Search results for "Detectors"
showing 10 items of 2229 documents
Method for finding the critical temperature of the island in a SET structure
2008
We present a method to measure the critical temperature of the island of a superconducting single electron transistor. The method is based on a sharp change in the slope of the zero-bias conductance as a function of temperature. We have used this method to determine the superconducting phase transition temperature of the Nb island of an superconducting single electron transistor with Al leads. We obtain $T_\mathrm{c}^\mathrm{Nb}$ as high as 8.5 K and gap energies up to $\Delta_\mathrm{Nb}\simeq 1.45$ meV. By looking at the zero bias conductance as a function of magnetic field instead of temperature, also the critical field of the island can be determined. Using the orthodox theory, we have …
Patterning of Suitable Structures for the Investigation of the Josephson Effect in YBa2Cu3O7/PrBa2Cu3O7 Superlattices
1996
The aim of our work is to investigate the Josephson effect in YBa 2 Cu 3 O 7-δ /PrBa 2 Cu 3 O 7-δ superlattices. In the case of current flow along c axis direction the superlattice forms an array of artificial Josephson junctions where the YBa 2 Cu 3 O 7-δ layers are the superconducting electrodes which are separated but Josephson coupled by the PrBa 2 Cu 3 O 7-δ sheets. In this paper we report on the preparation, characterisation and patterning of the superlattices into suitable structures via standard photolithograpy and lift-off technique.
Microrefrigeration by quasiparticle tunnelling in NIS and SIS junctions
2000
Abstract A solid-state refrigeration method at sub-kelvin temperatures has been developed. It is based on quasiparticle tunnelling between a superconductor and a normal metal, or, between two dissimilar superconducting metals. The refrigerator is fabricated by combining nanolithography and micromachining methods. This technique has been demonstrated in both electron cooling from 0.3 to 0.1 K and in refrigeration of a dielectric platform. We describe a new fabrication method of tunnel junctions in a shadow evaporation configuration using a mechanical mask of silicon nitride.
Refrigeration of a dielectric membrane by superconductor/insulator/normalmetal/insulator/superconductor tunneling
1997
We have applied tunneling of electrons between a normal metal and a superconductor to refrigerate a thin dielectric membrane attached to the normal electrode of a superconductor/ insulator/normal-metal/insulator/superconductor (SINIS) structure. Starting from T≈200 mK, a decrease in temperature of several mK was observed, measured by a separate thermometer on the membrane. It should be straightforward to improve the refrigerator performance to the level of the recently demonstrated SINIS electron cooling method, such that the drop in the lattice temperature would be more than an order of magnitude larger.
Efficient electronic cooling in heavily doped silicon by quasiparticle tunneling
2001
Cooling of electrons in a heavily doped silicon by quasiparticle tunneling using a superconductor–semiconductor–superconductor double-Schottky-junction structure is demonstrated at low temperatures. In this work, we use Al as the superconductor and thin silicon-on-insulator (SOI) film as the semiconductor. The electron–phonon coupling is measured for the SOI film and the low value of the coupling is shown to be the origin of the observed significant cooling effect.
Spectral broadening by spatial effects in X-ray microcalorimeters with superconducting absorber and NTD-Ge thermal sensor
2004
We discuss how the sensitivity to the position of absorption of the photons can affect the spectral resolution of X-ray microcalorimeters with superconducting Sn absorber and NTD-Ge thermal sensor. Data obtained through the computer simulations are reported for microcalorimeters with different geometries and phonon transmission probabilities at the interface between the absorber and thermistor.
Experimental evidence of an incomplete thermalization of the energy in an x-ray microcalorimeter with a TaAu absorber.
2008
We have conducted an experimental test at our XACT facility using an x-ray microcalorimeter with Ta∕Au absorber and neutron transmutation doped germanium thermal sensor. The test was aimed at measuring the percentage of energy effectively thermalized after absorption of x-ray photons in superconducting tantalum. Moreover, in general, possible formation of long living quasiparticles implies that by using a superconducting absorber, a fraction of the deposited energy could not be thermalized on the useful time scale of the thermal sensor. To investigate this scenario, we exploited an absorber made of gold, where no energy trapping is expected, with a small piece of superconducting tantalum at…
Highly sensitive superconducting circuits at ∼700 kHz with tunable quality factors for image-current detection of single trapped antiprotons
2016
We developed highly-sensitive image-current detection systems based on superconducting toroidal coils and ultra-low noise amplifiers for non-destructive measurements of the axial frequencies (550$\sim$800$\,$kHz) of single antiprotons stored in a cryogenic multi-Penning-trap system. The unloaded superconducting tuned circuits show quality factors of up to 500$\,$000, which corresponds to a factor of 10 improvement compared to our previously used solenoidal designs. Connected to ultra-low noise amplifiers and the trap system, signal-to-noise-ratios of 30$\,$dB at quality factors of > 20$\,$000 are achieved. In addition, we have developed a superconducting switch which allows continuous tu…
Commissioning of the ATLAS Muon Spectrometer with cosmic rays
2010
The ATLAS detector at the Large Hadron Collider has collected several hundred million cosmic ray events during 2008 and 2009. These data were used to commission the Muon Spectrometer and to study the performance of the trigger and tracking chambers, their alignment, the detector control system, the data acquisition and the analysis programs. We present the performance in the relevant parameters that determine the quality of the muon measurement. We discuss the single element efficiency, resolution and noise rates, the calibration method of the detector response and of the alignment system, the track reconstruction efficiency and the momentum measurement. The results show that the detector i…
Integration of GMR sensors with different technologies
2016
Less than thirty years after the giant magnetoresistance (GMR) effect was described, GMR sensors are the preferred choice in many applications demanding the measurement of low magnetic fields in small volumes. This rapid deployment from theoretical basis to market and state-of-the-art applications can be explained by the combination of excellent inherent properties with the feasibility of fabrication, allowing the real integration with many other standard technologies. In this paper, we present a review focusing on how this capability of integration has allowed the improvement of the inherent capabilities and, therefore, the range of application of GMR sensors. After briefly describing the …