl dimethyl PABA in sunscreen formulations
2002
Abstract A sensitive flow injection (FI) procedure was developed for the determination of the UV-filter octyl dimethyl PABA in sunscreen formulations based on its chemiluminescence (CL) induced by potassium permanganate in sulfuric acid. Both second-order and log–log calibration graphs can be used to perform the analysis. Ninety injections per hour can be carried out, which means a sample throughput of 18 h −1 if five injections per solution are performed. The limit of detection (3 σ ) was 25 ng ml −1 . The interference effects of the excipient and other UV filters are studied. Sunscreen formulations containing octyl dimethyl PABA were analysed by both the proposed FI-CL method and a liquid…
Simultaneous determination of Folpet and Metalaxyl in pesticide formulations by flow injection Fourier transform infrared spectrometry
2003
Fourier transform infrared (FTIR) spectrometric methodology has been developed for the simultaneous determination of Folpet and Metalaxyl in pesticide formulations. The method involves the extraction of both active principles by sonication of the sample with CHCl3 and direct measurement of the absorbance using peak height values at 1798 cm −1 corrected with a baseline defined at 1810 cm −1 for Folpet, and peak area data established from 1677 to 1667 cm −1 corrected using a baseline from 1692 to 1628 cm −1 for Metalaxyl. Limits of detection (3 s) values of 17 and 16 gg −1 were found for Folpet and Metalaxyl, respectively, with results comparable with those found by liquid chromatography with…