Search results for "DETECT"

showing 10 items of 5902 documents

Die selektive invers-voltammetrische Bestimmung des Antimons in salzsauren Lösungen nach Lösungswechsel in einer einfachen Durchflußzelle

1987

The selective invers-voltammetric determination of antimony in a simple flow-through cell in hydrochloric acid solutions is described. After double medium exchange for post-electrolysis and inverse-voltammetric determination, the determination of antimony is possible in the presence of a large excess of copper, bismuth and other elements. The limit of determination is 0.2–0.3 ppb Sb, the reproducibility 1.5% (10 ppb Sb).

ChemistryDetection thresholdStereochemistryClinical Biochemistrychemistry.chemical_elementHydrochloric acidGeneral MedicineCopperAnalytical ChemistryBismuthchemistry.chemical_compoundAntimonyGeneral Materials ScienceNuclear chemistryFresenius' Zeitschrift für analytische Chemie
researchProduct

Detection and characterization of emerging psychoactive substances by ion mobility spectrometry

2014

Rapid detection and identification of novel psychoactive substances (NPS) continues to present significant analytical challenges to forensic and analytical chemists. Ion mobility spectrometry (IMS) has been traditionally considered as the analytical technique of choice to detect illicit drugs in security points in airports, borderlines and customs. Databases of the reduced mobility (K0 ) values of illicit drugs are available in the scientific literature and they should be completed with data of emerging designer drugs. In this paper, we have evaluated the effect of different measurement conditions and determined the K0 values of an important number of NPS including different families; such …

Chemistrymedicine.drug_classIon-mobility spectrometryAnalytical techniquePharmaceutical ScienceReduced mobilityPhenethylaminesRapid detectionAnalytical ChemistryCharacterization (materials science)Designer drugSynthetic cannabinoidsmedicineForensic engineeringEnvironmental ChemistryBiochemical engineeringSpectroscopymedicine.drugDrug Testing and Analysis
researchProduct

On-line gradient liquid chromatography–Fourier transform infrared spectrometry determination of sugars in beverages using chemometric background corr…

2008

Abstract An on-line gradient reversed phase liquid chromatography–Fourier transform infrared spectrometry (LC–FTIR) method was developed for the determination of fructose, glucose, sucrose and maltose in beverages. Improved chromatographic resolution was obtained using a linear gradient from 75 to 55% (v/v) acetonitrile in water in 15 min. Changes in the background spectra were corrected employing “univariate background correction based on the use of a reference spectra matrix” (UBC-RSM) and using the ratio of absorbance (AR) at 2256 and 2253 cm −1 for the identification of the eluent spectra within the RSM. The method provided limits of detection in the order of 0.75 mg ml −1 . The precisi…

ChemometricsMatrix (chemical analysis)Detection limitColumn chromatographyChromatographyResolution (mass spectrometry)ChemistryAnalytical chemistryInfrared spectroscopyReversed-phase chromatographyFourier transform spectroscopyAnalytical ChemistryTalanta
researchProduct

Use of bone scintigraphy in the early diagnosis of bisphosphonate related osteonecrosis of the jaw. Case report and review of the literature

2018

The main aim of the present report is to show the potential utility of bone scintigraphy for the diagnosis of jaw osteonecrosis. We report the history of a 62-year-old woman underwent breast cancer surgery in 2010. Moreover, patient received postoperative radiotherapy and chemotherapy. Intravenous bisphosphonates were also added to the treatment strategy to reduce the risk of bone metastasis. However, a hypermetabolic focus on left hemimandible was evidenced with a bone scintigraphy during follow up. After a careful study, the diagnosis of Bisphosphonate Related Ostneonecrosis of the Jaw (BRONJ) was carried out. This case highlights that bone scintigraphy may be extremely helpful for the ea…

Chemotherapymedicine.medical_specialtyOral Medicine and Pathologymedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentPostoperative radiotherapyEarly detectionBone metastasisCase Report030206 dentistryBisphosphonate:CIENCIAS MÉDICAS [UNESCO]medicine.disease03 medical and health sciences0302 clinical medicineBreast cancerBone scintigraphy030220 oncology & carcinogenesisUNESCO::CIENCIAS MÉDICASmedicineRadiologybusinessOsteonecrosis of the jawGeneral Dentistry
researchProduct

Sensitivity of the Cherenkov Telescope Array to spectral signatures of hadronic PeVatrons with application to Galactic Supernova Remnants

2023

The local Cosmic Ray (CR) energy spectrum exhibits a spectral softening at energies around 3~PeV. Sources which are capable of accelerating hadrons to such energies are called hadronic PeVatrons. However, hadronic PeVatrons have not yet been firmly identified within the Galaxy. Several source classes, including Galactic Supernova Remnants (SNRs), have been proposed as PeVatron candidates. The potential to search for hadronic PeVatrons with the Cherenkov Telescope Array (CTA) is assessed. The focus is on the usage of very high energy $\gamma$-ray spectral signatures for the identification of PeVatrons. Assuming that SNRs can accelerate CRs up to knee energies, the number of Galactic SNRs whi…

Cherenkov Telescope ArrayGamma rays: generalstatistical [methods]energy spectrumFOS: Physical sciencesVHESettore FIS/05 - Astronomia E Astrofisicacosmic raysMethods: data analysissupernovadata analysis [methods][PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Cosmic raysInstrumentation and Methods for Astrophysics (astro-ph.IM)Cherenkov Telescope Arra ; alactic Supernova Remnants ; PeVatrons ;Methods: statisticalgalactic PeVatronsHigh Energy Astrophysical Phenomena (astro-ph.HE)emission spectrum) supernovae: general [(stars]Astronomy and AstrophysicssensitivityobservatoryGalactic PeVatronscosmic radiationspectralgalaxyhadron(Stars:) supernovae: generalAstrophysics - High Energy Astrophysical PhenomenaAstrophysics - Instrumentation and Methods for Astrophysics[PHYS.ASTR]Physics [physics]/Astrophysics [astro-ph]statisticalgeneral [gamma rays]signature
researchProduct

The e-ASTROGAM gamma-ray space observatory for the multimessenger astronomy of the 2030s

2018

e-ASTROGAM is a concept for a breakthrough observatory space mission carrying a gamma-ray telescope dedicated to the study of the non-thermal Universe in the photon energy range from 0.15 MeV to 3 GeV. The lower energy limit can be pushed down to energies as low as 30 keV for gamma-ray burst detection with the calorimeter. The mission is based on an advanced space-proven detector technology, with unprecedented sensitivity, angular and energy resolution, combined with remarkable polarimetric capability. Thanks to its performance in the MeV-GeV domain, substantially improving its predecessors, e-ASTROGAM will open a new window on the non-thermal Universe, making pioneering observations of the…

Cherenkov Telescope ArrayHigh-energy astrophysical phenomenaCompton and pair creation telescope; Gamma-ray astronomy; gamma-ray polarization; high-energy astrophysical phenomena; space mission; time-domain astronomyenergy resolution7. Clean energy01 natural sciencesSpace missionlaw.inventionIceCubeEinstein TelescopelawObservatoryLIGO010303 astronomy & astrophysicsKM3NeTPhysicsHigh Energy Astrophysical Phenomena (astro-ph.HE)Applied MathematicsAstrophysics::Instrumentation and Methods for AstrophysicsComputer Science Applications1707 Computer Vision and Pattern RecognitionGamma-ray astronomyGamma-ray polarizationCondensed Matter Physicsphoton: energyobservatoryNuclear astrophysicsApace missionAstrophysics - High Energy Astrophysical Phenomenaperformancedetector: technologyAstrophysics::High Energy Astrophysical PhenomenaFOS: Physical sciencesAstrophysics::Cosmology and Extragalactic Astrophysicsgamma ray: burstspace missionCompton and pair creation telescopeTelescope0103 physical sciencessupernovaElectroniccalorimetergamma ray: detectorOptical and Magnetic MaterialsKAGRAElectrical and Electronic Engineering010306 general physicsTime domain astronomyLISAGamma-ray astronomyEinstein TelescopeAstronomyInstitut für Physik und AstronomieTime-domain astronomyCherenkov Telescope ArraysensitivityLIGOmessengerKM3NeTVIRGO13. Climate actionCompton and pair creation telescope; Gamma-ray astronomy; gamma-ray polarization; high-energy astrophysical phenomena; space mission; time-domain astronomy; Electronic Optical and Magnetic Materials; Condensed Matter Physics; Computer Science Applications1707 Computer Vision and Pattern Recognition; Applied Mathematics; Electrical and Electronic Engineeringddc:520galaxyCompton and pair creation telescope; Gamma-ray astronomy; gamma-ray polarization; high-energy astrophysical phenomena; space mission; time-domain astronomy; Electronic Optical and Magnetic Materials; Condensed Matter Physics; Applied Mathematics; Electrical and Electronic Engineering[PHYS.ASTR]Physics [physics]/Astrophysics [astro-ph]
researchProduct

Chest pain unit: do not forget the clinical indexes

2020

Chest Painmedicine.medical_specialtybusiness.industryMEDLINEGeneral MedicineChest painMultidetector Computed TomographyMultidetector computed tomographymedicineHumansRadiologymedicine.symptombusinessHospital UnitsEchocardiography StressRevista Española de Cardiología (English Edition)
researchProduct

An in-tube SPME device for the selective determination of chlorophyll a in aquatic systems.

2010

We report a new device for the estimation of the content of chlorophyll a pigment in water samples as an indicator of water quality. The extraction of the pigment from water was also optimized. 10 mL of water was filtered through a nylon filter (45m pore size and 13 mm of diameter), after the chlorophylls were dissolved by immersing the filter in 1 mL of a low non-hazardous solvent as ethanol. An in-valve in-tube SPME device coupled to capillary liquid chromatography with diode array detection was designed. A capillary column of 70 cm in length (0.32 mm i.d. coated with 5% diphenyl–95% polydimethylsiloxane, 3m coating thickness) was used as the loop of the injection valve for preconcentrati…

Chlorophyll bDetection limitPheophytinChlorophyllQuality ControlChlorophyll aChromatographyExtraction (chemistry)Solid Phase ExtractionAnalytical chemistryPheophytinsSolid-phase microextractionAnalytical Chemistrychemistry.chemical_compoundchemistryLimit of DetectionChlorophyllSolventsSample preparationFiltrationWater Pollutants ChemicalTalanta
researchProduct

Quantification of poisons for Ziegler Natta catalysts and effects on the production of polypropylene by gas chromatographic with simultaneous detecti…

2020

[EN] This article describes a new simultaneous method for the analysis of sulfur-type poisons, hydrocarbons and permanent gases affecting the productivity of the Ziegler Natta catalyst during the synthesis of polypropylene on an industrial scale in a fluidized-bed reactor. The identification was achieved employing a configuration of the seven-valve chromatographic system, with events at different times, allowing distribution of the sample through multiple columns, and finally reaching the helium ionization detectors of pulsed discharge, flame ionization and mass spectrometry. The results obtained show a good precision of the method used because the variability was less than 1.02% in area an…

Chromatography GasCalibration curveHydrogen sulfidechemistry.chemical_element010402 general chemistryMass spectrometryPolypropylenes01 natural sciencesBiochemistryHeliumCatalysisMass SpectrometryPoisonsAnalytical Chemistrylaw.inventionchemistry.chemical_compoundGas chromatographiclawIonizationCIENCIA DE LOS MATERIALES E INGENIERIA METALURGICAFlame ionization detectorHydrogen SulfideZiegler–Natta catalystFlame IonizationChromatography010401 analytical chemistryOrganic ChemistryGeneral MedicineHydrocarbons0104 chemical sciences08.- Fomentar el crecimiento económico sostenido inclusivo y sostenible el empleo pleno y productivo y el trabajo decente para todoschemistryAcetyleneCalibrationPolypropyleneCarbonZiegler Natta catalysts
researchProduct

Stability of Plant Sterols in Ingredients Used in Functional Foods

2011

The content of plant sterol (PS) and their oxidation products (POPs) in eight ingredients used to enrich functional foods was studied. A gas chromatographic (GC) technique with mass-spectrometric detection was used for identification, while GC with a flame ionization detector (GC-FID) was used for quantification. β-Sitosterol was the most abundant phytosterol, and the main POPs found were derived from this compound (7α/β-hydroxysitosterol, 7-ketositosterol, and sitostanetriol). The total amount of POPs found in the ingredients ranged from 29.03 to 110.02 μg/100 g PS. The β-sitosterol oxidation rates ranged from 10 to 50 μg β-sitosterol oxides/100 g of β-sitosterol. In view of this low rate …

Chromatography GasChromatographyChemistryPhytosterolReproducibility of ResultsGeneral ChemistryPlantsMass spectrometrySterollaw.inventionSterolsIngredientFunctional FoodLimit of DetectionlawFlame ionization detectorGas chromatographyGas chromatography–mass spectrometryGeneral Agricultural and Biological SciencesOxidation-ReductionPlant sterolsJournal of Agricultural and Food Chemistry
researchProduct